1.
Comput Methods Programs Biomed ; 250: 108186, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38692252

ABSTRACT

BACKGROUND AND OBJECTIVES: Venovenous Extracorporeal Membrane Oxygenation (VV ECMO) provides respiratory support to patients with severe lung disease failing conventional medical therapy. An essential component of the ECMO circuit are the cannulas, which drain and return blood into the body. Despite being anchored to the patient to prevent accidental removal, minor cannula movements are common during ECMO. The clinical and haemodynamic consequences of these small movements are currently unclear. This study investigated the risk of thrombosis and recirculation caused by small movements of a dual lumen cannula (DLC) in an adult using computational fluid dynamics. METHODS: The 3D model of an AVALON Elite DLC (27 Fr) and a patient-specific vena cava and right atrium were generated for an adult patient on ECMO. The baseline cannula position was generated where the return jet enters the tricuspid valve. Alternative cannula positions were obtained by shifting the cannula 5 and 15 mm towards inferior (IVC) and superior (SVC) vena cava, respectively. ECMO settings of 4 L/min blood flow and pulsatile flow at SVC and IVC were applied. Recirculation was defined as a scalar value indicating the infused oxygenated blood inside the drainage lumen, while thrombosis risk was evaluated by shear stress, stagnation volume, washout, and turbulent kinetic energy. RESULTS: Recirculation for all models was less than 3.1 %. DLC movements between -5 to 15 mm increased shear stress and turbulence kinetic energy up to 24.7 % and 11.8 %, respectively, compared to the baseline cannula position leading to a higher predicted thrombosis risk. All models obtained a complete washout after nine seconds except for when the cannula migrated 15 mm into the SVC, indicating persisting stasis and circulating zones. CONCLUSION: In conclusion, small DLC movements were not associated with an increased risk of recirculation. However, they may increase the risk of thrombosis due to increased shear rate, turbulence, and slower washout of blood. Developing effective cannula securement devices may reduce this risk.


Subject(s)
Cannula , Extracorporeal Membrane Oxygenation , Hydrodynamics , Extracorporeal Membrane Oxygenation/instrumentation , Humans , Thrombosis/etiology , Thrombosis/prevention & control , Computer Simulation , Adult , Hemodynamics , Models, Cardiovascular
2.
Perfusion ; : 2676591241256502, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38783767

ABSTRACT

BACKGROUND: Large cannulae can increase cannula-related complications during venoarterial extracorporeal membrane oxygenation (VA ECMO). Conversely, the ability for small cannulae to provide adequate support is poorly understood. Therefore, we aimed to evaluate a range of cannula sizes and VA ECMO flow rates in a simulated patient under various disease states. METHODS: Arterial cannulae sizes between 13 and 21 Fr and drainage cannula sizes between 21 and 25 Fr were tested in a VA ECMO circuit connected to a mock circulation loop simulating a patient with severe left ventricular failure. Systemic and pulmonary hypertension, physiologically normal, and hypotension were simulated by varying systemic and pulmonary vascular resistances (SVR and PVR, respectively). All cannula combinations were evaluated against all combinations of SVR, PVR, and VA ECMO flow rates. RESULTS: A 15 Fr arterial cannula combined with a 21 Fr drainage cannula could provide >4 L/min of total flow and a mean arterial pressure of 81.1 mmHg. Changes in SVR produced marked changes to all measured parameters, while changes to PVR had minimal effect. Larger drainage cannulae only increased maximum circuit flow rates when combined with larger arterial cannulae. CONCLUSION: Smaller cannulae and lower flow rates could sufficiently support the simulated patient under various disease states. We found arterial cannula size and SVR to be key factors in determining the flow-delivering capabilities for any given VA ECMO circuit. Overall, our results challenge the notion that larger cannulae and high flows must be used to achieve adequate ECMO support.

3.
Comput Biol Med ; 172: 108263, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38489988

ABSTRACT

PROBLEM: Despite advances in Venoarterial Extracorporeal Membrane Oxygenation (VA-ECMO), a significant mortality rate persists due to complications. The non-physiological blood flow dynamics of VA-ECMO may lead to neurological complications and organ ischemia. Continuous retrograde high-flow oxygenated blood enters through a return cannula placed in the femoral artery which opposes the pulsatile deoxygenated blood ejected by the left ventricle (LV), which impacts upper body oxygenation and subsequent hyperoxemia. The complications underscore the critical need to comprehend the impact of VA-ECMO support level and return cannula size, as mortality remains a significant concern. AIM: The aim of this study is to predict and provide insights into the complications associated with VA-ECMO using computational fluid dynamics (CFD) simulations. These complications will be assessed by characterising blood flow and emboli transport patterns through a comprehensive analysis of the influence of VA-ECMO support levels and arterial return cannula sizes. METHODS: Patient-specific 3D aortic and major branch models, derived from a male patient's CT scan during VA-ECMO undergoing respiratory dysfunction, were analyzed using CFD. The investigation employed species transport and discrete particle tracking models to study ECMO blood (oxygenated) mixing with LV blood (deoxygenated) and to trace emboli transport patterns from potential sources (circuit, LV, and aorta wall). Two cannula sizes (15 Fr and 19 Fr) were tested alongside varying ECMO pump flow rates (50%, 70%, and 90% of the total cardiac output). RESULTS: Cannula size did not significantly affect oxygen transport. At 90% VA-ECMO support, all arteries distal to the aortic arch achieved 100% oxygen saturation. As support level decreased, oxygen transport to the upper body also decreased to a minimum saturation of 73%. Emboli transport varied substantially between emboli origin and VAECMO support level, with the highest risk of cerebral emboli coming from the LV with a 15 Fr cannula at 90% support. CONCLUSION: Arterial return cannula sizing minimally impacted blood oxygen distribution; however, it did influence the distribution of emboli released from the circuit and aortic wall. Notably, it was the support level alone that significantly affected the mixing zone of VA-ECMO and cardiac blood, subsequently influencing the risk of embolization of the cardiogenic source and oxygenation levels across various arterial branches.


