Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Microorganisms ; 12(6)2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38930608

ABSTRACT

Periodontal disease (PerioD) is a chronic inflammatory disease of dysbiotic etiology. Animal models and few human data showed a relationship between oral bacteria and gut dysbiosis. However, the effect of periodontal inflammation and subgingival dysbiosis on the gut is unknown. We hypothesized that periodontal inflammation and its associated subgingival dysbiosis contribute to gut dysbiosis even in subjects free of known gut disorders. We evaluated and compared elderly subjects with Low and High periodontal inflammation (assessed by Periodontal Inflamed Surface Area (PISA)) for stool and subgingival derived bacteria (assayed by 16S rRNA sequencing). The associations between PISA/subgingival dysbiosis and gut dysbiosis and bacteria known to produce short-chain fatty acid (SCFA) were assessed. LEfSe analysis showed that, in Low PISA, species belonging to Lactobacillus, Roseburia, and Ruminococcus taxa and Lactobacillus zeae were enriched, while species belonging to Coprococcus, Clostridiales, and Atopobium were enriched in High PISA. Regression analyses showed that PISA associated with indicators of dysbiosis in the gut mainly reduced abundance of SCFA producing bacteria (Radj = -0.38, p = 0.03). Subgingival bacterial dysbiosis also associated with reduced levels of gut SCFA producing bacteria (Radj = -0.58, p = 0.002). These results suggest that periodontal inflammation and subgingival microbiota contribute to gut bacterial changes.

2.
Viruses ; 16(6)2024 Jun 09.
Article in English | MEDLINE | ID: mdl-38932227

ABSTRACT

The HIV envelope glycoprotein (Env) is a trimeric protein that facilitates viral binding and fusion with target cells. As the sole viral protein on the HIV surface, Env is important both for immune responses to HIV and in vaccine designs. Targeting Env in clinical applications is challenging due to its heavy glycosylation, high genetic variability, conformational camouflage, and its low abundance on virions. Thus, there is a critical need to better understand this protein. Flow virometry (FV) is a useful methodology for phenotyping the virion surface in a high-throughput, single virion manner. To demonstrate the utility of FV to characterize Env, we stained HIV virions with a panel of 85 monoclonal antibodies targeting different regions of Env. A broad range of antibodies yielded robust staining of Env, with V3 antibodies showing the highest quantitative staining. A subset of antibodies tested in parallel on viruses produced in CD4+ T cell lines, HEK293T cells, and primary cells showed that the cellular model of virus production can impact Env detection. Finally, in addition to being able to highlight Env heterogeneity on virions, we show FV can sensitively detect differences in Env conformation when soluble CD4 is added to virions before staining.


Subject(s)
HIV-1 , Virion , env Gene Products, Human Immunodeficiency Virus , Humans , env Gene Products, Human Immunodeficiency Virus/chemistry , env Gene Products, Human Immunodeficiency Virus/metabolism , env Gene Products, Human Immunodeficiency Virus/genetics , env Gene Products, Human Immunodeficiency Virus/immunology , HIV-1/genetics , HIV-1/physiology , HIV-1/immunology , Virion/metabolism , HEK293 Cells , HIV Antibodies/immunology , Antibodies, Monoclonal/immunology , CD4-Positive T-Lymphocytes/virology , CD4-Positive T-Lymphocytes/immunology , HIV Infections/virology
3.
J Virol ; 98(5): e0036324, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38661384

