Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Radiat Environ Biophys ; 62(1): 107-115, 2023 03.
Article in English | MEDLINE | ID: mdl-36526911

ABSTRACT

The aim of the present study was to investigate the effect of tumour motion on various imaging strategies as well as on treatment plan accuracy for lung stereotactic body radiotherapy treatment (SBRT) cases. The ExacTrac gating phantom and paraffin were used to investigate respiratory motion and represent a lung tumour, respectively. Four-dimensional computed tomography (4DCT) imaging was performed, while the phantom was moving sinusoidally with 4 s cycling time with three different amplitudes of 8, 16, and 24 mm. Reconstructions were done with maximum (MIP) and average intensity projection (AIP) methods. Comparisons of target density and volume were performed using two reconstruction techniques and references values. Volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) were planned based on reconstructed computed tomography (CT) sets, and it was examined how density variations affect the dose-volume histogram (DVH) parameters. 4D cone beam computed tomography (CBCT) was performed with the Elekta Versa HD linac imaging system before irradiation and compared with 3D CBCT. Thus, various combinations of 4DCT reconstruction methods and treatment alignment methods have been investigated. Point measurements as well as 2 and 3D dose measurements were done by optically stimulated luminescence (OSL), gafchromic films, and electronic portal imaging devices (EPIDs), respectively. The mean volume reduction was 7.8% for the AIP and 2.6% for the MIP method. The obtained Hounsfield Unit (HU) values were lower for AIP and higher for MIP when compared with the reference volume density. In DVH analysis, there were no statistical differences for D95%, D98%, and Dmean (p > 0.05). However, D2% was significantly affected by HU changes (p < 0.01). A positional variation was obtained up to 2 mm in moving direction when 4D CBCT was applied after 3D CBCT. Dosimetric measurements showed that the main part of the observed dose deviation was due to movement. In lung SBRT treatment plans, D2% doses differ significantly according to the reconstruction method. Additionally, it has been observed that setups based on 3D imaging can cause a positional error of up to 2 mm compared to setups based on 4D imaging. It is concluded that MIP has advantages over AIP in defining internal target volume (ITV) in lung SBRT applications. In addition, 4D CBCT and 3D EPID dosimetry are recommended for lung SBRT treatments.


Subject(s)
Lung Neoplasms , Radiosurgery , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Lung/radiation effects , Lung Neoplasms/radiotherapy , Four-Dimensional Computed Tomography/methods , Phantoms, Imaging
2.
J Appl Clin Med Phys ; 23(9): e13729, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35946855

ABSTRACT

PURPOSE: This study aimed to evaluate the feasibility of defining an in vivo dosimetry (IVD) protocol as a patient-specific quality assurance (PSQA) using the bead thermoluminescent dosimeters (TLDs) for point and 3D IVD during brachytherapy (BT) of gynecological (GYN) cancer using 60 Co high-dose-rate (HDR) source. METHODS: The 3D in vivo absorbed dose verification within the rectum and bladder as organs-at-risk was performed by bead TLDs for 30 GYN cancer patients. For rectal wall dosimetry, 80 TLDs were placed in axial arrangements around a rectal tube covered with a layer of gel. Ten beads were placed inside the Foley catheter to get the bladder-absorbed dose. Beads TLDs were localized and defined as control points in the treatment planning system (TPS) using CT images of the patients. Patients were planned and treated using the routine BT protocol. The experimentally obtained absorbed dose map of the rectal wall and the point dose of the bladder were compared to the TPSs predicted absorbed dose at these control points. RESULTS: Relative difference between TPS and TLDs results were -8.3% ± 19.5% and -7.2% ± 14.6% (1SD) for rectum- and bladder-absorbed dose, respectively. Gamma analysis was used to compare the calculated with the measured absorbed dose maps. Mean gamma passing rates of 84.1%, 90.8%, and 92.5% using the criteria of 3%/2 mm, 3%/3 mm, and 4%/2 mm were obtained, respectively. Eventually, a "considering level" of at least 85% as pass rate with 4%/2-mm criteria was recommended. CONCLUSIONS: A 3D IVD protocol employing bead TLDs was presented to measure absorbed doses delivered to the rectum and bladder during GYN HDR-BT as a reliable PSQA method. 3D rectal absorbed dose measurements were performed. Differences between experimentally measured and planned absorbed dose maps were presented in the form of a gamma index, which may be used as a warning for corrective action.


Subject(s)
Brachytherapy , In Vivo Dosimetry , Brachytherapy/methods , Cobalt Radioisotopes , Humans , Radiation Dosimeters , Radiometry/methods , Radiotherapy Dosage , Silicon Dioxide , Thermoluminescent Dosimetry/methods
SELECTION OF CITATIONS
SEARCH DETAIL