Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add more filters











Publication year range
1.
Korean Journal of Radiology ; : 1163-1171, 2021.
Article in English | WPRIM (Western Pacific) | ID: wpr-894741

ABSTRACT

Objective@#To analyze the correlations between intraoperative ultrasound and MRI metrics of the spinal cord in degenerative cervical myelopathy and identify novel potential predictive ultrasonic indicators of neurological recovery for degenerative cervical myelopathy. @*Materials and Methods@#Twenty-two patients who underwent French-door laminoplasty for multilevel degenerative cervical myelopathy were followed up for 12 months. The Japanese Orthopedic Association (JOA) scores were assessed preoperatively and 12 months postoperatively. Maximum spinal cord compression and compression rates were measured and calculated using both intraoperative ultrasound imaging and preoperative T2-weight (T2W) MRI. Signal change rates of the spinal cord on preoperative T2W MRI and gray value ratios of dorsal and ventral spinal cord hyperechogenicity on intraoperative ultrasound imaging were measured and calculated. Correlations between intraoperative ultrasound metrics, MRI metrics, and the recovery rate JOA scores were analyzed using Spearman correlation analysis. @*Results@#The postoperative JOA scores improved significantly, with a mean recovery rate of 65.0 ± 20.3% (p < 0.001). No significant correlations were found between the operative ultrasound metrics and MRI metrics. The gray value ratios of the spinal cord hyperechogenicity was negatively correlated with the recovery rate of JOA scores (ρ = -0.638, p = 0.001), while the ventral and dorsal gray value ratios of spinal cord hyperechogenicity were negatively correlated with the recovery rate of JOA-motor scores (ρ = -0.582, p = 0.004) and JOA-sensory scores (ρ = -0.452, p = 0.035), respectively. The dorsal gray value ratio was significantly higher than the ventral gray value ratio (p < 0.001), while the recovery rate of JOA-motor scores was better than that of JOA-sensory scores at 12 months post-surgery (p = 0.028). @*Conclusion@#For degenerative cervical myelopathy, the correlations between intraoperative ultrasound and preoperative T2W MRI metrics were not significant. Gray value ratios of the spinal cord hyperechogenicity and dorsal and ventral spinal cord hyperechogenicity were significantly correlated with neurological recovery at 12 months postoperatively.

2.
Korean Journal of Radiology ; : 1163-1171, 2021.
Article in English | WPRIM (Western Pacific) | ID: wpr-902445

ABSTRACT

Objective@#To analyze the correlations between intraoperative ultrasound and MRI metrics of the spinal cord in degenerative cervical myelopathy and identify novel potential predictive ultrasonic indicators of neurological recovery for degenerative cervical myelopathy. @*Materials and Methods@#Twenty-two patients who underwent French-door laminoplasty for multilevel degenerative cervical myelopathy were followed up for 12 months. The Japanese Orthopedic Association (JOA) scores were assessed preoperatively and 12 months postoperatively. Maximum spinal cord compression and compression rates were measured and calculated using both intraoperative ultrasound imaging and preoperative T2-weight (T2W) MRI. Signal change rates of the spinal cord on preoperative T2W MRI and gray value ratios of dorsal and ventral spinal cord hyperechogenicity on intraoperative ultrasound imaging were measured and calculated. Correlations between intraoperative ultrasound metrics, MRI metrics, and the recovery rate JOA scores were analyzed using Spearman correlation analysis. @*Results@#The postoperative JOA scores improved significantly, with a mean recovery rate of 65.0 ± 20.3% (p < 0.001). No significant correlations were found between the operative ultrasound metrics and MRI metrics. The gray value ratios of the spinal cord hyperechogenicity was negatively correlated with the recovery rate of JOA scores (ρ = -0.638, p = 0.001), while the ventral and dorsal gray value ratios of spinal cord hyperechogenicity were negatively correlated with the recovery rate of JOA-motor scores (ρ = -0.582, p = 0.004) and JOA-sensory scores (ρ = -0.452, p = 0.035), respectively. The dorsal gray value ratio was significantly higher than the ventral gray value ratio (p < 0.001), while the recovery rate of JOA-motor scores was better than that of JOA-sensory scores at 12 months post-surgery (p = 0.028). @*Conclusion@#For degenerative cervical myelopathy, the correlations between intraoperative ultrasound and preoperative T2W MRI metrics were not significant. Gray value ratios of the spinal cord hyperechogenicity and dorsal and ventral spinal cord hyperechogenicity were significantly correlated with neurological recovery at 12 months postoperatively.

