Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Rofo ; 2024 Jul 22.
Article in English, German | MEDLINE | ID: mdl-39038457

ABSTRACT

PURPOSE: The prevalent coronavirus disease 2019 (COVID-19) pandemic has spread throughout the world and is considered a serious threat to global health. The prognostic role of thoracic lymphadenopathy in COVID-19 is unclear. The aim of the present meta-analysis was to analyze the prognostic role of thoracic lymphadenopathy for the prediction of 30-day mortality in patients with COVID-19. MATERIALS AND METHODS: The MEDLINE library, Cochrane, and SCOPUS databases were screened for associations between CT-defined features and mortality in COVID-19 patients up to June 2021. In total, 21 studies were included in the present analysis. The quality of the included studies was assessed by the Newcastle-Ottawa Scale. The meta-analysis was performed using RevMan 5.3. Heterogeneity was calculated by means of the inconsistency index I2. DerSimonian and Laird random-effect models with inverse variance weights were performed without any further correction. RESULTS: The included studies comprised 4621 patients. The prevalence of thoracic lymphadenopathy varied between 1 % and 73.4 %. The pooled prevalence was 16.7 %, 95 % CI = (15.6 %; 17.8 %). The hospital mortality was higher in patients with thoracic lymphadenopathy (34.7 %) than in patients without (20.0 %). The pooled odds ratio for the influence of thoracic lymphadenopathy on mortality was 2.13 (95 % CI = [1.80-2.52], p < 0.001). CONCLUSION: The prevalence of thoracic lymphadenopathy in COVID-19 is 16.7 %. The presence of thoracic lymphadenopathy is associated with an approximately twofold increase in the risk for hospital mortality in COVID-19. KEY POINTS: · The prevalence of lymphadenopathy in COVID-19 is 16.7 %.. · Patients with lymphadenopathy in COVID-19 have a higher risk of mortality during hospitalization.. · Lymphadenopathy nearly doubles mortality and plays an important prognostic role.. CITATION FORMAT: · Bucher AM, Sieren M, Meinel F et al. Prevalence and prognostic role of thoracic lymphadenopathy in Covid-19. Fortschr Röntgenstr 2024; DOI: 10.1055/a-2293-8132.

2.
Eur J Radiol ; 176: 111534, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38820951

ABSTRACT

PURPOSE: Radiological reporting is transitioning to quantitative analysis, requiring large-scale multi-center validation of biomarkers. A major prerequisite and bottleneck for this task is the voxelwise annotation of image data, which is time-consuming for large cohorts. In this study, we propose an iterative training workflow to support and facilitate such segmentation tasks, specifically for high-resolution thoracic CT data. METHODS: Our study included 132 thoracic CT scans from clinical practice, annotated by 13 radiologists. In three iterative training experiments, we aimed to improve and accelerate segmentation of the heart and mediastinum. Each experiment started with manual segmentation of 5-25 CT scans, which served as training data for a nnU-Net. Further iterations incorporated AI pre-segmentation and human correction to improve accuracy, accelerate the annotation process, and reduce human involvement over time. RESULTS: Results showed consistent improvement in AI model quality with each iteration. Resampled datasets improved the Dice similarity coefficients for both the heart (DCS 0.91 [0.88; 0.92]) and the mediastinum (DCS 0.95 [0.94; 0.95]). Our AI models reduced human interaction time by 50 % for heart and 70 % for mediastinum segmentation in the most potent iteration. A model trained on only five datasets achieved satisfactory results (DCS > 0.90). CONCLUSIONS: The iterative training workflow provides an efficient method for training AI-based segmentation models in multi-center studies, improving accuracy over time and simultaneously reducing human intervention. Future work will explore the use of fewer initial datasets and additional pre-processing methods to enhance model quality.


