ABSTRACT
Mitral valve repair or replacement poses a potential risk of injury to the left circumflex coronary artery (LCx). Such injuries can arise from either direct LCx injury caused by encircling or transfixing stitches, or indirect occlusion resulting from the distortion of adjacent tissues. We provide and illustrate a representative image depicting LCx distortion. Additionally, we offer guidance to aid angiographers in comprehending the angiographic appearance and the underlying mechanism of occlusion.
ABSTRACT
BACKGROUND: Although covered stents (CS) represent a potentially life-saving intervention for coronary perforation (CAP), their application has expanded to other contexts, including coronary aneurysms (CAA). However, data regarding mid- and long-term outcomes of CS in these settings scenarios remains limited. AIMS: This meta-analysis aims to evaluate major adverse cardiac events (MACE) from discharge through long-term follow-up in patients undergoing percutaneous coronary intervention with the new generation polyurethane-covered cobalt-chromium PK Papyrus CS. METHODS: We conducted a meta-analysis of data from three observational trials that included long-term follow-up of patients who underwent PK Papyrus CS implantation: Papyrus-Spain, SOS PK Papyrus, and PAST-PERF registry. RESULTS: 332 patients underwent PK Papyrus CS implantation, 236 (71.1%) for CAP, 70 (21.1%) for CAA and 26 (7.8%) for other indications. After a mean follow-up of 16.2 months, the MACE was 14.3%, with Target Lesion Revascularization (TLR) being the most frequent (8.5%), followed by stent thrombosis (ST), 3.3% and cardiac death (CD), 2.6%. Comparing CAP and CAA subgroups, the MACE rate in CAA was significantly higher than CAP (21.4% vs 9.7%, p < 0.01), primary driven by ST (CAA: 8.6% vs CAP: 1.3%; p = 0.0015). CONCLUSIONS: The clinical outcomes following PK Papyrus CS implantation are deemed acceptable, considering the challenging scenarios and the existing alternative treatments. However, MACE rates in patients with CAA who received Papyrus PK CS were significantly higher than in those with CAP, underscoring the importance of meticulous patient selection and optimization of CS in these complex patients and coronary anatomies.
ABSTRACT
Catheter-induced stent dislodgement may occur when attempting to withdraw the stent into the guide-catheter particularly in cases of guiding-catheter co-axiality issues. We present the management of a catheter-induced stent dislodgement with simultaneous loss of wire position.