Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Polymers (Basel) ; 16(2)2024 Jan 22.
Article En | MEDLINE | ID: mdl-38276708

The conventional production technique employed for low-permeability tight reservoirs exhibits limited productivity. To solve the problem, an acetate-type supercritical carbon dioxide (scCO2) thickener, PVE, which contains a large number of microporous structures, was prepared using the atom transfer radical polymerization (ATRP) method. The product exhibited an ability to decrease the minimum miscibility pressure of scCO2 during a solubility test and demonstrated a favorable extraction efficiency in a low-permeability tight core displacement test. At 15 MPa and 70 °C, PVE-scCO2 at a concentration of 0.2% exhibits effective oil recovery rates of 5.61% for the 0.25 mD core and 2.65% for the 5 mD core. The result demonstrates that the incorporation of the thickener PVE can effectively mitigate gas channeling, further improve oil displacement efficiency, and inflict minimal damage to crude oil. The mechanism of thickening was analyzed through molecular simulation. The calculated trend of thickening exhibited excellent agreement with the experimental measurement rule. The simulation results demonstrate that the contact area between the polymer and CO2 increases in direct proportion to both the number of thickener molecules and the viscosity of the system. The study presents an effective strategy for mitigating gas channeling during scCO2 flooding and has a wide application prospect.

2.
Polymers (Basel) ; 15(7)2023 Apr 01.
Article En | MEDLINE | ID: mdl-37050379

Preparation of tough and high-strength hydrogels for water plugging in oil fields with an easy-scalable method is still considered to be a challenge. In this study, dialdehyde cellulose nanofibril (DA-CNF) prepared by sodium periodate oxidation, polyamine, 2-acrylamido-2-methylpropane sulfonic acid (AMPS) with sulfonate groups and Acrylamide (AM) as raw materials, CNF reinforced nanocomposite hydrogels were prepared in one step by in-situ polymerization. The tensile strength, and texture stability of the obtained nanocomposite hydrogel were determined. The results showed that the tensile strength and toughness of the obtained nanocomposite hydrogel increased four times compared with control sample due to physical and chemical double crosslinking synergies. Moreover, the texture intensity of DA-CNFs reinforced hydrogel still maintains high stability and strength performance under high salinity conditions. Therefore, DA-CNF reinforced hydrogel has potential application value in both normal and high-salinity environments in oil recovery.

3.
Polymers (Basel) ; 15(6)2023 Mar 14.
Article En | MEDLINE | ID: mdl-36987230

In drilling and completion projects, sludge is formed as a byproduct when barite and oil are mixed, and later sticks to the casing. This phenomenon has caused a delay in drilling progress, and increased exploration and development costs. Since nano-emulsions have low interfacial surface tension, wetting, and reversal capabilities, this study used nano-emulsions with a particle size of about 14 nm to prepare a cleaning fluid system. This system enhances stability through the network structure in the fiber-reinforced system, and prepares a set of nano-cleaning fluids with adjustable density for ultra-deep wells. The effective viscosity of the nano-cleaning fluid reaches 11 mPa·s, and the system is stable for up to 8 h. In addition, this research independently developed an indoor evaluation instrument. Based on on-site parameters, the performance of the nano-cleaning fluid was evaluated from multiple angles by heating to 150 °C and pressurizing to 3.0 Mpa to simulate downhole temperature and pressure. The evaluation results show that the viscosity and shear value of the nano-cleaning fluid system is greatly affected by the fiber content, and the cleaning efficiency is greatly affected by the concentration of the nano-emulsion. Curve fitting shows that the average processing efficiency could reach 60-85% within 25 min and the cleaning efficiency has a linear relationship with time. The cleaning efficiency has a linear relationship with time, where R2 = 0.98335. The nano-cleaning fluid enables the deconstruction and carrying of the sludge attached to the well wall, which accomplishes the purpose of downhole cleaning.

...