Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
Add more filters










Publication year range
1.
Micromachines (Basel) ; 14(10)2023 Oct 18.
Article in English | MEDLINE | ID: mdl-37893379

ABSTRACT

Atmospheric pressure measurements based on microelectromechanical systems (MEMSs) can extend accessibility to altitude information. A differential pressure sensor using a thin cantilever and an air chamber is a promising sensing element for sub-centimeter resolution. However, its vulnerability to wind and the lack of height estimation algorithms for real-time operation are issues that remain to be solved. We propose a sensor "cap" that cancels the wind effect and noise by utilizing the airflow around a sphere. A set of holes on the spherical cap transmits only the atmospheric pressure to the sensor. In addition, we have developed a height estimation method based on a discrete transfer function model. As a result, both dynamic pressure and noise are suppressed, and height is estimated under a 5 m/s wind, reconstructing the trajectory with an estimation error of 2.8 cm. The developed sensing system enhances height information in outdoor applications such as unmanned aerial vehicles and wave height measurements.

2.
Sensors (Basel) ; 23(7)2023 Mar 23.
Article in English | MEDLINE | ID: mdl-37050430

ABSTRACT

It is expected that human iPS cell-derived cardiomyocytes (hiPSC-CMs) can be used to treat serious heart diseases. However, the properties and functions of human adult cardiomyocytes and hiPSC-CMs, including cell maturation, differ. In this study, we focused on the temperature dependence of hiPSC-CMs by integrating the temperature regulation system into our sensor platform, which can directly and quantitatively measure their mechanical motion. We measured the beating frequency of hiPSC-CMs at different environmental temperatures and found that the beating frequency increased as the temperature increased. Although the rate at which the beating frequency increased with temperature varied, the temperature at which the beating stopped was relatively stable at approximately 20 °C. The stopping of beating at this temperature was stable, even in immature hiPSC-CMs, and was considered to be a primitive property of cardiomyocytes.


Subject(s)
Induced Pluripotent Stem Cells , Micro-Electrical-Mechanical Systems , Adult , Humans , Induced Pluripotent Stem Cells/physiology , Temperature , Cell Differentiation , Myocytes, Cardiac/physiology , Cells, Cultured
3.
Minim Invasive Ther Allied Technol ; 31(1): 28-33, 2022 Jan.
Article in English | MEDLINE | ID: mdl-32468887

ABSTRACT

INTRODUCTION: As the benefits of minimally invasive surgery are recognized, the rate of laparoscopic liver resection (LLR) is rapidly increasing. Liver tissue is fragile compared to tissue of the stomach and colon. In endoscopic and robotic surgery, sufficient tactile sensation is yet to be obtained. Therefore, it is necessary to measure and indicate the grip force of forceps during surgery. We developed a new device consisting of force sensors and investigated its grip force and the resulting histological damage to liver tissue. MATERIAL AND METHODS: We measured the grip force generated during laparoscopic surgery in pigs using the forceps with pressure sensors developed by us. Throughout the hepatectomy, we measured the grip force generated by the forceps in real time. We investigated the histological damage to the liver caused by using the forceps with different grip forces. RESULTS: The subject produced a mean grip force of 1.75 N during the procedures. The maximum grip force was 3.38 N. By grasping the tissues of the liver with forceps, bleeding and destruction of the hepatic lobules were observed in a manner dependent on increasing grip force. CONCLUSION: The new device is necessary for preventing liver damage in laparoscopic hepatic resection.


