Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 153
Filter
1.
J Diabetes Sci Technol ; : 19322968241275701, 2024 Oct 06.
Article in English | MEDLINE | ID: mdl-39369312

ABSTRACT

INTRODUCTION: An error grid compares measured versus reference glucose concentrations to assign clinical risk values to observed errors. Widely used error grids for blood glucose monitors (BGMs) have limited value because they do not also reflect clinical accuracy of continuous glucose monitors (CGMs). METHODS: Diabetes Technology Society (DTS) convened 89 international experts in glucose monitoring to (1) smooth the borders of the Surveillance Error Grid (SEG) zones and create a user-friendly tool-the DTS Error Grid; (2) define five risk zones of clinical point accuracy (A-E) to be identical for BGMs and CGMs; (3) determine a relationship between DTS Error Grid percent in Zone A and mean absolute relative difference (MARD) from analyzing 22 BGM and nine CGM accuracy studies; and (4) create trend risk categories (1-5) for CGM trend accuracy. RESULTS: The DTS Error Grid for point accuracy contains five risk zones (A-E) with straight-line borders that can be applied to both BGM and CGM accuracy data. In a data set combining point accuracy data from 18 BGMs, 2.6% of total data pairs equally moved from Zones A to B and vice versa (SEG compared with DTS Error Grid). For every 1% increase in percent data in Zone A, the MARD decreased by approximately 0.33%. We also created a DTS Trend Accuracy Matrix with five trend risk categories (1-5) for CGM-reported trend indicators compared with reference trends calculated from reference glucose. CONCLUSION: The DTS Error Grid combines contemporary clinician input regarding clinical point accuracy for BGMs and CGMs. The DTS Trend Accuracy Matrix assesses accuracy of CGM trend indicators.

2.
JAMA Intern Med ; 184(10): 1246-1247, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39102259

ABSTRACT

This Teachable Moment describes a 62-year-old man with thyrotoxicosis due to excess levothyroxine exposure during tirzepatide treatment that induced rapid weight loss.


Subject(s)
Thyrotoxicosis , Weight Loss , Humans , Thyrotoxicosis/chemically induced , Weight Loss/drug effects , Female , Middle Aged , Male
4.
Diabetes Technol Ther ; 26(9): 652-660, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38696672

ABSTRACT

Objective: To evaluate the safety and explore the efficacy of use of ultra-rapid lispro (URLi, Lyumjev) insulin in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology in children, teenagers, and adults living with type 1 diabetes (T1D). Methods: At 14 U.S. diabetes centers, youth and adults with T1D completed a 16-day lead-in period using lispro in a t:slim X2 insulin pump with Control-IQ 1.5 technology, followed by a 13-week period in which URLi insulin was used in the pump. Results: The trial included 179 individuals with T1D (age 6-75 years). With URLi, 1.7% (3 participants) had a severe hypoglycemia event over 13 weeks attributed to override boluses or a missed meal. No diabetic ketoacidosis events occurred. Two participants stopped URLi use because of infusion-site discomfort, and one stopped after developing a rash. Mean time 70-180 mg/dL increased from 65% ± 15% with lispro to 67% ± 13% with URLi (P = 0.004). Mean insulin treatment satisfaction questionnaire score improved from 75 ± 13 at screening to 80 ± 11 after 13 weeks of URLi use (mean difference = 6; 95% confidence interval 4-8; P < 0.001), with the greatest improvement reported for confidence avoiding symptoms of high blood sugar. Mean treatment-related impact measure-diabetes score improved from 74 ± 12 to 80 ± 12 (P < 0.001), and mean TRIM-Diabetes Device (score improved from 82 ± 11 to 86 ± 12 (P < 0.001). Conclusions: URLi use in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology was safe for adult and pediatric participants with T1D, with quality-of-life benefits of URLi use perceived by the study participants. Clinicaltrials.gov registration: NCT05403502.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 1 , Hypoglycemic Agents , Insulin Infusion Systems , Insulin Lispro , Humans , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 1/blood , Adolescent , Insulin Lispro/therapeutic use , Insulin Lispro/administration & dosage , Male , Female , Child , Hypoglycemic Agents/therapeutic use , Hypoglycemic Agents/administration & dosage , Adult , Middle Aged , Young Adult , Blood Glucose/analysis , Blood Glucose/drug effects , Aged , Hypoglycemia/prevention & control , Hypoglycemia/chemically induced , Glycated Hemoglobin/analysis , Quality of Life , Patient Satisfaction , Treatment Outcome
5.
Diabetes Res Clin Pract ; 212: 111690, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38697300

