Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 10 de 10
1.
Radiat Prot Dosimetry ; 198(6): 358-369, 2022 May 13.
Article En | MEDLINE | ID: mdl-35511688

New measurement methods and equipment for correct 5G New Radio (NR) electromagnetic field (EMF) in-situ exposure assessment of instantaneous time-averaged exposure (Eavg) and maximum extrapolated field exposure (Emax) are proposed. The different options are investigated with in-situ measurements around 5G NR base stations (FR1) in different countries. The maximum electric field values satisfy the ICNIRP 2020 limit (maximum 7.7%). The difference between Emax and Eavg is <3 dB for the different measurement equipment at multiple sites in case there is only self-generated traffic. However, in a more realistic scenario, Eavg cannot be used to assess the exposure correctly due to influence of other users as the spatial distribution of user equipment (UE) influences Eavg, while Emax is not affected. However, when multiple UEs are collocated, there is no influence of the number of UEs. A broadband measurement can give a first impression of the RF-EMF exposure up to 700 m, but is not enough to assess the 5G-NR exposure.


Cell Phone , Radio Waves , Electricity , Electromagnetic Fields , Environmental Exposure
2.
Sensors (Basel) ; 22(5)2022 Feb 22.
Article En | MEDLINE | ID: mdl-35270862

In an increasingly wireless world, spatiotemporal monitoring of the exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) is crucial to appease public uncertainty and anxiety about RF-EMF. However, although the advent of smart city infrastructures allows for dense networks of distributed sensors, the costs of accurate RF sensors remain high, and dedicated RF monitoring networks remain rare. This paper describes a comprehensive study comprising the design of a low-cost RF-EMF sensor node capable of monitoring four frequency bands used by wireless telecommunications with an unparalleled temporal resolution, its application in a small-scale distributed sensor network consisting of both fixed (on building façades) and mobile sensor nodes (on postal vans), and the subsequent analysis of over a year of data between January 2019 and May 2020, during which slightly less than 10 million samples were collected. From the fixed nodes' results, the potential errors were determined that are induced when sampling at lower speeds (e.g., one sample per 15 min) and measuring for shorter periods of time (e.g., a few weeks), as well as an adequate resolution (30 min) for diurnal and weekly temporal profiles which sufficiently preserves short-term variations. Furthermore, based on the correlation between the sensors, an adequate density of 100 sensor nodes per km2 was deduced for future networks. Finally, the mobile sensor nodes were used to identify potential RF-EMF exposure hotspots in a previously unattainable area of more than 60 km2. In summary, through the analysis of a small number of RF-EMF sensor nodes (both fixed and mobile) in an urban area, this study offers invaluable insights applicable to future designs and deployments of distributed RF-EMF sensor networks.


Cell Phone , Electromagnetic Fields , Cities , Environmental Exposure/analysis , Radio Waves
3.
Environ Int ; 156: 106711, 2021 11.
Article En | MEDLINE | ID: mdl-34153890

BACKGROUND: Exposure to radiofrequency electromagnetic fields (RF-EMF) is often measured with personal exposimeters, but the accuracy of measurements can be hampered as carrying the devices on-body may result in body shielding. Further, the compact design may compromise the frequency selectivity of the sensor. The aim of this study was to compare measurements obtained using a multi-band body-worn distributed-exposimeter (BWDM) with two commercially available personal exposimeters (ExpoM-RF and EmeSpy 200) under real-life conditions. METHODS: The BWDM measured power density in 10 frequency bands (800, 900, 1800, 2100, 2600 MHz, DECT 1900 MHz, WiFi 2.4 GHz; with separate uplink/downlink bands for 900, 1800 and 2100 MHz); using 20 separate antennas integrated in a vest and placed on diametrically opposite locations on the body, to minimize body-shielding. RF-EMF exposure data were collected from several microenvironments (e.g. shopping areas, train stations, outdoor rural/ urban residential environments, etc.) by walking around pre-defined areas/routes in Belgium, Spain, France, the Netherlands and Switzerland. Measurements were taken every 1-4 s with the BWDM in parallel with an ExpoM-RF and an EmeSpy 200 exposimeter. We calculated medians and interquartile ranges (IQRs) and compared difference, ratios and correlations of geometric mean RF-EMF exposure levels per microenvironment as measured with the exposimeters and the BWDM. RESULTS: Across 267 microenvironments, medians and IQR of total BWDM measured RF-EMF exposure was 0.13 (0.05-0.33) mW/m2. Difference: IQR of exposimeters minus BWDM exposure levels was -0.011 (-0.049 to 0.0095) mW/m2 for the ExpoM-RF and -0.056 (-0.14 to -0.017) for the EmeSpy 200; ratios (exposimeter/BWDM) of total exposure had an IQR of 0.79 (0.55-1.1) for the ExpoM-RF and 0.29 (0.22-0.38) for the EmeSpy 200. Spearman correlations were 0.93 for the ExpoM-RF vs the BWDM and 0.96 for the EmeSpy 200 vs the BWDM. DISCUSSION AND CONCLUSIONS: Results indicate that exposimeters worn on-body provide somewhat lower total RF-EMF exposure as compared to measurements conducted with the BWDM, in line with effects from body shielding. Ranking of exposure levels of microenvironments showed high correspondence between the different device types. Our results are informative for the interpretation of existing epidemiological research results.


Cell Phone , Electromagnetic Fields , Electromagnetic Fields/adverse effects , Environmental Exposure , Radio Waves/adverse effects , Spain , Switzerland
4.
Environ Res ; 183: 109196, 2020 04.
Article En | MEDLINE | ID: mdl-32032814

This paper describes radiofrequency (RF) electromagnetic field (EMF) measurements in the vicinity of single and banks of advanced metering infrastructure (AMI) smart meters. The measurements were performed in a meter testing and distribution facility as well as in-situ at five urban locations. The measurements consisted of gauging the RF environment at the place of assessment, evaluating the worst-case electric-field levels at various positions around the assessed AMI meter configuration (spatial assessment), which ranged from a single meter to a bank of 81 m, and calculating the duty cycle of the system, i.e. the fraction of time that the AMI meters were actually transmitting (12-h temporal assessment). Both in-situ and in the meter facility, the maximum field levels at 0.3 m from the meter configurations were 10-13 V/m for a single meter and 18-38 V/m for meter banks with 20-81 m. Furthermore, 6-min average duty cycles of 0.01% (1 m) up to 13% (81-m bank) were observed. Next, two general statistical models (one for a single meter and one for a meter bank) were constructed to predict the electric-field strength as a function of distance to any configuration of the assessed AMI meters. For all scenarios, the measured exposure levels (at a minimum distance of 0.3 m) were well below the maximum permissible exposure limits issued by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), the U.S. Federal Communications Commission (FCC), and the Institute of Electrical and Electronics Engineers (IEEE). Indeed, the worst-case time-average exposure level at a distance of 0.3 m from an AMI installation was 5.39% of the FCC/IEEE and 9.43% of the ICNIRP reference levels.


Electromagnetic Fields , Environmental Exposure , Radio Waves , Electricity , Environmental Monitoring , Models, Statistical , Radiation, Ionizing
5.
Health Phys ; 116(6): 776-788, 2019 06.
Article En | MEDLINE | ID: mdl-30883437

The advent of the Internet of things comes with a huge increase in wirelessly communicating devices in our environment. For example, smart energy-consumption meters are being widely deployed in residences from which they communicate their state using radiofrequency networks. Accurate characterization of the radiofrequency emissions from emerging residential wireless solutions is important to inform the public about the potential impact on their exposure to radiofrequency electromagnetic fields. A new measurement procedure to determine the exposure from residential radiofrequency devices is proposed by assessing the peak emitted fields at various distances and the proportion of time they transmit (duty cycle). Radiofrequency emissions from 55 residential devices were measured in 10 residences (Belgium and France) and compared to environmental levels, emissions from 41 mobile phones, and international standards. Overall, residential levels of radiofrequency electromagnetic field exposure are low. In addition to the continuous environmental exposure, wireless access points (due to frequent use) and especially mobile phones and other personal communication devices (due to their use close to the body) continue to represent the bulk of the radiofrequency electromagnetic field exposure in the smart home. However, some residential devices can significantly increase the exposure if their duty cycles are high enough (>10%), especially when held or used close to the body. Individual smart meters, on the other hand, will contribute only little in general, despite emissions of up to 20 V m at 50 cm, due to their low duty cycles (maximum 1%) and locations.


Cell Phone/statistics & numerical data , Electromagnetic Fields , Environmental Exposure/analysis , Radiation Monitoring/instrumentation , Radio Waves , Electricity , Humans
6.
Environ Res ; 162: 81-96, 2018 04.
Article En | MEDLINE | ID: mdl-29289859

The aims of this study were to: i) investigate the repeatability and representativeness of personal radio frequency-electromagnetic fields (RF-EMFs) exposure measurements, across different microenvironments, ii) perform simultaneous evaluations of personal RF-EMF exposures for the whole body and the head, iii) validate the data obtained with a head-worn personal distributed exposimeter (PDE) against those obtained with an on-body worn personal exposimeter (PEM). Data on personal and head RF-EMF exposures were collected by performing measurements across 15 microenvironments in Melbourne, Australia. A body-worn PEM and a head-worn PDE were used for measuring body and head exposures, respectively. The summary statistics obtained for total RF-EMF exposure showed a high representativeness (r2 > 0.66 for two paths in the same area) and a high repeatability over time (r2 > 0.87 for repetitions of the same path). The median head exposure in the 900MHz downlink band ranged between 0.06V/m and 0.31V/m. The results obtained during simultaneous measurements using the two devices showed high correlations (0.42 < r2 < 0.94). The highest mean total RF-EMF exposure was measured in Melbourne's central business district (0.89V/m), whereas the lowest mean total exposure was measured in a suburban residential area (0.05V/m). This study shows that personal RF-EMF microenvironmental measurements in multiple microenvironments have high representativeness and repeatability over time. The personal RF-EMF exposure levels (i.e. body and head exposures) demonstrated moderate to high correlations.


Electromagnetic Fields , Environmental Exposure , Environmental Monitoring , Australia , Housing , Radio Waves , Reproducibility of Results
7.
Sensors (Basel) ; 18(1)2018 Jan 18.
Article En | MEDLINE | ID: mdl-29346280

A multi-band Body-Worn Distributed exposure Meter (BWDM) calibrated for simultaneous measurement of the incident power density in 11 telecommunication frequency bands, is proposed. The BDWM consists of 22 textile antennas integrated in a garment and is calibrated on six human subjects in an anechoic chamber to assess its measurement uncertainty in terms of 68% confidence interval of the on-body antenna aperture. It is shown that by using multiple antennas in each frequency band, the uncertainty of the BWDM is 22 dB improved with respect to single nodes on the front and back of the torso and variations are decreased to maximum 8.8 dB. Moreover, deploying single antennas for different body morphologies results in a variation up to 9.3 dB, which is reduced to 3.6 dB using multiple antennas for six subjects with various body mass index values. The designed BWDM, has an improved uncertainty of up to 9.6 dB in comparison to commercially available personal exposure meters calibrated on body. As an application, an average incident power density in the range of 26.7-90.8 µW·m - 2 is measured in Ghent, Belgium. The measurements show that commercial personal exposure meters underestimate the actual exposure by a factor of up to 20.6.


Radio Waves , Belgium , Calibration , Electromagnetic Fields , Humans , Radiation Monitoring , Uncertainty
8.
Environ Res ; 154: 160-170, 2017 04.
Article En | MEDLINE | ID: mdl-28086101

Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300Hz to 1MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6kHz and 300kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20cm were 41.5V/m and 2.7A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20cm and beyond (maximum exposure quotients EQE 1.0 and EQH 0.13).


Electromagnetic Fields/adverse effects , Environmental Exposure/adverse effects , Housing , Lighting/adverse effects , Magnetic Fields/adverse effects , Belgium , Environmental Monitoring , Humans , Slovenia , United Kingdom
9.
Radiat Prot Dosimetry ; 168(2): 212-22, 2016 Feb.
Article En | MEDLINE | ID: mdl-25956787

In situ exposure of electric fields of 11 microwave ovens is assessed in an occupational environment and in an office. Measurements as a function of distance without load and with a load of 275 ml of tap water were performed at distances of <1 m. The maximal measured field was 55.2 V m(-1) at 5 cm from the oven (without load), which is 2.5 and 1.1 times below the International Commission on Non-Ionizing Radiation Protection reference level for occupational exposure and general public exposure, respectively. For exposure at distances of >1 m, a model of the electric field in a realistic environment is proposed. In an office scenario, switching on a microwave oven increases the median field strength from 91 to 145 mV m(-1) (+91 %) in a traditional Wireless Local Area Network (WLAN) deployment and from 44 to 92 mV m(-1) (+109 %) in an exposure-optimised WLAN deployment.


Electromagnetic Fields , Microwaves , Occupational Exposure/analysis , Radiation Monitoring , Radio Waves , Wireless Technology , Humans , Models, Theoretical
10.
Radiat Prot Dosimetry ; 164(3): 252-64, 2015 Apr.
Article En | MEDLINE | ID: mdl-25125596

In this study, in situ exposure assessment of both electric and magnetic fields of different intermediate frequency (IF) sources is investigated. The authors investigated smart boards and touchscreens, energy-saving bulbs, fluorescent lamps, a portable hearing unit and an electrosurgical unit (ESU). For most of these sources, the electric field is the dominating quantity. International Commission on Non-Ionizing Radiation Protection reference levels are exceeded for touchscreens (44 kHz: up to 155.7 V m(-1) at 5 cm), energy-saving bulbs (38-52 kHz: up to 117.3 V m(-1)), fluorescent lamps (52 kHz: up to 471 V m(-1) at 5 cm) and ESUs (up to 920 kHz: 792 V m(-1) at 0.5 cm). Magnetic field strengths up to 1.8 and 10.5 A m(-1) were measured close to the ESU and portable hearing unit (69 V m(-1)), respectively. Large differences of measured field values exist among the various operating modes of the IF equipment. Compliance distances for general public range from 15.3 cm (touchscreen) to 25 cm (fluorescent lamps).


Electromagnetic Fields , Environmental Exposure/analysis , Occupational Exposure/analysis , Radiation Monitoring , Radiation Protection , Humans , Radiation Dosage
...