Subject(s)
Hepatectomy , Laparoscopy , Animals , Hand Strength , Hepatectomy/adverse effects , Hepatectomy/instrumentation , Laparoscopy/adverse effects , Laparoscopy/instrumentation , Swine
5.
Sci Rep ; 11(1): 13570, 2021 06 30.
Article in English | MEDLINE | ID: mdl-34193889

ABSTRACT

Neuronal activities underlying a percept are constrained by the physics of sensory signals. In the tactile sense such constraints are frictional stick-slip events, occurring, amongst other vibrotactile features, when tactile sensors are in contact with objects. We reveal new biomechanical phenomena about the transmission of these microNewton forces at the tip of a rat's whisker, where they occur, to the base where they engage primary afferents. Using high resolution videography and accurate measurement of axial and normal forces at the follicle, we show that the conical and curved rat whisker acts as a sign-converting amplification filter for moment to robustly engage primary afferents. Furthermore, we present a model based on geometrically nonlinear Cosserat rod theory and a friction model that recreates the observed whole-beam whisker dynamics. The model quantifies the relation between kinematics (positions and velocities) and dynamic variables (forces and moments). Thus, only videographic assessment of acceleration is required to estimate forces and moments measured by the primary afferents. Our study highlights how sensory systems deal with complex physical constraints of perceptual targets and sensors.


Subject(s)
Touch Perception/physiology , Touch/physiology , Vibrissae/physiology , Animals , Male , Rats , Rats, Sprague-Dawley , Vibrissae/anatomy & histology
6.
Micromachines (Basel) ; 12(3)2021 Mar 08.
Article in English | MEDLINE | ID: mdl-33800214

ABSTRACT

A tensor sensor can be used to measure deformations in an object that are not visible to the naked eye by detecting the stress change inside the object. Such sensors have a wide range of application. For example, a tensor sensor can be used to predict fatigue in building materials by detecting the stress change inside the materials, thereby preventing accidents. In this case, a sensor of small size that can measure all nine components of the tensor is required. In this study, a tensor sensor consisting of highly sensitive piezoresistive beams and a cantilever to measure all of the tensor components was developed using MEMS processes. The designed sensor had dimensions of 2.0 mm by 2.0 mm by 0.3 mm (length by width by thickness). The sensor chip was embedded in a 15 mm3 cubic polydimethylsiloxane (PDMS) (polydimethylsiloxane) elastic body and then calibrated to verify the sensor response to the stress tensor. We demonstrated that 6-axis normal and shear Cauchy stresses with 5 kPa in magnitudes can be measured by using the fabricated sensor.

7.
Sensors (Basel) ; 20(4)2020 Feb 15.
Article in English | MEDLINE | ID: mdl-32075243

ABSTRACT

This paper reports on a microelectromechanical systems (MEMS)-based sensor for pulse wave measurement. The sensor consists of an air chamber with a thin membrane and a 300-nm thick piezoresistive cantilever placed inside the chamber. When the membrane of the chamber is in contact with the skin above a vessel of a subject, the pulse wave of the subject causes the membrane to deform, leading to a change in the chamber pressure. This pressure change results in bending of the cantilever and change in the resistance of the cantilever, hence the pulse wave of the subject can be measured by monitoring the resistance of the cantilever. In this paper, we report the sensor design and fabrication, and demonstrate the measurement of the pulse wave using the fabricated sensor. Finally, measurement of the pulse wave velocity (PWV) is demonstrated by simultaneously measuring pulse waves at two points using the two fabricated sensor devices. Furthermore, the effect of breath holding on PWV is investigated. We showed that the proposed sensor can be used to continuously measure the PWV for each pulse, which indicates the possibility of using the sensor for continuous blood pressure measurement.

8.
Micromachines (Basel) ; 10(8)2019 Aug 09.
Article in English | MEDLINE | ID: mdl-31395794

ABSTRACT

In this study, we analyzed the vertical driving performance of multiple connected magnetic wheel-driven microrobots when moving up and down a small cylinder that simulated a pipe. The dynamics of pipe climbing by the magnetic wheel-driven microrobot were analyzed considering the magnetic attraction force and slip; a vertical climbing simulator was developed considering the hoop force and external force from the adjacent microrobots to determine the magnetic attraction force required for multiple connected microrobot pipe climbing. A prototype of an independent vertical climbing microrobot, 5 mm long, 9 mm wide, and 6.5 mm high, and prototypes of 10 microrobots were manufactured to evaluate the vertical driving performance. The usefulness was verified by showing that three driving microrobots can move seven non-driving microrobots comprising 60% of their own weight up and down along a small cylinder.

