Results 1 - 20 de 835
Filter
1.
Article in English | MEDLINE | ID: mdl-39094608

ABSTRACT

The purpose of this study is to investigate whether deep learning-based sCT images enable accurate dose calculation in CK robotic stereotactic radiosurgery. A U-net convolutional neural network was trained using 2446 MR-CT pairs and used it to translate 551 MR images to sCT images for testing. The sCT of CK patient was encapsulated into a quality assurance (QA) validation phantom for dose verification. The CT value difference between CT and sCT was evaluated using mean absolute error (MAE) and the statistical significance of dose differences between CT and sCT was tested using the Wilcoxon signed rank test. For all CK patients, the MAE value of the whole brain region did not exceed 25HU. The percentage dose difference between CT and sCT was less than ±0.4% on GTV (D2(Gy), -0.29%, D95(Gy), -0.09%), PTV (D2(Gy), -0.25%, D95(Gy), -0.10%), and brainstem (max dose(Gy), 0.31%). The percentage dose difference between CT and sCT for most regions of interest (ROIs) was no more than ±0.04%. This study extended MR-based sCT prediction to CK robotic stereotactic radiosurgery, expanding the application scenarios of MR-only radiation therapy. The results demonstrated the remarkable accuracy of dose calculation on sCT for patients treated with CK robotic stereotactic radiosurgery.

2.
BMC Cancer ; 24(1): 936, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090564

ABSTRACT

PURPOSE: To evaluate the dosimetric characteristics of ZAP-X stereotactic radiosurgery (SRS) for single brain metastasis by comparing with two mature SRS platforms. METHODS: Thirteen patients with single brain metastasis treated with CyberKnife (CK) G4 were selected retrospectively. The prescription dose for the planning target volume (PTV) was 18-24 Gy for 1-3 fractions. The PTV volume ranged from 0.44 to 11.52 cc.Treatment plans of thirteen patients were replanned using the ZAP-X plan system and the Gamma Knife (GK) ICON plan system with the same prescription dose and organs at risk (OARs) constraints. The prescription dose of PTV was normalized to 70% for both ZAP-X and CK, while it was 50% for GK. The dosimetric parameters of three groups included the plan characteristics (CI, GI, GSI, beams, MUs, treatment time), PTV (D2, D95, D98, Dmin, Dmean, Coverage), brain tissue (volume of 100%-10% prescription dose irradiation V100%-V10%, Dmean) and other OARs (Dmax, Dmean),all of these were compared and evaluated. All data were read and analyzed with MIM Maestro. One-way ANOVA or a multisample Friedman rank sum test was performed, where p < 0.05 indicated significant differences. RESULTS: The CI of GK was significantly lower than that of ZAP-X and CK. Regarding the mean value, ZAP-X had a lower GI and higher GSI, but there was no significant difference among the three groups. The MUs of ZAP-X were significantly lower than those of CK, and the mean value of the treatment time of ZAP-X was significantly shorter than that of CK. For PTV, the D95, D98, and target coverage of CK were higher, while the mean of Dmin of GK was significantly lower than that of CK and ZAP-X. For brain tissue, ZAP-X showed a smaller volume from V100% to V20%; the statistical results of V60% and V50% showed a difference between ZAP-X and GK, while the V40% and V30% showed a significant difference between ZAP-X and the other two groups; V10% and Dmean indicated that GK was better. Excluding the Dmax of the brainstem, right optic nerve and optic chiasm, the mean value of all other OARs was less than 1 Gy. For the brainstem, GK and ZAP-X had better protection, especially at the maximum dose. CONCLUSION: For the SRS treating single brain metastasis, all three treatment devices, ZAP-X system, CyberKnife G4 system, and GammaKnife system, could meet clinical treatment requirements. The newly platform ZAP-X could provide a high-quality plan equivalent to or even better than CyberKnife and Gamma Knife, with ZAP-X presenting a certain dose advantage, especially with a more conformal dose distribution and better protection for brain tissue. As the ZAP-X systems get continuous improvements and upgrades, they may become a new SRS platform for the treatment of brain metastasis.


Subject(s)
Brain Neoplasms , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiosurgery/methods , Brain Neoplasms/secondary , Brain Neoplasms/radiotherapy , Brain Neoplasms/surgery , Male , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Female , Middle Aged , Radiometry , Aged , Adult , Organs at Risk/radiation effects
3.
Int Arch Otorhinolaryngol ; 28(3): e543-e551, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38974623

ABSTRACT

Introduction CyberKnife (CK) radiosurgery is a treatment strategy for vestibular schwannoma (VS). Objectives To evaluate hearing preservation (HP) after CK for VS. Data Synthesis The study was conducted following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement, and it was registered at the International Prospective Register of Systematic Reviews (PROSPERO, under number CRD42021250300). The inclusion criteria were based on the population, intervention, comparison, outcome, timing and study design (PICOTS) strategy: population - patients with VS; intervention - CK; Comparison - none; Outcome - serviceable HP defined by Gardner and Robertson as grades I or II, or by the American Academy of Otolaryngology and Head and Neck Surgery as classes A or B; timing - mean follow-up longer than 1 year; and study design - retrospective or prospective studies. The exclusion criteria were: studies not published in English; studies published before January 2000 and after October 2021; and studies only including patients with neurofibromatosis type 2 or submitted to a previous treatment. The PubMed/MEDLINE, EMBASE, Web of Science, Cochrane Library, LILACS, and IBECS databases were used and last searched on October 27th, 2021. Statistical heterogeneity was assessed using I 2 statistics. The appraisal checklist was used to assess the risk of bias in the included studies. A total of 222 studies were analyzed, and 13 were included in the synthesis, which represents 493 participants with serviceable hearing before intervention. The mean HP rate after CK using a random effects model was of 68% (95% confidence interval [95%CI]: 59-76%) at a mean follow-up of 42.96 months. Conclusion The longer follow-up period was associated with a lower HP rate after CK radiosurgery for VS in the qualitative synthesis.

4.
World J Oncol ; 15(4): 711-721, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38993252

ABSTRACT

Background: The aim of the study was to evaluate the efficacy of stereotactic body radiotherapy (SBRT) using the CyberKnife-M6 (CK-M6) with lung optimized treatment (LOT) module in patients with primary lung cancer and lung metastases. Methods: Forty-two lesions from 35 patients were treated between 2019 and 2022. Four-dimensional computed tomography images were obtained when the patients were in a free breathing modality. Tracking modality was selected prospectively according to the visibility of the target. The median prescribed dose was 48 Gy in four fractions (fx) (28 - 55 Gy/1- 7 fx). The median age was 68 years (47 - 82 years), and 43% of cases were adenocarcinoma. The median lesion size was 15 mm (6 - 36 mm). Results: Complete, partial and stable responses were obtained as 26%, 62%, and 9.5% at a median of 2 months (1 - 6 months), and 35.5%, 47.5% and 5% at the 12th month evaluation, respectively. Grade 3 and higher toxicity was not observed in any case. The mean and 2-year overall survival (OS) was 31.5 months and 54%, and the local recurrence-free survival (LRFS) was 29.6 months and 51%, respectively. In univariate analysis, target lesion type, complete response (CR), and higher esophagus maximum dose were favorable factors for OS and LRFS (P < 0.05). The CR at 12th month evaluation remained significant in multivariate analysis in terms of OS (hazard ratio = 8.602, 95% confidence interval: 1.05 - 70.01; P = 0.044). Conclusions: A mean LRFS of 29.6 months and OS of 31.5 months were obtained in patients with primary and metastatic lung cancer. With a median treatment time of 25 min, motion-managed strategy with CK-M6-LOT-based SBRT is an effective, safe, and comfortable treatment method for lung cancer.

5.
Platelets ; 35(1): 2380374, 2024 Dec.
Article in English | MEDLINE | ID: mdl-39041657

ABSTRACT

Dense-granule deficiency (DGD) is an inherited platelet disorder due to the absence of dense granules essential for activation of platelets in the event of vascular injury. Decreased platelet dense granules can be detected by electron microscopy, while other tests of hemostasis, including platelet function analyzer (PFA®) closure times, may be normal. The present case report describes a patient with a lifelong history of mucocutaneous bleeding and excessive hemorrhage with resection of vestibular Schwannoma. After hemostasis was obtained the case was aborted and the neurosurgeon noted bleeding resembled as if patient was on an antiplatelet drug. Subsequent hematologic workup revealed a severe platelet function disorder. There is a paucity of literature on management of intracranial neurosurgery in patients with inherited platelet disorders. Patients undergoing major surgical procedures often receive tranexamic acid (TXA), desmopressin, and/or human-leukocyte antigen (HLA)-matched platelet transfusions. We review the clinical management of intracranial tumor surgery, as well as Cyberknife radiosurgery, in our patient with DGD. After diagnosis was known, thoughtful hemostatic planning with empiric platelet transfusions and TXA prevented recurrent bleeding.


Platelet disorders that affect platelet function require high index of suspicion and special laboratory evaluation for diagnosis. We provide a case report of storage pool deficiency with management of bleeding in Schwannoma resection and radiosurgery. This case report adds to the limited literature to guide treatment of platelet function disorder in neurosurgery.


Subject(s)
Platelet Storage Pool Deficiency , Humans , Platelet Storage Pool Deficiency/complications , Male , Female , Middle Aged , Hemorrhage/etiology
6.
Radiat Oncol ; 19(1): 86, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38956685

ABSTRACT

PURPOSE: To apply an independent GPU-accelerated Monte Carlo (MC) dose verification for CyberKnife M6 with Iris collimator and evaluate the dose calculation accuracy of RayTracing (TPS-RT) algorithm and Monte Carlo (TPS-MC) algorithm in the Precision treatment planning system (TPS). METHODS: GPU-accelerated MC algorithm (ArcherQA-CK) was integrated into a commercial dose verification system, ArcherQA, to implement the patient-specific quality assurance in the CyberKnife M6 system. 30 clinical cases (10 cases in head, and 10 cases in chest, and 10 cases in abdomen) were collected in this study. For each case, three different dose calculation methods (TPS-MC, TPS-RT and ArcherQA-CK) were implemented based on the same treatment plan and compared with each other. For evaluation, the 3D global gamma analysis and dose parameters of the target volume and organs at risk (OARs) were analyzed comparatively. RESULTS: For gamma pass rates at the criterion of 2%/2 mm, the results were over 98.0% for TPS-MC vs.TPS-RT, TPS-MC vs. ArcherQA-CK and TPS-RT vs. ArcherQA-CK in head cases, 84.9% for TPS-MC vs.TPS-RT, 98.0% for TPS-MC vs. ArcherQA-CK and 83.3% for TPS-RT vs. ArcherQA-CK in chest cases, 98.2% for TPS-MC vs.TPS-RT, 99.4% for TPS-MC vs. ArcherQA-CK and 94.5% for TPS-RT vs. ArcherQA-CK in abdomen cases. For dose parameters of planning target volume (PTV) in chest cases, the deviations of TPS-RT vs. TPS-MC and ArcherQA-CK vs. TPS-MC had significant difference (P < 0.01), and the deviations of TPS-RT vs. TPS-MC and TPS-RT vs. ArcherQA-CK were similar (P > 0.05). ArcherQA-CK had less calculation time compared with TPS-MC (1.66 min vs. 65.11 min). CONCLUSIONS: Our proposed MC dose engine (ArcherQA-CK) has a high degree of consistency with the Precision TPS-MC algorithm, which can quickly identify the calculation errors of TPS-RT algorithm for some chest cases. ArcherQA-CK can provide accurate patient-specific quality assurance in clinical practice.


Subject(s)
Algorithms , Monte Carlo Method , Organs at Risk , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiosurgery/methods , Radiosurgery/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Neoplasms/surgery , Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Computer Graphics
7.
Cureus ; 16(5): e61432, 2024 May.
Article in English | MEDLINE | ID: mdl-38947568

ABSTRACT

PURPOSE: Stereotactic body radiation therapy (SBRT) has been established as a safe and effective treatment for prostate cancer. SBRT requires high accuracy to reduce treatment margins. Metal hip prostheses create artifacts that distort pelvic imaging and potentially decrease the accuracy of target/organ at risk (OAR) identification and radiation dose calculations. Data on the safety and efficacy of SBRT after hip replacement is limited. This single-institution study sought to evaluate the safety and local control following SBRT for prostate cancer in men with hip replacements. METHODS: 23 patients treated with localized prostate cancer and a history of pre-treatment hip replacement, treated with SBRT from 2007 to 2017 at MedStar Georgetown University Hospital were included in this retrospective analysis. Treatment was administered with the CyberKnife® (Accuray Incorporated, Sunnyvale, CA) at doses of 35 Gy or 36.25 Gy in 5 fractions. The targets and OARs were identified and contoured by a single experienced Radiation Oncologist (SPC). The adequacy of the CT and T2W MRI images for treatment planning was assessed with a three-point scale (good, adequate, or suboptimal). During treatment planning, care was taken to avoid treatment beams that directly traversed the hip prosthesis. Toxicities were recorded and scored using the Common Terminology Criteria for Adverse Events version 4.0 (CTCAE v.4.0). Local recurrence was confirmed by magnetic resonance imaging and/or prostate biopsy. RESULTS: The median follow-up was seven years. The patients were elderly (median age = 71 years) with a high rate of comorbidities (Charlson Comorbidity Index > 2 in 25%). Four patients had bilateral hip replacements. The majority of patients were low to intermediate risk per the D'Amico classification. Around 13% received upfront ADT. In total, 13 patients were treated with 35 Gy, and 10 were treated with 36.25 Gy. The rates of late > Grade 3 GU toxicity and > Grade 2 GI toxicity were 8.6% and 4.3%, respectively. There were no Grade 4 or 5 toxicities. Six patients (26%) developed a local recurrence at a median time of 7.5 years. Of these six patients, four had unilateral hip replacements and two had bilateral. Three underwent salvage cryotherapy and three received salvage ADT. CONCLUSIONS:  In the general population, high-grade toxicities and local recurrences are uncommon following prostate SBRT. However, in this cohort of patients with prior hip replacements, prostate SBRT had higher than expected rates of late toxicity and local recurrence. In the opinion of the authors, such patients should be counseled regarding an elevated risk of late toxicity and local recurrence with prostate SBRT. With its ultrasound guidance, brachytherapy would have the advantage of circumventing the need for MRI/CT-based imaging and thus may represent a preferable radiation alternative in this patient population. If these patients are treated with SBRT, they should be monitored closely for local recurrence so early salvage can be performed. We hope that recent advances in metal artifact reduction techniques and dose-calculation algorithms will improve future outcomes.

8.
Laryngoscope ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963255

ABSTRACT

OBJECTIVE: The incidence and risk factors for facial nerve dysfunction (FND) following CyberKnife® therapy for vestibular schwannoma (VS) remain poorly understood. This study investigates whether differential radiation doses to vulnerable segments of the facial nerve may be associated with FND outcomes. METHODS: Patients were identified who underwent CyberKnife® radiosurgery for VS at a single institution. Basic demographics, tumor characteristics, and facial nerve function were collected. Total radiation doses to tumor, internal auditory canal (IAC), and labyrinthine segment of facial nerve (LSFN) were evaluated. RESULTS: Six out of 64 patients experienced FND following CyberKnife® treatment for VS (9.38%, 6/64). Patients with FND were compared to those without FND (control). Of the 64 patients, complete radiation records were obtained for 30 patients (6 FND vs. 24 control). There were no significant differences in demographic or tumor characteristics between control and FND cohorts. More severe FND (HB ≥ 4) had significantly larger tumors (3.74 vs. 1.27 cm3, p = 0.037) with directionally decreased time to FND (3.50 vs. 33.5 months, p = 0.106) than patients with HB < 4, respectively. There were directionally, nonsignificant differences between maximum radiation doses to the LSFN (2492.4 vs. 2557.0 cGy, p = 0.121) and IAC (2877.3 vs. 2895.5 cGy, p = 0.824) between the control and FND cohorts, respectively. CONCLUSIONS: FND may represent an underrecognized sequelae of CyberKnife® radiosurgery for VS that can occur many months following treatment. Further studies are needed to elucidate the effect of differential radiation exposure to the facial nerve with FND following treatment. LEVEL OF EVIDENCE: III (Retrospective Cohort Study) Laryngoscope, 2024.

9.
Radiother Oncol ; : 110444, 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39067705

ABSTRACT

BACKGROUND: Radionecrosis is a common complication in radiation oncology, while mechanisms and risk factors have yet to be fully explored. We therefore conducted a systematic review to understand the pathogenesis and identify factors that significantly affect the development. METHODS: We performed a systematic literature search based on the PRISMA guidelines using PubMed, Ovid, and Web of Science databases. The complete search strategy can be found as a preregistered protocol on PROSPERO (CRD42023361662). RESULTS: We included 83 studies, most involving healthy animals (n = 72, 86.75 %). High doses of hemispherical irradiation of 30 Gy in rats and 50 Gy in mice led repeatedly to radionecrosis among different studies and set-ups. Higher dose and larger irradiated volume were associated with earlier onset. Fractionated schedules proved limited effectiveness in the prevention of radionecrosis. Distinct anatomical brain structures respond to irradiation in various ways. White matter appears to be more vulnerable than gray matter. Younger age, more evolved animal species, and genetic background were also significant factors, whereas sex was irrelevant. Only 13.25 % of the studies were performed on primary brain tumor bearing animals, no studies on brain metastases are currently available. CONCLUSION: This systematic review identified various factors that significantly affect the induction of radionecrosis. The current state of research neglects the utilization of animal models of brain tumors, even though patients with brain malignancies constitute the largest group receiving brain irradiation. This latter aspect should be primarily addressed when developing an experimental radionecrosis model for translational implementation.

10.
Cureus ; 16(6): e63421, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39077279

ABSTRACT

Steroids are commonly used for medical purposes. While hiccups are a recognized side effect of steroid therapy, we have not found any reports of hiccups interfering with the progress of radiotherapy. A case of dexamethasone (DEX)-induced hiccups (DIH) during CyberKnife radiotherapy (CKR) is presented. A 42-year-old man with neurofibromatosis type I had a history of malignant peripheral schwannomas originating in the right femur. We started to perform CKR with oral DEX at an increased dose of 4 mg/day for the recurrence of cranial metastasis and primary lesions. Severe hiccups developed four days after the increased DEX dose. DEX was stopped six days after CKR initiation, and the hiccups subsided over the next four days. However, the CKR procedure was not possible due to the patient's worsening swelling of the head and thigh lesions, which prevented the proper fit of the mesh face mask and body fixation device. Intravenous (IV) DEX 6.6 mg/day was initiated, which allowed the resumption of CKR due to reduced swelling of the lesions. The CKR was completed due to the absence of hiccups following the transition to IV DEX. DIH could occur even at a dosage of 4 mg/day when taken orally. Our case suggests the significance of recognizing DIH during radiotherapy. Switching the administration from oral to IV DEX may be an option for dealing with DIH.

11.
World J Clin Cases ; 12(16): 2729-2737, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38899289

ABSTRACT

BACKGROUND: Paragangliomas (PG) are rare neoplasms of neuroendocrine origin that tend to be highly vascularized, slow-growing, and usually sporadic. To date, common treatment options are surgical resection (SR), with or without radiation therapy (RT), and a watch-and-wait approach. AIM: To evaluate the local control and effectiveness of exclusive fractionated stereotactic RT (FSRT) treatment in unresectable PG (uPG). METHODS: We retrospectively evaluated patients with uPG (medically inoperable or refused SR) treated with FSRT with a Cyberknife System (Accuray Incorporated, Sunnyvale, California). Toxicity and initial efficacy were evaluated. RESULTS: From May 2009 to January 2023, 6 patients with a median age of 68 (range 20-84) were treated with FSRT. The median delivered dose was 21 Gy (range 20-30 Gy) at a median isodose line of 75.5% (range 70%-76%) in 4 fractions (range 3-5 fractions). The median volume was 13.6 mL (range 12.4-65.24 mL). The median cumulative biological effective dose and equivalent dose in 2-Gy fractions were 70 Gy and 37.10 Gy respectively. Site of origin involved were the timpa-nojugular glomus (4/6), temporal bone, and cervical spine. In 1 of the 6 patients, the follow-up was insufficient; 5 of 6 patients showed a 5-year overall survival and 5-year progression-free survival of 100%. We observed negligible toxicities during and after RT. The majority of patients showed stable symptoms during follow-up. Only 1 patient developed spine metastases. CONCLUSION: Our preliminary results on this small cohort of patients suggest that FSRT could be an effective and safe alternative to SR.

12.
J Clin Med ; 13(12)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38930121

ABSTRACT

Background/Objectives: Medulloblastoma is the most common malignant brain tumor in children. In recent decades, the therapeutic landscape has undergone significant changes, with stereotactic radiosurgery (SRS) emerging as a promising treatment for recurrent cases. Our study provides a comprehensive analysis of the long-term efficacy and safety of SRS in recurrent medulloblastomas across both pediatric and adult patients at a single institution. Methods: We retrospectively reviewed the clinical and radiological records of patients who underwent CyberKnife SRS for recurrent cranial medulloblastomas at our institution between 1998 and 2023. Follow-up data were available for 15 medulloblastomas in 10 patients. The cohort comprised eight pediatric patients (ages 3-18) and two adult patients (ages 19-75). The median age at the time of SRS was 13 years, the median tumor volume accounted for 1.9 cc, the median biologically equivalent dose (BED) was 126 Gy, and the single-fraction equivalent dose (SFED) was 18 Gy. The SRS was administered at 75% of the median isodose line. Results: Following a median follow-up of 39 months (range: 6-78), 53.3% of the medulloblastomas progressed, 13.3% regressed, and 33.3% remained stable. The 3-year local tumor control (LTC) rate for all medulloblastomas was 65%, with lower rates observed in the adult cohort (50%) and higher rates in pediatric patients (67%). The 3-year overall survival (OS) rate was 70%, with significantly higher rates in pediatric patients (75%) compared to adult patients (50%). The 3-year progression-free survival (PFS) rate was 58.3%, with higher rates in pediatric patients (60%) compared to adult patients (50%). Two pediatric patients developed radiation-induced edema, while two adult patients experienced radiation necrosis at the latest follow-up, with both adult patients passing away. Conclusions: Our study provides a complex perspective on the efficacy and safety of CyberKnife SRS in treating recurrent cranial medulloblastomas across pediatric and adult populations. The rarity of adverse radiation events (AREs) underscores the safety profile of SRS, reinforcing its role in enhancing treatment outcomes. The intricacies of symptomatic outcomes, intertwined with factors such as age, tumor location, and prior surgeries, emphasize the need for personalized treatment approaches. Our findings underscore the imperative for ongoing research and the development of more refined treatment strategies for recurrent medulloblastomas. Given the observed disparities in treatment outcomes, a more meticulous tailoring of treatment approaches becomes crucial.

13.
Front Oncol ; 14: 1333642, 2024.
Article in English | MEDLINE | ID: mdl-38939330

ABSTRACT

Purpose/Objectives: ZAP-X, a novel and dedicated radiosurgery (SRS) system, has recently emerged, while CyberKnife has solidified its position as a versatile solution for SRS and stereotactic body radiation therapy over the past two decades. This study aims to compare the dosimetric performance and delivery efficiency of ZAP-X and CyberKnife in treating brain metastases of varying target sizes, employing circular collimation. Methods and materials: Twenty-three patients, encompassing a total of 47 brain metastases, were included in the creation of comparative plans of ZAP-X and CyberKnife for analysis. The comparative plans were generated to achieve identical prescription doses for the targets, while adhering to the same dose constraints for organs at risk (OAR). The prescription isodose percentage was optimized within the range of 97-100% for each plan to ensure effective target-volume coverage. To assess plan quality, indices such as conformity, homogeneity, and gradient (CI, HI, and GI) were computed, along with the reporting of total brain volumes receiving 12Gy and 10Gy. Estimated treatment time and monitor units (MUs) were compared between the two modalities in evaluating delivery efficiency. Results: Overall, CyberKnife achieved better CI and HI, while ZAP-X exhibited better GI and a smaller irradiated volume for the normal brain. The superiority of CyberKnife's plan conformity was more pronounced for target size less than 1 cc and greater than 10 cc. Conversely, the advantage of ZAP-X's plan dose gradient was more notable for target sizes under 10 cc. The homogeneity of ZAP-X plans, employing multiple isocenters, displayed a strong correlation with the target's shape and the planner's experience in placing isocenters. Generally, the estimated treatment time was similar between the two modalities, and the delivery efficiency was significantly impacted by the chosen collimation sizes for both modalities. Conclusion: This study demonstrates that, within the range of target sizes within the patient cohort, plans generated by ZAP-X and CyberKnife exhibit comparable plan quality and delivery efficiency. At present, with the current platform of the two modalities, CyberKnife outperforms ZAP-X in terms of conformity and homogeneity, while ZAP-X tends to produce plans with a more rapid dose falloff.

14.
Phys Eng Sci Med ; 2024 May 29.
Article in English | MEDLINE | ID: mdl-38809365

ABSTRACT

Stereotactic body radiation therapy (SBRT) has been increasingly used for the ablation of liver tumours. CyberKnife and proton beam therapy (PBT) are two advanced treatment technologies suitable to deliver SBRT with high dose conformity and steep dose gradients. However, there is very limited data comparing the dosimetric characteristics of CyberKnife to PBT for liver SBRT. PBT and CyberKnife plans were retrospectively generated using 4DCT datasets of ten patients who were previously treated for hepatocellular carcinoma (HCC, N = 5) and liver metastasis (N = 5). Dose volume histogram data was assessed and compared against selected criteria; given a dose prescription of 54 Gy in 3 fractions for liver metastases and 45 Gy in 3 fractions for HCC, with previously published consensus-based normal tissue dose constraints. Comparison of evaluation parameters showed a statistically significant difference for target volume coverage and liver, lungs and spinal cord (p < 0.05) dose, while chest wall and skin did not indicate a significant difference between the two modalities. A number of optimal normal tissue constraints was violated by both the CyberKnife and proton plans for the same patients due to proximity of tumour to chest wall. PBT resulted in greater organ sparing, the extent of which was mainly dependent on tumour location. Tumours located on the liver periphery experienced the largest increase in organ sparing. Organ sparing for CyberKnife was comparable with PBT for small target volumes.

15.
J Appl Clin Med Phys ; : e14404, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38803034

ABSTRACT

BACKGROUND AND PURPOSE: This study aimed to compare the dosimetric attributes of two multi-leaf collimator based techniques, HyperArc and Incise CyberKnife, in the treatment of brain metastases. MATERIAL AND METHODS: 17 cases of brain metastases were selected including 6 patients of single lesion and 11 patients of multiple lesions. Treatment plans of HyperArc and CyberKnife were designed in Eclipse 15.5 and Precision 1.0, respectively, and transferred to Velocity 3.2 for comparison. RESULTS: HyperArc plans provided superior Conformity Index (0.91 ± 0.06 vs. 0.77 ± 0.07, p < 0.01) with reduced dose distribution in organs at risk (Dmax, p < 0.05) and lower normal tissue exposure (V4Gy-V20Gy, p < 0.05) in contrast to CyberKnife plans, although the Gradient Indexes were similar. CyberKnife plans showed higher Homogeneity Index (1.54 ± 0.17 vs. 1.39 ± 0.09, p < 0.05) and increased D2% and D50% in the target (p < 0.05). Additionally, HyperArc plans had significantly fewer Monitor Units (MUs) and beam-on time (p < 0.01). CONCLUSION: HyperArc plans demonstrated superior performance compared with MLC-based CyberKnife plans in terms of conformity and the sparing of critical organs and normal tissues, although no significant difference in GI outcomes was noted. Conversely, CyberKnife plans achieved a higher target dose and HI. The study suggests that HyperArc is more efficient and particularly suitable for treating larger lesions in brain metastases.

16.
J Appl Clin Med Phys ; : e14352, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696697

ABSTRACT

PURPOSE: To design a patient specific quality assurance (PSQA) process for the CyberKnife Synchrony system and quantify its dosimetric accuracy using a motion platform driven by patient tumor traces with rotation. METHODS: The CyberKnife Synchrony system was evaluated using a motion platform (MODUSQA) and a SRS MapCHECK phantom. The platform was programed to move in the superior-inferior (SI) direction based on tumor traces. The detector array housed by the StereoPhan was placed on the platform. Extra rotational angles in pitch (head down, 4.0° ± 0.15° or 1.2° ± 0.1°) were added to the moving phantom to examine robot capability of angle correction during delivery. A total of 15 Synchrony patients were performed SBRT PSQA on the moving phantom. All the results were benchmarked by the PSQA results based on static phantom. RESULTS: For smaller pitch angles, the mean gamma passing rates were 99.75% ± 0.87%, 98.63% ± 2.05%, and 93.11% ± 5.52%, for 3%/1 mm, 2%/1 mm, and 1%/1 mm, respectively. Large discrepancy in the passing rates was observed for different pitch angles due to limited angle correction by the robot. For larger pitch angles, the corresponding mean passing rates were dropped to 93.00% ± 10.91%, 88.05% ± 14.93%, and 80.38% ± 17.40%. When comparing with the static phantom, no significant statistic difference was observed for smaller pitch angles (p = 0.1 for 3%/1 mm), whereas a larger statistic difference was observed for larger pitch angles (p < 0.02 for all criteria). All the gamma passing rates were improved, if applying shift and rotation correction. CONCLUSIONS: The significance of this work is that it is the first study to benchmark PSQA for the CyberKnife Synchrony system using realistically moving phantoms with rotation. With reasonable delivery time, we found it may be feasible to perform PSQA for Synchrony patients with a realistic breathing pattern.

17.
Cureus ; 16(3): e55729, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38586683

ABSTRACT

BACKGROUND: Androgen deprivation therapy (ADT) improves local cancer control in unfavorable localized prostate cancer treated with radiotherapy. ADT is known to cause hormonally related symptoms that resolve with testosterone recovery. Hot flashes are particularly burdensome. This study sought to evaluate the timeline of hot flashes following short-course ADT and stereotactic body radiotherapy (SBRT) as well as its relationship with testosterone recovery. METHODS: Institutional IRB approval was obtained for this retrospective review of prospectively collected data (IRB#: 2009-510). ADT was initiated three months prior to the start of SBRT. Hot flashes were self-reported via question 13a of the Expanded Prostate Index Composite (EPIC)-26 prior to ADT initiation, the first day of robotic SBRT, and at each follow-up (one, three, six, nine, 12, 18, 24, and 36 months). The responses were grouped into three relevant categories (no problem, very small-small problem, and moderate-big problem). Scores were transformed to a 0-100 scale with higher scores reflecting less bother. Testosterone levels were measured at each follow-up. RESULTS: From 2007 to 2010, 122 localized prostate cancer patients (nine low-, 64 intermediate-, and 49 high-risk according to the D'Amico classification) at a median age of 72 years (range 54.5-88.3) were treated with short course ADT (three to six months) and SBRT (35-36.25 Gy) at Georgetown University Hospital. Thirty-two percent were Black and 27% were obese. Seventy-seven percent of patients received three months of ADT. At baseline, 2% of men experienced hot flashes that were a "moderate to big problem" and that proportion peaked at the start of SBRT (45%) before returning to baseline (2%) nine months post-SBRT with a cumulative incidence of 52.4%. The median baseline EPIC-26 hot flash score of 94 declined to 50 at the start of SBRT but this returned to baseline (92) by six months post SBRT. These changes were both statistically and clinically significant (MID = 9.5083, p<0.01). Testosterone recovery (> 230 ng/dL) occurred in approximately 70% of patients by 12 months post SBRT. Resolution of hot flashes correlated with testosterone recovery. CONCLUSION: Bothersome hot flashes occur in greater than 50% of men treated with neoadjuvant ADT. Resolution of hot flashes occurs in the majority of patients within one year after treatment. Reassurance of the temporary nature of hot flashes may assist in reducing patient anxiety. Measuring testosterone levels at follow-up visits may allow for anticipatory counseling that may limit the associated bother.

18.
Ocul Oncol Pathol ; 10(1): 25-31, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38645736

ABSTRACT

Introduction: Uveal melanoma is the most common primary intraocular malignancy in adults, affecting primarily the choroid of the eye. Plaque brachytherapy is the most common procedure for the treatment of small choroidal melanoma, especially in posteriorly located tumors. However, modern radiotherapy techniques, such as CyberKnife or Gamma knife stereotactic radiosurgery (SRS) and proton beam radiotherapy, have shown better results in tumor control and eye retention. Recent studies have indicated that SRS is a promising non-invasive, single-session treatment option, with most studies reporting the best outcomes when using ≥21-22 Gy. However, there is no consistent protocol for managing this pathology using CyberKnife, not only in terms of dose but also fractions. Case Presentations: Here, we report the first case series of patients (n = 4, age range 38-64 years, median age 52.5 years) with choroidal UM in Central America who were treated with CyberKnife SRS (22 Gy in one session). During the follow-up (range 25-29 months, median 27.5 months), a 100% control rate with no systemic metastatic disease has been achieved. We found a statistically significant reduction in the largest basal diameter at 24 months for all tumors. However, visual acuity has progressively decreased in most patients. Notably, two of our patients developed radiation maculopathy, and the other two developed radiation retinopathy after SRS. Conclusions: Our findings suggest that future studies should evaluate the use of different prophylactic therapies to prevent the development of side effects. The clinical management of toxicities presented in our report can serve as a reference in the clinical practice of other centers. Our report supports the growing body of evidence showing that CyberKnife radiosurgery is a safe and effective therapeutic option for the treatment of UM.

19.
Radiol Case Rep ; 19(7): 2654-2662, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38645955

ABSTRACT

Stereotactic radiosurgery (SRS) is an effective treatment for vestibular schwannomas, offering high rates of tumor control and low neurological risks. Long-term complications of SRS are not fully understood, with several cases of malignant transformation reported in the literature. We report the case of a 50-year-old female with no prior history of neurofibromatosis who presented in 2013 with MRI evidence of a benign vestibular schwannoma. Despite treatment with CyberKnife SRS, she presented 6 years later with new onset neurologic symptoms. Further investigation showed stable lesion size with increasing vasogenic edema and a new area of enhancement in the brainstem, suspicious for malignant transformation. Subsequent treatment with partial craniectomy and histopathologic analysis was consistent with a malignant peripheral nerve sheath tumor diagnosis. Our case adds to a series of 24 similar cases in the literature, details of which have been summarized in our study. Overall, findings support the need for lifelong surveillance following SRS treatment of benign vestibular schwannomas. Patients should be educated on the potential risk of this complication, and clinicians must maintain a high level of suspicion for potential radiation-induced malignancy during the patient's clinical course.

20.
Cureus ; 16(3): e56877, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38659529

ABSTRACT

This case report describes the treatment of a recurrent T2 vertebral hemangioma in a 46-year-old man who had prior decompression and fusion surgery. Despite initial stability, the patient developed worsening symptoms, leading to a comprehensive approach involving embolization, microscopic excision, and posterior fixation. Recurrence prompted the choice of Stereotactic Body Radiotherapy (SBRT) over redo surgery. Administered with 30 Gy in five fractions, SBRT significantly reduced hemangioma size and resolved neurological symptoms. The case highlights the effectiveness of hypofractionated SBRT as a promising intervention for aggressive vertebral hemangiomas.