Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 820
Filter
1.
Gastrointest Endosc ; 2024 Aug 05.
Article in English | MEDLINE | ID: mdl-39111392

ABSTRACT

BACKGROUND AND AIMS: Many gastrointestinal (GI) disorders and precancerous conditions often present asymptomatically, leading to delayed patient diagnoses and treatment interventions. This study aimed to develop a novel cable-transmission magnetically controlled capsule endoscopy (CT-MCCE) system for detecting GI diseases and assess its safety and feasibility through clinical trials. METHODS: This prospective, multicenter, trial compared CT-MCCE with conventional gastroscopy in patients aged 18-75 years with upper GI diseases between October 2022 and May 2023. The primary endpoints included the evaluation of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) in the detection of focal lesions within the esophagus, stomach, and duodenal bulb using CT-MCCE. RESULTS: A total of 180 individuals (mean age: 43.1 years, 52.22% female) were recruited from three hospitals in China. CT-MCCE detected lesions in esophagus with 97.22% sensitivity, 100% specificity, a PPV of 100%, a NPV of 98.18%, and 98.89% accuracy. CT-MCCE detected gastric focal lesions in the whole stomach with 96.81% sensitivity, 98.84% specificity, a PPV of 98.91%, a NPV of 96.59%, and 97.78% accuracy. CT-MCCE detected lesions in the duodenal bulb with 100% sensitivity, 100% specificity, a PPV of 100%, a NPV of 100%, and 100% accuracy. There were no significant differences between CT-MCCE and EGD regarding the cleanliness of the upper GI tract and visibility of the upper GI mucosa. However, CT-MCCE was associated with a lower incidence of discomfort than EGD (P<0.001). CONCLUSIONS: The diagnostic performance of CT-MCCE is comparable to that of EGD in the completion of upper GI tract examinations and lesion detection. Furthermore, the improved tolerance of CT-MCCE in detecting upper GI diseases was noted without any observed adverse events.

2.
Article in English | MEDLINE | ID: mdl-39093525

ABSTRACT

PURPOSE: The current diagnostic methods for leptospirosis diagnosis are technically complex and expensive, with limited applicability to specialized laboratories. Furthermore, they lack diagnostic accuracy in the acute stage of the disease, which coincides with a period when antibiotics are highly effective. New simple and accurate tests are mandatory to decentralize and improve diagnosis. Here, we introduced a new lateral flow immunoassay (Lepto-LF) for human leptospirosis. METHODS: We conducted a double-blinded assay using 104 serum samples from patients with confirmed or discarded diagnosis for leptospirosis. The diagnostic performance of Lepto-LF was estimated across different ranges of days from onset of symptoms (dpo), considering the diagnostic algorithm as reference standard. Additionally, it was compared with the screening methods enzyme-linked immunosorbent assay (IgM-ELISA) and the slide agglutination test using temperature-resistant antigen (SATR). RESULTS: Lepto-LF exhibited perfect diagnostic performance with a Youden´s index J = 1 from 6 dpo in the acute phase. IgM-ELISA gave slightly lower accuracy with J = 0.91 and 95.5% of both sensitivity and specificity; while SATR showed a markedly inferior yield (J = 0.41, sensitivity = 95.5%, specificity = 45.5%). The performances remained consistent in the convalescence phase of the disease (> 10 dpo). CONCLUSION: Lepto-LF was found to be a reliable test for simple, rapid and early diagnosis of leptospirosis, resulting a promising tool for decentralizing leptospirosis diagnosis and enabling timely treatment of patients. In addition, Lepto-LF may be employed as confirmatory test, especially in remote areas and vulnerable contexts where the standard MAT is not available.

3.
J Med Virol ; 96(8): e29835, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39087721

ABSTRACT

The risk associated with single and multiple human papillomavirus (HPV) infections in cervical intraepithelial neoplasia (CIN) remains uncertain. This study aims to explore the distribution and diagnostic significance of the number of high-risk HPV (hr-HPV) infections in detecting CIN, addressing a crucial gap in our understanding. This comprehensive multicenter, retrospective study meticulously analyzed the distribution of single and multiple hr-HPV, the risk of CIN2+, the relationship with CIN, and the impact on the diagnostic performance of colposcopy using demographic information, clinical histories, and tissue samples. The composition of a single infection was predominantly HPV16, 52, 58, 18, and 51, while HPV16 and 33 were identified as the primary causes of CIN2+. The primary instances of dual infection were mainly observed in combinations such as HPV16/18, HPV16/52, and HPV16/58, while HPV16/33 was identified as the primary cause of CIN2+. The incidence of hr-HPV infections shows a dose-response relationship with the risk of CIN (p for trend <0.001). Compared to single hr-HPV, multiple hr-HPV infections were associated with increased risks of CIN1 (1.44, 95% confidence interval [CI]: 1.20-1.72), CIN2 (1.70, 95% CI: 1.38-2.09), and CIN3 (1.08, 95% CI: 0.86-1.37). The colposcopy-based specificity of single hr-HPV (93.4, 95% CI: 92.4-94.4) and multiple hr-HPV (92.9, 95% CI: 90.8-94.6) was significantly lower than negative (97.9, 95% CI: 97.0-98.5) in detecting high-grade squamous intraepithelial lesion or worse (HSIL+). However, the sensitivity of single hr-HPV (73.5, 95% CI: 70.8-76.0) and multiple hr-HPV (71.8, 95% CI: 67.0-76.2) was higher than negative (62.0, 95% CI: 51.0-71.9) in detecting HSIL+. We found that multiple hr-HPV infections increase the risk of developing CIN lesions compared to a single infection. Colposcopy for HSIL+ detection showed high sensitivity and low specificity for hr-HPV infection. Apart from HPV16, this study also found that HPV33 is a major pathogenic genotype.


Subject(s)
Papillomavirus Infections , Uterine Cervical Dysplasia , Uterine Cervical Neoplasms , Humans , Female , Retrospective Studies , Papillomavirus Infections/diagnosis , Papillomavirus Infections/virology , Papillomavirus Infections/epidemiology , Papillomavirus Infections/complications , China/epidemiology , Uterine Cervical Dysplasia/virology , Uterine Cervical Dysplasia/diagnosis , Uterine Cervical Dysplasia/epidemiology , Adult , Middle Aged , Young Adult , Uterine Cervical Neoplasms/virology , Uterine Cervical Neoplasms/diagnosis , Uterine Cervical Neoplasms/epidemiology , Colposcopy , Coinfection/virology , Coinfection/epidemiology , Papillomaviridae/genetics , Papillomaviridae/isolation & purification , Papillomaviridae/classification , Aged , Genotype , Incidence
4.
J Orthop Surg Res ; 19(1): 456, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090629

ABSTRACT

BACKGROUND: The accuracy of traditional knee MR imaging in diagnosing anterior cruciate ligament tears, especially partial tears, is relatively low, which may lead to misdiagnosis and missed diagnosis. This study aimed to assess the diagnostic performance of a novel imaging method, high-resolution oblique coronal MRI at an optimal flexed-knee Angle, for ACL tears. METHODS: 50 healthy volunteers were scanned with a scan-assisted device for the optimal flexion angle of ACL. For 92 knee trauma patients selected strictly according to inclusion and exclusion criteria, conventional extended-knee scans (control group) and high-resolution oblique coronal scans based on the optimal flexed-knee angle (experimental group) were conducted. Two observers rated ACL visibility blindly on a 5-point scale. Arthroscopy-defined outcomes determined diagnostic metrics for each method and sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated. RESULTS: The average optimal flexion angle for healthy volunteers was approximately 30° (30.3° ± 5.0°). Imaging demonstrated complete visualization of the ACL in 96.7% of images in the experimental group versus 12.0% in the control group. The diagnostic indicators of the experimental group surpassed those of the control group: sensitivity (94.9% vs. 76.3%), specificity (97.0% vs. 81.8%), positive predictive value (98.2% vs. 88.2%), negative predictive value(91.4% vs. 65.9%), and accuracy (95.7% vs. 78.3%). ROC analysis indicated superior diagnostic performance in the experimental group, with an AUC of 0.945 compared with 0.776 for the control group (p < 0.0001). CONCLUSIONS: High-resolution oblique coronal imaging at the optimal 30° flexed-knee angle improved ACL visualization and diagnostic performance compared with conventional techniques.


