Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Indian J Clin Biochem ; 38(1): 51-58, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35465605

ABSTRACT

The vaccination efficacy can indirectly be assessed through the quantification of neutralizing antibodies. Very few data are available on Covishield efficacy in terms of neutralizing antibody expression upon vaccination. This study is focused on profiling of neutralizing antibody expression during and after the Covishield two shot vaccination and observing COVID-19 infection in vaccinated participants during the period. SARS CoV-2 neutralizing antibody concentrations in samples were estimated using electrochemiluminescence immunoassay kit for Lifotronics eCL8000. The sampling had been done sequentially at 45th, 85th day after 1st dose and 15th day after 2nd dose Covishield vaccination. Parallelly, in order to confirm the total SARS CoV-2 IgG response in COVID-19 infection, measured the IgG using SARS CoV-2 IgG lateral flow immunoassay test kit. The subjects previously infected with COVID-19 before 1st dose vaccination demonstrated high neutralizing antibody (> 10AU/ml). In COVID-19 uninfected subjects, there was a sudden incline in neutralizing antibody after the 2nd dose. Infection with SARS CoV-2 between 1st and 2nd dose of Covishield vaccination implicate that the level of neutralizing antibody in serum after 1st dose was not adequate to combat the virus and prevent infection. We observed COVID-19 infection in participants even after 2nd dose of vaccination. Interestingly, there was no protection against SARS CoV-2 even with a high neutralizing antibody expression of 188.5 AU/mL after the 2nd dose. Findings of Covishield efficacy in different cohort samples before and after 2 doses of Covishield vaccination provide impetus for improvement or development of next generation vaccines.

2.
J Appl Lab Med ; 7(4): 871-880, 2022 06 30.
Article in English | MEDLINE | ID: mdl-35689333

ABSTRACT

BACKGROUND: Currently, the rapid antigen test (RAT) and reverse transcriptase-polymerase chain reaction (RT-PCR) are considered the main stakeholders in COVID-19 diagnosis. In RT-PCR, any of at least 2 evolutionary conserved genes (RdRP, E-, N-, ORF1ab gene) and S-gene of SARS-CoV-2 are endorsed, and in RAT, the nucleocapsid antigen (N-Ag) of SARS-CoV-2 is considered due to its stability and fewer chances of mutation effects. In the present work, we evaluated the performance of the AG-Q COVID-19 N-Ag self-test kit and conducted a validation study in comparison with the RT-PCR. METHODS: AG-Q COVID-19 N-Ag rapid test kit is an Indian Council of Medical Research (ICMR) approved product developed and marketed by Agappe Diagnostics Limited. The RT-PCR assay was performed with a COVIPATH COVID-19 RT-PCR kit from Thermo Fisher Scientific. RESULTS: We observed 19 false-negative results in antigen self-tests, including samples of threshold cycle (Ct) values 22/22 (N-gene/ORF1ab-gene) in RT-PCR, indicating inadequate sampling by the patients in self-tests, leading to false-negative results and increased chances of the disease spreading. Based on the RT-PCR Ct value vs antigen self-test comparison, it is evident that proper sampling is crucial in performing antigen self-tests. Also, there were weak positive results in antigen self-tests with a Ct value of 18/19 in RT-PCR. CONCLUSIONS: Although the sensitivity and diagnostic accuracy offered by the AG-Q COVID-19 N-Antigen self-test in comparison with RT-PCR fulfills the ICMR tenets for RAT, this study recommends the laboratory/hospital-based RAT execution would be appropriate, rather than the self-test.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , Nucleocapsid/genetics , RNA-Dependent RNA Polymerase , RNA-Directed DNA Polymerase , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , Self-Testing , Sensitivity and Specificity
3.
Indian J Clin Biochem ; 37(3): 349-355, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34421232

ABSTRACT

Upon SARS CoV-2 infection, humoral immune system triggers production of anti-SARS CoV-2 IgM and IgG antibodies. Currently, antibodies against SARS CoV-2 spike protein receptor binding domain play a central role in disease protection, making them potential target for in vitro diagnostics applications. This study determines the expression level and sustainability of anti-receptor binding domain (RBD) SARS CoV-2 IgG in post COVID-19 patients. Anti-RBD SARS CoV-2 IgG antibodies in patient serum were analysed by standardised indirect ELISA using SARS CoV-2 spike receptor binding domain protein and HRP conjugated anti-human IgG antibody (anti-h IgG). The study was conducted using 35 adult patient samples with confirmed SARS CoV-2 infection. Additionally, correlation between antibody response after each stage and disease symptoms in post COVID-19 patients were studied. Maximum antibody titre was seen at Day 40 and decreased relatively to Day 180 in antibody positive samples when compared with controls. Overall, more IgG antibody expression is observed in patients who suffered from loss of smell and taste at Day 40. 71% of the positive subjects in this study showed high SARS CoV-2 IgG antibody concentration of above 10 ng/mL and 37% showed strong antibody concentration above 20 ng/mL at the peak of seroconversion.

4.
Indian J Clin Biochem ; 36(2): 208-212, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33867712

ABSTRACT

The development of Lateral Flow Immunochromatography Assay can be divided into two levels; standardizing membrane characteristics and optimizing molecular level immunoassay reaction between analyte and detector molecules. In the preliminary phase the reaction specificity of capture and detector antibodies with the analyte has to be checked with other techniques like ELISA. Molarity and pH of conjugation buffer have prime importance in the immunoreaction among analyte and antibodies. Epitope mapping of the capture and detector antibodies is also recommended to confirm the specificity of the assay. Standardization of membrane characteristics directly relates to the sensitivity of the assay through its porosity, hydrophobicity, protein holding/releasing capacity and wicking rate. Under optimised condition a perfect Lateral Flow Immunochromatography Assay should have high on-rate (target binding efficiency), low off-rate (target releasing efficiency) and low Cross-reactivity. In this manuscript, we share our experience, especially on developmental strategies and troubleshooting, that we have experienced during Lateral Flow Immunochromatography Assay kit development.

SELECTION OF CITATIONS
SEARCH DETAIL
...