3.
Journal of Chinese Physician ; (12): 180-183, 2019.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-744845

ABSTRACT

Objective To compare the value of ultrasound-guided fine-needle aspiration (FNA) and core needle biopsy (CNB) in diagnosing benign and malignant cervical lymph nodes.Methods A retrospective analysis was performed on 88 patients who received biopsy for cervical lymph node enlargement from January 2015 to May 2017.FNA (n =39) or CNB (n =49) were performed respectively to compare the sensitivity,specificity and accuracy of the two methods in diagnosing benign and malignant cervical lymph node enlargement.Results 84.6% (33/39) of FNA cases were successfully collected,and 98% (48/49) of FNA cases were successfully collected for definite pathological diagnosis (P =0.000).The sensitivity,specificity and accuracy of FNA and CNB in diagnosing malignant cervical lymph nodes were 90.9% and 97.2%,94.1% and 100%,92.3% and 98%,respectively.Compared with FNA,there were statistically significant differences in sensitivity,specificity and accuracy in differentiating benign and malignant lymphatic lesions in cervical enlargement (P <0.01).The sensitivity and specificity of FNA and CNB in diagnosing cervical lymph node metastatic carcinoma were 100% and 100%,95.2% and 100%.Compared with FNA,there was no statistically significant difference in the sensitivity to the diagnosis of cervical lymph node metastatic carcinoma (P =0.102).Conclusions CNB is superior to FNA in sensitivity,specificity and accuracy in diagnosing cervical lymphadenopathy.However,when metastatic cancer was diagnosed,FNA was not significantly different from CNB in sensitivity (P =0.102),and FNA was recommended as the first choice.

4.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-706225

ABSTRACT

Objective To investigate the value of CEUS in differential diagnosis of benign and malignant renal focal hyperechoic lesions.Methods Data of conventional ultrasound (US) and CEUS of 56 patients with single renal focal hyperechoic lesion were retrospectively analyzed,and differential diagnosis of benign and malignant lesions was performed with US and CEUS,respectively.Taking pathological diagnosis as golden standard,the diagnostic efficacy of US and CEUS were calculated and compared.Results The sensibility,specificity,positive predictive value (PPV),negative predictive value (NPV) and accuracy of US was 70.00% (14/20),75.00% (27/36),60.87% (14/23),81.82% (27/33) and 73.21% (41/56),while of CEUS was 80.00% (16/20),94.44% (34/36),88.89% (16/18),89.47% (34/38) and 89.29 % (50/56),respectively.The accuracy,specificity and PPV of CEUS were higher than those of US (all P<0.05).The consistency of CEUS and pathology was good (Kappa=0.761),while of US and pathology was ordinary (Kappa=0.435).Conclusion CEUS can improve differential diagnostic efficacy of renal focal hyperechoic lesions.

5.
Organ Transplantation ; (6): 41-45, 2015.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-731567

ABSTRACT

Objective To evaluate the application value of contrast-enhanced ultrasound (CEUS) in the diagnosis of vascular complication (VC) of transplanted kidney. Methods Imaging data of conventional ultrasound and CEUS in 28 patients suspected with VC of transplanted kidney were analyzed retrospectively.The results of computed tomography angiography (CTA)or digital subtraction angiography (DSA)were served as the diagnostic standard. The value of CEUS in diagnosing VC of transplanted kidney was analyzed. Results No adverse reaction related to contrast agent was observed in 28 patients during the CEUS examination. And 22 cases with VC were confirmed. VCs were detected correctly by CEUS in 17 cases,but 5 cases with transplant renal artery stenosis (TRAS ) were missed and 1 case with focal infarction in transplanted kidney was misdiagnosed. The diagnostic sensitivity,specificity,positive predictive value (PPV),negative predictive value (NPV)and accuracy of CEUS for VC of transplanted kidney were 0.77,1.00,1.00,0.55 and 0.82, respectively. The diagnostic sensitivity,specificity,PPV,NPV and accuracy of conventional ultrasound and CEUS for TRAS were 0.37 and 0.74,0.89 and 1.00,0.88 and 1.00,0.40 and 0.64,0.54 and 0.82, respectively. There were significant differences in the sensitivity and accuracy between conventional ultrasound and CEUS (both in P<0.05 ). Conclusions CEUS is an effective method for detecting VC of transplanted kidney.

6.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-434795

ABSTRACT

Objective To investigate the value of contrast-enhanced ultrasound (CEUS) in percutaneous nephrostomy for the treatment of complex renal calculi without hydronephrosis.Methods 22 patients with complex renal calculi underwent puncture and catheterization under the conventional ultrasound guidance,and then were injected with ultrasound contrast agent (SonoVue) through the needles and tubes to confirm appropriate puncture and catheterization.The display rates of puncture needle,renal pelvis,calyces,drainage tube body and distal end under CEUS were observed,and the results were compared with those of routine ultrasonography.The dosage of contrast agent,success rate and complications were also recorded.Results The display rates of puncture needle,renal pelvis,calyces,drainage tube body and distal end under routine ultrasonography were 63.64%,36.36%,63.64%,18.18%,as compared with CEUS the display rates were 100%,100%,100%,81.18%.The differences were statistically significant between CEUS and routine ultrasonography (P < 0.05).Conclusions CEUS guided percutaneous catheterization makes up for the inadequacy of conventional ultrasound in patients of complex renal calculi without hydronephrosis,and it can be worthy for clinical application.

7.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-437650

ABSTRACT

Objective To evaluate the therapeutic efficacy and safety of radiofrequency ablation (RFA) combined with ethanol injection with a multipronged needle under ultrasound guidance for the treatment of hepatocellular carcinoma (HCC) larger than 3 cm in diameter.Methods 65 patients with 67HCC nodules ranging from 3.1 to 7.0 cm in diameter were treated percutaneously under ultrasound guidance.Tumor response and complications after treatment were observed.Results Complete ablation was achieved in 94.0% (63/67) of HCC nodules.4 residual tumor nodules received complete ablation after additional treatment.Ablation-related major complications was occurred in 3 patients,including liver abscess in 1 case,abdominal bleeding in 1 case and massive ascites in 1 case,all were cured by conservative therapy.After a mean follow-up period of (20.0 ± 7.6) months (6.7-32.6 months),local-tumor progression was observed in 10 (14.9%) of 67 HCC nodules,and distant recurrence was observed in 32 (49.2%) of 65patients.The 1-year and 2-year survival rate were 93.1 % and 88.1%,respectively.Conclusions RFA combined with ethanol injetion with a multipronged needle is a safe and effective technique for the treatment of hepatocellular carcinoma larger than 3 cm,especially 3-5 cm in diameter.

8.
Chinese Journal of Ultrasonography ; (12): 1048-1051, 2012.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-430023

ABSTRACT

Objective To compare the enhancement characteristic of the gallbladder diseases and to evaluate the diagnostic efficacy in differential diagnosis of the gallbladder diseases between contrast-enhanced sonography (CEUS) and contrast-enhanced computed tomography (CECT).Methods Seventy-two patiens with gallbladder lesions were examined by CEUS and CECT before operation and all final diagnoses were confirmed by surgery and/or pathological diagnosis.Results 1)In early phase,84.6% (33/39) and 79.5% (31/39) of benign diseases showed hyper-enhancement on CEUS and CECT,and 97.0% (32/33) and 87.9% (29/33) of malignant diseases showed hyper-enhancement on CEUS and CECT respectively (P =0.250).In later phase,91.2% (31/34) and 88.2% (30/34) of benign diseases showing hypo-enhancement (P =1.000),and 100% of the malignant diseases showing hypo-enhancement on CEUS and CECT respectively.2)The time of enhancement from hyper-to hypo in CEUS for benign and malignant diseases were (39.9 ± 15.7)s and (29.9 ± 5.6)s respectively (t =3.61,P =1.000).3)The inhomogeneous enhancement on CEUS and CECT were 41.0% (16/39) and 53.8% (21/39) in the benign diseases respectively (P =0.063),84.8 % (28/33) and 97.0 % (32/33) in the malignant diseases respectively(P =0.125).4)The destruction of the gallbladder wall on CEUS and CECT are 87.9% (29/33) and 90.9% (30/33) respectively(P =1.000).5)The accuracy,diagnostic sensitivity,specificity of CEUS and CECT were 91.7%(66/72) and 87.5%(63/72),97.0%(32/33) and 93.9%(31/33),87.2%(34/39) and 82.15% (32/39) respectively (P =0.250,1.000,0.500).Conclusions The enhancement pattern of the gallbladder diseases on CEUS and CECT were much similar.CEUS has equal diagnostic efficacy in comparison with CECT,but CEUS can supply more diagnostic information than CECT.

9.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-416501

ABSTRACT

Objective To identify microbubbles targeted (MBt) to alpha(v)beta(3) (αvβ3) via biotin-avidin bridge and evaluate the adhesion to human umbilical vein endothelial cells (HUVECs) in vitro.Methods MBt produced via biotin-avidin bridge were validated using fluorescence in vitro.Adhesion of αvβ3-integrin targeted MBt (MBαvβ3) to HUVECs was tested using the parallel plate flow chamber (PPFC) test.Results Bright green fluorescence was observed on the biotinylated microbubbles(MBB) incubated with fluorescein isothiocyanate labeled streptavidin (FITC-SA) and on MBB-SA incubated with FITC labeled biotin.There was no fluorescence seen on non-targeted control microbubbles,MBB incubated with FITC labeled protein A and MBB-SA incubated with FITC labeled protein A. The adherent rate of MBαvβ3 was significantly higher than MBt with non-specific antibody (MBN) in PPFC test,with 9.9±3.1 of MBαvβ3 and 0.8±0.3 of MBN adhered to HUVECs,respectively(P<0.05).Conclusions Avβ3 targeted microbubbles using biotin-avidin bridging method is highly efficient and reliable for HUVECs.

10.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-416618

ABSTRACT

Objective To study the efficacy of percutaneous ablative therapy for malignant liver lesions under real-time virtual guidance. Methods Percutaneous ablations were applied to 76 patients with 125 malignant liver lesions under the guidance of a real time virtual system (RVS). 64. 8% (81/ 125) lesions were undetectable on conventional ultrasound (US). The time spent on image fusion and the local treatment response were studied. Results The average time taken to synchronize the ultrasound and CT images was (19. 2±12. 8) min (range 5~55 min). Complete ablations were achieved in 86. 4% (38/44) of distinctly visualized lesions and in 91. 6% (74/81) of poorly visualized lesions on US. No treatment associated complications were found. Conclusion Ablation assisted by RVS and CT was safe and efficacious, especially for lesions undetectable by conventional ultrasound.

11.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-421361

ABSTRACT

Objective To investigate the feasibility and method of Sonazoid contrast-enhanced ultrasound (CEUS) for diagnosis of liver fibrosis/cirrhosis. Methods Liver cirrhosis was induced by oral administration of carbon tetrachloride to male wistar rats. Both conventional ultrasound and Sonazoid-CEUS were applied to each rat, respectively. Qualitative and quantitive analysis were performed, and the diagnostic performance of Sonazoid-CEUS on diagnosis of liver fibrosis/cirrhosis were analyzed. Results Twenty four rats were divided into three groups as group 1 (normal liver, n =5),group 2(fibrotic liver, n =6) and group 3 (cirrhotic liver, n =13). The Kupffer phase findings of Sonazoid-CEUS were as following: the enhancement level of normal liver was significantly higher than those of fibrotic/cirrhotic liver, and the difference between liver and spleen of fibrotic/cirrhotic liver was larger than those of normal liver with significant difference. Sonazoid-CEUS showed higher performance on diagnosis of liver fibrosis/cirrhosis than conventional US, with the sensitivity, specificity and accuracy were 84.2%, 100% and 87.5%,respectively. The quantification data of liver and spleen further proved the characteristic findings of normal liver,fibrotic liver and cirrhotic liver in Kupffer phase. Conclusions Decrease of liver enhancement and increase of the difference between spleen and liver during Sonazoid-CEUS Kupffer phase are the typical findings of liver fibrosis/cirrhosis.

12.
Chinese Journal of Urology ; (12): 452-455, 2010.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-388315

ABSTRACT

Objective To compare contrast-enhanced ultrasound(CEUS)and contrast-enhaneed computed tomography(CECT)on the diagnosis of renal cell carcinoma(RCC). Methods CEUS and CECT were performed on 117 patients(87 men and 30 women)with 124 renal lesions(single nodule in 110 and two nodules in 7)from 2004 to 2008.Among them,there were 63 patients with 65 lesions diagnosed as RCC confirmed by pathology.The tumor enhancement pattern,extent,and dynamic change of CEUS and CECT were compared.The diagnostic efficacy of CEUS and the agreement of CECT and CEUS in diagnosing RCC were analyzed. Results The rate of displaying hypervascular performance on cortical phase,and pseudocapsule enhancement of the RCC lesions by CEUS and CECT were 87.7%(57/65)and 63.1%(41/65),89.2%(58/65)and 69.2%(45/65)(P<0.05).The rate of displaying heterogeneous enhancement were 72.3%(47/65)and 56.9%(37/65)(P>0.05)Using the diagnosis of CECT as reference diagnostic criteria,the sensitivity,specificity,positive predietive value,negative predictive value,and accuracy of CEUS in diagnosing RCC were 89.1%(57/64),91.7%(55/60),91.9%(57/62),88.7%(55/62)and 90.3%(112/124).The agreement of CECT and CEUS in diagnosing RCC was high(κ=0.806). Conclusions CEUS and CECT have the coordinate efficacy in diagnosing RCC.

13.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-389663

ABSTRACT

Objective To investigate the usefulness of parametric imaging of contrast-enhanced ultrasound(CEUS) in imaging hepatocellular carcinoma (HCC) using dynamic vascular patterns (DVP). Methods Thirty clinically or pathologically proven HCCs that had undergone CEUS were randomly included. SonoLiver CAP sofeware was used to analyze the CEUS images and reconstruct DVP parametric images. Results The rise time, time to peak and mean transit time were (16. 72±11. 07) s, (29. 92±14. 13) s,(115. 03±90. 91)s in HCC versus (26. 59±9. 60) s, (41.67±12. 59) s, (159.26±123. 74) s in the surrounding liver parenchyma (all P <0. 05). The perfusion index was (90. 41±102. 49) % in HCC versus (54. 10±24. 99)% in surrounding liver parenchyma( P = 0.044). DVP curve and DVP parametric image could both be divided into three types:washout,non-washout and cystic type. The percentages of which were 76.7% (23/30), 20.0% (6/30) and 3.3% (1/30) in DVP curves, respectively, and 66.7% (20/30), 30.0% (9/30) and 3.3% (1/30) in DVP parametric images,respectively. Conclusions Parametric image of CEUS could demonstrates the difference of flow perfusion static between HCC and surrounding liver parenchyma dynamically and directly.

14.
Chinese Journal of Ultrasonography ; (12): 1047-1050, 2010.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-385221

ABSTRACT

Objective To evaluate the accuracy and utility of percutaneous ultrasonic cholangiography in Bismuth staging of hilar cholangiocarcinoma. Methods Thirty patients who underwent surgery and obtained pathologic diagnosis of hilar cholangiocarcincoma were perspectively ruled in this study. All patients with hilar obstruction underwent baseline ultrasound (BUS), percutaneous ultrasonic cholangiography (PUSC) and percutaneous transhepatic cholangiography(PTC) respectively. Taking operative findings as reference standard,the accuracy of the three imaging modalities in staging of hilar cholangiocarcinoma was compared. Results Among 30 patients, the accuracy of classification among BUS, PUSC and PTC was 23.3 % (7/30), 73.3 % ( 22/30 ), 73.3 % (22/30), respectively. There was statistically significant difference between BUS and PUSC, but the difference between PUSC and PTC was not statistically significant.Conclusions As a new technique for cholangiography, PUSC expands the application of ultrasound in evaluating hilar cholangiocarcinoma and is comparable to PTC in classifying hilar cholangiocarcinoma by Bismuth classification.

15.
Chinese Journal of Ultrasonography ; (12): 1079-1081, 2010.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-385322

ABSTRACT

Objective To prepare targeted micorbubble with low immunogenicity. Methods The microbubbles were produced with different phospholipids and identified by the fluorescent method. Detect the level of C3a after reaction with human serum in vitro with enzyme-linked immunosorboent assay (ELISA) method and the number of microbubble binding with the streptavidin packed on the dish by using the parallel plate flow chamber. Results The level of C3a was (1.037±0.047)ng/ml in MBb group,(1. 326 ± 0. 042)ng/ml in MBe group and ( 1.004 ± 0.031 ) ng/ml in MBc group. The level of C3a in MBb group was significantly lower than that in MBe group( P <0.05),and there was no significantly difference between MBb group and MBc group ( P > 0. 05). The parallel plate flow experiments showed that the number of MBb(15.2 ± 11.3) in each field of view binding with the streptavidin packed on the dish was significantly fewer than that of MBe ( 103.2 ± 28.3) ( P<0.05 ), and there was no significantly difference between MBb and MBc(17.8 ± 11.9) ( P >0.05). Conclusions The targeted microbubble with low immunogenicity has been prepared successfully,which can be used for further experiment in vivo.

16.
Chinese Journal of Ultrasonography ; (12): 1057-1060, 2009.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-391924

ABSTRACT

Objective To investigate the features of low grade dysplastic nodule(LGDN)and high grade dysplastic nodule(HGDN)in cirrhotic liver on the baseline ultrasound(BUS)and contrast-enhanced ultrasound (CEUS).Methods Seventeen LGDNs and 16 HGDNs which were pathologically proved underwent baseline and CEUS examination.CEUS was performed with contrast pulse sequence(CPS)and contrast harmonic imaging (CHI)and used SonoVue as contrast agent.Results Significant differences(all P>0.05)were not shown between LGDN and HGDN for manifestations on both the BUS and CEUS.After contrast agent injected, hyperenhancement in arterial phase and hyper-or iso-enhancement in late phase,hypo-enhancement in early arterial phase and iso-enhancement through late arterial,portal and late phase,hyper-enhancement in arterial phase and hypo-enhancement in late phase,iso-enhancement in arterial,portal and late phase,iso-enhancement in arterial phase and hypo-enhancement in late phase were showed in 10(30.3%),10(30.3%),8(24.3%),4(12.1%),1(3.0%)cases of DN, respectively.Conclusions LGDN and HGDN displayed similar feature on both the BUS and CEUS.There were complicated manifestations of DN on the CEUS and the main contrast-enhanced sonographic feature of DN was,different from regenerative nodule and hepatocellular carcinoma.CEUS was helpful in diagnosing DN in cirrhotic liver.

17.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-394281

ABSTRACT

Objective To investigate the features of hepatic angiomyolipoma(AML) on contrast enhanced ultrasound (CEUS). Methods Ten pathologically proved AML lesions in 9 patients were evaluated by using baseline ultrasound and CEUS. CEUS was performed with contrast pulse sequencing technique and the contrast agent of SonoVue. Results On baseline ultrasound, 7 lesions exhibited mixed echoic,which was obvious hyperechoic combined with partly of hypoechoie; 3 lesions exhitited obvious hypereehoic. On color Doppler flow imaging artery signals were detected in all lesions. And the lesions had plenty or slightly plenty of artery supply,with resistive index about 0.53 4±0.10 (0.48~0.62). On CEUS, in the arterial phase, 9 lesions exhibited hyper-enhanced. In the portal phase, 5 lesions exhibited iso-enhancement,1 lesion was slightly hyper-enhancement and 3 lesions was hypo-enhancement. In the late phase 6 lesions were iso-enhancement and 3 lesions were hypo-enhancement. One lesion was all hypo-enhancement in all three phases. Conclusions There are some characteristic manifestations of hepatic AML in CEUS, which are helpful for the diagnosis of hepatic AML in a way,but we still need more experiences.

18.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-397033

ABSTRACT

Objective To evaluate the diagnostic performance of real-time contrast-enhanced ultrasound (CEUS)in characterizing complex cystic focal liver lesions(FLLs).Methods Sixty seven complex cystic FLLs in 65 patients were examined with baseline ultrasound(BUS)and CEUS.BUS and CEUS images were reviewed by a resident radiologist and a staff radiologist independently.Diagnostic performance was evaluated using receiver operating characteristic(ROC)analysis and the interobserver agreement was analyzed by weighted k statistics.Results After ROC analysis,the areas under the ROC curve(Az)were 0.917 for the staff radiologist and 0.774(P=0.044)for the resident radiologist on BUS,and were 0.935 and 0.922(P=0.42)on CEUS.A significant difference in Az between BUS and CEUS was found for the resident radiologist(0.774 versus 0.922,P=0.047),whereas not found for the staff radiologist(0.917 versus 0.935,P=0.38).Better results of specific diagnosis were obtained on CEUS[28.4%(19/67)before versus 58.2%(39/67)after review of CEUS images for resident radiologist,and 26.9%(18/67)versus 76.1%(51/67)for staff radiologist,both P<0.001].Interobserver agreement was improved after review of CEUS images[K=0.325(95%confidence interval:0.214-0.436)on BUS versus k=0.774(95%confidence interval:0.688-0.860)on CEUS].Conclusions Real-time CEUS improves the capability of discrimination between malignant and benign lesions and specific characterization for complex cystic FLLs,as well as the interobserver agreement.

19.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-398378

ABSTRACT

Objective To assess the characterization and usefulness of contrast enhanced ultrasound (CEUS)to diagnose solid focal lesions of pancreas(s-FLPs)in comparison to contrast enhanced computed tomography(CECT).Methods Forty-nine s-FLPs with final diagnosis were studied with low mechanical index CEUS and CECT.The enhanced patterns and diagnostic capability of CEUS were analyzed,and these results were compared with those from CECT.Results ①In CEUS,the perfusion of capillary could be detected in vascular phase.②The concordance of dual-phases enhanced patterns between CEUS and CECT was 73.5%(36/49).The concordance of enhanced level between early parenchymatous perfusion phase in CEUS and pancreatic phase in CECT could achieve 87.8%(43/49).Hypo/hypo enhancement was the most common enhanced pattern of pancreatic carcinoma in CEUS and CECT.③There was no statistical significance between CEUS and CECT in the differential diagnostic.Conclusions The concordance of enhanted patterns between CEUS and CECT is satisfactory.CEUS is similar to CECT in the differential diagnosis of s-FLPs.CEUS would become an important non-invasive diagnostic method for s-FLPs.

20.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-398425

ABSTRACT

Objective To evaluate the feasilibility of ultrasonic cholangiography(USC)with contrast agent SonoVue in evaluating the obstructive bile duct diseases.Methods Twenty patients with obstructive jaundice(choledocholithiasis in 4,post-operative biliary strictures in 2 and malignant tumors in 14)underwent uhrasound-guided percutaneous transhepatic cholangiodrainge drainage(PTCD).Afterward,USC with contrast agent SonoVue administrated from the PTCD tube and percutaneous transhepatic cholangiography(PTC)were carried out in each patient.By using the surgical or PTC findings as reference standard,accuracy of USC in determining the obstructive level and cause of bstructive was evaluated.Results ①The visualization of contrast agent SonoVue was successfully obtained in all 20 patients,three order of bile duct was visualized in 19 patients.The visualization of the ultrasound contrast agent persisted more than 6 min.There was no side effect occurred during the procedure and no uncomfortable complaint after the procedure.②USC determined correctly in 18 cases.Compared with surgical or PTC findings,the accuracy of USC in determining obstructive levels was 90.0%(18/20),and the accuracy in determining the obstructive cause was 85.0%(17/20).Conclusions As a new and safe technique for cholangiography,USC is comparable to PTC in displaying the intrahepatic bite duct and determining the obstructive levels in patients with obstructive jaundice.

SELECTION OF CITATIONS
SEARCH DETAIL