Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 10 de 10
1.
Anal Chim Acta ; 1093: 160-167, 2020 Jan 06.
Article En | MEDLINE | ID: mdl-31735210

In this study, poly(butyl methacrylate-co-ethyleneglycol dimethacrylate) polymeric monoliths were in situ developed within 0.75 mm i.d. poly(ethylene-co-tetrafluoroethylene) (ETFE) tubing by UV polymerization via three different free-radical initiators (α,α'-azobisisobutyronitrile (AIBN), 2,2-dimethoxy-2-phenylacetophenone (DMPA) and 2-methyl-4'-(methylthio)-2-morpholinopropiophenone (MTMPP). The influence of the nature of each photo-initiator and irradiation time on the morphological features of the polymer was investigated by scanning electron microscopy, and the chromatographic properties of the resulting microbore columns were evaluated using alkyl benzenes as test substances. The beds photo-initiated with MTMPP gave the best performance (minimum plate heights of 38 µm for alkyl benzenes) and exhibited a satisfactory reproducibility in the chromatographic parameters (RSD < 11%). These monolithic columns were also successfully applied to the separation of phenylurea herbicides, proteins and a tryptic digest of ß-casein.


Acetophenones/chemistry , Chromatography, High Pressure Liquid/instrumentation , Morpholines/chemistry , Nitriles/chemistry , Polymethacrylic Acids/chemistry , Polytetrafluoroethylene/analogs & derivatives , Propiophenones/chemistry , Acetophenones/radiation effects , Caseins/isolation & purification , Chromatography, High Pressure Liquid/methods , Herbicides/isolation & purification , Methacrylates/chemistry , Morpholines/radiation effects , Nitriles/radiation effects , Peptide Fragments/isolation & purification , Phenylurea Compounds/isolation & purification , Polymerization , Polymethacrylic Acids/chemical synthesis , Polytetrafluoroethylene/chemistry , Propiophenones/radiation effects , Ultraviolet Rays
2.
Talanta ; 187: 216-222, 2018 Sep 01.
Article En | MEDLINE | ID: mdl-29853038

In this study, porous polymer monoliths were in situ synthesized in fluoropolymers tubing to prepare microbore HPLC columns. To ensure the formation of robust homogeneous polymer monoliths in these housing supports, the inner surface of fluoropolymer tubing was modified in a two-step photografting process. Raman spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification of the inner poly(ethylene-co-tetrafluoroethylene) (ETFE) wall and the subsequent attachment of a monolith onto the wall. Poly(glycidyl methacrylate-co-divinylbenzene), poly(butyl methacrylate-co-ethyleneglycol dimethacrylate) and poly(styrene-co-divinylbenzene) monoliths were in situ synthesized by thermal polymerization within the confines of surface vinylized ETFE tubes. The resulting monoliths exhibited good permeability and mechanical stability (pressure resistance up to 9 MPa). The chromatographic performance of these different monolithic columns was evaluated via the separation of alkyl benzenes and proteins in a conventional HPLC system.

3.
Talanta ; 180: 162-167, 2018 Apr 01.
Article En | MEDLINE | ID: mdl-29332795

A polymeric material modified with magnetic nanoparticles (MNPs) has been synthesized and evaluated as sorbent both for solid-phase extraction (SPE) and dispersive magnetic solid-phase extraction (MSPE) of phospholipids (PLs) in human milk samples. The synthesized sorbent was characterized by scanning electron microscopy and its iron content was also determined. Several experimental variables that affect the extraction performance (e.g. loading solvent, breakthrough volume and loading capacity) were investigated and a comparison between conventional SPE and MSPE modalities was done. The proposed method was satisfactorily applied to the analysis of PLs in human milk fat extracts in different lactation stages and the extracted PLs were determined by means of hydrophilic interaction liquid chromatography using evaporative light scattering detection.


Epoxy Compounds/chemistry , Magnetite Nanoparticles/chemistry , Methacrylates/chemistry , Milk, Human/chemistry , Phospholipids/isolation & purification , Solid Phase Extraction/methods , Chromatography, High Pressure Liquid/methods , Humans , Hydrophobic and Hydrophilic Interactions , Limit of Detection , Phospholipids/analysis
4.
Anal Chim Acta ; 960: 160-167, 2017 Apr 01.
Article En | MEDLINE | ID: mdl-28193359

In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch®), or mixtures of H2O2 and H2SO4, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification of the tubing wall and the stable anchorage of monolith to the wall, respectively. Special emphasis was also put on the reduction of the unwanted effects of shrinking of monolith during polymerization, by using an external proper mold and by selecting the adequate monomers in order to increase the flexibility of the polymer. Poly(glycidyl methacrylate-co-divinylbenzene) monoliths were in situ synthesized by thermal polymerization within the confines of surface-vinylized PTFE tubes. The modified PTFE tubing tightly held the monolith, and the monolithic column exhibited good pressure resistance up to 20 MPa. The column performance was also evaluated via the isocratic separation of a series of alkylbenzenes in the reversed-phase mode. The optimized monolithic columns gave plate heights ranged between 70 and 80 µm. The resulting monoliths were also satisfactorily applied to the separation of proteins.