9.
Opt Express ; 27(13): 17763-17770, 2019 Jun 24.
Article in English | MEDLINE | ID: mdl-31252731

ABSTRACT

A current detection surface plasmon resonance (SPR) sensor with an Au grating on an n-Si wafer was proposed. SPR excitation light is illuminated from the backside of the device and diffracted by the grating. Since the diffraction provides matching conditions, SPR can be coupled to the Au/analyte interface. Since the coupled SPR excites free electrons on the Au surface, the SPR can be detected as a current signal by a Schottky barrier diode formed on the Au/n-Si interface. The obtained angular current spectrum showed clear agreement with SPR coupling theory, thereby confirming that the sample on the Au surface can be electrically detected using the proposed sensor.

10.
Micromachines (Basel) ; 10(6)2019 Jun 06.
Article in English | MEDLINE | ID: mdl-31174323

ABSTRACT

This study investigated slip and magnetic attraction effects in a skid-steered magnetic-wheeled microrobot. The dynamics of the microrobot were derived by considering the slip and magnetic attraction of the wheels. In addition, the slip characteristics of the magnetic wheels were measured using an evaluation apparatus built for this purpose. A simulation program for driving performance was developed as well. Simulations indicated that the turning characteristics of the skid-steered wheeled microrobot degrade because the gripping force decreases due to the decrease in weight with decreasing size. However, the turning characteristics of a skid-steered microrobot can be improved with the magnetic attraction of magnetic wheels. A 5 mm × 9 mm × 6.5 mm skid-steered microrobot with four magnetic wheels was fabricated, and the measured performance was consistent with the simulation results. The differences in driving performance were clarified between a microrobot with column-type magnetic wheels and one with barrel-type magnetic wheels, as well as between forward and backward motion.

11.
Sensors (Basel) ; 18(2)2018 Jan 30.
Article in English | MEDLINE | ID: mdl-29385726

ABSTRACT

Ethanol concentration was quantified by the use of a compact surface plasmon resonance (SPR) system, which electrically detects hot electrons via a Schottky barrier. Although it is well known that SPR can be used as bio/chemical sensors, implementation is not necessarily practical, due to the size and cost impediments associated with a system with variable wavelength or angle of incidence. However, scanning capability is not a prerequisite if the objective is to use SPR in a sensor. It is possible to build a small, inexpensive SPR sensor if the optics have no moving parts and a Schottky barrier is used for electrical current detection in place of a photodetector. This article reports on the design and performance of such a novel SPR sensor, and its application for quantifying ethanol concentration. As the concentration of ethanol is increased, the change in the angle dependence of the SPR current is observed. This change can be understood as a superposition of contributions of SPR coupled with the +3rd- and -3rd-order diffraction. Moreover, real-time monitoring of ethanol concentration was demonstrated using the proposed SPR system.

12.
Sensors (Basel) ; 17(10)2017 Oct 24.
Article in English | MEDLINE | ID: mdl-29064385

ABSTRACT

We measured the three-axis ground reaction force (GRF) distribution during straight walking. Small three-axis force sensors composed of rubber and sensor chips were fabricated and calibrated. After sensor calibration, 16 force sensors were attached to the left shoe. The three-axis force distribution during straight walking was measured, and the local features of the three-axis force under the sole of the shoe were analyzed. The heel area played a role in receiving the braking force, the base area of the fourth and fifth toes applied little vertical or shear force, the base area of the second and third toes generated a portion of the propulsive force and received a large vertical force, and the base area of the big toe helped move the body's center of mass to the other foot. The results demonstrate that measuring the three-axis GRF distribution is useful for a detailed analysis of bipedal locomotion.