ABSTRACT

HIV-1 has a broad range of nuanced interactions with the immune system, and the incorporation of cellular proteins by nascent virions continues to redefine our understanding of the virus-host relationship. Proteins located at the sites of viral egress can be selectively incorporated into the HIV-1 envelope, imparting new functions and phenotypes onto virions, and impacting viral spread and disease. Using virion capture assays and western blot, we show that HIV-1 can incorporate the myeloid antigen CD14 into its viral envelope. Virion-incorporated CD14 remained biologically active and able to bind its natural ligand, bacterial lipopolysaccharide (LPS), as demonstrated by flow virometry and immunoprecipitation assays. Using a Toll-like receptor 4 (TLR4) reporter cell line, we also demonstrated that virions with bound LPS can trigger TLR4 signaling to activate transcription factors that regulate inflammatory gene expression. Complementary assays with THP-1 monocytes demonstrated enhanced secretion of inflammatory cytokines like tumor necrosis factor alpha (TNF-α) and the C-C chemokine ligand 5 (CCL5), when exposed to LPS-loaded virus. These data highlight a new type of interplay between HIV-1 and the myeloid cell compartment, a previously well-established cellular contributor to HIV-1 pathogenesis and inflammation. Persistent gut inflammation is a hallmark of chronic HIV-1 infection, and contributing to this effect is the translocation of microbes across the gut epithelium. Our data herein provide proof of principle that virion-incorporated CD14 could be a novel mechanism through which HIV-1 can drive chronic inflammation, facilitated by HIV-1 particles binding bacterial LPS and initiating inflammatory signaling in TLR4-expressing cells.IMPORTANCEHIV-1 establishes a lifelong infection accompanied by numerous immunological changes. Inflammation of the gut epithelia, exacerbated by the loss of mucosal T cells and cytokine dysregulation, persists during HIV-1 infection. Feeding back into this loop of inflammation is the translocation of intestinal microbes across the gut epithelia, resulting in the systemic dissemination of bacterial antigens, like lipopolysaccharide (LPS). Our group previously demonstrated that the LPS receptor, CD14, can be readily incorporated by HIV-1 particles, supporting previous clinical observations of viruses derived from patient plasma. We now show that CD14 can be incorporated by several primary HIV-1 isolates and that this virion-incorporated CD14 can remain functional, enabling HIV-1 to bind to LPS. This subsequently allowed CD14+ virions to transfer LPS to monocytic cells, eliciting pro-inflammatory signaling and cytokine secretion. We posit here that virion-incorporated CD14 is a potential contributor to the dysregulated immune responses present in the setting of HIV-1 infection.


Subject(s)
HIV Infections , HIV-1 , Lipopolysaccharide Receptors , Lipopolysaccharides , Virion , Humans , Chemokine CCL5/metabolism , HIV Infections/virology , HIV Infections/immunology , HIV Infections/metabolism , HIV-1/immunology , HIV-1/physiology , Lipopolysaccharide Receptors/metabolism , Lipopolysaccharides/metabolism , Monocytes/metabolism , Monocytes/immunology , Monocytes/virology , Signal Transduction , THP-1 Cells , Toll-Like Receptor 4/metabolism , Tumor Necrosis Factor-alpha/metabolism , Virion/metabolism
4.
Cytometry A ; 105(2): 88-111, 2024 02.
Article in English | MEDLINE | ID: mdl-37941128

ABSTRACT

The purpose of this document is to provide guidance for establishing and maintaining growth and development of flow cytometry shared resource laboratories. While the best practices offered in this manuscript are not intended to be universal or exhaustive, they do outline key goals that should be prioritized to achieve operational excellence and meet the needs of the scientific community. Additionally, this document provides information on available technologies and software relevant to shared resource laboratories. This manuscript builds on the work of Barsky et al. 2016 published in Cytometry Part A and incorporates recent advancements in cytometric technology. A flow cytometer is a specialized piece of technology that require special care and consideration in its housing and operations. As with any scientific equipment, a thorough evaluation of the location, space requirements, auxiliary resources, and support is crucial for successful operation. This comprehensive resource has been written by past and present members of the International Society for Advancement of Cytometry (ISAC) Shared Resource Laboratory (SRL) Emerging Leaders Program https://isac-net.org/general/custom.asp?page=SRL-Emerging-Leaders with extensive expertise in managing flow cytometry SRLs from around the world in different settings including academia and industry. It is intended to assist in establishing a new flow cytometry SRL, re-purposing an existing space into such a facility, or adding a flow cytometer to an individual lab in academia or industry. This resource reviews the available cytometry technologies, the operational requirements, and best practices in SRL staffing and management.