ABSTRACT

AIMS: Continuous glucose monitoring (CGM) metrics can assist diabetes management. Consensus statements recommend > 70 % time in range (TIR) and ≤ 36 % glucose coefficient of variation (CV). However, how these targets perform in clinical practice is unknown. This retrospective, longitudinal cohort study analyzed relationships between TIR, CV, glycated hemoglobin (HbA1c), and hypoglycemia in a real-world setting. METHODS: Data of 542 adults with type 1 diabetes who used CGM (January 2014-July 2020) were analyzed. Associations between TIR and HbA1c at the same and subsequent visits, incidence rate ratios (IRRs) for hypoglycemia at different CVs, and number of hypoglycemic events at cross-sections of HbA1c and CV were estimated by regression. RESULTS: TIR was inversely related to HbA1c; for every 10 % increase in TIR, HbA1c was significantly reduced by 0.34 % (4 mmol/mol) and 0.20 % (2 mmol/mol) at the same and subsequent visits, respectively. Level 2 hypoglycemia was significantly reduced at CV < 30 %, 30-33 %, 33.1-36 %, and 36.1-40 %: adjusted IRRs vs CV ≥ 40.1 % of 0.14, 0.28, 0.32, and 0.50, respectively. Hypoglycemic events were reduced at lower CV across HbA1c levels and at higher HbA1c across CV levels. CONCLUSION: This study quantifies HbA1c improvements with increased TIR and hypoglycemia reductions with improved CV in clinical practice.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 1 , Glycated Hemoglobin , Hypoglycemia , Humans , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/drug therapy , Female , Male , Retrospective Studies , Adult , Glycated Hemoglobin/analysis , Glycated Hemoglobin/metabolism , Blood Glucose Self-Monitoring/methods , Hypoglycemia/blood , Hypoglycemia/epidemiology , Blood Glucose/analysis , Blood Glucose/metabolism , Middle Aged , Longitudinal Studies , Hypoglycemic Agents/therapeutic use , Continuous Glucose Monitoring
6.
J Diabetes Sci Technol ; : 19322968241254811, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38805364

ABSTRACT

BACKGROUND: We investigated the risk of incident diabetic retinopathy (DR) among high glycator compared to low glycator patients based on the hemoglobin glycation index (HGI). Visit-to-visit variations in HGI also were assessed. METHODS: Glycated hemoglobin (HbA1c) and continuous glucose monitoring data were collected up to 7 years prior to the date of eye examination defining incident DR or no retinopathy (control). Hemoglobin glycation index was calculated as difference in measured HbA1c and an estimated A1c from sensor glucose (eA1c) to define high (HbA1c - eA1c >0%) or low (HbA1c - eA1c <0%) glycator. Stable glycators were defined as ≥75% of visits with same HGI category. Logistic regression was used to assess the association between glycation category and incident DR. RESULTS: Of 119 adults with type 1 diabetes (T1D), 49 (41%) were stable low glycator (HbA1c - eA1c <0%), 36 (30%) were stable high glycator (HbA1c - eA1c >0%), and 34 (29%) were unstable glycator. Using alternate criteria to define high vs low glycator (consistent difference in HbA1c - eA1c of > 0.4% or <0.4%, respectively), 53% of the adults were characterized as unstable glycator. Compared to low glycators, high glycators did not have a significantly higher risk for incident DR over time when adjusted for age, T1D duration and continuous glucose monitoring (CGM) sensor type (odds ratio [OR] = 1.31, 95% confidence interval [CI] = 0.48-3.62, P = .15). CONCLUSIONS: The risk of diabetic retinopathy was not found to differ significantly comparing high glycators to low glycators in adults with T1D. Moreover, HbA1c - eA1c relationship was not stable in nearly 30% to 50% adults with T1D, suggesting that discordance in HbA1c and eA1c are mostly related either HbA1c measurements or estimation of A1c from sensor glucose rather than physiological reasons.