Chromatography, Reverse-Phase/methods , Polytetrafluoroethylene/chemistry , Chromatography, Reverse-Phase/instrumentation , Equipment Design
5.
Photochem Photobiol Sci ; 15(5): 626-34, 2016 05 11.
Article En | MEDLINE | ID: mdl-27079156

A liquid chromatography method with post-column photoinduced chemiluminescence (PICL) detection is proposed for the simultaneous determination of eight carbamate pesticides, namely aldicarb, butocarboxim, ethiofencarb, methomyl, methiocarb, thiodicarb, thiofanox and thiophanate-methyl. After chromatographic separation, quinine (sensitizer) was incorporated and the flow passed through an UV lamp (67 s of irradiation time) to obtain the photoproducts, which reacted with acidic Ce(iv) and provided a CL emission. The PICL method showed great selectivity for carbamate pesticides containing sulphur in their chemical structure. A solid-phase extraction process increased sensitivity (LODs ranging from 0.06 to 0.27 ng mL(-1)) and allowed the carbamate pesticides in surface and ground water samples to be determined, with recoveries in the range 87-110% (except for thiophanate-methyl, whose recoveries were between 60 and 75%). The intra- and inter-day precision was evaluated, with RSD ranging from 1.1 to 7.5% and from 2.6 to 12.3%, respectively. A discussion about the PICL mechanism is also included.


Carbamates/analysis , Groundwater/analysis , Luminescent Measurements/methods , Pesticides/analysis , Water Pollutants, Chemical/analysis , Chromatography, High Pressure Liquid/instrumentation , Chromatography, High Pressure Liquid/methods , Equipment Design , Limit of Detection , Luminescence , Luminescent Measurements/instrumentation , Solid Phase Extraction/instrumentation , Solid Phase Extraction/methods
6.
Anal Bioanal Chem ; 402(3): 1289-96, 2012 Jan.
Article En | MEDLINE | ID: mdl-22120000

This paper reports an economic, simple, and rapid FI-CL method for the determination of MCPA. This method requires simple instrumentation and it is fast enough to be used in routine analyses. A chemiluminescence signal is generated by reaction between photodegraded MCPA and ferricyanide solution in alkaline medium. All physical and chemical parameters in the flow injection chemiluminescence system were optimized in the experimental setting. To eliminate interference, a solid-phase extraction stage with SDB-1 cartridges and ethanol elution is applied. The signal-MCPA concentration relation is linear in concentration intervals between 0.0015 and 0.6 µg·mL(-1). The calibration lines are statistically similar in different working conditions: standards with ethanol without extraction and standards with ethanol and extraction, allowing standards to be excluded from the extraction step, which simplifies the process. The detection limit (DL) is 0.5 ng·mL(-1), which is the same order as the maximum limit established in legislation regarding pesticide limits in water destined for human consumption. A DL of 0.13 ng·mL(-1) can be reached if a sample of 100 mL is preconcentrated. The interday variance coefficient is 3% and the sample throughput is 90 h(-1). The water analysis method is efficient with relative error percentages lower than 5% with respect to the added concentration.


2-Methyl-4-chlorophenoxyacetic Acid/analysis , Flow Injection Analysis/instrumentation , Herbicides/analysis , Luminescent Measurements/instrumentation , Water Pollutants, Chemical/analysis , Water/analysis , 2-Methyl-4-chlorophenoxyacetic Acid/isolation & purification , Equipment Design , Flow Injection Analysis/economics , Flow Injection Analysis/methods , Herbicides/isolation & purification , Limit of Detection , Luminescent Measurements/economics , Luminescent Measurements/methods , Solid Phase Extraction/economics , Solid Phase Extraction/instrumentation , Solid Phase Extraction/methods , Water Pollutants, Chemical/isolation & purification
7.
Anal Bioanal Chem ; 398(7-8): 3175-82, 2010 Dec.
Article En | MEDLINE | ID: mdl-20890748

In this work, a fast, simple and economic method is proposed for the determination of imazalil in water samples by flow injection photoinduced chemiluminescence. In this method, imazalil degrades in basic media through the use of a photoreactor, and the resulting photofragments react with ferricyanide and generate the direct chemiluminescence signal. To the authors' knowledge, this is the first time that a chemiluminescence method has been proposed for the determination of this fungicide. All physical and chemical parameters in the flow injection chemiluminescence system were optimized in the experimental setting. In the absence of preconcentration, the linear dynamic range for imazalil was 0.75-5 mg L(-1) and the detection limit was 0.171 mg L(-1). The application of solid-phase extraction with C18 cartridges allowed the elimination of interference ions, the reduction of the linear dynamic range to 15-100 µg L(-1), and a detection limit of 3.4 µg L(-1). This detection limit is below the maximum concentration level established by the Regulations of the Hydraulic Public Domain for pesticide dumping. The sample throughput after solid-phase extraction of the analyte was 12 samples h(-1). The intraday and interday coefficients of variation were below 9.9% in all cases. This method was applied to the analysis of environmental water samples, and recoveries of between 95.7 and 110% were obtained.


Flow Injection Analysis/methods , Fungicides, Industrial/analysis , Imidazoles/analysis , Luminescent Measurements/methods , Solid Phase Extraction/methods , Water Pollutants/analysis , Water/analysis , Ferricyanides/chemistry , Flow Injection Analysis/instrumentation , Fungicides, Industrial/chemistry , Imidazoles/chemistry
8.
Anal Chim Acta ; 632(2): 296-303, 2009 Jan 26.
Article En | MEDLINE | ID: mdl-19110108

Biopartitioning micellar chromatography (BMC), a mode of micellar liquid chromatography that uses micellar mobile phases of Brij35 in adequate experimental conditions, has demonstrated to be useful in mimicking the drug partitioning process into biological systems. In this paper, the usefulness of BMC for predicting the partition coefficients from blood to lung, blood to liver, blood to fat and blood to skin is demonstrated. PLS2 and multiple linear regression (MLR) models based on BMC retention data are proposed and compared with other ones reported in bibliography. The proposed models present better or similar descriptive and predictive capability.


Adipose Tissue/metabolism , Chromatography, Liquid/methods , Liver/metabolism , Lung/metabolism , Pharmaceutical Preparations/blood , Pharmacokinetics , Skin/metabolism , Animals , Computational Biology , Humans , Linear Models , Micelles , Pharmaceutical Preparations/analysis , Quantitative Structure-Activity Relationship , Rabbits , Rats , Tissue Distribution
9.
Eur J Med Chem ; 42(11-12): 1396-402, 2007.
Article En | MEDLINE | ID: mdl-17482318

Mutagenicity is a toxicity endpoint associated with the chronic exposure to chemicals. Aromatic amines have considerable industrial and environmental importance due to their widespread use in industry and their mutagenic capacity. Biopartitioning micellar chromatography (BMC), a mode of micellar liquid chromatography that uses micellar mobile phases of Brij35 in adequate experimental conditions, has demonstrated to be useful in mimicking the drug partitioning process into biological systems. In this paper, the usefulness of BMC for predicting mutagenicity of aromatic amines is demonstrated. A multiple linear regression (MLR) model based on BMC retention data is proposed and compared with other ones reported in bibliography. The proposed model present better or similar descriptive and predictive capability.


Amines/chemistry , Amines/toxicity , Chromatography/methods , Micelles , Mutagenesis , Computer Simulation , Least-Squares Analysis , Models, Biological , Quantitative Structure-Activity Relationship
10.
Biomed Chromatogr ; 21(1): 21-8, 2007 Jan.
Article En | MEDLINE | ID: mdl-17080499

The determination of highly hydrophobic basic compounds by means of conventional reversed-phase liquid chromatographic methods has several drawbacks. Owing to the characteristics of micellar liquid chromatography (MLC) and capillary electrophoresis (CE), these techniques could be advantageous alternatives to reversed-phase chromatographic methods for the determination of these kinds of compounds. The objective of this study was to develop and compare MLC and CE methods for the determination of antipsychotic basic drugs (amitryptiline, haloperidol, perphenazine and thioridazine) in pharmaceutical preparations. The chromatographic determination of the analytes was performed on a Kromasil C(18) analytical column; the mobile phase was 0.04 m cetyltrimethylammonium bromide (CTAB), at pH 3, containing 5% 1-butanol, at a flow rate of 1 mL/min. The CE separation was performed in a fused-silica capillary with a 50 mm tris-(hydroxymethyl)-aminomethane buffer, pH 7, at an applied voltage of 20 kV, using barbital as internal stardard. The proposed methods are suitable for a reliable quantitation of these compounds in the commercial tablets and drops in terms of accuracy and precision and require a very simple pre-treatment of the samples. By comparing the performance characteristics and experimental details of the MLC and CE methods we conclude that CE seems to be slightly better than MLC in the determination of highly hydrophobic compounds in pharmaceuticals in terms of resolution and economy, taking into account that the limits of detection are not a handicap in pharmaceutical samples.


Antipsychotic Agents/analysis , Antipsychotic Agents/chemistry , Chromatography, Liquid/methods , Electrophoresis, Capillary/methods , Pharmaceutical Preparations/chemistry , Calibration , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
...