Diagnostics (Basel) ; 14(4)2024 Feb 11.
Article in English | MEDLINE | ID: mdl-38396433

ABSTRACT

Despite numerous attempts to correct forward head posture (FHP), definitive evidence-based screening and diagnostic methods remain elusive. This study proposes a preliminary diagnostic methodology for FHP, utilizing a noninvasive body angle measurement system as a screening test for FHP and incorporating radiological parameters for sagittal alignment. We enrolled 145 adolescents for FHP screening. The forward neck tilt angle (FNTA), defined as the angle between the vertical line and the line connecting the participant's acromion and tragus, was measured using the POM-Checker (a noninvasive depth sensor-based body angle measurement system). A whole-spine standing lateral radiograph was obtained, and eight sagittal alignment parameters were measured. Statistical analyses of the association between the FNTA and eight sagittal alignment parameters were conducted. We used 70% of the participant data to establish a preliminary diagnostic model for FHP based on FNTA and each sagittal alignment parameter. The accuracy of the model was evaluated using the remaining 30% of the participant data. All radiological parameters of sagittal alignment showed weak statistical significance with respect to FNTA (best case: r = 0.16, p = 0.0500; cranial tilt). The proposed preliminary diagnostic model for FHP demonstrated 95.35% agreement. Notably, the model using FNTA without radiological parameters accurately identified (100%) participants who required radiographic scanning for FHP diagnosis. Owing to the weak statistical significance of the association between radiological parameters and external body angle, both factors must be considered for accurate FHP diagnosis. When a clear and severe angle variation is observed in an external body angle check, medical professionals should perform radiographic scanning for an accurate FHP diagnosis. In conclusion, FNTA assessment of FNTA through the proposed preliminary diagnostic model is a significant screening factor for selecting participants who must undergo radiographic scanning so that a diagnosis of FHP can be obtained.

3.
Sci Rep ; 13(1): 20431, 2023 11 22.
Article in English | MEDLINE | ID: mdl-37993627

ABSTRACT

Orthopaedic surgeons need to correctly identify bone fragments using 2D/3D CT images before trauma surgery. Advances in deep learning technology provide good insights into trauma surgery over manual diagnosis. This study demonstrates the application of the DeepLab v3+ -based deep learning model for the automatic segmentation of fragments of the fractured tibia and fibula from CT images and the results of the evaluation of the performance of the automatic segmentation. The deep learning model, which was trained using over 11 million images, showed good performance with a global accuracy of 98.92%, a weighted intersection over the union of 0.9841, and a mean boundary F1 score of 0.8921. Moreover, deep learning performed 5-8 times faster than the experts' recognition performed manually, which is comparatively inefficient, with almost the same significance. This study will play an important role in preoperative surgical planning for trauma surgery with convenience and speed.


Subject(s)
Deep Learning , Tomography, X-Ray Computed , Tomography, X-Ray Computed/methods , Fibula/diagnostic imaging , Tibia/diagnostic imaging , Imaging, Three-Dimensional/methods , Image Processing, Computer-Assisted/methods
4.
Sci Rep ; 13(1): 10542, 2023 06 29.
Article in English | MEDLINE | ID: mdl-37386116

ABSTRACT

Pelvic bone fracture is highly complex, and its anatomical reduction is difficult. Therefore, patient-specific customized plates have been developed using three-dimensional (3D) printing technology and are being increasingly used. In this study, the reduction status in five representative pelvic fracture models was compared between two groups: the 3D printing plate (3DP) group using a patient-specific 3D printed plate after virtual reduction and the conventional plate (CP) group using a conventional plate by manual bending. The 3DP and CP groups included 10 and 5 cases, respectively. The fractured models were reduced virtually and their non-locking metal plates were customized using 3D printing. The process of contouring the conventional plates to fit the contact surface of the bone with the bending tool was conducted by an experienced pelvic bone trauma surgeon. The reduction and fixation achieved using the two different plate groups was compared, and the significance of differences in the results was analyzed using paired t-tests, after verifying the normality of data distribution. The vertex distances between the surface of the bone and the contact surface of the plate were significantly lower in the 3DP group than in the CP group (0.407 ± 0.342 and 2.195 ± 1.643, respectively, P = 0.008). Length and angular variations, which are measurements of the reduction state, were also lower in the 3DP group than in the CP group (length variation: 3.211 ± 2.497 and 5.493 ± 3.609, respectively, P = 0.051; angular variation: 2.958 ± 1.977 and 4.352 ± 1.947, respectively, P = 0.037). The customized 3D printed plate in the virtual reduction model provided a highly accurate reduction of pelvic bone fractures, suggesting that the customized 3D printed plate may help ensure easy and accurate reduction.


Subject(s)
Fractures, Bone , Pelvic Bones , Plastic Surgery Procedures , Humans , Psychotherapy , Bone Plates , Fractures, Bone/surgery , Printing, Three-Dimensional
5.
Diagnostics (Basel) ; 14(1)2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38201320

ABSTRACT

Utilizing "You only look once" (YOLO) v4 AI offers valuable support in fracture detection and diagnostic decision-making. The purpose of this study was to help doctors to detect and diagnose fractures more accurately and intuitively, with fewer errors. The data accepted into the backbone are diversified through CSPDarkNet-53. Feature maps are extracted using Spatial Pyramid Pooling and a Path Aggregation Network in the neck part. The head part aggregates and generates the final output. All bounding boxes by the YOLO v4 are mapped onto the 3D reconstructed bone images after being resized to match the same region as shown in the 2D CT images. The YOLO v4-based AI model was evaluated through precision-recall (PR) curves and the intersection over union (IoU). Our proposed system facilitated an intuitive display of the fractured area through a distinctive red mask overlaid on the 3D reconstructed bone images. The high average precision values (>0.60) were reported as 0.71 and 0.81 from the PR curves of the tibia and elbow, respectively. The IoU values were calculated as 0.6327 (tibia) and 0.6638 (elbow). When utilized by orthopedic surgeons in real clinical scenarios, this AI-powered 3D diagnosis support system could enable a quick and accurate trauma diagnosis.

6.
J Pers Med ; 12(6)2022 Jun 02.
Article in English | MEDLINE | ID: mdl-35743711

ABSTRACT

The purpose of this study was to evaluate the restoration of original anatomy after fixation of sawbone fractures using case-specific 3D printing plates based on virtual reduction (VR). Three-dimensional models of 28 tibia sawbones with cortical marking holes were obtained. The sawbones were fractured at various locations of the shaft and 3D models were obtained. The fractured models were reduced virtually and customized non-locking metal plates that fit the reduced model were produced via 3D printing. The fractured sawbones were actually fixed to the customized plate with nonlocking screws and 3D models were generated. With the proximal fragments of the 3D models overlapped, the changes in length, 3D angulation, and rotation of the distal fragment were evaluated. Compared to the intact model (IN), the virtual reduction model (VR) and the actual fixation model (AF) showed no significant differences in length. Compared to the IN, the VR and the AF had mean 3D angulations of 0.39° and 0.64°, respectively. Compared to the IN model, the VR and the AF showed mean rotations of 0.89° and 1.51°, respectively. A customized plate based on VR facilitates the restoration of near-original anatomy in fractures of tibial sawbone shaft.

7.
Diagnostics (Basel) ; 12(6)2022 Jun 02.
Article in English | MEDLINE | ID: mdl-35741182

ABSTRACT

Background: The purpose of this study was to demonstrate the usefulness of 3D image-based virtual reduction by validating the evaluation criteria according to guidelines suggested by the AO Surgery Reference. Methods: For this experiment, 19 intact radial ORTHObones (ORTHObones radius, 3B Scientific, Germany, Hamburg) without any fractures were prepared. All ORTHObones with six cortical marking holes (three points on the distal part and three points on the proximal part) were scanned using a CT scanner twice (before/after intentional fracture of the ORTHObone). After the virtual reduction of all 19 ORTHObones, accuracy evaluations using the four criteria (length variation, apposition variation, alignment variation, Rotation Variation) suggested in the AO Surgery Reference were performed. Results: The mean (M) length variation was 0.42 mm, with 0.01 mm standard deviation (SD). The M apposition variation was 0.48 mm, with 0.40 mm SD. The M AP angulation variation (for alignment variation) was 3.24°, with 2.95° SD. The M lateral angulation variation (for alignment variation) was 0.09°, with 0.13° SD. The M angle of axial rotation was 1.27° with SD: 1.19°. Conclusions: The method of accuracy evaluation used in this study can be helpful in establishing a reliable plan.

8.
Front Oncol ; 11: 622244, 2021.
Article in English | MEDLINE | ID: mdl-33732646

ABSTRACT

Effective radiation treatment (RT) for recurrent nasopharyngeal cancers (NPC), featuring an intrinsic hypoxic sub-volume, remains a clinical challenge. Lack of disease-specific in-vitro models of NPC, together with difficulties in establishing patient derived xenograft (PDX) models, have further hindered development of personalized therapeutic options. Herein, we established two NPC organoid lines from recurrent NPC PDX models and further characterized and compared these models with original patient tumors using RNA sequencing analysis. Organoids were cultured in hypoxic conditions to examine the effects of hypoxia and radioresistance. These models were then utilized to determine the radiobiological parameters, such as α/ß ratio and oxygen enhancement ratio (OER), characteristic to radiosensitive normoxic and radioresistant hypoxic NPC, using simple dose-survival data analytic tools. The results were further validated in-vitro and in-vivo, to determine the optimal boost dose and fractionation regimen required to achieve effective NPC tumor regression. Despite the differences in tumor microenvironment due to the lack of human stroma, RNA sequencing analysis revealed good correlation of NPC PDX and organoid models with patient tumors. Additionally, the established models also mimicked inter-tumoral heterogeneity. Hypoxic NPC organoids were highly radioresistant and had high α/ß ratio compared to its normoxic counterparts. In-vitro and in-vivo fractionation studies showed that hypoxic NPC was less sensitive to RT fractionation scheme and required a large bolus dose or 1.4 times of the fractionated dose that was effective against normoxic cells in order to compensate for oxygen deficiency. This study is the first direct experimental evidence to predict optimal RT boost dose required to cause sufficient damage to recurrent hypoxic NPC tumor cells, which can be further used to develop dose-painting algorithms in clinical practice.

9.
Radiat Oncol ; 15(1): 273, 2020 Dec 07.
Article in English | MEDLINE | ID: mdl-33287828

ABSTRACT

BACKGROUND: An O-ring gantry-type linear accelerator (LINAC) with a 6-MV flattening filter-free (FFF) photon beam, Halcyon, includes a reference beam that contains representative information such as the percent depth dose, profile and output factor for commissioning and quality assurance. However, because it does not provide information about the field size, we proposed a method to determine all field sizes according to all depths for radiation therapy using simplified sigmoidal curve fitting (SCF). METHODS: After mathematical definition of the SCF using four coefficients, the defined curves were fitted to both the reference data (RD) and the measured data (MD). For good agreement between the fitting curve and the profiles in each data set, the field sizes were determined by identifying the maximum point along the third derivative of the fitting curve. The curve fitting included the field sizes for beam profiles of 2 × 2, 4 × 4, 6 × 6, 8 × 8, 10 × 10, 20 × 20 and 28 × 28 cm2 as a function of depth (at 1.3, 5, 10 and 20 cm). The field size results from the RD were compared with the results from the MD using the same condition. RESULTS: All fitting curves show goodness of fit, R2, values that are greater than 0.99. The differences in field size between the RD and the MD were within the range of 0 to 0.2 cm. The smallest difference in the field sizes at a depth of 10 cm, which is a surface-to-axis distance, was reported. CONCLUSION: Application of the SCF method has been proven to accurately capture the field size of the preconfigured RD and the measured FFF photon beam data for the Halcyon system. The current work can be useful for beam commissioning as a countercheck methodology to determine the field size from RD in the treatment planning system of a newly installed Halcyon system and for routine quality assurance to ascertain the correctness of field sizes for clinical use of the Halcyon system.


Subject(s)
Particle Accelerators , Photons/therapeutic use , Quality Assurance, Health Care , Radiotherapy Planning, Computer-Assisted/methods , Humans
10.
J Appl Clin Med Phys ; 21(1): 136-143, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31729832

ABSTRACT

PURPOSE: We compared and analyzed the detectability performance pertaining to an abdominal phantom including a region of interest (ROI) according to a computed tomography (CT) reconstruction algorithm. METHODS: Three types of reconstruction algorithms (FBP, SAFIRE, and ADMIRE) were used to evaluate the detectability performance using the abdominal phantom (phantom size: 25 × 18 × 28 cm3 ). The vendor default settings for routine multi-detector computed tomography abdominal scans were used. As the quantitative evaluation method, the contrast-to-noise ratio (CNR), difference in coefficient of variation (COV) with the normalization based on the FBP data, and the noise power spectrum (NPS) were measured. RESULTS: The characteristic of the ADMIRE-3 reconstructed image was higher than those of the FBP and SAFIRE-3 reconstructed images. The CNR values of the SAFIRE and ADMIRE images were much higher than the corresponding values of the FBP images. The difference in COV values for the ADMIRE images was ~1.2 times lower than the corresponding values of the SAFIRE images. CONCLUSION: The comparative analysis of the abdominal phantom low-contrast resolution differences for each CT exposure parameters showed that ADMIRE demonstrated better results than SAFIRE and FBP in terms of contrast, CNR, COV difference, and 1D NPS. This indicates that ADMIRE can provide a clearer observation even with the same number of contrast objects as compared to SAFIRE and FBP owing to its better contrast resolution in the central part of the contrast hole at low kV.


Subject(s)
Abdomen/diagnostic imaging , Algorithms , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Humans , Radiation Dosage
11.
Phys Med ; 66: 29-35, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31550531

ABSTRACT

PURPOSE: To clarify the physical characteristics of a newly developed real time variable shape rubber containing tungsten (STR) with changes in heat and estimate its shielding abilities against electron beams and γ-rays from 192Ir. METHODS: Dynamic mechanical analysis for the STR (density = 7.3 g/cm3) was conducted at a frequency of 1.0 Hz in the temperature range of -60 °C to 60 °C. We evaluated tanδ, defined as the ratio (E″/E') between the storage modulus (E') and loss modulus (E″). The transmission rates were measured against 6- and 12-MeV electron beams and the percentage depth dose and lateral dose profile were compared with low-melting alloy (LMA). For the shielding rate of 192Ir against γ-rays, measurement data and Monte Carlo simulation data were obtained with STR thickness ranging from 1.0 mm to 16.0 mm. RESULTS: At 36 °C, the tanδ value was 0.520, while at 60 °C, this value was 1.016. For 6- and 12-MeV electron beams, the transmission rates decreased with increasing STR thickness and reached plateaus at approximately 1.0% and 4.0% with STR thickness of >7.0 and >12.0 mm, respectively. The dose distributions were almost equal to those for LMA. Against γ-rays, the thickness of STR that obtained a 50% attenuation rate for 192Ir was 5.804 mm. The Monte Carlo calculation results were 2.6% higher on average than the measurement results. CONCLUSION: The STR can be changed shape in real time at 60 °C and maintains its shape at body temperatures. It has adequate shielding abilities against megavoltage electron beams and γ-rays from 192Ir.


Subject(s)
Brachytherapy/adverse effects , Electrons/adverse effects , Radiation Protection/instrumentation , Rubber , Tungsten , Electrons/therapeutic use , Temperature , Time Factors
12.
Radiat Oncol ; 13(1): 163, 2018 Aug 31.
Article in English | MEDLINE | ID: mdl-30170614

ABSTRACT

BACKGROUND: This study clarified the mechanical performance of volumetric modulated arc therapy (VMAT) plans for prostate cancer generated with a commercial knowledge-based treatment planning (KBP) and whether KBP system could be applied clinically without any major problems with mechanical performance. METHODS: Thirty consecutive prostate cancer patients who underwent VMAT using extant clinical plans were evaluated. The mechanical performance and dosimetric accuracy of the single optimized KBPs, which were trained with other 51 clinical plans, were compared with the clinical plans. The mechanical performance metrics were mean field area (MFA), mean asymmetry distance (MAD), cross-axis score (CAS), closed leaf score (CLS), small aperture score (SAS), leaf travel (LT), modulation complexity score (MCSv), and monitor unit (MU). The γ passing rates were evaluated with ArcCheck and EBT3 film. RESULTS: The mean mechanical performance metrics (clinical plan vs. KBP) were as follows: 18.28 cm2 vs. 17.25 cm2 (MFA), 21.08 mm vs. 20.47 mm (MAD), 0.54 vs. 0.55 (CAS), 0.040 vs. 0.051 (CLS), 0.20 vs. 0.23 (SAS5mm), 458.5 mm vs. 418.8 mm (LT), 0.27 vs. 0.27 (MCSv), and 618.2 vs. 622.1 (MU), respectively. Significant differences were observed for CLS and LT. The average γ passing rates (clinical plan vs. KBP) were as follows: 99.0% vs. 99.1% (3%/3 mm) and 92.4% vs. 92.5% (2%/2 mm) with ArcCHeck, and 99.5% vs. 99.4% (3%/3 mm) and 95.2% vs. 95.4% (2%/2 mm) with EBT3 film, respectively. CONCLUSIONS: The KBP used lower multileaf collimator (MLC) travel and more closed or small MLC apertures than the clinical plan. The KBP system of VMAT for the prostate cancer was acceptable for clinical use without any major problems.


Subject(s)
Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Male , Radiometry , Radiotherapy Dosage
13.
Oncotarget ; 9(3): 3089-3096, 2018 Jan 09.
Article in English | MEDLINE | ID: mdl-29423031

ABSTRACT

The purpose of this study is to evaluate the prompt gamma ray imaging technique according to the clinical boron concentration range during proton boron fusion therapy (PBFT). To acquire a prompt gamma ray image from 32 projections, we simulated four head single photon emission computed tomography and a proton beam nozzle using a Monte Carlo simulation. We used modified ordered subset expectation maximization reconstruction algorithm with a graphic processing unit for fast image acquisition. Boron concentration was set as 20 to 100 µg at intervals of 20 µg. For quantitative analysis of the prompt gamma ray image, we acquired an image profile drawn through two boron uptake regions (BURs) and calculated the contrast value, signal-to-noise ratio (SNR), and difference between the physical target volume and volume of the prompt gamma ray image. The relative counts of prompt gamma rays were noticeably increased with increasing boron concentration. Although the intensities on the image profiles showed a similar tendency according to the boron concentration, the SNR and contrast value were improved with increasing boron concentration. This study suggests that a tumor monitoring technique using prompt gamma ray detection can be clinically applicable even if the boron concentration is relatively low.

14.
Phys Med ; 44: 243-248, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28551298

ABSTRACT

PURPOSE: In nuclear medicine, the standardized uptake value (SUV) obtained using positron emission tomography with 2-deoxy-2-fluoro-D-glucose (FDG-PET) is widely used as a semi-quantitative diagnosis factor. We found that the header file of the Philips Allegro PET scanner using the Digital Imaging and Communications in Medicine (DICOM) standard was stored differently than with other scanners. Thus, the purpose of this study was to develop a DICOM header information conversion program to ensure compatibility between Allegro and other equipment. METHODS AND RESULTS: The NEMA IEC Body phantom was scanned using the Allegro PET scanner. We conducted measurements and performed calculations by using commercial software and the proposed self-developed program, respectively, to compare the SUVs by using conversion data. The program consists of three parts: an input part that can load data regardless of the number of DICOM images, and conversion and output parts that can be used to convert the DICOM header information and store it in the order of slices. The results of the calculation are in good agreement with the data measured at 12 circular regions of interest. The percent difference was lower than the 20%. CONCLUSION: In conclusion, this study suggested a simple and convenient method to solve the incompatibility through conversion of the DICOM header information. This study thus provides physicians more accurate information for diagnosis and treatment.


Subject(s)
Positron-Emission Tomography/instrumentation , Biological Transport , Communication , Equipment Design , Fluorodeoxyglucose F18/metabolism , Image Processing, Computer-Assisted , Positron-Emission Tomography/standards , Reference Standards
15.
Oncotarget ; 8(24): 39774-39781, 2017 Jun 13.
Article in English | MEDLINE | ID: mdl-28427153

ABSTRACT

The aim of this study is to compare between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT) and to analyze dose escalation using a Monte Carlo simulation. We simulated a proton beam passing through the water with a boron uptake region (BUR) in MCNPX. To estimate the interaction between neutrons/protons and borons by the alpha particle, the simulation yielded with a variation of the center of the BUR location and proton energies. The variation and influence about the alpha particle were observed from the percent depth dose (PDD) and cross-plane dose profile of both the neutron and proton beams. The peak value of the maximum dose level when the boron particle was accurately labeled at the region was 192.4% among the energies. In all, we confirmed that prompt gamma rays of 478 keV and 719 keV were generated by the nuclear reactions in PBFT and BNCT, respectively. We validated the dramatic effectiveness of the alpha particle, especially in PBFT. The utility of PBFT was verified using the simulation and it has a potential for application in radiotherapy.


Subject(s)
Boron Neutron Capture Therapy , Phantoms, Imaging , Protons , Computer Simulation , Humans , Monte Carlo Method , Radiotherapy Dosage
16.
Phys Med ; 32(10): 1284-1291, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27378392

ABSTRACT

PURPOSE: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room-laser-based alignment system. To verify the feasibility of the RAMS, reproducibility and accuracy tests were conducted. METHODS: RAMS was composed of a room laser sensing array (RLSA), an electric circuit, an analog-to-digital converter (ADC), and a control PC. The RLSA was designed to arrange photodiodes in a pattern that results in the RAMS having a resolution of 1mm. The photodiodes were used for quantitative assessment of the alignment condition. To verify the usability of the developed system, we conducted tests of temporal reproducibility, repeatability, and accuracy. RESULTS: The results of the temporal reproducibility test suggested that the signal of the RAMS was stable with respect to time. Further, the repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. The accuracy test confirmed that the "on" and "off" signals could be distinguished by signal intensity, considering that the "off" signal was below 75% of the "on" signal in every case. In addition, we confirmed that the system can detect 1mm of movement by monitoring the pattern of the "on" and "off" signals. CONCLUSION: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. We expect that the RAMS can propose the potential of the room laser based alignment monitoring method.


Subject(s)
Lasers , Monitoring, Physiologic/instrumentation , Patient Positioning/instrumentation , Biophysical Phenomena , Equipment Design , Feasibility Studies , Humans , Monitoring, Physiologic/statistics & numerical data , Patient Positioning/statistics & numerical data , Reproducibility of Results , Software Design
17.
Phys Med ; 32(10): 1271-1275, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27229367

ABSTRACT

PURPOSE: The purpose of this study was to verify acquisition feasibility of a single photon emission computed tomography image using prompt gamma rays for proton boron fusion therapy (PBFT) and to confirm an enhanced therapeutic effect of PBFT by comparison with conventional proton therapy without use of boron. METHODS: Monte Carlo simulation was performed to acquire reconstructed image during PBFT. We acquired percentage depth dose (PDD) of the proton beams in a water phantom, energy spectrum of the prompt gamma rays, and tomographic images, including the boron uptake region (BUR; target). The prompt gamma ray image was reconstructed using maximum likelihood expectation maximisation (MLEM) with 64 projection raw data. To verify the reconstructed image, both an image profile and contrast analysis according to the iteration number were conducted. In addition, the physical distance between two BURs in the region of interest of each BUR was measured. RESULTS: The PDD of the proton beam from the water phantom including the BURs shows more efficient than that of conventional proton therapy on tumour region. A 719keV prompt gamma ray peak was clearly observed in the prompt gamma ray energy spectrum. The prompt gamma ray image was reconstructed successfully using 64 projections. Different image profiles including two BURs were acquired from the reconstructed image according to the iteration number. CONCLUSION: We confirmed successful acquisition of a prompt gamma ray image during PBFT. In addition, the quantitative image analysis results showed relatively good performance for further study.


Subject(s)
Boron/radiation effects , Boron/therapeutic use , Proton Therapy/methods , Proton Therapy/statistics & numerical data , Tomography, Emission-Computed, Single-Photon/statistics & numerical data , Biophysical Phenomena , Computer Simulation , Feasibility Studies , Gamma Rays , Humans , Image Processing, Computer-Assisted , Monte Carlo Method , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Phantoms, Imaging , Proton Therapy/instrumentation
18.
Phys Med ; 32(4): 562-7, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26970679

ABSTRACT

We confirmed the feasibility of using our proposed system to extract two different kinds of functional images from a positron emission tomography (PET) module by using an insertable collimator during boron neutron capture therapy (BNCT). Coincidence events from a tumor region that included boron particles were identified by a PET scanner before BNCT; subsequently, the prompt gamma ray events from the same tumor region were collected after exposure to an external neutron beam through an insertable collimator on the PET detector. Five tumor regions that contained boron particles and were located in the water phantom and in the BNCT system with the PET module were simulated with Monte Carlo simulation code. The acquired images were quantitatively analyzed. Based on the receiver operating characteristic (ROC) curves in the five boron regions, A, B, C, D, and E, the PET and single-photon images were 10.2%, 11.7%, 8.2% (center region), 12.6%, and 10.5%, respectively. We were able to acquire simultaneously PET and single prompt photon images for tumor regions monitoring by using an insertable collimator without any additional isotopes.


Subject(s)
Boron Neutron Capture Therapy/methods , Neoplasms/diagnostic imaging , Neoplasms/therapy , Positron-Emission Tomography/methods , Computer Simulation , Gamma Rays , Humans , Monte Carlo Method
19.
Med Phys ; 42(1): 165-9, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25563257

ABSTRACT

PURPOSE: The purpose of this research is to perform the fast reconstruction of a prompt gamma ray image using a graphics processing unit (GPU) computation from boron neutron capture therapy (BNCT) simulations. METHODS: To evaluate the accuracy of the reconstructed image, a phantom including four boron uptake regions (BURs) was used in the simulation. After the Monte Carlo simulation of the BNCT, the modified ordered subset expectation maximization reconstruction algorithm using the GPU computation was used to reconstruct the images with fewer projections. The computation times for image reconstruction were compared between the GPU and the central processing unit (CPU). Also, the accuracy of the reconstructed image was evaluated by a receiver operating characteristic (ROC) curve analysis. RESULTS: The image reconstruction time using the GPU was 196 times faster than the conventional reconstruction time using the CPU. For the four BURs, the area under curve values from the ROC curve were 0.6726 (A-region), 0.6890 (B-region), 0.7384 (C-region), and 0.8009 (D-region). CONCLUSIONS: The tomographic image using the prompt gamma ray event from the BNCT simulation was acquired using the GPU computation in order to perform a fast reconstruction during treatment. The authors verified the feasibility of the prompt gamma ray image reconstruction using the GPU computation for BNCT simulations.


Subject(s)
Algorithms , Boron Neutron Capture Therapy , Computer Graphics , Gamma Rays/therapeutic use , Image Processing, Computer-Assisted/methods , Tumor Burden/radiation effects