Subject(s)
Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/methods , Artificial Intelligence , Mediastinum/diagnostic imaging , Heart/diagnostic imaging
3.
J Cardiovasc Magn Reson ; 25(1): 22, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36978131

ABSTRACT

BACKGROUND: Different software programs are available for the evaluation of 4D Flow cardiovascular magnetic resonance (CMR). A good agreement of the results between programs is a prerequisite for the acceptance of the method. Therefore, the goal was to compare quantitative results from a cross-over comparison in individuals examined on two scanners of different vendors analyzed with four postprocessing software packages. METHODS: Eight healthy subjects (27 ± 3 years, 3 women) were each examined on two 3T CMR systems (Ingenia, Philips Healthcare; MAGNETOM Skyra, Siemens Healthineers) with a standardized 4D Flow CMR sequence. Six manually placed aortic contours were evaluated with Caas (Pie Medical Imaging, SW-A), cvi42 (Circle Cardiovascular Imaging, SW-B), GTFlow (GyroTools, SW-C), and MevisFlow (Fraunhofer Institute MEVIS, SW-D) to analyze seven clinically used parameters including stroke volume, peak flow, peak velocity, and area as well as typically scientifically used wall shear stress values. Statistical analysis of inter- and intrareader variability, inter-software and inter-scanner comparison included calculation of absolute and relative error (ER), intraclass correlation coefficient (ICC), Bland-Altman analysis, and equivalence testing based on the assumption that inter-software differences needed to be within 80% of the range of intrareader differences. RESULTS: SW-A and SW-C were the only software programs showing agreement for stroke volume (ICC = 0.96; ER = 3 ± 8%), peak flow (ICC: 0.97; ER = -1 ± 7%), and area (ICC = 0.81; ER = 2 ± 22%). Results from SW-A/D and SW-C/D were equivalent only for area and peak flow. Other software pairs did not yield equivalent results for routinely used clinical parameters. Especially peak maximum velocity yielded poor agreement (ICC ≤ 0.4) between all software packages except SW-A/D that showed good agreement (ICC = 0.80). Inter- and intrareader consistency for clinically used parameters was best for SW-A and SW-D (ICC = 0.56-97) and worst for SW-B (ICC = -0.01-0.71). Of note, inter-scanner differences per individual tended to be smaller than inter-software differences. CONCLUSIONS: Of all tested software programs, only SW-A and SW-C can be used equivalently for determination of stroke volume, peak flow, and vessel area. Irrespective of the applied software and scanner, high intra- and interreader variability for all parameters have to be taken into account before introducing 4D Flow CMR in clinical routine. Especially in multicenter clinical trials a single image evaluation software should be applied.


Subject(s)
Magnetic Resonance Imaging , Software , Humans , Female , Reproducibility of Results , Predictive Value of Tests , Aorta
4.
Rofo ; 195(2): 115-134, 2023 02.
Article in English, German | MEDLINE | ID: mdl-36634682

ABSTRACT

This position paper is a joint statement of the German Radiological Society (DRG) and the Professional Association of German Radiologists (BDR), which reflects the current state of knowledge about coronary computed tomography. It is based on preclinical and clinical studies that have investigated the clinical relevance as well as the technical requirements and fundamentals of cardiac computed tomography. CITATION FORMAT: · Langenbach MC, Sandstede J, Sieren M et al. DRG and BDR Position Paper on Coronary CT: Clinical Evidence and Quality of Patient Care in Chronic Coronary Syndrome. Fortschr Röntgenstr 2023; 195: 115 - 133.


Subject(s)
Radiology , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Heart , Radiologists , Patient Care
5.
Cardiovasc Intervent Radiol ; 46(3): 392-399, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36513764

