Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Type of study
Language
Publication year range
1.
Sensors (Basel) ; 24(18)2024 Sep 19.
Article in English | MEDLINE | ID: mdl-39338793

ABSTRACT

Real-time data transmission and reliable operation are essential for a tsunami monitoring system to provide effective data. In this study, a novel real-time tsunami monitoring system is designed based on a submersible mooring system. This system is equipped with a data acquisition and tsunami wave identification algorithm, which can collect the measured data of the pressure sensor and detect a tsunami wave in real time. It adopts the combination design of underwater inductive coupling transmission and a redundant BeiDou communication device on the water surface to ensure the reliability of real-time data transmission. Compared with traditional tsunami monitoring buoys, it has the advantages of reliable communication, good concealment, high security, and convenient deployment, recovery, and maintenance. The results of laboratory and sea tests show that the system has high reliability of data transmission, stable overall operation of the system, and good application prospects in the field of real-time tsunami monitoring and early warning.

2.
J Diabetes Investig ; 15(2): 197-207, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37822187

ABSTRACT

AIMS/INTRODUCTION: Thrombospondin-1 (TSP-1) participates in a series of physiological and pathological processes by binding to various receptors regulating cell proliferation, adhesion and apoptosis. Elevated circulating TSP-1 is linked with diabetic vascular complications (DVC). This study aimed to determine the relationship between circulating TSP-1 levels and DVC. MATERIALS AND METHODS: A comprehensive search of PubMed, Embase, Web of Science and CNKI databases was carried out. A meta-analysis was carried out to compare circulating TSP-1 levels between diabetes patients without vascular complications (DNVC), diabetes patients with DVC and non-diabetes patients. The correlation between TSP-1 and metabolic parameters was also analyzed. Subgroup analysis was carried out according to complication type, defined as diabetic retinopathy, diabetic nephropathy and diabetic cardiovascular disease (DCVD). RESULTS: A total of eight studies were included. Compared with non-diabetes patients, diabetic patients, including DNVC and DVC, had significantly higher circulating TSP-1 levels (standardized mean difference [SMD] 2.660, 95% CI 1.17-4.145, P = 0.000). DNVC had significantly higher circulating TSP-1 levels than non-diabetes patients (SMD 3.613, 95% CI 1.607-5.619, P = 0.000). DVC had significantly higher TSP-1 levels than DNVC (SMD 0.568, 95% CI 0.100-1.036, P = 0.017). TSP-1 was significantly positively correlated with fasting plasma glucose (overall Fisher's z = 0.696, 95% CI 0.559-0.833) and HbA1c (overall Fisher's z = 0.849, 95% CI 0.776-0.923). CONCLUSIONS: Elevated circulating TSP-1 levels are closely related to DVC, especially in diabetic nephropathy and diabetic cardiovascular disease. Circulating TSP-1 detection might be helpful in the timely diagnosis and treatment of DVC.


Subject(s)
Cardiovascular Diseases , Diabetes Mellitus , Diabetic Angiopathies , Diabetic Nephropathies , Diabetic Retinopathy , Humans , Diabetic Angiopathies/etiology , Diabetic Nephropathies/pathology , Diabetic Retinopathy/etiology , Thrombospondin 1/metabolism
3.
Diabetes Metab Syndr Obes ; 16: 1435-1447, 2023.
Article in English | MEDLINE | ID: mdl-37229351