7.
Diabetes Ther ; 15(7): 1647-1655, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38743306

ABSTRACT

INTRODUCTION: This study was aimed at investigating changes in insulin requirements and glycemic outcomes in adults with type 1 diabetes (T1D) using Control IQ (Tandem Diabetes) automated insulin delivery system (AID) over 8 months of tirzepatide treatment. METHODS: In this single-center, observational study, we collected demographic, A1c, weight, sensor glucose, and insulin dose data for adults with T1D who were using AID and initiated tirzepatide adjunct therapy for clinical indications (n = 11, median age 37, 64% female and mean body mass index of 39.6 kg/m2). Data were compared from baseline and over 8 months. RESULTS: Within 2 months of tirzepatide treatment, there were significant reductions in total daily insulin [median (IQR) 73.9 (47.6-95.8) to 51.7 (46.7-66.8) units/day, p < 0.001], basal insulin [47 (28.2-51.8) to 32.4 (25.5-46.3) units/day, p < 0.001], and bolus insulin [31.4 (19.9-38.3) to 17.9 (14.9-22.2) units/day, p < 0.001] requirements. Insulin dose reduction from 2 to 8 months was modest. The frequency of user-initiated boluses did not differ throughout the study. Despite reductions in total insulin requirement, time in range (70-180 mg/dl) increased by 7%, A1c reduced by 0.5%, weight reduced by 9%, without increase in time below 70 mg/dl. CONCLUSIONS: This pilot study provides clinical guidance on insulin titration for adults with T1D who may initiate tirzepatide therapy. Based on the findings of this study, we recommend reducing 25% of total daily insulin dose at tirzepatide initiation in adults with T1D using AID with baseline A1c of less than 7.5%. Higher doses of tirzepatide were associated with greater weight loss, however, the reduction in insulin requirement was minimal.

8.
J Diabetes Sci Technol ; 18(4): 835-846, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38629784

ABSTRACT

BACKGROUND: Continuous glucose monitoring (CGM) has transformed the care of type 1 and type 2 diabetes, and there is potential for CGM to also become influential in prediabetes identification and management. However, to date, we do not have any consensus guidelines or high-quality evidence to guide CGM goals and metrics for use in prediabetes. METHODS: We searched PubMed for all English-language articles on CGM use in nonpregnant adults with prediabetes published by November 1, 2023. We excluded any articles that included subjects with type 1 diabetes or who were known to be at risk for type 1 diabetes due to positive islet autoantibodies. RESULTS: Based on the limited data available, we suggest possible CGM metrics to be used for individuals with prediabetes. We also explore the role that glycemic variability (GV) plays in the transition from normoglycemia to prediabetes. CONCLUSIONS: Glycemic variability indices beyond the standard deviation and coefficient of variation are emerging as prominent identifiers of early dysglycemia. One GV index in particular, the mean amplitude of glycemic excursion (MAGE), may play a key future role in CGM metrics for prediabetes and is highlighted in this review.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Prediabetic State , Humans , Prediabetic State/diagnosis , Prediabetic State/blood , Blood Glucose/analysis , Continuous Glucose Monitoring
9.
J Diabetes Sci Technol ; : 19322968241245680, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38629877

ABSTRACT

BACKGROUND: Once weekly Glucagon-Like Peptide-1 Receptor Agonists (GLP-1 RA) have been shown to improve glycemic outcomes and cause significant weight loss. However, 9% to 27% of individuals have little or no response to these drugs. In this article, we investigated the efficacy of GLP-1 RA therapy among adults with type 1 diabetes and obesity likely related to genetic mutations compared with obesity likely unrelated to genetic mutations. METHODS: In this retrospective study, we compared body weight and glycated hemoglobin (HbA1c) change with the use of GLP-1 RA therapy (including a dual agonist, Tirzepatide) over six months among adults with type 1 diabetes and obesity likely (n = 11, median age 39.5 years with a median BMI of 43.0 kg/m2) versus unlikely related to genetic mutation(s) (n = 15, median age 45.8 years with a median BMI of 38.7 kg/m2). RESULTS: Six months of GLP-1 RA treatment resulted in a numerically lower reduction of weight (-5.75 ± 9.46 kg vs -8.65 ± 9.36 kg, P = .44) and HbA1c (-0.28 ± 0.96% vs -0.43 ± 0.57%, P = .64) among individuals with obesity likely versus unlikely related to a genetic mutation(s), respectively. Fewer individuals with genetic obesity met goal weight loss ≥5% or HbA1c decrease ≥0.4% than did individuals with obesity unlikely related to a genetic cause (36.4% vs 80.0%, P = .04). CONCLUSIONS: The weight loss and glycemic lowering effects of GLP-1 RA therapy may be decreased in people with type 1 diabetes and obesity likely related to genetic causes. Further research is needed to understand GLP-1 RA mechanisms via energy regulating genes.