Subject(s)
Anterior Cruciate Ligament Injuries , Magnetic Resonance Imaging , Humans , Anterior Cruciate Ligament Injuries/diagnostic imaging , Magnetic Resonance Imaging/methods , Female , Male , Adult , Young Adult , Middle Aged , Knee Joint/diagnostic imaging , Adolescent , Arthroscopy/methods
5.
Indian J Med Microbiol ; 51: 100700, 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39127256

ABSTRACT

INTRODUCTION: COVID-19 disease continues to be a global health concern. The current protocol for detecting SARS-CoV-2 requires healthcare professionals to draw blood from patients. Recent studies showed that dried blood spot (DBS) is a valuable sampling procedure that can collect a low blood volume without the need for the presence of medical practitioners. This study synthesized the available literature on using DBS as a blood collection tool to diagnose COVID-19 disease. MATERIALS AND METHODS: A comprehensive search utilizing OVID, CINAHL, and Scopus databases was done from inception to March 2023. Five reviewers collected, extracted and organized the study data. RESULTS: This systematic review included 57 articles. DBS was commonly prepared by finger pricking. Most studies showed more favorable results and longer sample stability (more than 1080 days) with lower storage temperature conditions for the DBS. DBS samples were mostly used for serological assays for COVID-19 disease detection. ELISA was the most used detection method (43.66 %). Diagnostic performance of laboratory tests for COVID-19 using DBS sample showed high sensitivity of up to 100 % for immunoassay tests and 100 % specificity in agglutination, PCR, and DELFIA assays. CONCLUSION: DBS sampling coupled with serological testing can be an alternative method for collecting blood and detecting COVID-19 disease. These tests using DBS samples showed excellent diagnostic performance across various geographic locations and demographics.

6.
BMC Med Imaging ; 24(1): 212, 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39134937

ABSTRACT

BACKGROUND: Prostate cancer is one of the most common malignant tumors in middle-aged and elderly men and carries significant prognostic implications, and recent studies suggest that dual-energy computed tomography (DECT) utilizing new virtual monoenergetic images can enhance cancer detection rates. This study aimed to assess the impact of virtual monoenergetic images reconstructed from DECT arterial phase scans on the image quality of prostate lesions and their diagnostic performance for prostate cancer. METHODS: We conducted a retrospective analysis of 83 patients with prostate cancer or prostatic hyperplasia who underwent DECT scans at Meizhou People's Hospital between July 2019 and December 2023. The variables analyzed included age, tumor diameter and serum prostate-specific antigen (PSA) levels, among others. We also compared CT values, signal-to-noise ratio (SNR), subjective image quality ratings, and contrast-to-noise ratio (CNR) between virtual monoenergetic images (40-100 keV) and conventional linear blending images. Receiver operating characteristic (ROC) curve analyses were performed to evaluate the diagnostic efficacy of virtual monoenergetic images (40 keV and 50 keV) compared to conventional images. RESULTS: Virtual monoenergetic images at 40 keV showed significantly higher CT values (168.19 ± 57.14) compared to conventional linear blending images (66.66 ± 15.5) for prostate cancer (P < 0.001). The 50 keV images also demonstrated elevated CT values (121.73 ± 39.21) compared to conventional images (P < 0.001). CNR values for the 40 keV (3.81 ± 2.13) and 50 keV (2.95 ± 1.50) groups were significantly higher than the conventional blending group (P < 0.001). Subjective evaluations indicated markedly better image quality scores for 40 keV (median score of 5) and 50 keV (median score of 5) images compared to conventional images (P < 0.05). ROC curve analysis revealed superior diagnostic accuracy for 40 keV (AUC: 0.910) and 50 keV (AUC: 0.910) images based on CT values compared to conventional images (AUC: 0.849). CONCLUSIONS: Virtual monoenergetic images reconstructed at 40 keV and 50 keV from DECT arterial phase scans substantially enhance the image quality of prostate lesions and improve diagnostic efficacy for prostate cancer.


Subject(s)
Prostatic Neoplasms , Signal-To-Noise Ratio , Tomography, X-Ray Computed , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Retrospective Studies , Aged , Middle Aged , Tomography, X-Ray Computed/methods , ROC Curve , Radiography, Dual-Energy Scanned Projection/methods , Prostatic Hyperplasia/diagnostic imaging , Aged, 80 and over , Radiographic Image Interpretation, Computer-Assisted/methods , Prostate-Specific Antigen/blood
7.
J Virol Methods ; : 115008, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39153529

ABSTRACT

Infectious hematopoietic necrosis virus (IHNV) severely and lethally infects salmonid fish, including Atlantic salmon (Salmo salar) and rainbow trout (Oncorhynchus mykiss) worldwide. Rapid and accurate viral detection is crucial for preventing pathogen spread and minimizing damage. Although several IHNV detection assays have been developed, their analytical and diagnostic performances have not been evaluated and field usability assessments have not been completely validated. Here, we developed a reverse-transcription cross-priming amplification-based lateral flow assay (RT-CPA-LFA) and validated its diagnostic performance. To detect the IHNV, primers were designed based on the consensus sequence of the nucleocapsid (N) gene. Notably, when combined with a lateral flow dipstick, it could visualize the IHNV amplification products within 5min and the detection limit of the developed RT-CPA-LFA was 3.28×105 copies/µL. The diagnostic sensitivity and specificity in fish samples (n=140) were 98.88% and 96.08%, respectively. Moreover, the IHNV detection rate by RT-CPA-LFA in dead rainbow trout artificially injected with the virus was 100%, consistent with to the results obtained from second conventional and real-time PCR, indicating its applicability for rapid IHNV detection and presumptive IHN diagnosis during the endemic period.

8.
Emerg Microbes Infect ; : 2392656, 2024 Aug 13.
Article in English | MEDLINE | ID: mdl-39136526

ABSTRACT

AbstractLack of appropriate early diagnostic tools for drug-resistant tuberculosis (DR-TB) and their incomplete drug susceptibility testing (DST) profiling is concerning for TB disease control. Existing methods, such as phenotypic DST (pDST), are time-consuming, while Xpert MTB/RIF (Xpert) and line probe assay (LPA) are limited to detecting resistance to few drugs. Targeted next-generation sequencing (tNGS) has been recently approved by WHO as an alternative approach for rapid and comprehensive DST. We aimed to investigate the performance and feasibility of tNGS for detecting DR-TB directly from clinical samples in Bangladesh. pDST, LPA and tNGS were performed among 264 sputum samples, either rifampicin-resistant (RR) or rifampicin-sensitive (RS) TB cases confirmed by Xpert assay. Resistotypes of tNGS were compared with pDST, LPA and composite reference standard (CRS, resistant if either pDST or LPA showed a resistant result). tNGS results revealed higher sensitivities for rifampicin (RIF) (99.3%), isoniazid (INH) (96.3%), fluoroquinolones (FQs) (94.4%), and aminoglycosides (AMGs) (100%) but comparatively lower for ethambutol (76.6%), streptomycin (68.7%), ethionamide (56.0%) and pyrazinamide (50.7%) when compared with pDST. The sensitivities of tNGS for INH, RIF, FQs and AMGs were 93.0%, 96.6%, 90.9%, and 100%, respectively and the specificities ranged from 91.3% to 100% when compared with CRS. This proof of concept study, conducted in a high-burden setting demonstrated that tNGS is a valuable tool for identifying DR-TB directly from the clinical specimens. Its feasibility in our laboratory suggests potential implementation and moving tNGS from research settings into clinical settings.

