Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Data Brief ; 8: 915-24, 2016 Sep.
Article En | MEDLINE | ID: mdl-27508243

In this data article we provide a detailed standard operating procedure for performing a tandem mass spectrometry, multiplex assay of 6 lysosomal enzymes for newborn screening of the lysosomal storage diseases Mucopolysaccharidosis-I, Pompe, Fabry, Niemann-Pick-A/B, Gaucher, and Krabbe, (Elliott, et al., 2016) [1]. We also provide the mass spectrometry peak areas for the product and internal standard ions typically observed with a dried blood spot punch from a random newborn, and we provide the daily variation of the daily mean activities for all 6 enzymes.

2.
Mol Genet Metab ; 118(4): 304-9, 2016 08.
Article En | MEDLINE | ID: mdl-27238910

BACKGROUND: There is current expansion of newborn screening (NBS) programs to include lysosomal storage disorders because of the availability of treatments that produce an optimal clinical outcome when started early in life. OBJECTIVE: To evaluate the performance of a multiplex-tandem mass spectrometry (MS/MS) enzymatic activity assay of 6 lysosomal enzymes in a NBS laboratory for the identification of newborns at risk for developing Pompe, Mucopolysaccharidosis-I (MPS-I), Fabry, Gaucher, Niemann Pick-A/B, and Krabbe diseases. METHODS AND RESULTS: Enzyme activities (acid α-glucosidase (GAA), galactocerebrosidase (GALC), glucocerebrosidase (GBA), α-galactosidase A (GLA), α-iduronidase (IDUA) and sphingomyeline phosphodiesterase-1 (SMPD-1)) were measured on ~43,000 de-identified dried blood spot (DBS) punches, and screen positive samples were submitted for DNA sequencing to obtain genotype confirmation of disease risk. The 6-plex assay was efficiently performed in the Washington state NBS laboratory by a single laboratory technician at the bench using a single MS/MS instrument. The number of screen positive samples per 100,000 newborns were as follows: GAA (4.5), IDUA (13.6), GLA (18.2), SMPD1 (11.4), GBA (6.8), and GALC (25.0). DISCUSSION: A 6-plex MS/MS assay for 6 lysosomal enzymes can be successfully performed in a NBS laboratory. The analytical ranges (enzyme-dependent assay response for the quality control HIGH sample divided by that for all enzyme-independent processes) for the 6-enzymes with the MS/MS is 5- to 15-fold higher than comparable fluorimetric assays using 4-methylumbelliferyl substrates. The rate of screen positive detection is consistently lower for the MS/MS assay compared to the fluorimetric assay using a digital microfluidics platform.


Galactosylceramidase/blood , Glucosylceramidase/blood , Iduronidase/blood , Lysosomal Storage Diseases/blood , Sphingomyelin Phosphodiesterase/blood , alpha-Galactosidase/blood , alpha-Glucosidases/blood , Dried Blood Spot Testing , Enzyme Assays , Fabry Disease/blood , Fabry Disease/physiopathology , Female , Gaucher Disease/blood , Gaucher Disease/physiopathology , Glycogen Storage Disease Type II/blood , Glycogen Storage Disease Type II/physiopathology , Humans , Infant, Newborn , Leukodystrophy, Globoid Cell/blood , Leukodystrophy, Globoid Cell/physiopathology , Lysosomal Storage Diseases/classification , Lysosomal Storage Diseases/genetics , Lysosomal Storage Diseases/pathology , Male , Mucopolysaccharidosis I/blood , Mucopolysaccharidosis I/physiopathology , Neonatal Screening , Niemann-Pick Diseases/blood , Niemann-Pick Diseases/physiopathology , Tandem Mass Spectrometry
...