10.
J Bone Miner Res ; 39(6): 683-687, 2024 Jul 23.
Article in English | MEDLINE | ID: mdl-38547399

ABSTRACT

Factors affecting intrauterine environment exerts influence on skeletal health and fracture risk in later life. Diabetes during pregnancy is known to influence birth weight and is associated with fetal overgrowth. However, the effects of maternal diabetes on fracture risk in offspring is unknown. This study was aimed to evaluate the association between maternal diabetes and fracture risk in offspring. Using population-based administrative health data for Manitoba, Canada, we identified deliveries complicated by gestational diabetes and type 2 diabetes between April 1, 1980, and March 31, 2020. The cohort was followed for a median of 15.8 yr. The primary outcome was any incident fracture in offspring. Secondary outcomes were long bone upper extremity fracture, long bone lower extremity fracture, vertebral fracture, and any non-trauma fractures. Cox proportional hazard regression models were used to estimate fracture risk in offspring by maternal diabetes status adjusted for relevant covariates. Of the 585 176 deliveries, 26 397 offspring were born to women with diabetes (3.0% gestational diabetes and 1.5% type 2 diabetes), and 558 779 were born to women without diabetes. The adjusted risk for any fracture was 7% (hazard ratio, 1.07; 95% CI, 2.7-11.5%) higher in the offspring of mothers with diabetes than offspring of mothers without diabetes. Types of fractures were similar between the 2 groups with a predominance of long bone upper extremity fractures. In conclusion, maternal diabetes was associated with a modest increase in fracture risk in offspring. Longitudinal prospective studies are needed to understand intrauterine and postnatal factors that may influence fracture risk in the offspring of mothers with diabetes.


Subject(s)
Diabetes Mellitus, Type 2 , Diabetes, Gestational , Fractures, Bone , Humans , Female , Pregnancy , Fractures, Bone/epidemiology , Diabetes, Gestational/epidemiology , Adult , Risk Factors , Diabetes Mellitus, Type 2/epidemiology , Male , Adolescent , Manitoba/epidemiology
11.
J Diabetes Sci Technol ; : 19322968241234072, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38439656

ABSTRACT

BACKGROUND: Control-IQ technology version 1.5 allows for a wider range of weight and total daily insulin (TDI) entry, in addition to other changes to enhance performance for users with high basal rates. This study evaluated the safety and performance of the updated Control-IQ system for users with basal rates >3 units/h and high TDI in a multicenter, single arm, prospective study. METHODS: Adults with type 1 diabetes (T1D) using continuous subcutaneous insulin infusion (CSII) and at least one basal rate over 3 units/h (N = 34, mean age = 39.9 years, 41.2% female, diabetes duration = 21.8 years) used the t:slim X2 insulin pump with Control-IQ technology version 1.5 for 13 weeks. Primary outcome was safety events (severe hypoglycemia and diabetic ketoacidosis (DKA)). Central laboratory hemoglobin A1c (HbA1c) was measured at system initiation and 13 weeks. Participants continued using glucagon-like peptide-1 (GLP-1) receptor agonists, sodium-glucose transport protein 2 (SGLT-2) inhibitors, or other medications for glycemic control and/or weight loss if on a stable dose. RESULTS: All 34 participants completed the study. Fifteen participants used a basal rate >3 units/h for all 24 hours of the day. Nine participants used >300 units TDI on at least one day during the study. There were no severe hypoglycemia or DKA events. Time in range 70-180 mg/dL was 64.8% over the 13 weeks, with 1.0% time <70 mg/dL. Hemoglobin A1c decreased from 7.69% at baseline to 6.87% at 13 weeks (-0.82%, P < .001). CONCLUSIONS: Control-IQ technology version 1.5, with wider range of weight and TDI input and enhancements for users with high insulin requirements, was safe in individuals with T1D in this study.