Subject(s)
Laboratories , Software , Flow Cytometry
5.
Cell Rep Methods ; 3(12): 100664, 2023 Dec 18.
Article in English | MEDLINE | ID: mdl-38113854

ABSTRACT

Flow cytometry (FCM) is a common method for characterizing extracellular particles (EPs), including viruses and extracellular vesicles (EVs). Frameworks such as MIFlowCyt-EV exist to provide reporting guidelines for metadata, controls, and data reporting. However, tools to optimize FCM for EP analysis in a systematic and quantitative way are lacking. Here, we demonstrate a cohesive set of methods and software tools that optimize FCM settings and facilitate cross-platform comparisons for EP studies. We introduce an automated small-particle optimization (SPOT) pipeline to optimize FCM fluorescence and light scatter detector settings for EP analysis and leverage quantitative FCM (qFCM) as a tool to further enable FCM optimization of fluorophore panel selection, laser power, pulse statistics, and window extensions. Finally, we demonstrate the value of qFCM to facilitate standardized cross-platform comparisons, irrespective of instrument configuration, settings, and sensitivity, in a cross-platform standardization study utilizing a commercially available EV reference material.


Subject(s)
Extracellular Vesicles , Flow Cytometry , Fluorescent Dyes , Software , Light
6.
Sci Rep ; 13(1): 23025, 2023 12 27.
Article in English | MEDLINE | ID: mdl-38155248

ABSTRACT

While numerous cellular proteins in the HIV envelope are known to alter virus infection, methodology to rapidly phenotype the virion surface in a high throughput, single virion manner is lacking. Thus, many human proteins may exist on the virion surface that remain undescribed. Herein, we developed a novel flow virometry screening assay to discover new proteins on the surface of HIV particles. By screening a CD4+ T cell line and its progeny virions, along with four HIV isolates produced in primary cells, we discovered 59 new candidate proteins in the HIV envelope that were consistently detected across diverse HIV isolates. Among these discoveries, CD38, CD97, and CD278 were consistently present at high levels on virions when using orthogonal techniques to corroborate flow virometry results. This study yields new discoveries about virus biology and demonstrates the utility and feasibility of a novel flow virometry assay to phenotype individual virions.


Subject(s)
HIV Infections , Viruses , Humans , Virion/genetics , Cell Line , HIV Infections/metabolism
7.
Nano Lett ; 23(20): 9195-9202, 2023 10 25.
Article in English | MEDLINE | ID: mdl-37788377

ABSTRACT

The analysis of small particles, including extracellular vesicles and viruses, is contingent on their ability to scatter sufficient light to be detected. These detection methods include flow cytometry, nanoparticle tracking analysis, and single particle reflective image sensing. To standardize measurements and enable orthogonal comparisons between platforms, a quantifiable limit of detection is required. The main parameters that dictate the amount of light scattered by particles include size, morphology, and refractive index. To date, there has been a lack of accessible techniques for measuring the refractive index of nanoparticles at a single-particle level. Here, we demonstrate two methods of deriving a small particle refractive index using orthogonal measurements with commercially available platforms. These methods can be applied at either a single-particle or population level, enabling the integration of diameter and scattering cross section values to derive the refractive index using Mie theory.


