1 - 20 de 25
1.
Front Cardiovasc Med ; 9: 869259, 2022.
Article En | MEDLINE | ID: mdl-35811698

Background: A clinical study comparing the hemodynamic outcomes of transcatheter mitral valve replacement (TMVR) with vs. without Laceration of the Anterior Mitral leaflet to Prevent Outflow Obstruction (LAMPOON) has never been designed nor conducted. Aims: To quantify the hemodynamic impact of LAMPOON in TMVR using patient-specific computational (in silico) models. Materials: Eight subjects from the LAMPOON investigational device exemption trial were included who had acceptable computed tomography (CT) data for analysis. All subjects were anticipated to be at prohibitive risk of left ventricular outflow tract (LVOT) obstruction from TMVR, and underwent successful LAMPOON immediately followed by TMVR. Using post-procedure CT scans, two 3D anatomical models were created for each subject: (1) TMVR with LAMPOON (performed procedure), and (2) TMVR without LAMPOON (virtual control). A validated computational fluid dynamics (CFD) paradigm was then used to simulate the hemodynamic outcomes for each condition. Results: LAMPOON exposed on average 2 ± 0.6 transcatheter valve cells (70 ± 20 mm2 total increase in outflow area) which provided an additional pathway for flow into the LVOT. As compared to TMVR without LAMPOON, TMVR with LAMPOON resulted in lower peak LVOT velocity, lower peak LVOT gradient, and higher peak LVOT effective orifice area by 0.4 ± 0.3 m/s (14 ± 7% improvement, p = 0.006), 7.6 ± 10.9 mmHg (31 ± 17% improvement, p = 0.01), and 0.2 ± 0.1 cm2 (17 ± 9% improvement, p = 0.002), respectively. Conclusion: This was the first study to permit a quantitative, patient-specific comparison of LVOT hemodynamics following TMVR with and without LAMPOON. The LAMPOON procedure achieved a critical increment in outflow area which was effective for improving LVOT hemodynamics, particularly for subjects with a small neo-left ventricular outflow tract (neo-LVOT).

2.
Materials (Basel) ; 15(9)2022 May 05.
Article En | MEDLINE | ID: mdl-35591636

This paper provides a review of engineering applications and computational methods used to analyze the dynamics of heart valve closures in healthy and diseased states. Computational methods are a cost-effective tool that can be used to evaluate the flow parameters of heart valves. Valve repair and replacement have long-term stability and biocompatibility issues, highlighting the need for a more robust method for resolving valvular disease. For example, while fluid-structure interaction analyses are still scarcely utilized to study aortic valves, computational fluid dynamics is used to assess the effect of different aortic valve morphologies on velocity profiles, flow patterns, helicity, wall shear stress, and oscillatory shear index in the thoracic aorta. It has been analyzed that computational flow dynamic analyses can be integrated with other methods to create a superior, more compatible method of understanding risk and compatibility.

3.
Ann Thorac Surg ; 114(3): 841-847, 2022 09.
Article En | MEDLINE | ID: mdl-35120878

BACKGROUND: Despite favorable short-term outcomes, Fontan palliation is associated with comorbidities and diminished quality of life (QOL) in the years after completion. We hypothesized that poor Fontan hemodynamics and ventricular function are associated with worse QOL. METHODS: This was a single-center study of Fontan survivors aged more than 12 years. Subjects completed a cardiac magnetic resonance scan and QOL questionnaire. Cardiac magnetic resonance-derived variables included Fontan geometry, and hemodynamics. Computational fluid dynamics simulations quantified power loss, pressure drop, and total cavopulmonary connection resistance across the Fontan. Quality of life was assessed by completion of the Pediatric Quality of Life Inventory. Longitudinal and cross-sectional comparisons were made between cardiac magnetic resonance and computational fluid dynamics parameters with patient-reported QOL. RESULTS: We studied 77 Fontan patients, median age 19.7 years (interquartile range, 17.1 to 23.6), median time from Fontan completion 16 years (interquartile range, 13 to 20). Longitudinal data were available for 48 patients; median time between cardiac magnetic resonance and QOL was 8.1 years (interquartile range, 7 to 9.4). Median patient-reported Pediatric Quality of Life Inventory total score was 80 (interquartile range, 67.4 to 88). Greater power loss and smaller left pulmonary artery diameter at baseline were associated with worse QOL at follow-up. Greater pressure drop was associated with worse QOL at the same time point. CONCLUSIONS: For Fontan survivors, measures of computational fluid dynamics hemodynamics and geometry are associated with worse QOL. Interventional strategies targeted at optimizing the Fontan may improve QOL.