Subject(s)
Biosensing Techniques/instrumentation , Walking/physiology , Biomechanical Phenomena , Foot , Shoes
13.
Opt Express ; 24(22): 25797-25804, 2016 Oct 31.
Article in English | MEDLINE | ID: mdl-27828514

ABSTRACT

We present a near-infrared (NIR) spectrum measurement method using a Schottky photodetector enhanced by surface plasmon resonance (SPR). An Au grating was fabricated on an n-type silicon wafer to form a Schottky barrier and act as an SPR coupler. The resulting photodetector provides wavelength-selective photodetection depending on the SPR coupling angle. A matrix was pre-calculated to describe this characteristic. The spectrum was obtained from this matrix and the measured photocurrents at various SPR coupling angles. Light with single and multiple wavelengths was tested. Comparative measurements showed that our method is able to detect spectra with a wavelength resolution comparable to that of a commercial spectrometer.

14.
Langmuir ; 32(37): 9523-9, 2016 09 20.
Article in English | MEDLINE | ID: mdl-27603591

ABSTRACT

Surfaces covered with hydrophobic micro-/nanoscale textures can allow water droplets to slide easily because of low contact angle hysteresis. In contrast to the case of a droplet sliding on a smooth surface, when a droplet slides on a textured surface, it must recede from the textures at its rear edge and the resultant depinning events induce a capillary wave on the surface of the droplet. Although this depinning-induced capillary wave can be observed to some extent through high-speed imaging, important parameters of the wave, such as the wavelength and frequency, and the factors that determine these parameters are not fully understood. We report direct measurements of this depinning-induced capillary wave using microelectromechanical systems (MEMS)-based force sensors fabricated on a textured surface. Such sensor measurements reveal the frequency of the vibration occurring on the surface of the droplet, from which it is possible to calculate the wavelength of the capillary wave. We show that the frequency and wavelength of the depinning-induced capillary wave during the sliding of a water droplet on a micropillar array depend upon neither the size of the droplet nor its sliding velocity. However, the frequency (wavelength) decreases (increases) as the pitch of the micropillar array increases. We argue that the wavelength of the depinning-induced capillary wave is equal to the maximum length of the liquid bridges that develop at the micropillars before depinning. This hypothesis is confirmed by comparing the wavelengths obtained from the sensor measurements to the maximum liquid-bridge lengths calculated from observations using a high-speed camera.

15.
Sensors (Basel) ; 16(5)2016 May 18.
Article in English | MEDLINE | ID: mdl-27213374

ABSTRACT

This paper reports on a tactile sensor using piezoresistive beams for detection of the coefficient of static friction merely by pressing the sensor against an object. The sensor chip is composed of three pairs of piezoresistive beams arranged in parallel and embedded in an elastomer; this sensor is able to measure the vertical and lateral strains of the elastomer. The coefficient of static friction is estimated from the ratio of the fractional resistance changes corresponding to the sensing elements of vertical and lateral strains when the sensor is in contact with an object surface. We applied a normal force on the sensor surface through objects with coefficients of static friction ranging from 0.2 to 1.1. The fractional resistance changes corresponding to vertical and lateral strains were proportional to the applied force. Furthermore, the relationship between these responses changed according to the coefficients of static friction. The experimental result indicated the proposed sensor could determine the coefficient of static friction before a global slip occurs.

16.
Microsyst Nanoeng ; 2: 16049, 2016.
Article in English | MEDLINE | ID: mdl-31057837

ABSTRACT

This paper describes a theoretical estimation of the geometry of negative epoxy-resist microneedles prepared via inclined/rotated ultraviolet (UV) lithography based on spatially controlled UV exposure doses. In comparison with other methods based on UV lithography, the present method can create microneedle structures with high scalability. When negative photoresist is exposed to inclined/rotated UV through circular mask patterns, a three-dimensional, needle-shaped distribution of the exposure dose forms in the irradiated region. Controlling the inclination angles and the exposure dose modifies the photo-polymerized portion of the photoresist, thus allowing the variation of the heights and contours of microneedles formed by using the same mask patterns. In an experimental study, the dimensions of the fabricated needles agreed well with the theoretical predictions for varying inclination angles and exposure doses. These results demonstrate that our theoretical approach can provide a simple route for fabricating microneedles with on-demand geometry. The fabricated microneedles can be used as solid microneedles or as a mold master for dissolving microneedles, thus simplifying the microneedle fabrication process. We envision that this method can improve fabrication accuracy and reduce fabrication cost and time, thereby facilitating the practical applications of microneedle-based drug delivery technology.