Subject(s)
Extracellular Vesicles , Nanoparticles , Humans , Refractometry , Flow Cytometry/methods
8.
PLoS One ; 18(2): e0280333, 2023.
Article in English | MEDLINE | ID: mdl-36791096

ABSTRACT

BACKGROUND: Periodontal disease (PerioD) is a chronic, complex inflammatory condition resulting from the interaction between subgingival dysbiotic bacteria and the host immune response leading to local inflammation. Since periodontal inflammation is characterized by multiple cytokines effects we investigated whether Periodontal Inflamed Surface Area (PISA), a continuous measure of clinical periodontal inflammation is a predictor of composite indexes of salivary cytokines. METHODS AND FINDINGS: In a cross-sectional study of 67 healthy, well-educated individuals, we evaluated PISA and several cytokines expressed in whole stimulated saliva. Two salivary cytokine indexes were constructed using weighted and unweighted approaches based on a Principal Component Analysis [named Cytokine Component Index (CCI)] or averaging the (standardized) level of all cytokines [named Composite Inflammatory Index (CII)]. In regression analysis we found that PISA scores were significantly associated with both salivary cytokine constructs, (CCI: part R = 0.51, p<0.001; CII: part R = 0.40, p = 0.001) independent of age, gender and BMI showing that single scores summarizing salivary cytokines correlated with severity of clinical periodontal inflammation. CONCLUSIONS: Clinical periodontal inflammation may be reflected by a single score encompassing several salivary cytokines. These results are consistent with the complexity of interactions characterizing periodontal disease. In addition, Type I error is likely to be avoided.


Subject(s)
Periodontal Diseases , Periodontitis , Humans , Cytokines , Cross-Sectional Studies , Inflammation , Saliva
9.
J Extracell Vesicles ; 12(2): e12299, 2023 02.
Article in English | MEDLINE | ID: mdl-36759917

ABSTRACT

Flow cytometry (FCM) offers a multiparametric technology capable of characterizing single extracellular vesicles (EVs). However, most flow cytometers are designed to detect cells, which are larger than EVs. Whereas cells exceed the background noise, signals originating from EVs partly overlap with the background noise, thereby making EVs more difficult to detect than cells. This technical mismatch together with complexity of EV-containing fluids causes limitations and challenges with conducting, interpreting and reproducing EV FCM experiments. To address and overcome these challenges, researchers from the International Society for Extracellular Vesicles (ISEV), International Society for Advancement of Cytometry (ISAC), and the International Society on Thrombosis and Haemostasis (ISTH) joined forces and initiated the EV FCM working group. To improve the interpretation, reporting, and reproducibility of future EV FCM data, the EV FCM working group published an ISEV position manuscript outlining a framework of minimum information that should be reported about an FCM experiment on single EVs (MIFlowCyt-EV). However, the framework contains limited background information. Therefore, the goal of this compendium is to provide the background information necessary to design and conduct reproducible EV FCM experiments. This compendium contains background information on EVs, the interaction between light and EVs, FCM hardware, experimental design and preanalytical procedures, sample preparation, assay controls, instrument data acquisition and calibration, EV characterization, and data reporting. Although this compendium focuses on EVs, many concepts and explanations could also be applied to FCM detection of other particles within the EV size range, such as bacteria, lipoprotein particles, milk fat globules, and viruses.


Subject(s)
Extracellular Vesicles , Flow Cytometry/methods , Reproducibility of Results
10.
Retrovirology ; 19(1): 9, 2022 05 21.
Article in English | MEDLINE | ID: mdl-35597982

ABSTRACT

BACKGROUND: P-selectin glycoprotein ligand-1 (PSGL-1/CD162) has been studied extensively for its role in mediating leukocyte rolling through interactions with its cognate receptor, P-selectin. Recently, PSGL-1 was identified as a novel HIV-1 host restriction factor, particularly when expressed at high levels in the HIV envelope. Importantly, while the potent antiviral activity of PSGL-1 has been clearly demonstrated in various complementary model systems, the breadth of PSGL-1 incorporation across genetically diverse viral isolates and clinical isolates has yet to be described. Additionally, the biological activity of virion-incorporated PSGL-1 has also yet to be shown. RESULTS: Herein we assessed the levels of PSGL-1 on viruses produced through transfection with various amounts of PSGL-1 plasmid DNA (0-250 ng), compared to levels of PSGL-1 on viruses produced through infection of T cell lines and primary PBMC. We found that very low levels of PSGL-1 plasmid DNA (< 2.5 ng/well) were necessary to generate virus models that could closely mirror the phenotype of viruses produced via infection of T cells and PBMC. Unique to this study, we show that PSGL-1 is incorporated in a broad range of HIV-1 and SIV isolates and that virions with incorporated PSGL-1 are detectable in plasma from viremic HIV-1-infected individuals, corroborating the relevance of PSGL-1 in natural infection. Additionally, we show that PSGL-1 on viruses can bind its cognate selectin receptors, P-, E-, and L-selectins. Finally, we show viruses with endogenous levels of PSGL-1 can be captured by P-selectin and transferred to HIV-permissive bystander cells, highlighting a novel role for PSGL-1 in HIV-1 infection. Notably, viruses which contained high levels of PSGL-1 were noninfectious in our hands, in line with previous findings reporting the potent antiviral activity of PSGL-1. CONCLUSIONS: Our results indicate that levels of PSGL-1 incorporation into virions can vary widely among model systems tested, and that careful tailoring of plasmid levels is required to recapitulate physiological systems when using pseudovirus models. Taken together, our data suggest that PSGL-1 may play diverse roles in the physiology of HIV-1 infection, particularly due to the functionally active state of PSGL-1 on virion surfaces and the breadth of PSGL-1 incorporation among a wide range of viral isolates.


Subject(s)
HIV Infections , HIV-1 , P-Selectin , Antiviral Agents/metabolism , DNA/metabolism , HIV-1/genetics , HIV-1/metabolism , Humans , Leukocytes, Mononuclear , Membrane Glycoproteins , P-Selectin/metabolism
11.
PLoS One ; 17(1): e0250752, 2022.
Article in English | MEDLINE | ID: mdl-35045082

ABSTRACT

In stem cell research, DNA-binding dyes offer the ability to purify live stem cells using flow cytometry as they form a low-fluorescence side population due to the activity of ABC transporters. Adult neural stem cells exist within the lateral ventricle and dentate gyrus of the adult brain yet the ability of DNA-binding dyes to identify these adult stem cells as side populations remains untested. The following experiments utilize the efflux of a DNA-binding dye, Vyrbant DyeCycle Violet (DCV), to isolate bona fide side populations in the mouse dentate gyrus and subventricular zone (SVZ), and test their sensitivity to ABC transporter inhibitors. A distinct side population was found in both the adult lateral ventricle and dentate gyrus using DCV fluorescence and forward scatter instead of the conventional dual fluorescence approach. These side populations responded strongly to inhibition with the ABC transporter antagonists, verapamil and fumitremorgin C. The majority of the cells residing in the side populations of dentate gyrus and SVZ were characterized by their expression of CD31. Additionally, at least 90% of all CD31+ cells found in the dentate gyrus and SVZ were negative for the hematopoietic marker CD45, leading to the hypothesis that the CD31+ cells in the side population were endothelial cells. These findings, therefore, suggest that the side population analysis provides an efficient method to purify CD31-expressing endothelial cells, but not adult neural stem cells.


Subject(s)
Endothelial Cells
12.
Cytometry A ; 99(1): 68-80, 2021 01.
Article in English | MEDLINE | ID: mdl-33289290

ABSTRACT

Biosafety has always been an important aspect of daily work in any research institution, particularly for cytometry Shared Resources Laboratories (SRLs). SRLs are common-use spaces that facilitate the sharing of knowledge, expertise, and ideas. This sharing inescapably involves contact and interaction of all those within this working environment on a daily basis. The current pandemic caused by SARS-CoV-2 has prompted the re-evaluation of many policies governing the operations of SRLs. Here we identify and review the unique challenges SRLs face in maintaining biosafety standards, highlighting the potential risks associated with not only cytometry instrumentation and samples, but also the people working with them. We propose possible solutions to safety issues raised by the COVID-19 pandemic and provide tools for facilities to adapt to evolving guidelines and future challenges.


Subject(s)
COVID-19/epidemiology , Containment of Biohazards/trends , Laboratories/trends , COVID-19/prevention & control , COVID-19/transmission , Containment of Biohazards/standards , Flow Cytometry , Humans , Laboratories/standards , Risk Assessment/standards , Risk Assessment/trends
14.
Viruses ; 12(11)2020 11 12.
Article in English | MEDLINE | ID: mdl-33198254

ABSTRACT

The HIV-1 glycoprotein spike (gp120) is typically the first viral antigen that cells encounter before initiating immune responses, and is often the sole target in vaccine designs. Thus, characterizing the presence of cellular antigens on the surfaces of HIV particles may help identify new antiviral targets or impact targeting of gp120. Despite the importance of characterizing proteins on the virion surface, current techniques available for this purpose do not support high-throughput analysis of viruses, and typically only offer a semi-quantitative assessment of virus-associated proteins. Traditional bulk techniques often assess averages of viral preparations, which may mask subtle but important differences in viral subsets. On the other hand, microscopy techniques, which provide detail on individual virions, are difficult to use in a high-throughput manner and have low levels of sensitivity for antigen detection. Flow cytometry is a technique that traditionally has been used for rapid, high-sensitivity characterization of single cells, with limited use in detecting viruses, since the small size of viral particles hinders their detection. Herein, we report the detection and surface antigen characterization of HIV-1 pseudovirus particles by light scattering and fluorescence with flow cytometry, termed flow virometry for its specific application to viruses. We quantified three cellular proteins (integrin α4ß7, CD14, and CD162/PSGL-1) in the viral envelope by directly staining virion-containing cell supernatants without the requirement of additional processing steps to distinguish virus particles or specific virus purification techniques. We also show that two antigens can be simultaneously detected on the surface of individual HIV virions, probing for the tetraspanin marker, CD81, in addition to α4ß7, CD14, and CD162/PSGL-1. This study demonstrates new advances in calibrated flow virometry as a tool to provide sensitive, high-throughput characterization of the viral envelope in a more efficient, quantitative manner than previously reported techniques.


Subject(s)
Flow Cytometry , Genetic Engineering , HIV-1/metabolism , Host-Pathogen Interactions , Viral Load , Virion , Biomarkers , Flow Cytometry/methods , HIV-1/genetics , Humans , Reproducibility of Results , Viral Load/methods , Virion/genetics , Virion/metabolism
15.
J Extracell Vesicles ; 9(1): 1816641, 2020 Sep 24.
Article in English | MEDLINE | ID: mdl-33062218

ABSTRACT

Accurate characterization of extracellular vesicles (EVs) is critical to explore their diagnostic and therapeutic applications. As the EV research field has developed, so too have the techniques used to characterize them. The development of reference materials are required for the standardization of these techniques. This work, initiated from the ISEV 2017 Biomarker Workshop in Birmingham, UK, and with further discussion during the ISEV 2019 Standardization Workshop in Ghent, Belgium, sets out to elucidate which reference materials are required and which are currently available to standardize commonly used analysis platforms for characterizing EV refractive index, epitope abundance, size and concentration. Due to their predominant use among EV researchers, a particular focus is placed on the optical methods nanoparticle tracking analysis and flow cytometry.

16.
Cytometry A ; 97(6): 592-601, 2020 06.
Article in English | MEDLINE | ID: mdl-32476280

ABSTRACT

Flow cytometers have been utilized for the analysis of submicron-sized particles since the late 1970s. Initially, virus analyses preceded extracellular vesicle (EV), which began in the 1990s. Despite decades of documented use, the lack of standardization in data reporting has resulted in a growing body of literature that cannot be easily interpreted, validated, or reproduced. This has made it difficult for objective assessments of both assays and instruments, in-turn leading to significant hindrances in scientific progress, specifically in the study of EVs, where the phenotypic analysis of these submicron-sized vesicles is becoming common-place in every biomedical field. Methods for fluorescence and light scatter standardization are well established and the reagents to perform these analyses are commercially available. However, fluorescence and light scatter calibration are not widely adopted by the small particle community as methods to standardize flow cytometry (FCM) data. In this proof-of-concept study carried out as a resource for use at the CYTO2019 workshop, we demonstrate for the first-time simultaneous fluorescence and light scatter calibration of small particle data to show the ease and feasibility of this method for standardized FCM data reporting. This data was acquired using standard configuration commercial flow cytometers, with commercially available materials, published methods, and freely available software tools. We show that application of light scatter, fluorescence, and concentration calibration can result in highly concordant data between FCM platforms independent of instrument collection angle, gain/voltage settings, and flow rate; thus, providing a means of cross comparison in standard units. © 2020 International Society for Advancement of Cytometry.


Subject(s)
Extracellular Vesicles , Calibration , Flow Cytometry , Humans , Reference Standards , Software
17.
J Virol ; 94(2)2020 01 06.
Article in English | MEDLINE | ID: mdl-31694951

ABSTRACT

Murine leukemia viruses (MLVs) have long been used as a research model to further our understanding of retroviruses. These simple gammaretroviruses have been studied extensively in various facets of science for nearly half a century, yet we have surprisingly little quantitative information about some of the basic features of these viral particles. These include parameters such as the genome packaging efficiency and the number of particles required for a productive infection. The reason for this knowledge gap relies primarily on the technical challenge of accurately measuring intact viral particles from infected cell supernatants. Virus-infected cells are well known to release soluble viral proteins, defective viruses, and extracellular vesicles (EVs) harboring viral proteins that may mimic viruses, all of which can skew virus titer quantifications. Flow virometry, also known as nanoscale flow cytometry or simply small-particle flow cytometry, is an emerging analytical method enabling high-throughput single-virus phenotypic characterizations. By utilizing the viral envelope glycoprotein (Env) and monodisperse light scattering characteristics as discerning parameters of intact virus particles, here, we analyzed the basic properties of Moloney MLV (M-MLV). We show that <24% of the total p30 capsid protein measured in infected cell supernatants is associated with intact viruses. We calculate that about one in five M-MLV particles contains a viral RNA genome pair and that individual intact particle infectivity is about 0.4%. These findings provide new insights into the characteristics of an extensively studied prototypical retrovirus while highlighting the benefits of flow virometry for the field of virology.IMPORTANCE Gammaretroviruses, or, more specifically, murine leukemia viruses (MLVs), have been a longstanding model for studying retroviruses. Although being extensively analyzed and dissected for decades, several facets of MLV biology are still poorly understood. One of the primary challenges has been enumerating total intact virus particles in a sample. While several analytical methods can precisely measure virus protein amounts, MLVs are known to induce the secretion of soluble and vesicle-associated viral proteins that can skew these measurements. With recent technological advances in flow cytometry, it is now possible to analyze viruses down to 90 nm in diameter with an approach called flow virometry. The technique has the added benefit of being able to discriminate viruses from extracellular vesicles and free viral proteins in order to confidently provide an intact viral particle count. Here, we used flow virometry to provide new insights into the basic characteristics of Moloney MLV.


Subject(s)
Flow Cytometry , Gene Products, env/metabolism , Genome, Viral , Moloney murine leukemia virus/metabolism , Retroviridae Infections/metabolism , Virion/metabolism , Animals , HEK293 Cells , Humans , Mice , NIH 3T3 Cells
19.
Sci Rep ; 9(1): 16039, 2019 11 05.
Article in English | MEDLINE | ID: mdl-31690751

ABSTRACT

The CytoFLEX is a novel semiconductor-based flow cytometer that utilizes avalanche photodiodes, wavelength-division multiplexing, enhanced optics, and diode lasers to maximize light capture and minimize optical and electronic noise. Due to an increasing interest in the use of extracellular vesicles (EVs) as disease biomarkers, and the growing desire to use flow cytometry for the analyses of biological nanoparticles, we assessed the light-scatter sensitivity of the CytoFLEX for small-particle detection. We found that the CytoFLEX can fully resolve 70 nm polystyrene and 98.6 nm silica beads by violet side scatter (VSSC). We further analyzed the detection limit for biological nanoparticles, including viruses and EVs, and show that the CytoFLEX can detect viruses down to 81 nm and EVs at least as small as 65 nm. Moreover, we could immunophenotype EV surface antigens, including directly in blood and plasma, demonstrating the double labeling of platelet EVs with CD61 and CD9, as well as triple labeling with CD81 for an EV subpopulation in one donor. In order to assess the refractive indices (RIs) of the viruses and EVs, we devised a new method to inversely calculate the RIs using the intensity vs. size data together with Mie-theory scatter efficiencies scaled to reference-particle measurements. Each of the viruses tested had an equivalent RI, approximately 1.47 at 405 nm, which suggests that flow cytometry can be more broadly used to easily determine virus sizes. We also found that the RIs of EVs increase as the particle diameters decrease below 150 nm, increasing from 1.37 for 200 nm EVs up to 1.61 for 65 nm EVs, expanding the lower range of EVs that can be detected by light scatter. Overall, we demonstrate that the CytoFLEX has an unprecedented level of sensitivity compared to conventional flow cytometers. Accordingly, the CytoFLEX can be of great benefit to virology and EV research, and will help to expand the use of flow cytometry for minimally invasive liquid biopsies by allowing for the direct analysis of antigen expression on biological nanoparticles within patient samples, including blood, plasma, urine and bronchoalveolar lavages.


Subject(s)
Antigens, CD/blood , Blood Platelets , Flow Cytometry/instrumentation , Nanoparticles/chemistry , Semiconductors , Adult , Blood Platelets/cytology , Blood Platelets/metabolism , Female , Humans , Male , Polystyrenes/chemistry , Silicon Dioxide/chemistry
20.
BMC Nephrol ; 20(1): 294, 2019 08 02.
Article in English | MEDLINE | ID: mdl-31375072

ABSTRACT

BACKGROUND: Although hemodialysis is a highly effective treatment for diffusive clearance of low molecular weight uremic toxins, its effect on circulating extracellular vesicles and submicron particles is less clear. The purpose of this study was to examine the impact of hemodialysis on circulating levels of submicron particles. METHODS: Plasma samples from patients were collected immediately before and after the mid-week hemodialysis session. Total submicron particles were assessed by nanoparticle tracking analysis and levels of endothelial (CD144+), platelet (CD41+), leukocyte (CD45+), and total (Annexin V+) membrane microparticles (MPs) were assessed by flow cytometry. RESULTS: Total submicron particle number was significantly lower post-dialysis with reductions in particles < 40 nm, 40-100 nm, and 100-1000 nm in size. Circulating annexin V+ MPs, platelet MPs, leukocyte MPs, and endothelial MPs were all reduced following dialysis. Assessment of protein markers suggested that extracellular vesicles were not present in the dialysate, but rather adsorbed to the dialysis membrane. CONCLUSIONS: In summary, hemodialysis is associated with reductions in circulating submicron particles including membrane MPs. Accordingly, there may be significant interdialytic variation in circulating submicron particles. Investigators interested in measuring extracellular vesicles in patients undergoing hemodialysis should therefore carefully consider the timing of biosampling.


Subject(s)
Extracellular Vesicles , Kidney Failure, Chronic/blood , Kidney Failure, Chronic/therapy , Renal Dialysis , Annexin A5/blood , Antigens, CD/blood , Blood Platelets/cytology , Blood Platelets/immunology , Cadherins/blood , Cell-Derived Microparticles , Cohort Studies , Female , Flow Cytometry , Hemodialysis Solutions/chemistry , Humans , Leukocyte Common Antigens/blood , Leukocytes/cytology , Leukocytes/immunology , Male , Middle Aged , Nanoparticles/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...