Fontan Procedure , Heart Defects, Congenital , Adolescent , Adult , Child , Cross-Sectional Studies , Heart Defects, Congenital/surgery , Hemodynamics , Humans , Pulmonary Artery/surgery , Quality of Life , Young Adult
4.
Eur Heart J Cardiovasc Imaging ; 23(5): 650-662, 2022 04 18.
Article En | MEDLINE | ID: mdl-34009283

AIMS: To characterize the dynamic nature of the left ventricular outflow tract (LVOT) geometry and flow rate in patients following transcatheter mitral valve replacement (TMVR) with anterior leaflet laceration (LAMPOON) and derive insights to help guide future patient selection. METHODS AND RESULTS: Time-resolved LVOT geometry and haemodynamics were analysed with post-procedure computed tomography and echocardiography in subjects (N = 19) from the LAMPOON investigational device exemption trial. A novel post hoc definition for LVOT obstruction was employed to account for systolic flow rate and quality of life improvement [obstruction was defined as LVOT gradient >30 mmHg or LVOT effective orifice area (EOA) ≤1.15 cm2]. The neo-LVOT and skirt neo-LVOT were observed to vary substantially in area throughout systole (64 ± 27% and 25 ± 14% change in area, respectively). The peak systolic flow rate occurred most commonly just prior to mid-systole, while minimum neo-LVOT (and skirt neo-LVOT) area occurred most commonly in early-diastole. Subjects with LVOT obstruction (n = 5) had smaller skirt neo-LVOT values across systole. Optimal thresholds for skirt neo-LVOT area were phase-specific (260, 210, 200, and 180 mm2 for early-systole, peak flow, mid-systole, and end-systole, respectively). CONCLUSION: The LVOT geometry and flow rate exhibit dynamic characteristics following TMVR with LAMPOON. Subjects with LVOT obstruction had smaller skirt neo-LVOT areas across systole. The authors recommend the use of phase-specific threshold values for skirt neo-LVOT area to guide future patient selection for this procedure. LVOT EOA is a 'flow-independent' metric which has the potential to aid in characterizing LVOT obstruction severity.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Ventricular Outflow Obstruction , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Quality of Life , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery
6.
Cardiovasc Eng Technol ; 12(6): 618-630, 2021 12.
Article En | MEDLINE | ID: mdl-34114202

BACKGROUND: Cardiovascular simulations for patients with single ventricles undergoing the Fontan procedure can assess patient-specific hemodynamics, explore surgical advances, and develop personalized strategies for surgery and patient care. These simulations have not yet been broadly accepted as a routine clinical tool owing to a number of limitations. Numerous approaches have been explored to seek innovative solutions for improving methodologies and eliminating these limitations. PURPOSE: This article first reviews the current state of cardiovascular simulations of Fontan hemodynamics. Then, it will discuss the technical progress of Fontan simulations with the emphasis of its clinical impact, noting that substantial improvements have been made in the considerations of patient-specific anatomy, flow, and blood rheology. The article concludes with insights into potential future directions involving clinical validation, uncertainty quantification, and computational efficiency. The advancements in these aspects could promote the clinical usage of Fontan simulations, facilitating its integration into routine clinical practice.