13.
J Diabetes Sci Technol ; : 19322968241232709, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38420944

ABSTRACT

BACKGROUND: SAR341402 insulin aspart (SAR-Asp) is a rapid-acting insulin analog developed as an interchangeable biosimilar to the marketed insulin aspart reference product (NovoLog; NN-Asp). GEMELLI X was a randomized controlled trial to assess outcomes with a biosimilar in line with the US Food and Drug Administration requirements for designation as an interchangeable biosimilar. This report assessed whether multiple switches between SAR-Asp and NN-Asp lead to equivalent safety and efficacy compared with continuous use of NN-Asp in adults with type 1 diabetes (T1D) treated with multiple daily injections, using once-daily insulin glargine U100 (Lantus) as the basal insulin. METHODS: This open-label randomized (1:1), parallel-group, phase 3 trial compared four × four weeks of alternating use of individually titrated SAR-Asp and NN-Asp (NN-Asp for first four weeks, SAR-Asp in last four weeks; switching group) vs 16 weeks of continuous use of NN-Asp (nonswitching group). End points included pharmacokinetics, immunogenicity, adverse events, hypoglycemia, insulin dose, and change in efficacy parameters. RESULTS: Of the 210 patients randomized, 200 (95.5%) completed the trial. Patients assigned to switching group (n = 104) and nonswitching group (n = 106) showed similar safety and tolerability, including anti-insulin aspart antibody responses, adverse events, and hypoglycemia. At week 16, there was no relevant difference between switching vs nonswitching groups in the change from baseline in glycated hemoglobin (least square [LS] mean difference = 0.05% [95% confidence interval [CI] = -0.13, 0.22]; 0.50 mmol/mol [-1.40, 2.39]), fasting plasma glucose (LS mean difference = 0.23 mmol/L [95% CI = -1.08, 1.53]; 4.12 mg/dL [-19.38, 27.62]), and changes in insulin dosages. CONCLUSIONS: Alternating doses of SAR-Asp and NN-Asp compared with continuous use of NN-Asp showed similar safety, immunogenicity, and clinical efficacy in adults with T1D. This study supports interchangeability between SAR-Asp and NN-Asp in T1D management.

14.
J Diabetes Sci Technol ; : 19322968231223991, 2024 Feb 05.
Article in English | MEDLINE | ID: mdl-38317405

ABSTRACT

BACKGROUND: Tirzepatide is approved by the United States Food and Drug Administration (FDA) for the management of type 2 diabetes. The efficacy and safety of this drug have not been studied in people with type 1 diabetes (T1D). METHODS: In this single-center, retrospective, observational study, hemoglobin A1C (HbA1c), weight, body mass index (BMI), and continuous glucose monitoring (CGM) data were collected from electronic health records of adults with T1D at initiation of tirzepatide and at subsequent clinic visits over 8 months. Primary outcomes were reduction in HbA1c and percent change in body weight and secondary outcomes were change in CGM metrics and BMI over 8 months from baseline. RESULTS: The mean (±SD) age of the 26 adults (54% female) with T1D was 42 ± 8 years with a mean BMI of 36.7 ± 5.3 kg/m2. There was significant reduction in HbA1c by 0.45% at 3 months and 0.59% at 8 months, and a significant reduction in body weight by 3.4%, 10.5%, and 10.1% at 3, 6, and 8 months after starting tirzepatide. Time in target range (TIR = 70-180 mg/dL) and time in tight target range (TITR = 70-140 mg/dL) increased (+12.6%, P = .002; +10.7%, P = .0016, respectively) and time above range (TAR >180 mg/dL) decreased (-12.6%, P = .002) at 3 months, and these changes were sustained over 8 months. The drug was relatively safe and well tolerated with only 2 patients discontinuing the medication. CONCLUSIONS: Tirzepatide significantly reduced HbA1c and body weight in adults with T1D. A randomized controlled trial is needed to establish efficacy and safety of this drug in T1D.