ABSTRACT

Objective: In view of the high prevalence of osteoporosis in diabetic patients, this study aimed to investigate the correlation between TyG-BMI, which represents insulin resistance, and bone loss markers, which represent bone metabolism, in an attempt to provide new ideas for the early prevention and diagnosis of osteoporosis in patients with T2DM. Patients and Methods: A total of 1148 T2DM were enrolled. The clinical data and laboratory indicators of the patients were collected. TyG-BMI was calculated based on fasting blood glucose (FBG), triglycerides (TG), and body mass index (BMI) levels. Patients were divided into Q1-Q4 groups according to TyG-BMI quartiles. According to gender, two groups were divided into men and postmenopausal women. Subgroup analysis was performed according to age, course of disease, BMI, TG level and 25(OH)D3 level. The correlation between TyG-BMI and BTMs was investigated by correlation analysis and multiple linear regression analysis using SPSS25.0 statistical software. Results: 1. Compared with Q1 group, the proportion of OC, PINP and ß-CTX in Q2, Q3 and Q4 groups decreased significantly. 2. Correlation analysis and multiple linear regression analysis showed that TYG-BMI was negatively correlated with OC, PINP and ß-CTX in all patients and male patients. In postmenopausal women, TyG-BMI was negatively correlated with OC and ß-CTX, but not with PINP. 3. Subgroup analysis of male patients and postmenopausal female patients according to age, course of disease, BMI, TG and 25(OH)D3 showed that TyG-BMI had a stronger negative correlation with BTMs in male patients with age < 65, disease duration < 10, BMI≥24, TG < 1.7, and 25(OH)D3≥20. Conclusion: This study was the first to show an inverse association between TyG-BMI and BTMs in T2DM patients, suggesting that high TyG-BMI may be associated with impaired bone turnover.

4.
Chemistry ; 24(45): 11619-11626, 2018 Aug 09.
Article in English | MEDLINE | ID: mdl-30003616

ABSTRACT

Preparation of stable water-in-oil (W/O) high internal phase emulsion (HIPE) containing methyl methacrylate (MMA) monomer as oil phase is a difficult task due to the significant solubility of MMA in water. Here, for the first time a fluorinated di-block copolymer (FDBC) poly (2-dimethylamino)ethylmethacrylate-b-poly (trifluoroethyl methacrylate) (PDMAEMA-b-PTFEMA) is proposed to stabilize HIPEs of MMA without the use of any co-stabilizer or thickening agent. Fluorinated segments in FDBC anchored well at oil/water interface of HIPE, offering high hydrophobicity to the partially hydrophilic MMA monomer and in turn stabilization to MMA-HIPE. By using fluorinated di-block copolymer as stabilizer, highly stable HIPEs can be obtained. In addition, highly interconnected porous monoliths were obtained after free radical polymerization, which are highly desirable materials in various practical applications including tissue engineering scaffolds, separation science, bio-engineering and so on. The as-prepared MMA-HIPEs possess high thermal stability without phase separation. The textural characteristics of as-prepared composites, such as pore size and distribution, can be easily controlled by simply varying the amount of FDBC and/or dispersed phase fraction. Moreover, the influence of di-block concentration on water uptake (WU) capability of the prepared porous monoliths is explored.

5.
RSC Adv ; 8(15): 8355-8364, 2018 Feb 19.
Article in English | MEDLINE | ID: mdl-35542035

ABSTRACT

A facile preparation for a series of porous poly(2,2,2-trifluoroethylmethacrylate-divinylbenzene) P(TFEMA-DVB) foams is discussed in this paper. The foams have adjustable morphology utilizing a suitable commercial surfactant, Hypermer B246, as stabilizer, and were compared with traditional organic surfactants or macromolecular block-polymers. Combining the porous properties and advantages of fluorine atoms, this type of fluoropolymer exhibited superb chemical stability and hydrophobicity performances with high porosity. These porous fluoro-monoliths preserved their regular porous structure without any degradation after immersion into strong acidic or basic solution for three days, hence demonstrating an excellent potential to deal with environmental pollution caused by oil spillages in severe environments. The tunable morphology (open and closed pores) and pore sizes were achieved by investigating various parameters like surfactant concentration, amount of external crosslinker, and aqueous phase volume. Droplet sizes of HIPEs were characterized using an optical microscope under different experimental conditions. The influence of pore structure and surface properties of polyHIPE on water contact angle and oil adsorption capacity was also explored. The results indicated that the porous material has an excellent oleophilicity and hydrophobicity, with water contact angles (WCA) up to 146.4°. Additionally, the results presented a noticeable adsorption with a very fast rate towards organic oils from either a water surface or bottom with adsorption saturation achieved in about 120 s. The prepared polyHIPEs showed a good recycling ability; even after 10 adsorption-centrifugation experiments, the adsorption capacity was still more than 85%.

SELECTION OF CITATIONS
SEARCH DETAIL