Cardiovascular System , Fontan Procedure , Heart Defects, Congenital , Heart Defects, Congenital/surgery , Hemodynamics , Humans , Models, Cardiovascular
7.
Cardiovasc Eng Technol ; 12(6): 606-617, 2021 12.
Article En | MEDLINE | ID: mdl-33931807

PURPOSE: Surgical planning has shown great potential for optimizing outcomes for patients affected by single ventricle (SV) malformations. Phase-contrast magnetic resonance imaging (PC-MRI) is the routine technique used for flow acquisition in the surgical planning paradigm. However, PC-MRI may suffer from possible artifacts in certain cases; furthermore, this technology may not be readily available for patients in low and lower-middle-income countries. Therefore, this study aims to investigate the effectiveness of using Doppler echocardiography (echo-Doppler) for flow acquisitions of SV surgical planning. METHODS: This study included eight patients whose blood flow data was acquired by both PC-MRI and echo-Doppler. A virtual surgery platform was used to generate two surgical options for each patient: (1) a traditional Fontan conduit and (2) a Y-graft. Computational fluid dynamics (CFD) simulations were conducted using the two flow acquisitions to assess clinically relevant hemodynamic metrics: indexed power loss (iPL) and hepatic flow distribution (HFD). RESULTS: Differences exist in flow data acquired by PC-MRI and echo-Doppler, but no statistical significance was obtained. Flow fields, therefore, exhibit discrepancies between simulations using flow acquisitions by PC-MRI and echo-Doppler. In virtual surgery, the two surgical options were ranked based on these metrics. No difference was observed in the ranking of surgical options between using different flow acquisitions. CONCLUSION: Doppler echocardiography is an adequate alternative approach to acquire flow data for SV surgical planning. This finding encourages broader usage of SV surgical planning with echo-Doppler when MRI may present artifacts or is not available, especially in low and lower-middle-income countries.


Echocardiography, Doppler , Heart Defects, Congenital , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Hemodynamics , Humans , Magnetic Resonance Imaging
8.
Semin Thorac Cardiovasc Surg ; 33(3): 816-823, 2021.
Article En | MEDLINE | ID: mdl-33662555

This hemodynamic feasibility study examined total cavopulmonary connection (TCPC) designs connecting the extracardiac conduit to the anterior surface of pulmonary arteries (PAs) or superior vena cava (SVC) rather than to the inferior PA surface (traditional TCPC). The study involved twenty-five consecutive Fontan patients meeting inclusion criteria from a single institution. A virtual surgical platform mimicked the completed traditional TCPC and generated three anterior anastomosis designs: Anterior-PA, Middle-SVC, and SVC-Inn (Inn: innominate vein). Hemodynamic performance of anterior anastomosis designs was compared with the traditional TCPC regarding indexed power loss (iPL) and hepatic flow distribution (HFD). Compared to the traditional TCPC, the Anterior-PA design produces a similar iPL. The Middle-SVC design is also similar, though the iPL difference is positively correlated with the anastomosing height. The SVC-Inn design had significantly more iPL. The three anterior anastomosis designs did not have a significant difference in HFD (from traditional TCPC). Pulmonary flow distribution (PFD) has a stronger correlation with HFD from the anterior anastomosis designs than the traditional TCPC. This hemodynamic feasibility study examined anterior anastomosis, extracardiac TCPC designs that may offer surgeons clinical dexterity. The Anterior-PA design may be equivalent to the traditional TCPC. Fontan extracardiac conduit anastomosis just superior to the PAs (Middle-SVC) also preserves hemodynamic performance and avoids direct PA anastomosis. These designs could simplify surgical Fontan completion, and may particularly benefit patients requiring surgical dissection, having atypical PA orientation, or after PA stent angioplasty.


Fontan Procedure , Heart Defects, Congenital , Fontan Procedure/adverse effects , Heart Defects, Congenital/surgery , Hemodynamics , Humans , Lung , Pulmonary Artery/surgery , Vena Cava, Superior/surgery
9.
Ann Biomed Eng ; 49(6): 1449-1461, 2021 Jun.
Article En | MEDLINE | ID: mdl-33723704

In silico modeling has been proposed as a tool to simulate left ventricular (LV) outflow tract (LVOT) obstruction in patients undergoing transcatheter mitral valve replacement (TMVR). This study validated a simplified approach to simulate LV outflow hemodynamics in the setting of TMVR with anterior leaflet laceration, a clinical technique used to mitigate the risk of LVOT obstruction. Personalized, 3-dimensional computational fluid dynamics models were developed from computed tomography images of six patients who underwent TMVR with anterior leaflet laceration. LV outflow hemodynamics were simulated using the patient-specific anatomy and the peak systolic flow rate as boundary conditions. The peak outflow velocity, a clinically relevant hemodynamic metric, was extracted from each simulation (vsim-peak) and compared with the clinical measurement from Doppler echocardiography (vclin-peak) for validation. In silico models were successfully developed and implemented for all patients. The pre-processing time was 2 h per model and the simulation could be completed within 3 h. In three patients, the lacerated anterior leaflet exposed open cells of the transcatheter valve to flow. Good agreement was obtained between vsim-peak and vclin-peak (r = 0.97, p < 0.01) with average discrepancies of 5 ± 2% and 14 ± 1% for patients with exposed and unexposed cells of the transcatheter valve, respectively. The proposed in silico modeling paradigm therefore simulated LV outflow hemodynamics in a time-efficient manner and demonstrated good agreement with clinical measurements. Future studies should investigate the ability of this paradigm to support clinical applications.


Heart Valve Prosthesis Implantation , Heart Ventricles/physiopathology , Models, Cardiovascular , Patient-Specific Modeling , Ventricular Outflow Obstruction/physiopathology , Aged , Aged, 80 and over , Coronary Circulation , Female , Heart Valve Prosthesis , Hemodynamics , Humans , Hydrodynamics , Lacerations , Middle Aged , Mitral Valve/surgery , Reproducibility of Results
10.
Biology (Basel) ; 9(12)2020 Nov 24.
Article En | MEDLINE | ID: mdl-33255292

Total cavopulmonary connection (TCPC) hemodynamics has been hypothesized to be associated with long-term complications in single ventricle heart defect patients. Rigid wall assumption has been commonly used when evaluating TCPC hemodynamics using computational fluid dynamics (CFD) simulation. Previous study has evaluated impact of wall compliance on extra-cardiac TCPC hemodynamics using fluid-structure interaction (FSI) simulation. However, the impact of ignoring wall compliance on the presumably more compliant intra-atrial TCPC hemodynamics is not fully understood. To narrow this knowledge gap, this study aims to investigate impact of wall compliance on an intra-atrial TCPC hemodynamics. A patient-specific model of an intra-atrial TCPC is simulated with an FSI model. Patient-specific 3D TCPC anatomies were reconstructed from transverse cardiovascular magnetic resonance images. Patient-specific vessel flow rate from phase-contrast magnetic resonance imaging (MRI) at the Fontan pathway and the superior vena cava under resting condition were prescribed at the inlets. From the FSI simulation, the degree of wall deformation was compared with in vivo wall deformation from phase-contrast MRI data as validation of the FSI model. Then, TCPC flow structure, power loss and hepatic flow distribution (HFD) were compared between rigid wall and FSI simulation. There were differences in instantaneous pressure drop, power loss and HFD between rigid wall and FSI simulations, but no difference in the time-averaged quantities. The findings of this study support the use of a rigid wall assumption on evaluation of time-averaged intra-atrial TCPC hemodynamic metric under resting breath-held condition.