15.
J Diabetes Sci Technol ; : 19322968241229074, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38323362

ABSTRACT

BACKGROUND: Optimization of automated insulin delivery (AID) settings is required to achieve desirable glycemic outcomes. We evaluated safety and efficacy of a computerized system to initialize and adjust insulin delivery settings for the t:slim X2 insulin pump with Control-IQ technology in adults with type 1 diabetes (T1D). METHODS: After a 2-week continuous glucose monitoring (CGM) run-in period, adults with T1D using multiple daily injections (MDI) (N = 33, mean age 36.1 years, 57.6% female, diabetes duration 19.7 years) were transitioned to 13 weeks of Control-IQ technology usage. A computerized algorithm generated recommendations for initial pump settings (basal rate, insulin-to-carbohydrate ratio, and correction factor) and weekly follow-up settings to optimize glycemic outcomes. Physicians could override the automated settings changes for safety concerns. RESULTS: Time in range 70 to 180 mg/dL improved from 45.7% during run-in to 69.1% during the last 30 days of Control-IQ use, a median improvement of 18.8% (95% confidence interval [CI]: 13.6-23.9, P < .001). This improvement was evident early in the study and was sustained over 13 weeks. Time <70 mg/dL showed a gradual decreasing trend over time. Percentage of participants achieving HbA1c <7% went from zero at baseline to 55% at study end (P < .001). Only six of the 318 automated settings adaptations (1.9%) were overridden by study investigators. CONCLUSIONS: Computerized initiation and adaptation of Control-IQ technology settings from baseline MDI therapy was safe in adults with T1D. The use of this simplified system for onboarding and optimizing Control-IQ technology may be useful to increase uptake of AID and reduce staff and patient burden in clinical care.

16.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37850941

ABSTRACT

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Subject(s)
Diabetes Mellitus, Type 1 , Adult , Child , Humans , Adolescent , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Glycated Hemoglobin , Insulin Infusion Systems , Blood Glucose , Blood Glucose Self-Monitoring
17.
Diabetes Obes Metab ; 26(2): 540-547, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37880868

ABSTRACT

AIM: To assess whether multiple switches between SAR341402 biosimilar insulin aspart (SAR-Asp) and the insulin aspart reference product (NovoLog; NN-Asp) leads to equivalent pharmacokinetic (PK) exposure compared with continuous use of NN-Asp in adults with type 1 diabetes (T1D). MATERIALS AND METHODS: This multicentre, open-label, phase 3 study randomized (1:1) 210 subjects with T1D treated with once-daily insulin glargine U100 as basal insulin to four 4-week periods of alternating multiple daily injections of SAR-Asp and NN-Asp (NN-Asp for the first 4 weeks, SAR-Asp in the last 4 weeks; switching group) versus 16 weeks of continuous NN-Asp (non-switching group). At week 16, a single dose (0.15 U/kg) of SAR-Asp in the switching group (n = 95) or NN-Asp in the non-switching group (n = 105) was given in the morning before breakfast. Primary PK endpoints were area under the plasma concentration curve (AUC) and maximum plasma concentration (Cmax ) of SAR-Asp versus NN-Asp after the single dose at week 16. RESULTS: The extent of PK exposure was similar between the two treatments (SAR-Asp in the switching group and NN-Asp in the non-switching group) at week 16, with point estimates of treatment ratios close to 1. The 90% confidence intervals for AUC treatment ratios were contained within 0.8-1.25. For Cmax in the primary analysis set, the upper confidence limit was 1.32. This was because of the profiles of three participants with implausible high values. A prespecified sensitivity analysis excluding implausible values showed results contained within 0.8-1.25. CONCLUSIONS: PK exposure of SAR-Asp (switching group) and reference NN-Asp (non-switching group) were similar, supporting interchangeability between these two insulin aspart products.


Subject(s)
Biosimilar Pharmaceuticals , Diabetes Mellitus, Type 1 , Adult , Humans , Biosimilar Pharmaceuticals/administration & dosage , Biosimilar Pharmaceuticals/pharmacokinetics , Blood Glucose , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/pharmacokinetics , Insulin/pharmacokinetics , Insulin Aspart/pharmacokinetics , Insulin Glargine/pharmacokinetics
18.
Diabetes Technol Ther ; 26(4): 246-251, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38133643

ABSTRACT

Abstract Objective: To evaluate the association between continuous glucose monitoring (CGM)-based time in various ranges and the subsequent development of diabetic retinopathy (incident DR) in adults with type 1 diabetes. Methods: Between June 2018 and March 2022, adults with type 1 diabetes with incident DR or no retinopathy (control) were identified. CGM data were collected retrospectively for up to 7 years before the date of eye examination defining incident DR or control. Associations between incident DR and CGM metrics were evaluated using logistic regression models. Results: This analysis included 71 adults with incident DR (mean age 27 years, 52% females, and mean diabetes duration 15 years) and 92 adults without DR (mean age 38 years, 48% females, and mean diabetes duration 20 years). Adjusting for age, diabetes duration, and CGM type, each 0.5% increase in glycated hemoglobin (HbA1c), 10 mg/dL increase in mean glucose, 5% decrease in time in target range 70-180 mg/dL (TIR), 5% decrease in time in tight target range 70-140 mg/dL (TITR), and 5% increase in time above 180 mg/dL (TAR) were associated with 24%, 22%, 18%, 28%, and 20% increase in odds of incident DR, respectively. Spearman correlations of TIR, TITR, TAR, and mean glucose with each other were all ≥0.97. Conclusion: Similar to HbA1c, TIR, TITR, TAR, and mean glucose were associated with increased risk for incident DR in adults with type 1 diabetes. These CGM metrics are highly correlated indicating that they provide similar information on glycemic control and diabetic retinopathy risk.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetic Retinopathy , Adult , Female , Humans , Male , Diabetes Mellitus, Type 1/complications , Glycated Hemoglobin , Blood Glucose , Longitudinal Studies , Diabetic Retinopathy/epidemiology , Diabetic Retinopathy/etiology , Diabetic Retinopathy/diagnosis , Blood Glucose Self-Monitoring/adverse effects , Retrospective Studies
19.
JBMR Plus ; 7(11): e10831, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38025041

ABSTRACT

Compromised bone structural and mechanical properties are implicated in the increased fracture risk in type 1 diabetes (T1D). We investigated bone structure and turnover by histomorphometry in postmenopausal women with T1D and controls without diabetes using tetracycline double-labeled transiliac bone biopsy. After in vivo tetracycline double labeling, postmenopausal women with T1D of at least 10 years and without diabetes underwent transiliac bone biopsy. An expert blinded to the study group performed histomorphometry. Static and dynamic histomorphometry measurements were performed and compared between the two groups. The analysis included 9 postmenopausal women with T1D (mean age 58.4 ± 7.1 years with 37.9 ± 10.9 years of diabetes and HbA1c 7.1% ± 0.4%) and 7 postmenopausal women without diabetes (mean age 60.9 ± 3.3 years and HbA1c 5.4% ± 0.2%). There were no significant differences in serum PTH (38.6 ± 8.1 versus 51.9 ± 23.9 pg/mL), CTX (0.4 ± 0.2 versus 0.51 ± 0.34 ng/mL), or P1NP (64.5 ± 26.2 versus 87.3 ± 45.3 ng/mL). Serum 25-hydroxyvitamin D levels were higher in T1D than in controls (53.1 ± 20.8 versus 30.9 ± 8.2 ng/mL, p < 0.05). Bone structure metrics (bone volume, trabecular thickness, trabecular number, and cortical thickness) were similar between the groups. Indices of bone formation (osteoid volume, osteoid surface, and bone formation rate) were 40% lower in T1D and associated with lower activation frequency. However, the differences in bone formation were not statistically significant. Long-standing T1D may affect bone turnover, mainly bone formation, without significantly affecting bone structure. Further research is needed to understand bone turnover and factors affecting bone turnover in people with T1D. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC. on behalf of American Society for Bone and Mineral Research.

20.
JBMR Plus ; 7(11): e10824, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38025043

ABSTRACT

Monogenic diabetes, including mitochondrial diabetes, constitutes 1% to 3% of all diabetes. Although there is an increased interest in understanding the mechanisms of bone fragility in people with diabetes, skeletal research is mostly focused on type 1 and type 2 diabetes. Little is known on skeletal health among people with mitochondrial diabetes. In this single-center study, we presented clinical characteristics of individuals with mitochondrial diabetes and clinical diagnosis of osteoporosis. Of 10 patients with mitochondrial diabetes, 4 (40%) had a clinical diagnosis of osteoporosis. Patients with osteoporosis were older, had lower body mass index, longer diabetes duration, lower fasting C-peptide, and presence of multiple comorbidities compared with patients without osteoporosis. In addition to our cases, we also systematically reviewed literature on skeletal health in people with mitochondrial diabetes and provided an overview of potential factors affecting skeletal health and future clinical and research directions to improve the care of people with mitochondrial disease. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

SELECTION OF CITATIONS
SEARCH DETAIL