ABSTRACT
X-ray absorption fine-structure (XAFS) spectroscopy can assess the chemical speciation of the elements providing their coordination and oxidation state, information generally hidden to other techniques. In the case of trace elements, achieving a good quality XAFS signal poses several challenges, as it requires high photon flux, counting statistics and detector linearity. Here, a new multi-element X-ray fluorescence detector is presented, specifically designed to probe the chemical speciation of trace 3d elements down to the p.p.m. range. The potentialities of the detector are presented through a case study: the speciation of ultra-diluted elements (Fe, Mn and Cr) in geological rocks from a calcareous formation related to the dispersal processes from Ontong (Java) volcanism (mid-Cretaceous). Trace-elements speciation is crucial in evaluating the impact of geogenic and anthropogenic harmful metals on the environment, and to evaluate the risks to human health and ecosystems. These results show that the new detector is suitable for collecting spectra of 3d elements in trace amounts in a calcareous matrix. The data quality is high enough that quantitative data analysis could be performed to determine their chemical speciation.
Subject(s)
Trace Elements , Ecosystem , Exercise Test , Humans , Metals , Trace Elements/analysis , X-Ray Absorption SpectroscopyABSTRACT
We report on a laser system based on difference frequency generation (DFG) to produce tunable, narrow-linewidth (<30pm), and comparatively high-energy mid-IR radiation in the 6.8 µm region. The system exploits a lithium thioindate (LiInS2) nonlinear crystal and nanosecond pulses generated by single-frequency Nd:YAG and Cr:forsterite lasers at 1064 and 1262 nm, respectively. Two experimental configurations are used: in the first one, single-pass, the mid-IR energy achieved is 205 µJ. Additional increments, up to 540 µJ, are obtained by performing double-pass through the nonlinear crystal. This laser has been developed for high-resolution photon-hungry spectroscopy in the mid-IR.
ABSTRACT
We present the design of a Cr:forsterite based single-frequency master-oscillator power-amplifier laser system delivering much higher output energy compared to previous literature reports. The system has four amplifying stages with two-pass configuration each, thus enabling the generation of 24 mJ output energy in the spectral region around 1262 nm. It is demonstrated that the presented Cr:forsterite amplifier preserves high spectral and pulse quality, allowing a straightforward energy scaling. This laser system is a promising tool for tunable nonlinear down-conversion to the mid-infrared spectral range and will be a key building block in a system for high-resolution muonic hydrogen spectroscopy in the 6.8 µm range.
ABSTRACT
In this work we describe the instrument Sileye-3/Alteino, placed on board the International Space Station in April 2002. The instrument is constituted by an Electroencephalograph and a cosmic ray silicon detector. The scientific aims include the investigation of the Light Flash phenomenon, the measurement of the radiation environment and the nuclear abundance inside the ISS and the study of astronaut brain activity in space when subject to cosmic rays.