11.
Pediatr Cardiol ; 41(5): 1021-1030, 2020 Jun.
Article En | MEDLINE | ID: mdl-32377893

Apicocaval juxtaposition (ACJ) is a rare form of viscerocardiac malpositions in association with single-ventricle congenital heart defects. The Fontan surgery is the common palliation, and possible surgical options include ipsilateral, contralateral, and intra-atrial conduits. Concerns include lower hemodynamic performances or risks of conduit compression by the cardiac mass. This study investigates the hemodynamics and clinical outcomes of ACJ patients and potential surgical improvements. Ten consecutive ACJ patients were included, along with a reference cohort of ten non-ACJ patients. Magnetic resonance images were acquired at 6 ± 0.6 year follow-up for anatomical analysis and hemodynamic assessments using computational fluid dynamics. Metrics of interest are deformation index (DI), indexed power loss (iPL), and hepatic flow distribution (HFDoff). A "virtual" surgery was performed to explore potential hemodynamic improvements using a straightened conduit. DI for ACJ patients fell within the DI range of non-ACJ patients. Contralateral conduits had insignificantly higher iPL (0.070 [0.032,0.137]) than ipsilateral conduits (0.041 [0.013,0.095]) and non-ACJ conduits (0.034 [0.011,0.061]). HFDoff was similar for the ipsilateral (21 [12,35]), contralateral (26 [7,41]), and non-ACJ Fontan conduits (17 [0,48]). Virtual surgery demonstrated that a straightened conduit reduced HFDoff and iPL for the contralateral and ipsilateral conduits, potentially leading to improved clinical outcomes. In this limited sample, the hemodynamic performance of ACJ patients was not significantly different from their non-ACJ counterparts. The use of a straightened conduit option could potentially improve patient outcomes. Additionally, the fear of significant compression of conduits for ACJ patients was unsupported.


Fontan Procedure/methods , Heart Defects, Congenital/surgery , Adolescent , Case-Control Studies , Child , Female , Fontan Procedure/adverse effects , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/physiopathology , Heart Ventricles/abnormalities , Heart Ventricles/surgery , Hemodynamics , Humans , Magnetic Resonance Imaging , Male , Pulmonary Artery/pathology , Pulmonary Artery/surgery
12.
J Cardiovasc Transl Res ; 13(4): 640-647, 2020 08.
Article En | MEDLINE | ID: mdl-31732919

Fontan surgical planning ranks proposed surgical options according to their hemodynamics assessed by computational fluid dynamic (CFD) modeling. CFD commonly utilizes blood flow acquired under breath-holding (BH) conditions. Ignoring the free-breathing (FB) effect on blood flow waveforms may impact the ranking of surgical options. This study investigates such a potential impact by including ten Fontan patients who had blood flow acquisitions under both BH and FB conditions. A virtual surgery platform was used to generate two surgical options for each patient: (1) a traditional Fontan conduit and (2) a Y-graft. These options were ranked based on clinically relevant hemodynamic metrics: power loss (PL) and hepatic flow distribution (HFD). No difference was found in the ranking of options between using FB and BH flow acquisitions. The findings indicated that decision-making is not affected by the types of flow acquisition for Fontan surgical planning.


Clinical Decision-Making , Diagnosis, Computer-Assisted , Fontan Procedure , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Magnetic Resonance Imaging , Patient-Specific Modeling , Adolescent , Female , Fontan Procedure/adverse effects , Heart Defects, Congenital/physiopathology , Hemodynamics , Humans , Male , Patient Selection , Predictive Value of Tests , Proof of Concept Study , Reoperation , Respiratory Mechanics , Retrospective Studies , Young Adult
13.
Ann Thorac Surg ; 109(6): 1904-1911, 2020 06.
Article En | MEDLINE | ID: mdl-31734244

BACKGROUND: Liver fibrosis is a serious complication of single ventricle Fontan survivors. Its causes are of great interest, and potential solutions to halt or delay progression are needed. The purpose of this study is to investigate if prior hemodynamics and anatomy can predict liver fibrosis severity in these patients. METHODS: Twenty-one Fontan patients with cardiac magnetic resonance (CMR) data obtained greater than 1 year before liver biopsy data were included. Computational fluid dynamic simulations were performed to quantify total cavopulmonary connection (TCPC) flow dynamics using patient-specific anatomies and blood flow waveforms reconstructed from CMR data. Collagen deposition (a measure of liver fibrosis) was quantified by digital image analysis of Sirius red-stained slides. Statistical analyses were performed to investigate potential relationships between Fontan hemodynamics and liver fibrosis. RESULTS: With an average time of 6.7 ± 2.9 years (range, 2-11 years) between CMR and biopsy, TCPC resistance and left pulmonary artery stenosis showed significant, positive correlations with magnitude of liver fibrosis (r = 0.54, P = .026; and r = 0.55, P = .028, respectively). The change in inferior vena cava flow rate over time also showed a significant positive correlation with magnitude of liver fibrosis (r = 0.91, P = .001). CONCLUSIONS: TCPC resistance, left pulmonary artery stenosis, and increased inferior vena cava flow are positively associated with liver fibrosis after Fontan operation and hold promise as important predictors of hepatic decline. These findings encourage preprocedural planning and interventional strategies to improve TCPC performance and reduce vessel stenosis. Further investigation is warranted to design the ideal Fontan circulation and optimize flow dynamics to reduce the risk of liver fibrosis.


Fontan Procedure/adverse effects , Forecasting , Heart Defects, Congenital/diagnosis , Liver Cirrhosis/diagnosis , Liver/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Postoperative Complications , Adolescent , Biopsy , Child , Child, Preschool , Female , Follow-Up Studies , Heart Defects, Congenital/surgery , Humans , Liver Cirrhosis/etiology , Male , Preoperative Period , Young Adult
14.
J Thorac Cardiovasc Surg ; 157(3): 1146-1155, 2019 03.
Article En | MEDLINE | ID: mdl-31264966

OBJECTIVE: Fontan surgical planning is an image-based, collaborative effort, which is hypothesized to result in improved patient outcomes. A common motivation for Fontan surgical planning is the progression (or concern for progression) of pulmonary arteriovenous malformations. The purpose of this study was to evaluate the accuracy of surgical planning predictions, specifically hepatic flow distribution (HFD), a known factor in pulmonary arteriovenous malformation progression, and identify methodological improvements needed to increase prediction accuracy. METHODS: Twelve single-ventricle patients who were enrolled in a surgical planning protocol for Fontan surgery with pre- and postoperative cardiac imaging were included in this study. Computational fluid dynamics were used to compare HFD in the surgical planning prediction and actual postoperative conditions. RESULTS: Overall, HFD prediction error was 17 ± 13%. This error was similar between surgery types (15 ± 18% and 18 ± 10% for revisions vs Fontan completions respectively; P = .73), but was significantly lower (6 ± 7%; P = .05) for hepatic to azygous shunts. Y-grafts and extracardiac conduits showed a strong correlation between prediction error and discrepancies in graft insertion points (r = 0.99; P < .001). Improving postoperative anatomy prediction significantly reduced overall HFD prediction error to 9 ± 6% (P = .03). CONCLUSIONS: Although Fontan surgical planning can offer accurate HFD predictions for specific graft types, methodological improvements are needed to increase overall accuracy. Specifically, improving postoperative anatomy prediction was shown to be an important target for future work. Future efforts and refinements to the surgical planning process will benefit from an improved understanding of the current state and will rely heavily on increased follow-up data.


Clinical Decision-Making , Decision Support Techniques , Fontan Procedure , Heart Defects, Congenital/surgery , Liver Circulation , Magnetic Resonance Imaging , Patient-Specific Modeling , Adolescent , Child , Child, Preschool , Female , Follow-Up Studies , Fontan Procedure/adverse effects , Georgia , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/physiopathology , Humans , Hydrodynamics , Infant , Male , Models, Cardiovascular , Patient Selection , Philadelphia , Postoperative Complications/etiology , Predictive Value of Tests , Prospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Young Adult
15.
Ann Biomed Eng ; 47(11): 2258-2270, 2019 Nov.
Article En | MEDLINE | ID: mdl-31236791

Computational fluid dynamic (CFD) simulations are widely utilized to assess Fontan hemodynamics that are related to long-term complications. No previous studies have systemically investigated the effects of using different inlet velocity profiles in Fontan simulations. This study implements real, patient-specific velocity profiles for numerical assessment of Fontan hemodynamics using CFD simulations. Four additional, artificial velocity profiles were used for comparison: (1) flat, (2) parabolic, (3) Womersley, and (4) parabolic with inlet extensions [to develop flow before entering the total cavopulmonary connection (TCPC)]. The differences arising from the five velocity profiles, as well as discrepancies between the real and each of the artificial velocity profiles, were quantified by examining clinically important metrics in TCPC hemodynamics: power loss (PL), viscous dissipation rate (VDR), hepatic flow distribution, and regions of low wall shear stress. Statistically significant differences were observed in PL and VDR between simulations using real and flat velocity profiles, but differences between those using real velocity profiles and the other three artificial profiles did not reach statistical significance. These conclusions suggest that the artificial velocity profiles (2)-(4) are acceptable surrogates for real velocity profiles in Fontan simulations, but parabolic profiles are recommended because of their low computational demands and prevalent applicability.


Computer Simulation , Fontan Procedure , Hemodynamics , Models, Cardiovascular , Adolescent , Child , Female , Humans , Hydrodynamics , Male , Pulmonary Artery
16.
J Biomech ; 82: 87-95, 2019 01 03.
Article En | MEDLINE | ID: mdl-30414631

OBJECTIVE: Poor total cavopulmonary connection (TCPC) hemodynamics have been hypothesized to be associated with long-term complications in Fontan patients. Image-based Fontan surgical planning has shown great potential as a clinical tool because it can pre-operatively evaluate patient-specific hemodynamics. Current surgical planning paradigms commonly utilize cardiac-gated phase contrast magnetic resonance (MR) imaging to acquire vessel flows. These acquisitions are often taken under breath-held (BH) conditions and ignore the effect of respiration on blood flow waveforms. This study investigates the effect of respiration-driven flow waveforms on patient-specific hemodynamics using real-time MR acquisitions. METHODS: Patient-specific TCPCs were reconstructed from cardiovascular MR images. Real-time phase contrast MR images were acquired under both free-breathing (FB) and breath-held conditions for 9 patients. Numerical simulations were employed to assess flow structures and hemodynamics used in Fontan surgical planning including hepatic flow distribution (HFD) and indexed power loss (iPL), which were then compared between FB and BH conditions. RESULTS: Differences in TCPC flow structures between FB and BH conditions were observed throughout the respiratory cycle. However, the average differences (BH - FB values for each patient, which are then averaged) in iPL and HFD between these conditions were 0.002 ±â€¯0.011 (p = 0.40) and 1 ±â€¯3% (p = 0.28), respectively, indicating no significant difference in clinically important hemodynamic metrics. CONCLUSIONS: Respiration affects blood flow waveforms and flow structures, but might not significantly influence the values of iPL or HFD. Therefore, breath-held MR acquisition can be adequate for Fontan surgical planning when focusing on iPL and HFD.


Fontan Procedure/methods , Hemodynamics , Respiration , Adolescent , Adult , Female , Humans , Magnetic Resonance Imaging , Male , Models, Cardiovascular , Young Adult
17.
Curr Treat Options Cardiovasc Med ; 20(12): 99, 2018 Oct 26.
Article En | MEDLINE | ID: mdl-30367270

PURPOSE OF REVIEW: Transcatheter mitral valve replacement (TMVR) is an emerging alternative for patients with severe mitral valve regurgitation who are considered at high risk for conventional surgical options. The early clinical experience with TMVR has shown that pre-procedural planning with computed tomography (CT) is needed to mitigate the risk of potentially lethal procedural complications such as left ventricular outflow tract (LVOT) obstruction. The goal of this review is to provide an overview of key concepts relating to TMVR pre-procedural planning, with particular emphasis on imaging-based methods for predicting TMVR-related LVOT obstruction. RECENT FINDINGS: Risk of LVOT obstruction can be assessed with CT-based pre-procedural planning by using virtual device simulations to estimate the residual 'neo-LVOT' cross-sectional area which remains after device implantation. A neo-LVOT area of less than 2 cm2 is currently thought to increase the risk of obstruction; however, additional studies are needed to further validate this cutoff value. Three-dimensional printing and personalized computational simulations are also emerging as valuable tools which may offer insights not readily confered by conventional two-dimensional image analysis. The simulated neo-LVOT should be routinely assessed on pre-procedural CT when evaluating anatomical suitability for TMVR.

18.
Cardiovasc Eng Technol ; 9(3): 289-299, 2018 09.
Article En | MEDLINE | ID: mdl-29675697

The governing international standard for the development of prosthetic heart valves is International Organization for Standardization (ISO) 5840. This standard requires the assessment of the thrombus potential of transcatheter heart valve substitutes using an integrated thrombus evaluation. Besides experimental flow field assessment and ex vivo flow testing, computational fluid dynamics is a critical component of this integrated approach. This position paper is intended to provide and discuss best practices for the setup of a computational model, numerical solving, post-processing, data evaluation and reporting, as it relates to transcatheter heart valve substitutes. This paper is not intended to be a review of current computational technology; instead, it represents the position of the ISO working group consisting of experts from academia and industry with regards to considerations for computational fluid dynamic assessment of transcatheter heart valve substitutes.


Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Hemodynamics , Materials Testing/methods , Models, Cardiovascular , Animals , Benchmarking , Blood Flow Velocity , Computer Simulation , Heart Valve Prosthesis/standards , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/standards , Humans , Hydrodynamics , Materials Testing/standards , Prosthesis Design , Risk Assessment , Risk Factors , Stress, Mechanical , Thrombosis/blood , Thrombosis/etiology , Thrombosis/physiopathology
19.
J Cardiovasc Transl Res ; 11(2): 133-144, 2018 04.
Article En | MEDLINE | ID: mdl-29340873

The ultimate goal of Fontan surgical planning is to provide additional insights into the clinical decision-making process. In its current state, surgical planning offers an accurate hemodynamic assessment of the pre-operative condition, provides anatomical constraints for potential surgical options, and produces decent post-operative predictions if boundary conditions are similar enough between the pre-operative and post-operative states. Moving forward, validation with post-operative data is a necessary step in order to assess the accuracy of surgical planning and determine which methodological improvements are needed. Future efforts to automate the surgical planning process will reduce the individual expertise needed and encourage use in the clinic by clinicians. As post-operative physiologic predictions improve, Fontan surgical planning will become an more effective tool to accurately model patient-specific hemodynamics.


Fontan Procedure/methods , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Models, Cardiovascular , Patient-Specific Modeling , Surgery, Computer-Assisted/methods , Clinical Decision-Making , Fontan Procedure/adverse effects , Heart Defects, Congenital/pathology , Heart Defects, Congenital/physiopathology , Hemodynamics , Humans , Patient Selection , Patient-Centered Care/methods , Surgery, Computer-Assisted/adverse effects , Time-to-Treatment , Ventricular Function
20.
Ann Biomed Eng ; 46(3): 404-416, 2018 Mar.
Article En | MEDLINE | ID: mdl-29094292

Flow efficiency through the Fontan connection is an important factor related to patient outcomes. It can be quantified using either a simplified power loss or a viscous dissipation rate metric. Though practically equivalent in simplified Fontan circulation models, these metrics are not identical. Investigation is needed to evaluate the advantages and disadvantages of these metrics for their use in in vivo or more physiologically-accurate Fontan modeling. Thus, simplified power loss and viscous dissipation rate are compared theoretically, computationally, and statistically in this study. Theoretical analysis was employed to assess the assumptions made for each metric and its clinical calculability. Computational simulations were then performed to obtain these two metrics. The results showed that apparent simplified power loss was always greater than the viscous dissipation rate for each patient. This discrepancy can be attributed to the assumptions derived in theoretical analysis. Their effects were also deliberately quantified in this study. Furthermore, statistical analysis was conducted to assess the correlation between the two metrics. Viscous dissipation rate and its indexed quantity show significant, strong, linear correlation to simplified power loss and its indexed quantity (p < 0.001, r > 0.99) under certain assumptions. In conclusion, viscous dissipation rate was found to be more advantageous than simplified power loss as a hemodynamic metric because of its lack of limiting assumptions and calculability in the clinic. Moreover, in addition to providing a time-averaged bulk measurement like simplified power loss, viscous dissipation rate has spatial distribution contours and time-resolved values that may provide additional clinical insight. Finally, viscous dissipation rate could maintain the relationship between Fontan connection flow efficiency and patient outcomes found in previous studies. Consequently, future Fontan hemodynamic studies should calculate both simplified power loss and viscous dissipation rate to maintain ties to previous studies, but also provide the most accurate measure of flow efficiency. Additional attention should be paid to the assumptions required for each metric.


Blood Viscosity , Models, Cardiovascular , Blood Flow Velocity , Female , Humans , Male
...