17.
Nat Commun ; 6: 8422, 2015 Oct 01.
Article in English | MEDLINE | ID: mdl-26423346

ABSTRACT

Active modulation of the polarization states of terahertz light is indispensable for polarization-sensitive spectroscopy, having important applications such as non-contact Hall measurements, vibrational circular dichroism measurements and anisotropy imaging. In the terahertz region, the lack of a polarization modulator similar to a photoelastic modulator in the visible range hampers expansion of such spectroscopy. A terahertz chiral metamaterial has a huge optical activity unavailable in nature; nevertheless, its modulation is still challenging. Here we demonstrate a handedness-switchable chiral metamaterial for polarization modulation employing vertically deformable Micro Electro Mechanical Systems. Vertical deformation of a planar spiral by a pneumatic force creates a three-dimensional spiral. Enantiomeric switching is realized by selecting the deformation direction, where the polarity of the optical activity is altered while maintaining the spectral shape. A polarization rotation as high as 28° is experimentally observed, thus providing a practical and compact polarization modulator for the terahertz range.

18.
Opt Express ; 23(20): 26243-51, 2015 Oct 05.
Article in English | MEDLINE | ID: mdl-26480137

ABSTRACT

We propose a reconfigurable terahertz (THz) metamaterial that can control the transmittance by out-of-plane actuation with changing the sub-micron gap distance between electrically coupled metamaterial elements. By using the out-of-plane actuation, it was possible to avoid contact between the coupled metamaterial elements across the small initial gap during the adjustment of the gap size. THz spectroscopy was performed during actuation, and the transmission dip frequency was confirmed to be tunable from 0.82 to 0.92 THz for one linear polarization state and from 0.80 to 0.91 THz for the other linear polarization; the two polarizations were orthogonal. The proposed approach will contribute to the development of tunable metamaterials based on structural deformations.

19.
Lab Chip ; 15(18): 3670-6, 2015 Sep 21.
Article in English | MEDLINE | ID: mdl-26224295

ABSTRACT

We report a simple technique to measure the free vibration of microlitre-sized droplets using an array of thirteen MEMS-based piezoresistive cantilevers and demonstrate its application for the measurement of viscosity. Because the damping of the free vibration of a liquid droplet is known to be affected by the viscosity of the liquid, measuring the vibration of a droplet allows the viscosity to be estimated from a dilute sample volume. However, conventional methods to measure the droplet vibration require sophisticated apparatuses, which hinder the development of a portable viscometer. Here, we show that MEMS-based piezoresistive cantilevers can be an excellent tool to measure the vibration of a sessile droplet due to the high sensitivity and simplicity of the readout scheme. Using the cantilever array, we analyse the normal force distribution on the contact area of a sessile droplet in the static state and during the vibration. Next, we show that the viscosity (from ~1-30 mPa s) can be estimated within an error of less than 10% from the attenuation rate of the cantilever output during the tapping-induced vibration of small droplets (~2.4 µL). In addition to the advantage of the small sample volume, the proposed viscometer has simple operation and readout schemes, which are desirable for many applications, including point-of-care testing and drug development.

20.
Opt Lett ; 38(11): 1811-3, 2013 Jun 01.
Article in English | MEDLINE | ID: mdl-23722752

ABSTRACT

We propose a method to measure light transmittance of layered metamaterials by placing the metamaterials directly on a Si photodiode. Our measurement method enables the direct detection of transmitted light that appears as an evanescent wave in natural materials. Here, we report the transmittance measurements of a typical metamaterial using this method. The metamaterial was composed of Ag/Al(2)O(3) layers and was fabricated by direct evaporation on the Si photodiode. The measured transmittance agrees with the simulated transmittance. Our results confirmed that this measurement method can determine the transmittance properties of metamaterials and that it is applicable to other types of metamaterials.

SELECTION OF CITATIONS
SEARCH DETAIL
...