Subject(s)
Extracorporeal Membrane Oxygenation , Male , Humans , Hydrodynamics , Hemodynamics/physiology , Catheterization , Oxygen
4.
Comput Biol Med ; 171: 108135, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38373368

ABSTRACT

BACKGROUND: Drainage cannulae extract blood from a patient during venoarterial extracorporeal membrane oxygenation (VA ECMO), a treatment that temporarily supports patients undergoing severe heart and/or lung dysfunction. Currently, the two most commonly used multi-stage drainage cannulae are manufactured by Maquet and Bio-Medicus, but their designs vary in many aspects which impacts the generated flow dynamics. Therefore, this study aimed to use computational fluid dynamics (CFD) to explore the flow characteristics of the aforementioned cannulae and their impact on complications such as thrombosis. METHODS: The Maquet and Bio-Medicus cannulae were 3D modelled within a patient-specific geometry of the venous vasculature taken from a computed tomography scan of a patient undergoing VA ECMO. A drainage flow rate of 4 L/min was assigned to each cannula. Lastly, a stress blended eddy simulation turbulence model was employed to resolve bulk flow turbulence. RESULTS: The proximal row of side holes in both cannulae generated high intensity counter-rotating vortices, thus generating supraphysiological shear. These proximal rows were also responsible for the majority of flow extraction in both cannulae (>1.6 L/min). Despite identical simulation settings, each cannulae had differing impacts on global flow dynamics. For instance, the Bio-Medicus model produced a total stagnant blood volume of 25.6 ml, compared to 17.8 ml the Maquet cannula, thereby increasing the risk of thrombosis. CONCLUSIONS: Overall, our results demonstrate that differences in design clearly impact flow dynamics and risk of complications. Therefore, further work in optimizing cannula design may be beneficial to prevent harmful flow characteristics.


Subject(s)
Extracorporeal Membrane Oxygenation , Thrombosis , Humans , Cannula , Extracorporeal Membrane Oxygenation/methods , Hemodynamics/physiology , Heart , Thrombosis/diagnostic imaging
5.
ASAIO J ; 69(11): 1004-1008, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37549666

ABSTRACT

The aim of this study was to explore the association between arterial return cannula diameter and hemolysis during peripheral VA ECMO. We identified 158 adult patients who received peripheral VA ECMO at our institution from the national ECMO database (EXCEL) between January 2019 and July 2021. We classified patients into a small cannula group (15 Fr diameter, n = 45) and a large cannula group (≥17 Fr diameter, n = 113), comparing incidences of clinical hemolysis and plasma free hemoglobin ( pf Hb). Moderate hemolysis is defined as having pf Hb 0.05-0.10 g/L and severe hemolysis as having pf Hb >0.10 g/L sustained for at least two consecutive readings or leading to a circuit change. There were no significant differences in rates of moderate hemolysis between small and large cannula groups (1 vs . 6; p = 0.39) and severe hemolysis (0 vs . 3; p = 0.27), nor was the pf Hb level significantly different at 4 hours (0.086 ± 0.096 vs . 0.112 ± 0.145 g/L; p = 0.58) and at 24 hours (0.042 ± 0.033 vs . 0.051 ± 0.069 g/L; p = 0.99). There were no increased rates of hemolysis when comparing small versus large arterial return cannula diameter in peripheral VA ECMO.


Subject(s)
Cannula , Extracorporeal Membrane Oxygenation , Adult , Humans , Cohort Studies , Cannula/adverse effects , Extracorporeal Membrane Oxygenation/adverse effects , Hemolysis , Catheterization
6.
Comput Methods Programs Biomed ; 231: 107407, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36764061

ABSTRACT

BACKGROUND AND OBJECTIVES: Venoarterial extracorporeal membrane oxygenation (VA ECMO) is able to support critically ill patients undergoing refractory cardiopulmonary failure. It relies on drainage cannulae to extract venous blood from the patient, but cannula features and tip position may impact flow dynamics and thrombosis risk. Therefore, this study aimed to investigate the effect of tip position of single-stage (SS) and multi-stage (MS) VA ECMO drainage cannulae on the risk of thrombosis. METHODS: Computational fluid dynamics was used to model flow dynamics within patient-specific geometry of the venous vasculature. The tip of the SS and MS cannula was placed in the superior vena cava (SVC), SVC-Right atrium (RA) junction, mid-RA, inferior vena cava (IVC)-RA junction, and IVC. The risk of thrombosis was assessed by measuring several factors. Blood residence time was measured via an Eulerian approach through the use of a scalar source term. Regions of stagnant volume were recognised by identifying regions of low fluid velocity and shear rate. Rate of blood washout was calculated by patching the domain with a scalar value and measuring the rate of fluid displacement. Lastly, wall shear stress values were determined to provide a qualitative understanding of potential blood trauma. RESULTS: Thrombosis risk varied substantially with position changes of the SS cannula, which was less evident with the MS cannula. The SS cannula showed reduced thrombosis risk arising from stagnant regions when placed in the SVC or SVC-RA junction, whereas an MS cannula was predicted to create stagnant regions during all tip positions. When positioned in the IVC-RA junction or IVC, the risk of thrombosis was higher in the SS cannula than in the MS cannula due to both high and low shear flow. CONCLUSION: Tip position of the drainage cannula impacts cannula flow dynamics and, subsequently, the risk of thrombosis. The use of MS cannulae can reduce high shear-related thrombosis, but SS cannulae can eliminate stagnant regions when advanced into the SVC. Therefore, the choice of cannula design and tip position should be carefully considered during cannulation.


Subject(s)
Extracorporeal Membrane Oxygenation , Thrombosis , Humans , Cannula , Vena Cava, Superior , Drainage
7.
Phys Eng Sci Med ; 46(1): 119-129, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36459331

ABSTRACT

Interaction between native ventricular output and venoarterial extracorporeal membrane oxygenation (VA ECMO) flow may hinder oxygenated blood flow to the aortic arch branches, resulting in differential hypoxemia. Typically, the arterial cannula tip is placed in the iliac artery or abdominal aorta. However, the hemodynamics of a more proximal arterial cannula tip have not been studied before. This study investigated the effect of arterial cannula tip position on VA ECMO blood flow to the upper extremities using computational fluid dynamics simulations. Four arterial cannula tip positions (P1. common iliac, P2. abdominal aorta, P3. descending aorta and P4. aortic arch) were compared with different degrees of cardiac dysfunction and VA ECMO support (50%, 80% and 90% support). P4 was able to supply oxygenated blood to the arch vessels at all support levels, while P1 to P3 only supplied the arch vessels during the highest level (90%) of VA ECMO support. Even during the highest level of support, P1 to P3 could only provide oxygenated VA-ECMO flow at 0.11 L/min to the brachiocephalic artery, compared with 0.5 L/min at P4. This study suggests that cerebral perfusion of VA ECMO flow can be increased by advancing the arterial cannula tip towards the aortic arch.


Subject(s)
Extracorporeal Membrane Oxygenation , Humans , Extracorporeal Membrane Oxygenation/methods , Cannula , Catheterization/methods , Hypoxia/therapy , Aorta, Thoracic
8.
Artif Organs ; 46(6): 1068-1076, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35049072

ABSTRACT

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (ECMO) provides mechanical support for critically ill patients with cardiogenic shock. Typically, the size of the arterial return cannula is chosen to maximize flow. However, smaller arterial cannulae may reduce cannula-related complications and be easier to insert. This in vitro study quantified the hemodynamic effect of different arterial return cannula sizes in a simulated acute heart failure patient. METHODS: Baseline support levels were simulated with a 17 Fr arterial cannula in an ECMO circuit attached to a cardiovascular simulator with targeted partial (2.0 L/min ECMO flow, 60-65 mm Hg mean aortic pressure-MAP) and targeted full ECMO support (3.5 L/min ECMO flow and 70-75 mm Hg MAP). Return cannula size was varied (13-21 Fr), and hemodynamics were recorded while keeping ECMO pump speed constant and adjusting pump speed to restore desired support levels. RESULTS: Minimal differences in hemodynamics were found between cannula sizes in partial support mode. A maximum pump speed change of +600 rpm was required to reach the support target, and arterial cannula inlet pressure varied from 79 (21 Fr) to 224 mm Hg (13 Fr). The 15 Fr arterial cannula could provide the target full ECMO support at the targeted hemodynamics; however, the 13 Fr cannula could not due to the high resistance associated with the small diameter. CONCLUSIONS: A 15 Fr arterial return cannula provided targeted partial and full ECMO support to a simulated acute heart failure patient. Balancing reduced cannula size and ECMO support level may improve patient outcomes by reducing cannula-related adverse events.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure , Cannula/adverse effects , Extracorporeal Membrane Oxygenation/adverse effects , Heart Failure/etiology , Heart Failure/therapy , Hemodynamics , Humans , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy