Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Heart Rhythm ; 2024 Sep 19.
Article in English | MEDLINE | ID: mdl-39304002

ABSTRACT

BACKGROUND: Data regarding the effects of pulsed field ablation (PFA) on atrioventricular nodal reentrant tachycardia (AVNRT) are limited. OBJECTIVE: This study was undertaken to evaluate the outcomes of PFA for AVNRT and its impact on dual-pathway electrophysiology. METHODS: A larger cohort of patients with typical AVNRT underwent slow pathway (SP) modification (SPM) using a focal PFA catheter in a biphasic/bipolar manner. The primary endpoints were the efficacy and safety of PFA during the procedure and at 6-month follow-up. RESULTS: The acute success of SPM was achieved in all 40 patients. The total ablation time was 7.9 ± 3.8 seconds for 6.4 ± 2.2 ablation sites (ASs). Slow junctional rhythm (SJR) was induced in 32 (80%) patients, lasting 28.9 ± 10.3 seconds in 3.0 ± 1.1 ASs per patient. SP was located 11.1 ± 1.2 mm from the largest His activation (LHA). At 9 ASs, SJR could be reinduced after an increase of contact force (CF) from 1.3 ± 0.5g to 6.4 ± 1.3 g (P < .0001). Transient atrioventricular block (AVB) was recorded in 7 (17.5%) patients (1 second-degree and 6 third-degree AVB) lasting 435.3 ± 227.4 seconds, with a shorter AS-LHA distance than patients without AVB (7.7 ± 0.6 mm vs. 11.3 ± 1 mm; P < .0001). PFA-related delayed atrial-His (n = 6) and His-atrial (n = 1) conduction preceded transient AVB with a constant His-ventricular interval. Normal PR interval was restored within 24 hours. All patients maintained sinus rhythm without any significant adverse events during 6-month follow-up. CONCLUSION: Despite the high efficiency of PFA for SPM, the notable incidence of transient AVB warranted caution when applying it near the His bundle. SJR frequently occurred during SPM and was dependent on moderate CF.

2.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38801673

ABSTRACT

AIMS: Radiofrequency ablation is used as a first-line therapy for accessory pathways (APs). However, data regarding the effects of pulsed field ablation (PFA) on APs are limited. We sought to evaluate the acute procedural and 6-month success and safety of PFA in a cohort of patients with APs. METHODS AND RESULTS: A focal contact force-sensing PFA catheter was used for patients with APs. Pulsed field ablation generator generated a bipolar and biphasic waveform (±1000 V) with a duration of 100 ms from the tip of the PFA catheter. A 100% acute procedural success was achieved in 10 conscious patients with APs (7 left anterolateral, 2 left inferolateral, and 1 right posteroseptal APs) including 6 (60%) patients after an initial application. The average total ablation time was 6.3 ± 4.9 s for 4.7 ± 1.8 ablation sites (ASs), including 3.1 ± 2.4 s at targets and 3.2 ± 2.9 s at 3.2 ± 2 bolus ASs. The mean skin-to-skin time was 59.3 ± 15.5 min, and PFA catheter dwell time was 29.4 ± 7.8 min. One patient encountered transient sinus arrest during PFA due to parasympathetic overexcitation. Sinus rhythm was restored in all patients without any significant adverse events during the short-term follow-up. CONCLUSION: Pulsed field ablation of APs was feasible, effective, and safe. Its efficiency was remarkable for its ultrarapid termination of AP conduction. Further studies are warranted to prove whether utilization of PFA with current parameters can extend to manifold AP ablation.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Radiofrequency Ablation , Tachycardia, Ventricular , Radiofrequency Ablation/adverse effects , Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Pilot Projects , Tachycardia, Ventricular/therapy , Catheter Ablation/methods
SELECTION OF CITATIONS
SEARCH DETAIL