ABSTRACT

PURPOSE: Magnetic particle imaging (MPI) is a tomographic imaging modality with the potential for cardiovascular applications. In this context, the extent to which stents are heated should be estimated from safety perspective. Furthermore, the influence of the measurement parameters and stent distance to the isocenter of the MPI scanner on stent heating were evaluated. MATERIALS AND METHODS: Nine different endovascular stents and stent grafts were tested in polyvinyl-chloride tubes. The stents had diameters from 10 to 31 mm, lengths between 25 and 100 mm and were made from stainless steel, nitinol or cobalt-chromium. The temperature differences were recorded with fiber-optic thermometers. All measurements were performed in a preclinical commercial MPI scanner. The measurement parameters were varied (drive field strengths: 3, 6, 9, 12 mT and selection field gradients: 0, 1.25 and 2.5 T/m). Furthermore, measurements with different distances to the scanner's isocenter were performed (100 to 0 mm). RESULTS: All stents showed heating (maximum 53.1 K, minimum 4.6 K). The stent diameter directly correlated with the temperature increase. The drive field strength influenced the heating of the stents, whereas the selection field gradient had no detectable impact. The heating of the stents decreased with increasing distance from the scanner's isocenter and thus correlated with the loss of the scanner's magnetic field. CONCLUSION: Stents can cause potentially harmful heating in MPI. In addition to the stent diameter and design, the drive field strength and the distance to the MPI scanner's isocenter must be kept in mind as influencing parameters.


Subject(s)
Endovascular Procedures , Heating , Stents , Tomography , Humans , Magnetic Phenomena , Endovascular Aneurysm Repair
6.
Radiologie (Heidelb) ; 62(11): 902-911, 2022 Nov.
Article in German | MEDLINE | ID: mdl-36222875

ABSTRACT

In the guideline updates of the European Society of Cardiology (ESC), noninvasive radiological cross-sectional imaging is taking an increasingly prominent role, while at the same time invasive diagnostic approaches are becoming less important. Especially for the diagnosis and treatment of chronic and acute coronary syndromes, there are fundamental changes in clinical routine. In addition, cross-sectional imaging also offers an alternative to diagnostic algorithms for other cardiac pathologies, especially echocardiography, which is increasingly used in the differential diagnosis of cardiac diseases. The radiologist should be aware of the recommendations of the current guidelines and encourage their establishment in clinical practice. This paper summarizes the indications of cross-sectional cardiac imaging with focus on new recommendations in the ESC guidelines and addresses specific strengths and weaknesses of each modality.


Subject(s)
Coronary Artery Disease , Heart , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Cardiology/methods , Coronary Artery Disease/diagnostic imaging , Heart/diagnostic imaging , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods , Coronary Angiography
7.
Nanomaterials (Basel) ; 12(10)2022 May 21.
Article in English | MEDLINE | ID: mdl-35630979

ABSTRACT

The purpose of this work was to develop instrument markers that are visible in both magnetic particle imaging (MPI) and magnetic resonance imaging (MRI). The instrument markers were based on two different magnetic nanoparticle types (synthesized in-house KLB and commercial Bayoxide E8706). Coatings containing one of both particle types were fabricated and measured with a magnetic particle spectrometer (MPS) to estimate their MPI performance. Coatings based on both particle types were then applied on a segment of a nonmetallic guidewire. Imaging experiments were conducted using a commercial, preclinical MPI scanner and a preclinical 1 tesla MRI system. MPI image reconstruction was performed based on system matrices measured with dried KLB and Bayoxide E8706 coatings. The bimodal markers were clearly visible in both methods. They caused circular signal voids in MRI and areas of high signal intensity in MPI. Both the signal voids as well as the areas of high signal intensity were larger than the real marker size. Images that were reconstructed with a Bayoxide E8706 system matrix did not show sufficient MPI signal. Instrument markers with bimodal visibility are essential for the perspective of monitoring cardiovascular interventions with MPI/MRI hybrid systems.

8.
Rofo ; 194(3): 272-280, 2022 03.
Article in English, German | MEDLINE | ID: mdl-34794186

ABSTRACT

PURPOSE: Comparison of puncture deviation and puncture duration between computed tomography (CT)- and C-arm CT (CACT)-guided puncture performed by residents in training (RiT). METHODS: In a cohort of 25 RiTs enrolled in a research training program either CT- or CACT-guided puncture was performed on a phantom. Prior to the experiments, the RiT's level of training, experience playing a musical instrument, video games, and ball sports, and self-assessed manual skills and spatial skills were recorded. Each RiT performed two punctures. The first puncture was performed with a transaxial or single angulated needle path and the second with a single or double angulated needle path. Puncture deviation and puncture duration were compared between the procedures and were correlated with the self-assessments. RESULTS: RiTs in both the CT guidance and CACT guidance groups did not differ with respect to radiologic experience (p = 1), angiographic experience (p = 0.415), and number of ultrasound-guided puncture procedures (p = 0.483), CT-guided puncture procedures (p = 0.934), and CACT-guided puncture procedures (p = 0.466). The puncture duration was significantly longer with CT guidance (without navigation tool) than with CACT guidance with navigation software (p < 0.001). There was no significant difference in the puncture duration between the first and second puncture using CT guidance (p = 0.719). However, in the case of CACT, the second puncture was significantly faster (p = 0.006). Puncture deviations were not different between CT-guided and CACT-guided puncture (p = 0.337) and between the first and second puncture of CT-guided and CACT-guided puncture (CT: p = 0.130; CACT: p = 0.391). The self-assessment of manual skills did not correlate with puncture deviation (p = 0.059) and puncture duration (p = 0.158). The self-assessed spatial skills correlated positively with puncture deviation (p = 0.011) but not with puncture duration (p = 0.541). CONCLUSION: The RiTs achieved a puncture deviation that was clinically adequate with respect to their level of training and did not differ between CT-guided and CACT-guided puncture. The puncture duration was shorter when using CACT. CACT guidance with navigation software support has a potentially steeper learning curve. Spatial skills might accelerate the learning of image-guided puncture. KEY POINTS: · The CT-guided and CACT-guided puncture experience of the RiTs selected as part of the program "Researchers for the Future" of the German Roentgen Society was adequate with respect to the level of training.. · Despite the lower collective experience of the RiTs with CACT-guided puncture with navigation software assistance, the learning curve regarding CACT-guided puncture may be faster compared to the CT-guided puncture technique.. · If the needle path is complex, CACT guidance with navigation software assistance might have an advantage over CT guidance.. CITATION FORMAT: · Meine TC, Hinrichs JB, Werncke T et al. Phantom study for comparison between computed tomography- and C-Arm computed tomography-guided puncture applied by residents in radiology. Fortschr Röntgenstr 2022; 194: 272 - 280.


Subject(s)
Radiology , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Punctures/methods , Software , Tomography, X-Ray Computed/methods
9.
Cardiovasc Intervent Radiol ; 44(7): 1109-1115, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33723668

ABSTRACT

PURPOSE: To evaluate heating of a redilatable stent for the treatment of aortic coarctation in neonates and small children in the new imaging modality magnetic particle imaging and established magnetic resonance imaging. MATERIALS AND METHODS: The cobalt-chromium stent (BabyStent, OSYPKA AG, Rheinfelden, Germany) has a stent design which allows for redilatation and adjustment of the diameter from 6 to 16 mm for a use in aortic coarctation. The stent loses its radial integrity while opening at predetermined breaking points at a diameter of 14 mm or 16 mm, respectively. We measured the temperature increase in the stent at different diameters during 7-min magnetic particle imaging and magnetic resonance imaging scans with fiber optic thermometers under static conditions surrounded by air. In magnetic particle imaging, stents with diameters from 6 to 16 mm were tested while in magnetic resonance imaging only stents with diameters of 6 mm and 14 mm were investigated exemplarily. RESULT: In magnetic particle imaging, the measured temperature differences increased up to 4.7 K with growing diameters, whereas the opened stents with discontinuous struts at 14 and 16 mm showed only minimal heating of max. 0.5 K. In contrast to magnetic particle imaging, our measurements showed no heating of the stents during magnetic resonance imaging under identical conditions. CONCLUSION: The BabyStent did show only slight heating in magnetic particle imaging and no detectable temperature increase in magnetic resonance imaging.


Subject(s)
Aortic Coarctation/surgery , Blood Vessel Prosthesis Implantation/methods , Heating/methods , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Stents , Aortic Coarctation/diagnosis , Humans , Treatment Outcome
10.
J Thorac Cardiovasc Surg ; 159(3): 798-810.e1, 2020 03.
Article in English | MEDLINE | ID: mdl-31078313

ABSTRACT

OBJECTIVE: The aim of this study was to compare aortic flow patterns in patients after David valve-sparing aortic root replacement with physiologically shaped sinus prostheses or conventional tube grafts in healthy volunteers. METHODS: Twelve patients with sinus prostheses (55 ± 15 years), 6 patients with tube grafts (58 ± 12 years), 12 age-matched, healthy volunteers (55 ± 6 years), and 6 young, healthy volunteers (25 ± 3 years) were examined with time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI). Primary and secondary helical, as well as vortical flow patterns, were evaluated. Aortic arch anatomy as a flow influencing factor was determined. RESULTS: Compared with volunteers, both sinus prostheses and tube grafts developed more than 4 times as many secondary flow patterns in the ascending aorta (sinus prostheses n = 1.6 ± 0.8; tube grafts n = 1.3 ± 0.6; age-matched, healthy volunteers n = 0.3 ± 0.5; young, healthy volunteers n = 0; P ≤ .012) associated with a kinking of the prosthesis itself or at its distal anastomosis. As opposed to round aortic arches in volunteers (n = 16/18), cubic or gothic-shaped arches predominated in patients (n = 16/18, P < .001). In all but 3 volunteers, 2 counter-rotating helices were confirmed in the ascending aorta and were defined as a primary flow pattern. This primary flow pattern did not develop in patients who underwent valve-sparing aortic root replacement. CONCLUSIONS: In patients after valve-sparing aortic root replacement, there was an increased number of secondary flow patterns in the ascending aorta. This seems to be related to surgically altered aortic geometry with kinking. Because flow alterations are known to affect wall shear stress, there seems to be an increased risk for vessel wall remodeling. Compared with previous 4D Flow MRI studies, primary flow patterns in the ascending aorta in healthy subjects were confirmed to be more complex. This underlines the importance of thorough examination of 4D Flow MRI data.


Subject(s)
Aorta/surgery , Aortic Aneurysm/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Hemodynamics , Imaging, Three-Dimensional , Magnetic Resonance Angiography , Perfusion Imaging/methods , Adult , Aged , Aorta/diagnostic imaging , Aorta/physiopathology , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Blood Flow Velocity , Blood Vessel Prosthesis Implantation/adverse effects , Case-Control Studies , Female , Humans , Male , Middle Aged , Models, Cardiovascular , Patient-Specific Modeling , Pilot Projects , Predictive Value of Tests , Prosthesis Design , Prosthesis Failure , Regional Blood Flow , Time Factors , Treatment Outcome
11.
Cardiovasc Intervent Radiol ; 43(2): 331-338, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31578634

ABSTRACT

PURPOSE: To illustrate the potential of magnetic particle imaging (MPI) for stent lumen imaging in comparison with clinical computed tomography (CT) and magnetic resonance imaging (MRI). MATERIALS AND METHODS: Imaging of eight tracer-filled, stented vessel phantoms and a tracer-filled, non-stented reference phantom for each diameter was performed on a preclinical MPI scanner: eight commercially available coronary stents of different dimensions (diameter: 3-4 mm; length: 11-38 mm) and materials (stainless steel, platinum-chromium) were implanted into silicone vessel phantoms. For comparison, all vessel phantoms were also visualized by MRI and CT. Two radiologists assessed the images regarding stent-induced artifacts using a 5-point grading scale. RESULTS: The visualization of all stented vessel phantoms was achieved without stent-induced artifacts with MPI. In contrast, MRI and CT images revealed multiform stent-induced artifacts. CONCLUSION: Given its clinical introduction, MPI has the potential to overcome the disadvantages of MRI and CT concerning the visualization of the stent lumen.


Subject(s)
Artifacts , Image Processing, Computer-Assisted/methods , Magnetite Nanoparticles , Phantoms, Imaging , Stents , Tomography/methods , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL