Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 909
Filter
1.
Radiography (Lond) ; 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39244455

ABSTRACT

OBJECTIVES: To review and evaluate available literature on spectral computed tomography (SCT) bone mineral density (BMD) measurement in adult thoracolumbar vertebrae of unenhanced images compared to quantitative computed tomography (QCT), to understand its current clinical utility. KEY FINDINGS: Keyword searches in four databases identified four cross-sectional studies which acquired an SCT BMD measurement in thoracolumbar vertebrae and compared this respectively to QCT, which were then critically appraised using the AXIS tool for cross-sectional studies. 862 vertebrae were measured between T10-S1 in 368 patients. Three studies demonstrated a statistically significant correlation between SCT and QCT for the measurement of Hydroxyapatite (HAP) and calcium (r = 0.86-0.96). One study demonstrated a diagnostic accuracy of 96% using a receiver operating curve. CONCLUSIONS: SCT measurements of HAP and calcium in the lumbar vertebrae are comparable to QCT for patients with no additional pathology present. However, further research is required to evaluate diagnostic accuracy before clinical application. IMPLICATIONS FOR PRACTICE: SCT BMD measurement has the potential to be developed as a screening tool for osteoporosis within the fracture liaison service (FLS). This could aid in the identification of patients with osteoporosis and address the current treatment gap. Nonetheless, many factors must be considered for this application including staff training, radiation protection and patient engagement with the screening programme.

2.
J Public Health Dent ; 2024 Sep 07.
Article in English | MEDLINE | ID: mdl-39243208

ABSTRACT

OBJECTIVES: To assess the relationships between longitudinal fluoride intakes and bone densitometry outcomes in young adults. METHODS: Data were analyzed from the Iowa Fluoride Study and Iowa Bone Development Study, which followed 1,882 infants from birth in 1992. Daily fluoride intakes were assessed using detailed questionnaires sent every 1.5-6 months, and multi-row detector computed tomography (MDCT) scans of distal tibia were obtained from 330 participants aged 23 years. Sex-specific bivariate and multivariable associations with MDCT outcomes were examined using linear regression. Because of the multiple statistical analyses being conducted, p-values < 0.01 were considered statistically significant. RESULTS: In fully adjusted analyses, no statistically significant (p < 0.01) or suggestive (0.01 < p < 0.05) associations were found between period-specific or cumulative fluoride intake and bone measures for either sex, although there were suggestive positive relationships in unadjusted analyses. CONCLUSIONS: Longitudinal fluoride intakes had little association with bone measures at age 23. As there were no adverse effects from fluoride intake on bone health in young adults, results support the continued use of fluorides, particularly community water fluoridation is the most cost-effective method of dental caries prevention.

3.
J Biomed Opt ; 29(Suppl 3): S33306, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39247899

ABSTRACT

Significance: The arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green-based dynamic contrast-enhanced fluorescence imaging (DCE-FI). Aim: We evaluate the impact of the AIF on perfusion assessment through DCE-FI. Approach: A total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF. Results: Individual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate ( k ep ), maximum intensity ( I max ), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant ( K trans ), and time to peak. Conclusions: Individual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.


Subject(s)
Indocyanine Green , Optical Imaging , Humans , Optical Imaging/methods , Indocyanine Green/chemistry , Indocyanine Green/pharmacokinetics , Female , Middle Aged , Aged , Male , Contrast Media/chemistry , Adult , Arteries/diagnostic imaging , Perfusion Imaging/methods , Computer Simulation
4.
Article in English | MEDLINE | ID: mdl-39223341

ABSTRACT

Asphyxia as a cause of death poses a diagnostic challenge in forensic medicine due to both the diversity of underlying mechanisms, and lack of specific markers. Acute emphysema or acute alveolar dilation have long been debated as potential findings in these asphyxia cases. To further explore the supplementary findings in our forensic asphyxia cases, this study applied lung densitometry to pulmonary postmortem computed tomography (PMCT) data. Twenty asphyxia cases (including hanging (n = 9), manual strangulation (n = 4), ligature strangulation (n = 1), smothering (n = 3), and choking (n = 3)) and 21 matched control cases were analysed using lung densitometry parameters - specifically quantification of low attenuation areas (LAA) and the 15th percentile point of lung density (Perc15). Our data revealed statistically significantly higher lung % volume falling within LAA at -950HU (p = 0.04) and - 910HU (p = 0.043) in the asphyxia cases compared to matched controls. The Perc15 values observed were trending towards a lower attenuation corresponding to a lower density in the asphyxia group, although this result was not statistically significant (p = 0.13). A subgroup analysis highlighted potential differences within the asphyxia categories, notably, higher Perc15 values were observed in the choking cases. In conclusion the results from the study support the existing evidence of low pulmonary density as a potential finding in asphyxia cases and demonstrate the potential of applying lung densitometry on pulmonary postmortem computed tomography data.

5.
An. bras. dermatol ; 99(4): 513-519, Jul.-Aug. 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1563694

ABSTRACT

Abstract Objective To evaluate the effects of rosacea on ocular surface changes such as alterations in dry eye parameters, corneal densitometry, and aberrations, in comparison with healthy controls. Methods A total of 88 eyes of 44 patients diagnosed with rosacea and 88 eyes of 44 healthy controls were enrolled in this cross-sectional study. All participants underwent a comprehensive dermatologic and ophthalmic examination and Tear Break-Up Time (TBUT) and Schirmer-1 tests were performed. The rosacea subtype and Demodex count and OSDI scores of all participants were recorded. Corneal topographic, densitometric, and aberrometric measurements were obtained using the Scheimpflug imaging system. Results The mean age of the 44 patients was 41.2 ± 11.0 years of whom 31 (70.5%) were female. The mean TBUT and Schirmer-1 test values were significantly decreased and OSDI scores were significantly increased in the rosacea group compared to healthy controls (p < 0.01 for all). The most common subtype of rosacea was erythematotelangiectatic rosacea (70.4%). The severity grading of rosacea revealed that 18 (40.9%) patients had moderate erythema. The median (min-max) Demodex count was 14.0 (0-120) and the disease duration was 24.0 (5-360) months. The comparison of the corneal densitometry values revealed that the densitometry measurements in all concentric zones, especially in central and posterior zones were higher in rosacea patients. Corneal aberrometric values in the posterior surface were also lower in the rosacea group compared to healthy controls. The topographic anterior chamber values were significantly lower in the rosacea group. Study limitations Relatively small sample size, variable time interval to hospital admission, and lack of follow-up data are among the limitations of the study. Future studies with larger sample sizes may also enlighten the mechanisms of controversial anterior segment findings by evaluating rosacea patients who have uveitis and those who do not. Conclusion Given the fact that ocular signs may precede cutaneous disease, rosacea is frequently underrecognized by ophthalmologists. Therefore, a comprehensive examination of the ocular surface and assessment of the anterior segment is essential. The main priority of the ophthalmologist is to treat meibomian gland dysfunction and Demodex infection to prevent undesired ocular outcomes.

6.
J Clin Imaging Sci ; 14: 26, 2024.
Article in English | MEDLINE | ID: mdl-39108316

ABSTRACT

Objectives: Although sarcopenia is recognized as one of the risk factors for increased morbidity after resection for colorectal cancer, the question of the most appropriate way to identify and quantify it is still unresolved. Material and Methods: This is a retrospective unicentric study following patients undergoing elective resection of the rectum for carcinoma with available staging computed tomography (CT) of the trunk. Psoas muscle density (PMD) and its area relative to patient height psoas muscle index (PMI) at the level of inferior vertebral end plate of third lumbar vertebra (L3) were assessed using an initial staging CT scan of the trunk. Post-operative complications, evaluated according to the Clavien-Dindo classification, and blood samples on post-operative days (POD) 3 and 5 were also recorded in the study population. Patients were divided into groups with complicated and uncomplicated post-operative course, and observed parameters were then statistically compared. Results: The correlation of PMI values with the development of post-operative complications was not confirmed in a data set of 206 patients. PMD values were found to be borderline statistically significant in patients with complicated post-operative course, while in the group of patients with severe complications (Clavien-Dindo III-IV), there was no statistically significant difference in PMI or PMD values. The same results were obtained when comparing patients with anastomotic leak (AL). It was confirmed that operations on the lower rectum are riskier for the development of post-operative complications. The secondary objective of our study regarding serum C-reactive protein (CRP) levels of 3rd and 5th POD gave us the answer in the form of cutoff values of 115.7 mg/L (3rd POD) and 76 mg/L (5th POD). Conclusion: PMD appears to be a promising tool for predicting post-operative morbidity in patients after rectal resection, but a clear consensus on the method of measurement, interpretation of results and cutoff values is needed. Lower rectal resections are burdened with a higher risk of post-operative complications, especially AL. Monitoring of CRP levels remains an important marker in the prediction of AL due to its negative predictive value.

7.
Eur Radiol Exp ; 8(1): 86, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090457

ABSTRACT

BACKGROUND: To investigate the reproducibility of automated volumetric bone mineral density (vBMD) measurements from routine thoracoabdominal computed tomography (CT) assessed with segmentations by a convolutional neural network and automated correction of contrast phases, on diverse scanners, with scanner-specific asynchronous or scanner-agnostic calibrations. METHODS: We obtained 679 observations from 278 CT scans in 121 patients (77 males, 63.6%) studied from 04/2019 to 06/2020. Observations consisted of two vBMD measurements from Δdifferent reconstruction kernels (n = 169), Δcontrast phases (n = 133), scan Δsessions (n = 123), Δscanners (n = 63), or Δall of the aforementioned (n = 20), and observations lacking scanner-specific calibration (n = 171). Precision was assessed using root-mean-square error (RMSE) and root-mean-square coefficient of variation (RMSCV). Cross-measurement agreement was assessed using Bland-Altman plots; outliers within 95% confidence interval of the limits of agreement were reviewed. RESULTS: Repeated measurements from Δdifferent reconstruction kernels were highly precise (RMSE 3.0 mg/cm3; RMSCV 1.3%), even for consecutive scans with different Δcontrast phases (RMSCV 2.9%). Measurements from different Δscan sessions or Δscanners showed decreased precision (RMSCV 4.7% and 4.9%, respectively). Plot-review identified 12 outliers from different scan Δsessions, with signs of hydropic decompensation. Observations with Δall differences showed decreased precision compared to those lacking scanner-specific calibration (RMSCV 5.9 and 3.7, respectively). CONCLUSION: Automatic vBMD assessment from routine CT is precise across varying setups, when calibrated appropriately. Low precision was found in patients with signs of new or worsening hydropic decompensation, what should be considered an exclusion criterion for both opportunistic and dedicated quantitative CT. RELEVANCE STATEMENT: Automated CT-based vBMD measurements are precise in various scenarios, including cross-session and cross-scanner settings, and may therefore facilitate opportunistic screening for osteoporosis and surveillance of BMD in patients undergoing routine clinical CT scans. KEY POINTS: Artificial intelligence-based tools facilitate BMD measurements in routine clinical CT datasets. Automated BMD measurements are highly reproducible in various settings. Reliable, automated opportunistic osteoporosis diagnostics allow for large-scale application.


Subject(s)
Bone Density , Tomography, X-Ray Computed , Humans , Male , Tomography, X-Ray Computed/methods , Female , Reproducibility of Results , Middle Aged , Aged , Adult , Aged, 80 and over , Retrospective Studies , Neural Networks, Computer
8.
BMC Chem ; 18(1): 157, 2024 Aug 27.
Article in English | MEDLINE | ID: mdl-39192312

ABSTRACT

Ipratropium bromide (IPR) and fenoterol hydrobromide (FEN) have recently been combined in a promising inhaler to treat two prevalent inflammatory illnesses of the airways: bronchial asthma and chronic obstructive pulmonary disease (COPD). The necessity for a single, sensitive, and trustworthy analytical approach to cover the diverse and necessary tests of in-vitro and in-vivo studies is greatly grown with the rising production of new fixed combinations. Two novel, selective and environmentally friendly LC techniques were developed in order to guarantee precise measurement of IPR and FEN in their challenging formulation. The initial technique involved high-performance thin-layer chromatography (HPTLC) in conjunction with densitometric quantification. Chromatographic separation was attained on HPTLC plates utilizing ethyl acetate - ethanol - acetic acid (5.0:5.0:0.1, by volume) as a developing system. Densitometric quantification of the separated bands was carried out at 220.0 nm over concentration ranges of 0.50-15.0 µg/band for IPR and 0.50-12.0 µg/band for FEN. High-performance liquid chromatography (HPLC) paired with diode array detection (DAD) was the core of the second technique. The optimized separation was achieved on a Zorbax SB C18 (150 × 4.6 mm, 5 µm) column with a combination of 10.0 mM potassium dihydrogen orthophosphate, pH 5.0 ± 0.1, adjusted with o-phosphoric acid and methanol (70:30, v/v) as the mobile phase and pumped at flow rate of 1.0 mL/min. The peaks were monitored at 220.0 nm using diode array detection, achieving linearity range of 5.0-200.0 µg/mL for both drugs. The ICH criteria have been verified and both methods have been confirmed to be valid, and successfully applied for assay the cited drugs in the Atrovent® comp HFA metered dose inhaler as well as delivered dose uniformity testing of the final product. Finally, whiteness appraisal and several state-of-the-art green evaluation metrics were applied to evaluate the sustainability of the proposed methods. The suggested approaches produced promising results and are the first simple and sustainable methodologies for the simultaneous quantification of both drugs in different real samples, all of which strongly suggest their application in quality control laboratories.

9.
J Clin Densitom ; 27(4): 101528, 2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39213723

ABSTRACT

PURPOSE: People with spinal cord injury (SCI) experience a considerable loss of bone after the injury. Lumbar spine (LS) bone mineral density (BMD) has been reported to be within the normal range, or even higher when assessed with DXA, in people with SCI; hence, it has been hypothesized that sources of error may spuriously increase LS BMD. The aim of this study was to describe the frequency of potential sources of error that may alter LS BMD measurement in a cohort of individuals with chronic SCI at baseline and over a 2-year period. METHODS: We analyzed baseline and 2-year follow up DXA scans (Hologic Discovery QDR 4500, Hologic Inc., MA, USA) previously performed from a cohort of males and females with chronic SCI. Two physicians independently reviewed each scan, commented on whether the scan was appropriate for BMD analysis, should be re-analyzed, or be removed from the dataset, and reported on the presence of potential sources of error in LS BMD measurement. RESULTS: We reviewed 115 lumbar spine DXA scans from 58 participants, and 107 (93.0 %) scans from 52 participants presented at least one potential source of error. At baseline, the average number of potential sources of error per scan was 5.5 ± 1.7 and 5.7 ± 1.5 according to rater 1 and rater 2, respectively. Follow-up scans presented an average of 5.6 ± 1.6 and 5.7 ± 1.4 potential sources of error according to rater 1 and rater 2, respectively. Facet sclerosis, osteophytes and difficulty in detecting bone edges were the most prevalent sources of error. CONCLUSION: The high frequency of potential sources of error is consistent with current recommendations against the use of LS BMD for fracture risk assessment in people with SCI.

10.
Eur J Ophthalmol ; : 11206721241267360, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39147728

ABSTRACT

PURPOSE: To describe and compare corneal densitometry, subjective refraction, visual acuity, and corneal higher order aberrations (HOA) after corneal refractive surgery using either alcohol-assisted photorefractive keratectomy (aaPRK) or single-step transepithelial PRK (tPRK). METHODS: We conducted a retrospective and observational study. We analyzed 120 right eyes from 120 healthy consecutive myopic patients who underwent aaPRK or tPRK to correct myopia of up to 6 diopters and astigmatism of up to 2 diopters. The WaveLight EX500 excimer laser (Alcon Laboratories, Inc.) was used in all cases. Visual acuity, subjective refraction, and Pentacam AXL® measurements were performed at the preoperative visit and at 6-months follow-up visit. Pentacam AXL® software was used to assess corneal optical density in various annuli for different corneal depths and anterior corneal HOA (6 mm area of analysis). RESULTS: Preoperative spherical equivalent values were similar between groups preoperatively (-3.07 ± 1.52 and -3.38 ± 1.46 in the aaPRK and tPRK groups, respectively). There were no statistically significant differences in visual acuity and postoperative refraction between groups. Postoperative corneal densitometry did not show statistically significant differences in any of the areas studied and both surgical procedures obtained similar results. However, analysis of HOA showed statistically significant differences between the techniques (1.42 ± 0.39 and 1.80 ± 0.62 for the aaPRK and tPRK groups, respectively; p = 0.000). CONCLUSIONS: Both aaPRK and single-step tPRK gave comparable visual, refractive, and corneal density outcomes. Some differences were observed in HOA but were not clinically relevant.

11.
Pharmaceuticals (Basel) ; 17(8)2024 Jul 29.
Article in English | MEDLINE | ID: mdl-39204107

ABSTRACT

A cost-effective, selective, sensitive, and operational TLC-densitometric approach has been adapted for the concurrent assay of Hydroxyzine Hydrochloride (HYX), Ephedrine Hydrochloride (EPH), and Theophylline (THP) in their pure powder and pharmaceutical forms. In the innovative TLC-densitometric approach, HYX, EPH, and THP were efficaciously separated and quantified on a 60F254 silica gel stationary phase with chloroform-ammonium acetate buffer (9.5:0.5, v/v) adjusted to pH 6.5 using ammonia solution as a mobile liquid system and UV detection at 220 nm. The novel TLC method validation has been performed in line with the international conference for harmonization (ICH) standards and has been effectively used for the estimation of the researched medicines in their pharmaceutical formulations without intervention from excipients. Additionally, parameters affecting the chromatographic analysis have been investigated. The new TLC approach's functionality and greenness were appraised using three modern and automated tools, namely the Blue Applicability Grade Index (BAGI), the Analytical Greenness metric (AGREE), and the Green Analytical Procedure Index (GAPI) tools. In short, the greenness characteristics were not achieved as a result of using mandatory, non-ecofriendly solvents such as ammonia and chloroform. On the contrary, the applicability and usefulness of the novel TLC approach were attained via concurrent estimation for the three drugs using simple and straightforward procedures. Moreover, the novel TLC method outperforms previously published HPLC ones in terms of the short run time per sample and moderate pH value for the liquid system. According to the conclusions of comparisons with previously recorded TLC methods, our novel HPTLC method has the highest AGREE score, so it is the greenest HPTLC strategy. Moreover, its functionality and applicability are very appropriate because of the simultaneous assessment of three drugs in one TLC run. Furthermore, no tedious and complicated extraction and evaporation processes are prerequisites.

12.
Article in English | MEDLINE | ID: mdl-39206082

ABSTRACT

Background: Pseudoexfoliation syndrome (PES) is an age-related systemic condition that predominantly affects ocular structures and is characterized by the deposition of material on the lens, ciliary body, zonules, corneal endothelium, iris, and pupillary margin. We compared the corneal endothelial morphology, anterior segment parameters, corneal densitometry, and corneal topographic characteristics between the clinically affected and apparently normal fellow eyes of patients with clinically unilateral PES. Methods: This was a comparative, cross-sectional study of 34 patients with clinically unilateral PES. The anterior segment was examined using a Scheimpflug imaging system, and the corneal endothelium was assessed using a noncontact specular microscope. Corneal endothelial cell density, polymegathism, and pleomorphism were assessed using the specular microscope. Furthermore, the Scheimpflug camera was used to measure the corneal power of the flat and steep axis, mean corneal power, maximum keratometry, anterior chamber angle, anterior chamber depth, anterior chamber volume, corneal volume, and the corneal thickness at the apex point, center of the pupil, and the thinnest point. Corneal densitometry was evaluated at two concentric zones (0-2 mm and 0-12 mm). Results: In total, 68 eyes from 34 patients were ultimately included in the study. The mean (standard deviation) age of the patients was 73.38 (8.75) years (range: 50-87 years). Among the included patients, 17 (50%) were male and 17 (50%) were female. The anterior segment parameters did not significantly differ between eyes with PES and their clinically unaffected fellow eyes (all P > 0.05). Similarly, no statistically significant difference was observed in corneal endothelial morphology (all P > 0.05). Conclusions: Our measured parameters do not differ between the clinically affected eye and the clinically unaffected fellow eye. This supports the theory that PES is a bilateral disorder. Considering the variety of complications associated with PES, bilateral involvement should be assumed in the clinical and surgical management of patients with clinically unilateral PES. In the future, new research could increase our understanding of this syndrome.

13.
Article in English, Spanish | MEDLINE | ID: mdl-39128695

ABSTRACT

Vertebral compression fractures by osteoporosis (OVF) is usually a diagnostic problem and coincides on the age group of metastatic vertebral compression fractures (MVF). Although radiography is the first diagnostic technique, generally is not accurate for depicting demineralization and soft tissue lesions. Magnetic resonance (MRI) is the diagnostic choice. The most relevant signs are intravertebral fluid collection or fluid signal, other vertebral deformities without oedema and older age. Among the most relevant findings for diagnosis MVF are soft tissue mass and pedicle intensity signal asymmetries. However, reproducibility of these findings in clinical practice is moderate.

14.
Int J Ophthalmol ; 17(7): 1307-1312, 2024.
Article in English | MEDLINE | ID: mdl-39026900

ABSTRACT

AIM: To observe the effects of femtosecond laser-assisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking (FS-LASIK Xtra) on corneal densitometry after correcting for high myopia. METHODS: In this prospectively study, 130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia. Their right eyes were selected for inclusion in the study, of which 65 cases of 65 eyes in the FS-LASIK group, 65 patients with 65 eyes in the FS-LASIK Xtra group. Patients were evaluated for corneal densitometry at 1, 3, and 6mo postoperatively using Pentacam Scheimpflug imaging. RESULTS: Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant (P>0.05). Layer-by-layer analysis revealed statistically significant differences in the anterior (120 µm), central, and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively (all P<0.05), the FS-LASIK Xtra group is higher than that of the FS-LASIK group. Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0-2, 2-6, and 6-10 mm (both P<0.05); At 3mo postoperatively, the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0-2 and 2-6 mm (P<0.05). At 6mo postoperatively, there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges (all P>0.05). CONCLUSION: There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia. However, the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery, with the most significant changes observed in the superficial central zone.

15.
Med Clin (Barc) ; 2024 Jul 16.
Article in English, Spanish | MEDLINE | ID: mdl-39019666

ABSTRACT

With the increased life expectancy of people with cystic fibrosis (CF), clinical attention has focused on prevention and treatment of non-pulmonary comorbidities. CF-related bone disease (CFBD) is a common complication and leads to increased fracture rates. Dual energy X-ray absorptiometry (DXA) is the recommended and gold standard technique to identify and monitor bone health. However, DXA has limitations because of its two-dimensional nature. Complementary tools to DXA are available, such as trabecular bone score (TBS) and vertebral fracture assessment (VFA). Quantitative computed tomography (QCT), magnetic resonance imaging (MRI) and quantitative ultrasound (QUS) may also be useful.

17.
Int Ophthalmol ; 44(1): 294, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38943020

ABSTRACT

PURPOSE: To investigate the clinical significance of the correlation between optical densitometry and both biomechanical and morphological parameters in keratoconus (KC) and to verify the diagnostic value of optical densitometry in KC. METHOD: This cross-sectional study included 436 eyes of 295 patients with KC. Corneal optical densitometry, morphological parameters and biomechanical parameters were measured. Spearman's correlation analysis was employed to investigate the association between optical densitometry and both biomechanical and morphological parameters. RESULT: Optical densitometry of the anterior (0-2 mm and 2-6 mm), central (0-2 mm), posterior (2-6 mm) and total (2-6 mm) layers correlated positively with SPA1, while the posterior layer (0-2 mm) correlated negatively. Optical densitometry of the anterior layers 2-6 mm, 6-10 mm, and the central layer 6-10 mm negatively affected AL1, while the posterior layer 0-2 mm positively affected it. Optical densitometry of the anterior, central, and posterior layers 0-2 mm and 2-6 mm positively influenced the morphological parameters K1F, K2F, KmF and the absolute values of K1B, K2B, KmB. Optical densitometry of the center (0-2 mm) and posterior (2-6 mm) layers negatively influenced TCT. Optical densitometry of the anterior (0-2 mm and 2-6 mm), center (0-2 mm), posterior (2-6 mm) and total (2-6 mm) layers correlated positively with ACE and PCE, whereas the posterior layer (0-2 mm) correlated negatively. CONCLUSION: Optical densitometry was correlated with biomechanical and morphological parameters in keratoconus, suggesting its potential as a diagnostic indicator for assessing keratoconus progression and treatment efficacy.


Subject(s)
Cornea , Corneal Topography , Densitometry , Keratoconus , Humans , Keratoconus/diagnosis , Keratoconus/physiopathology , Cross-Sectional Studies , Female , Densitometry/methods , Male , Cornea/diagnostic imaging , Cornea/pathology , Adult , Corneal Topography/methods , Young Adult , Adolescent , Middle Aged , Biomechanical Phenomena
18.
Article in English, Spanish | MEDLINE | ID: mdl-38878884

ABSTRACT

Vertebral compression fractures by osteoporosis (OVF) is usually a diagnostic problem and coincides on the age group of metastatic vertebral compression fractures (MVF). Although radiography is the first diagnostic technique, generally is not accurate for depicting demineralization and soft tissue lesions. Magnetic resonance (MRI) is the diagnostic choice. The most relevant signs are Intravertebral fluid collection or fluid signal, other vertebral deformities without edema and older age. Among the most relevant findings for diagnosis MVF are soft tissue mass and pedicle intensity signal asymmetries. However, reproducibility of these findings in clinical practice is moderate.

19.
Clin Exp Optom ; : 1-5, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38914426

ABSTRACT

CLINICAL RELEVANCE: Isotretinoin has been the best treatment option for moderate and severe acne vulgaris since the 1980s. Some studies have shown evidence of subclinical anterior segment involvement of the eye in patients treated with isotretinoin. BACKGROUND: This study aimed to evaluate lens clarity with the densitometry software of Scheimpflug tomography in patients treated with isotretinoin and to compare with healthy control subjects. METHODS: Thirty-seven acnepatients treated with isotretinoin who met the inclusion criteria (24 males and 13 females, mean age 22.94 ± 4.21 years) and 39 healthy control subjects were included in the study. Clinical characteristics of the isotretinoin and control subjects were recorded. Lens density was evaluated with the densitometry software of the Scheimpflug tomography device (PentacamHR, Oculus, Wetzlar, Germany). RESULTS: There was no statistically significant difference between the groups in age, gender distribution, spherical equivalent, or anterior segment parameters measured by the Pentacam system (p > 0.05 for all). Lens density values in zones 2 and 3 were significantly higher in the isotretinoin group (p = 0.042, p < 0.001) and positively correlated with cumulative isotretinoin dose (zone 2: r = 0.384, p = 0.032; zone 3: r = 0.384, p = 0.005). CONCLUSION: Zone 2 and zone 3 lens density are higher in patients treated with isotretinoin when compared to healthy controls.

20.
Bull Exp Biol Med ; 176(6): 827-829, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38890211

ABSTRACT

The severity of ischemic injury was evaluated by densitometry of brain samples stained with 2,3,5-triphenyltetrazolium chloride (TTC) on a rat model of cerebral ischemia/reperfusion (common carotid artery occlusion) and the neuroprotective activity of an extract of Astragalus membranaceus, Scutellaria baicalensis, and Phlojodicarpus sibiricus was assessed. Occlusion of the common carotid arteries led to a weakening of TTC staining of the brain tissue: densitometric indicators of the staining intensity for the cortex and striatum were lower than the corresponding indicators of sham-operated rats by 18.3 and 10.4%. The mean intensity of staining of brain samples did not differ in rats treated with the extract and sham-operated animals, which attested to its neuroprotective effect. The applied method is convenient for evaluation of the severity of ischemic brain damage at the early stages and screening potential neuroprotective agents.


Subject(s)
Brain Ischemia , Neuroprotective Agents , Plant Extracts , Animals , Rats , Neuroprotective Agents/pharmacology , Neuroprotective Agents/therapeutic use , Male , Brain Ischemia/drug therapy , Brain Ischemia/pathology , Plant Extracts/pharmacology , Plant Extracts/therapeutic use , Astragalus propinquus/chemistry , Reperfusion Injury/drug therapy , Reperfusion Injury/pathology , Reperfusion Injury/prevention & control , Tetrazolium Salts/chemistry , Brain/drug effects , Brain/pathology , Rats, Wistar , Disease Models, Animal , Scutellaria baicalensis
SELECTION OF CITATIONS
SEARCH DETAIL