Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Neurosurg Focus ; 57(3): E4, 2024 09 01.
Article in English | MEDLINE | ID: mdl-39217631

ABSTRACT

OBJECTIVE: MR-guided focused ultrasound (MRgFUS) thalamotomy is an incisionless neurosurgical treatment for patients with medically refractory essential tremor and tremor-dominant Parkinson's disease. A low skull density ratio (SDR) < 0.40 is a known risk factor for treatment failure. The aim of this study was to identify useful sonication strategies for patients with a low SDR < 0.40 by modifying the standard sonication protocol using maximum high-energy sonication while minimizing the number of sonications. METHODS: The authors retrospectively analyzed the effects of modified MRgFUS sonication on low-SDR tremor patients. All patients underwent head CT scans to calculate their SDR. The SDR threshold for MRgFUS thalamotomy was 0.35. The patients in the early series underwent the standard sonication protocol targeting the ventral intermediate nucleus contralateral to the treated hand side. The patients with a low SDR < 0.40 in the late series underwent a modified sonication protocol, in which the number of alignment sonications was minimized and high-energy treatment sonication (> 36,000 J) was used. The authors evaluated the lesion volume the following day and tremor improvement and adverse events 3 and 12 months after the procedure. The sonication patterns between low-SDR patients treated using different sonication protocols were examined using Fisher's exact test. ANOVA was used to examine the lesion volume and tremor improvement in high- and low-SDR patients treated using different sonication protocols. RESULTS: Among 41 patients with an SDR < 0.40, 14 underwent standard sonication and 27 underwent modified sonication. Fewer alignment sonications and high-energy treatment sonications were used in the modified sonication group compared with the standard group (p < 0.001). The duration of modified sonication was significantly shorter than that of standard sonication (p < 0.001). The lesion volume and tremor improvement significantly differed among the high- and low-SDR groups with different sonication protocols (p < 0.001). Low-SDR patients treated using modified sonication protocols had comparable lesion volume and tremor improvement to the high-SDR group. The modified sonication protocol did not significantly increase adverse intraprocedural and postprocedural events. CONCLUSIONS: Minimizing alignment sonications and applying high-energy sonication in early treatment help to create an optimal lesion volume and control tremor in low-SDR patients.


Subject(s)
Essential Tremor , Parkinson Disease , Thalamus , Humans , Essential Tremor/surgery , Essential Tremor/diagnostic imaging , Parkinson Disease/surgery , Parkinson Disease/diagnostic imaging , Parkinson Disease/therapy , Female , Male , Aged , Middle Aged , Retrospective Studies , Thalamus/surgery , Thalamus/diagnostic imaging , Skull/surgery , Skull/diagnostic imaging , Magnetic Resonance Imaging/methods , Treatment Outcome , Aged, 80 and over , High-Intensity Focused Ultrasound Ablation/methods , Sonication/methods , Neurosurgical Procedures/methods
2.
Surg Neurol Int ; 15: 271, 2024.
Article in English | MEDLINE | ID: mdl-39246795

ABSTRACT

Background: Head-mounted display (HMD) arises as an alternative display system for surgery. This study aimed to assess the utility of a stereoscopic HMD for exoscopic neurosurgery. Methods: The leading operator and assistants were asked to assess the various aspects of the HMD characteristics compared to the monitor display using a visual analog scale (VAS)-based questionnaire. The VAS score ranged from 0 to 10 (0, HMD was significantly inferior to the monitor; 5, HMD and monitor display were equal; and 10, HMD was significantly superior to the monitor). Results: The surgeons and assistants used and evaluated HMD in seven exoscopic surgeries: three tumor removal, one aneurysm clipping, one anterior cervical discectomy and fusion, and two cervical laminectomy surgeries. The leading operators' assessment of HMD-based surgery was not different from monitor-based surgery; however, the assistants evaluated the field of view, overall image quality, and the assisting procedure as better in MHD-based surgery than monitor-based surgery (P = 0.039, 0.045, and 0.013, respectively). Conclusion: HMD-based exoscopic neurosurgery can be performed at a similar quality as monitor-based surgery. Surgical assistants may benefit from using HMD-based surgery.

3.
J Neurosurg Case Lessons ; 8(7)2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39133947

ABSTRACT

BACKGROUND: Bow hunter's stroke (BHS) is a rare condition characterized by occlusion of the vertebral artery (VA) due to a head rotation. BHS typically results from neck hyperrotation, often due to anatomical factors. The authors present a case of BHS in a young male patient exacerbated by os odontoideum (OD), resulting in atlantoaxial dislocation, which ultimately led to VA dissection. OBSERVATIONS: A man in his 20s presented with persistent dizziness and nausea and initially received a diagnosis of a brain infarction. However, imaging revealed VA dissection caused by an OD with an associated synovial cyst. Surgical intervention, specifically atlantoaxial posterior fixation, resolved the instability and allowed for natural regression of the synovial cysts, preventing further vascular events. In this case, the OD with atlantoaxial dislocation was identified as the causative factor for BHS. The coexistence of a synovial cyst was a unique finding, likely triggered by chronic irritation caused by the OD. LESSONS: This case emphasizes the importance of thorough cervical spinal evaluation in young patients presenting with posterior circulation stroke. https://thejns.org/doi/10.3171/CASE2487.

SELECTION OF CITATIONS
SEARCH DETAIL