Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
AJNR Am J Neuroradiol ; 41(7): 1256-1262, 2020 07.
Article in English | MEDLINE | ID: mdl-32586967

ABSTRACT

BACKGROUND AND PURPOSE: Conventional single-shot FSE commonly used for fast MRI may be suboptimal for brain evaluation due to poor image contrast, SNR, or image blurring. We investigated the clinical performance of variable refocusing flip angle single-shot FSE, a variation of single-shot FSE with lower radiofrequency energy deposition and potentially faster acquisition time, as an alternative approach to fast brain MR imaging. MATERIALS AND METHODS: We retrospectively compared half-Fourier single-shot FSE with half- and full-Fourier variable refocusing flip angle single-shot FSE in 30 children. Three readers reviewed images for motion artifacts, image sharpness at the brain-fluid interface, and image sharpness/tissue contrast at gray-white differentiation on a modified 5-point Likert scale. Two readers also evaluated full-Fourier variable refocusing flip angle single-shot FSE against T2-FSE for brain lesion detectability in 38 children. RESULTS: Variable refocusing flip angle single-shot FSE sequences showed more motion artifacts (P < .001). Variable refocusing flip angle single-shot FSE sequences scored higher regarding image sharpness at brain-fluid interfaces (P < .001) and gray-white differentiation (P < .001). Acquisition times for half- and full-Fourier variable refocusing flip angle single-shot FSE were faster than for single-shot FSE (P < .001) with a 53% and 47% reduction, respectively. Intermodality agreement between full-Fourier variable refocusing flip angle single-shot FSE and T2-FSE findings was near-perfect (κ = 0.90, κ = 0.95), with an 8% discordance rate for ground truth lesion detection. CONCLUSIONS: Variable refocusing flip angle single-shot FSE achieved 2× faster scan times than single-shot FSE with improved image sharpness at brain-fluid interfaces and gray-white differentiation. Such improvements are likely attributed to a combination of improved contrast, spatial resolution, SNR, and reduced T2-decay associated with blurring. While variable refocusing flip angle single-shot FSE may be a useful alternative to single-shot FSE and, potentially, T2-FSE when faster scan times are desired, motion artifacts were more common in variable refocusing flip angle single-shot FSE, and, thus, they remain an important consideration before clinical implementation.


Subject(s)
Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Adolescent , Artifacts , Child , Child, Preschool , Female , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Infant , Infant, Newborn , Male , Retrospective Studies , Time Factors
2.
Br J Radiol ; 86(1028): 20130022, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23770539

ABSTRACT

OBJECTIVE: Single-shot diffusion-weighted (DW) echo planar imaging (EPI), which is commonly used for imaging the thyroid, is characterised by severe blurring and distortion. The objectives of this work were: 1, to show that a reduced-field of view (r-FOV) DW EPI technique can improve image quality; and 2, to investigate the effect of different reconstruction strategies on the resulting apparent diffusion coefficients (ADCs). METHODS: We implemented a single-shot, r-FOV DW EPI technique with a two-dimensional radiofrequency excitation pulse for DW imaging of the thyroid at 3T. Images were reconstructed using root sum of squares (SOS) and an optimal-B1 reconstruction (OBR). Phantom and in vivo experiments were performed to compare r-FOV and conventional full-FOV DW EPI with root SOS and OBR. RESULTS: r-FOV with OBR substantially improved image quality at 3T. In phantoms, r-FOV gave more accurate ADCs than full-FOV. In vivo r-FOV always gave lower ADC values with respect to the full-FOV technique irrespective of the reconstruction used and whether only two or multiple b-values were used to compute the ADCs. CONCLUSION: r-FOV DW EPI can reduce image blurring and distortion at the expense of a low signal-to-noise ratio. OBR is a promising reconstruction technique for accurate ADC measurements in lower signal-to-noise ratio regimes, although further studies are needed to characterise its performance. ADVANCES IN KNOWLEDGE: DW imaging of the thyroid at 3T could potentially benefit from r-FOV acquisition strategies, such as the r-FOV DW EPI technique proposed in this paper.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Thyroid Gland , Echo-Planar Imaging , Humans , Image Processing, Computer-Assisted , Phantoms, Imaging , Signal-To-Noise Ratio
3.
Eur J Vasc Endovasc Surg ; 41(2): 167-74, 2011 Feb.
Article in English | MEDLINE | ID: mdl-20869889

ABSTRACT

OBJECTIVES: Abdominal aortic aneurysms (AAAs), being predominantly atherosclerotic in nature, have underlying inflammatory activity. As it is well established that ultrasmall superparamagnetic iron oxide (USPIO) particles accumulate in the macrophages within atheromatous lesions, USPIO-enhanced magnetic resonance (MR) imaging can be potentially effective in the quantification of the associated inflammatory processes. METHODS: A total of 14 patients underwent USPIO-enhanced MR imaging using a 1.5T-MR system. Quantitative T(2)* and T(2) relaxation time data were acquired before and 36 h after UPSIO infusion at identical AAA locations. The pre- and post-USPIO-infusion relaxation times (T(2)(∗) and T(2)) were quantified and the correlation between pre- and post-USPIO infusion T(2)* and T(2) values was investigated. RESULTS: There was a significant difference between pre- and post-infusion T(2)* and T(2) values (both respective p-values = 0.005). A significant correlation between T(2)* and T(2) values post-USPIO infusion was observed (r = 0.90, p < 0.001), which indicates USPIO uptake by the aortic wall. CONCLUSIONS: Aortic wall inflammation using USPIO-enhanced MR imaging is feasible. Use of quantitative T(2) and T(2)* pulse sequences provides a quantitative method for assessing USPIO uptake by the aortic wall.


Subject(s)
Aortic Aneurysm, Abdominal/diagnosis , Aortic Rupture/diagnosis , Aortitis/diagnosis , Contrast Media , Dextrans , Magnetic Resonance Angiography , Magnetite Nanoparticles , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/complications , Aortic Rupture/etiology , Aortitis/complications , England , Feasibility Studies , Female , Humans , Image Interpretation, Computer-Assisted , Male , Predictive Value of Tests , Prognosis , Risk Assessment
4.
Br J Radiol ; 82 Spec No 1: S39-45, 2009 Jan.
Article in English | MEDLINE | ID: mdl-20348535

ABSTRACT

The aim of this study was to evaluate the mechanical triggers that may cause plaque rupture. Wall shear stress (WSS) and pressure gradient are the direct mechanical forces acting on the plaque in a stenotic artery. Their influence on plaque stability is thought to be controversial. This study used a physiologically realistic, pulsatile flow, two-dimensional, cine phase-contrast MRI sequence in a patient with a 70% carotid stenosis. Instead of considering the full patient-specific carotid bifurcation derived from MRI, only the plaque region has been modelled by means of the idealised flow model. WSS reached a local maximum just distal to the stenosis followed by a negative local minimum. A pressure drop across the stenosis was found which varied significantly during systole and diastole. The ratio of the relative importance of WSS and pressure was assessed and was found to be less than 0.07% for all time phases, even at the throat of the stenosis. In conclusion, although the local high WSS at the stenosis may damage the endothelium and fissure plaque, the magnitude of WSS is small compared with the overall loading on plaque. Therefore, pressure may be the main mechanical trigger for plaque rupture and risk stratification using stress analysis of plaque stability may only need to consider the pressure effect.


Subject(s)
Atherosclerosis/physiopathology , Carotid Stenosis/physiopathology , Aged , Blood Flow Velocity/physiology , Blood Pressure/physiology , Humans , Magnetic Resonance Angiography/methods , Male , Models, Cardiovascular , Pulsatile Flow/physiology , Rupture, Spontaneous/physiopathology , Stress, Mechanical