9.
Heliyon ; 10(14): e32698, 2024 Jul 30.
Article in English | MEDLINE | ID: mdl-39113996

ABSTRACT

Serological detection of hepatitis B virus markers plays a vital role in the diagnosis, treatment, prognosis, and therapeutic surveillance of hepatitis B. To compare the diagnostic performance of Autolumo A2000Plus and Abbott Architect i2000 systems in the detection of hepatitis B infection markers. A total of 6 HBV seroconversion panels and 743 participants were enrolled in this study, including 383 HBV-infected patients and 360 healthy adults. Clinical diagnostic information, laboratory results, and HBV genotyping were collected to evaluate the diagnostic performance of the A2000Plus and i2000 systems in detecting HBV infection markers. The results showed that the total percent agreement of HBV markers was all >90 % in both detection systems among the six seroconversion panels and 743 serum samples from the population. The χ2 values of the Chi-square test among hepatitis B virus serological markers in both analyzers were between 550.7 and 743.0, p < 0.0001. HBV marker consistency test results show perfect consistency between the two analyzers, with Kappa values ranging from 0.854 to 1.000. For specific samples, including Hepatitis B patients with Genotype C, chronic hepatitis B, hepatitis B-related cirrhosis, and hepatocellular carcinoma, spearman correlation analysis showed HBsAg correlation coefficients ranging from 0.8532 to 0.9745, p < 0.001 in both analyzers. In conclusion, Autolumo A2000Plus diagnostic performance in consistency and correlation is comparable to Abbott Architect i2000 when detecting markers of hepatitis B infection. The Autolumo A2000Plus system can be used as a reliable instrument for HBV marker detection.

10.
Article in English | MEDLINE | ID: mdl-39082924

ABSTRACT

INTRODUCTION: Our objective was to determine whether the educational game SonoQz can improve diagnostic performance in ultrasound assessment of ovarian tumors. MATERIAL AND METHODS: The SonoQz mobile application was developed as an educational tool for medical doctors to practice ultrasound assessment, based on still images of ovarian tumors. The game comprises images from 324 ovarian tumors, examined by an ultrasound expert prior to surgery. A training phase, where the participants assessed at least 200 cases in the SonoQz app, was preceded by a pretraining test, and followed by a posttraining test. Two equal tests (A and B), each consisting of 20 cases, were used as pre- and posttraining tests. Half the users took test A first, B second, and the remaining took the tests in the opposite order. Users were asked to classify the tumors (1) according to International Ovarian Tumor Analysis (IOTA) Simple Rules, (2) as benign or malignant, and (3) suggest a specific histological diagnosis. Logistic mixed models with fixed effects for pre- and posttraining tests, and crossed random effects for participants and cases, were used to determine any improvement in test scores, sensitivity, and specificity. RESULTS: Fifty-eight doctors from 19 medical centers participated. Comparing the pre- and posttraining test, the median of correctly classified cases, in Simple Rules assessment increased from 72% to 83%, p < 0.001; in classifying the lesion as benign or malignant tumors from 86% to 95%, p < 0.001; and in making a specific diagnosis from 43% to 63%, p < 0.001. When classifying tumors as benign or malignant, at an unchanged level of sensitivity (98% vs. 97%, p = 0.157), the specificity increased from 70% to 89%, p < 0.001. CONCLUSIONS: Our results indicate that the educational game SonoQz is an effective tool that may improve diagnostic performance in assessing ovarian tumors, specifically by reducing the number of false positives while maintaining high sensitivity.

11.
Abdom Radiol (NY) ; 2024 Jul 31.
Article in English | MEDLINE | ID: mdl-39083068

ABSTRACT

PURPOSE: This study aims to assess the diagnostic capabilities of Diffusion Kurtosis Imaging (DKI) and Intravoxel Incoherent Motion (IVIM) in prostate cancer (PCa) detection and characterization. MATERIALS: A comprehensive search was conducted across PubMed, Scopus, Web of Science, and the Cochrane Library for articles published up to September 10, 2023, that evaluated the diagnostic efficacy of MD, MK, Dt, f, and Dp parameters. Data were pooled using a bivariate mixed-effects regression model and analyzed with R software. RESULTS: In total, 27 studies were included. The analysis revealed distinct diagnostic efficacies for DKI and IVIM. In the overall model, sensitivity and specificity were 0.807 and 0.797, respectively, with prospective studies showing higher specificity (0.858, p = 0.024). The detection model yielded increased sensitivity (0.845) and specificity (0.812), with DKI outperforming IVIM in both metrics (sensitivity: 0.87, p = 0.043; specificity: 0.837, p = 0.26); MD had high sensitivity (0.88) and specificity (0.82), while MK's specificity was significantly higher (0.854, p = 0.04); Dp's sensitivity was significantly lower (0.64, p = 0.016). In characterization, sensitivity and specificity were 0.708 and 0.735, respectively, with no significant differences between DKI and IVIM or Gleason Scores; MK had higher sensitivity (0.78, p = 0.039), and f's sensitivity was significantly lower (0.51, p = 0.019). CONCLUSION: In summary, the study underscores DKI's enhanced diagnostic accuracy over IVIM in detecting PCa, with MK standing out for its precision. Conversely, Dp and f lag in diagnostic performance. Despite these promising results, the study highlights the imperative for standardized protocols and study designs to achieve reliable and consistent outcomes.

12.
Sci Rep ; 14(1): 15986, 2024 07 10.
Article in English | MEDLINE | ID: mdl-38987641

ABSTRACT

The purpose of the present study is to evaluate whether an online reference system (ORS, STATdx Elsevier, Amsterdam, Netherlands) impacts finding the histologically confirmed diagnosis of rare or atypical abdominal tumors and lesions in radiologic imaging. In total, 101 patients with rare tumor entities or lesions and atypical manifestations of common tumors were enrolled retrospectively. Blinded readings were performed by four radiologists with varying levels of experience, who reported on: (a) correct diagnosis (CD), (b) time needed to find the diagnosis, and (c) diagnostic confidence, initially without followed by the assistance of the ORS. The experienced reader (3 years of experience post-residency, CD 49.5%), as well as the advanced reader with 1 year of experience post-residency (CD 43.6%), and a resident with 5 years of experience (CD 46.5%) made the correct diagnosis more frequently compared to the less experienced reader (CD 25.7%). A significant improvement in making the correct diagnosis was only achieved by the advanced reader, the resident with 5 years of experience (CD with ORS 58.4%; p < 0.001). The advanced reader with 1 year of experience post-residency improved slightly (CD ORS 47.5%). The experienced reader (CD ORS 50.5%) and the less experienced reader (CD ORS 27.7%) did not improve significantly. The overall subjective confidence increased significantly when ORS was used (3.2 ± 0.9 vs. 3.8 ± 0.9; p < 0.001). While the ORS had a positive impact on making the correct diagnosis throughout all readers, it favored radiologists with more clinical experience rather than inexperienced residents. Moreover, the ORS increased the diagnostic confidence of all radiologists significantly. In conclusion, the ORS had no significant impact on the diagnosis of rare or atypical abdominal tumors and lesions except for one reader. The greatest benefit is the increase in diagnostic confidence.


Subject(s)
Abdominal Neoplasms , Humans , Female , Male , Middle Aged , Aged , Adult , Abdominal Neoplasms/diagnosis , Abdominal Neoplasms/pathology , Retrospective Studies , Aged, 80 and over , Young Adult , Adolescent , Online Systems
13.
Article in English | MEDLINE | ID: mdl-38958680

ABSTRACT

PURPOSE: While sedation is routinely used in pediatric PET examinations to preserve diagnostic quality, it may result in side effects and may affect the radiotracer's biodistribution. This study aims to investigate the feasibility of sedation-free pediatric PET imaging using ultra-fast total-body (TB) PET scanners and deep learning (DL)-based attenuation and scatter correction (ASC). METHODS: This retrospective study included TB PET (uExplorer) imaging of 35 sedated pediatric patients under four years old to determine the minimum effective scanning time. A DL-based ASC method was applied to enhance PET quantification. Both quantitative and qualitative assessments were conducted to evaluate the image quality of ultra-fast DL-ASC PET. Five non-sedated pediatric patients were subsequently used to validate the proposed approach. RESULTS: Comparisons between standard 300-second and ultra-fast 15-second imaging, CT-ASC and DL-ASC ultra-fast 15-second images, as well as DL-ASC ultra-fast 15-second images in non-sedated and sedated patients, showed no significant differences in qualitative scoring, lesion detectability, and quantitative Standard Uptake Value (SUV) (P = ns). CONCLUSIONS: This study demonstrates that pediatric PET imaging can be effectively performed without sedation by combining ultra-fast imaging techniques with a DL-based ASC. This advancement in sedation-free ultra-fast PET imaging holds potential for broader clinical adoption.

14.
Telemed J E Health ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38946689

ABSTRACT

Background: Mobile health (mHealth) has an emerging potential for remote assessment of traumatic dental injuries (TDI) and support of emergency care. This study aimed to determine the diagnostic accuracy of TDI detection from smartphone-acquired photographs. Methods: The upper and lower anterior teeth of 153 individuals aged ≥ 6 years were photographed using a smartphone camera app. The photos of 148 eligible participants were reviewed independently by a dental specialist, two general dentists, and two dental therapists, using predetermined TDI classification and criteria. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and inter-rater reliability were estimated to evaluate the diagnostic performance of the photographic method relative to the reference standard established by the dental specialist. Results: Of the 1,870 teeth screened, one-third showed TDI; and one-seventh of the participants had primary or mixed dentitions. Compared between the specialist's reference standard and four dental professionals' reviews, the diagnostic sensitivity and specificity for TDI versus non-TDI were 59-95% and 47-93%, respectively, with better performance for urgent types of TDI (78-89% and 99-100%, separately). The diagnostic consistency was also better for the primary/mixed dentitions than the permanent dentition. Conclusion: This study suggested a valid mHealth practice for remote assessment of TDI. A better diagnostic performance in the detection of urgent types of TDI and examination of the primary/mixed dentition was also reported. Future directions include professional development activities involving dental photography and photographic assessment, incorporation of a machine learning technology to aid photographic reviews, and randomized controlled trials in multiple clinical settings.

15.
Eur Spine J ; 33(8): 2982-2996, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39007984

ABSTRACT

OBJECTIVES: To investigate potential of enhancing image quality, maintaining interobserver consensus, and elevating disease diagnostic efficacy through the implementation of deep learning-based reconstruction (DLR) processing in 3.0 T cervical spine fast magnetic resonance imaging (MRI) images, compared with conventional images. METHODS: The 3.0 T cervical spine MRI images of 71 volunteers were categorized into two groups: sagittal T2-weighted short T1 inversion recovery without DLR (Sag T2w-STIR) and with DLR (Sag T2w-STIR-DLR). The assessment covered artifacts, perceptual signal-to-noise ratio, clearness of tissue interfaces, fat suppression, overall image quality, and the delineation of spinal cord, vertebrae, discs, dopamine, and joints. Spanning canal stenosis, neural foraminal stenosis, herniated discs, annular fissures, hypertrophy of the ligamentum flavum or vertebral facet joints, and intervertebral disc degeneration were evaluated by three impartial readers. RESULTS: Sag T2w-STIR-DLR images exhibited markedly superior performance across quality indicators (median = 4 or 5) compared to Sag T2w-STIR sequences (median = 3 or 4) (p < 0.001). No statistically significant differences were observed between the two sequences in terms of diagnosis and grading (p > 0.05). The interobserver agreement for Sag T2w-STIR-DLR images (0.604-0.931) was higher than the other (0.545-0.853), Sag T2w-STIR-DLR (0.747-1.000) demonstrated increased concordance between reader 1 and reader 3 in comparison to Sag T2w-STIR (0.508-1.000). Acquisition time diminished from 364 to 197 s through the DLR scheme. CONCLUSIONS: Our investigation establishes that 3.0 T fast MRI images subjected to DLR processing present heightened image quality, bolstered diagnostic performance, and reduced scanning durations for cervical spine MRI compared with conventional sequences.


Subject(s)
Cervical Vertebrae , Deep Learning , Magnetic Resonance Imaging , Spondylosis , Humans , Spondylosis/diagnostic imaging , Magnetic Resonance Imaging/methods , Male , Adult , Female , Cervical Vertebrae/diagnostic imaging , Middle Aged , Aged , Image Processing, Computer-Assisted/methods
16.
Prev Vet Med ; 230: 106292, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39068789

ABSTRACT

Influenza A virus (IAV) is an important pathogen in Brazilian swine herds, and monitoring the viral circulation is essential to control and reduce the transmission. Surveillance programs for IAV are often based on individual piglets level sampling, making the evaluation of the available diagnostic tools crucial to assessing IAV circulation in herds. Thus, two sample collection methodologies were compared in pig herds in southern Brazil to detect IAV by RT-qPCR: nasal swab (NS) and nasal wipe (NW). A Bayesian latent class model (BLCM) was set for two tests and two populations. The NW and NS used are more specific (higher than 95 % for both) than sensitive. The sensitivity for NW was lower than the NS, 84.14 % (70 % - 95 %; posterior probability interval (PPI): 95 %) and 87.15 % (73 % - 97 %; PPI: 95 %), respectively, and the specificity was 95 % (90 % - 99 %; PPI: 95 %) and 99 % (96 % - 100 %; PPI: 95 %), respectively. Although the wipe sample collection loses both sensitivity and specificity compared with nasal swab, differences in test performance were very limited and PPIs largely overlapped. Therefore NW can also be considered a valuable tool. The decision about the use of both techniques should be based on the trade-off between their performance limitations and feasibility in routine monitoring.


Subject(s)
Bayes Theorem , Influenza A virus , Latent Class Analysis , Orthomyxoviridae Infections , Sensitivity and Specificity , Swine Diseases , Animals , Swine Diseases/virology , Swine Diseases/diagnosis , Swine , Orthomyxoviridae Infections/veterinary , Orthomyxoviridae Infections/virology , Orthomyxoviridae Infections/diagnosis , Orthomyxoviridae Infections/epidemiology , Influenza A virus/isolation & purification , Brazil/epidemiology , Specimen Handling/veterinary , Specimen Handling/methods , Real-Time Polymerase Chain Reaction/veterinary , Nose/virology
17.
Sci Rep ; 14(1): 16316, 2024 07 15.
Article in English | MEDLINE | ID: mdl-39009884

ABSTRACT

The objective of this study was to evaluate semi-quantitatively the diagnostic performance of PET/CT metabolic parameters in differentiating benign or malignant cardiac or pericardial masses. A total of forty-one patients with newly diagnosed cardiac/pericardial masses who underwent 18F-FDG PET/CT were recruited. PET/CT metabolic parameters including the maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), total lesion glycolysis (TLG), tumor metabolic volume (MTV), the maximum tumor-to-mediastinal background ratio (TMR) and the maximum tumor-to-liver background ratio (TLR) is measured or calculated to evaluate the benign or malignant nature of cardiac/pericardial masses. Compared with benign cardiac/pericardial lesions, cardiac/pericardial malignancies had higher SUVmax, SUVmean, TLG, MTV, TMR, and TLR. All these PET/CT metabolic parameters showed high diagnostic performance in semi-quantitative evaluation of benign or malignant cardiac or pericardial masses, and SUVmean and MTV had the highest diagnostic accuracy. Therefore, PET/CT metabolic parameters can semi-quantitatively evaluate the benign or malignant cardiac/pericardial masses.


Subject(s)
Fluorodeoxyglucose F18 , Heart Neoplasms , Pericardium , Positron Emission Tomography Computed Tomography , Humans , Positron Emission Tomography Computed Tomography/methods , Male , Female , Middle Aged , Retrospective Studies , Heart Neoplasms/diagnostic imaging , Heart Neoplasms/metabolism , Aged , Pericardium/diagnostic imaging , Pericardium/metabolism , Pericardium/pathology , Adult , Radiopharmaceuticals , Aged, 80 and over
18.
Parasit Vectors ; 17(1): 305, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39010122

ABSTRACT

BACKGROUND: Chagas disease (CD), a neglected parasitic disease caused by Trypanosoma cruzi, poses a significant health threat in Latin America and has emerged globally because of human migration. Trypanosoma cruzi infects humans and over 100 other mammalian species, including dogs, which are important sentinels for assessing the risk of human infection. Nonetheless, the serodiagnosis of T. cruzi in dogs is still impaired by the absence of commercial tests. In this study, we investigated the diagnostic accuracy of four chimeric recombinant T. cruzi IBMP antigens (IBMP-8.1, IBMP-8.2, IBMP-8.3, and IBMP-8.4) for detecting anti-T. cruzi antibodies in dogs, using latent class analysis (LCA). METHODS: We examined 663 canine serum samples, employing indirect ELISA with the chimeric antigens. LCA was utilized to establish a latent variable as a gold standard for T. cruzi infection, revealing distinct response patterns for each antigen. RESULTS: The IBMP (Portuguese acronym for the Molecular Biology Institute of Paraná) antigens achieved area under the ROC curve (AUC) values ranging from 90.9% to 97.3%. The highest sensitivity was attributed to IBMP-8.2 (89.8%), while IBMP-8.1, IBMP-8.3, and IBMP-8.4 achieved 73.5%, 79.6%, and 85.7%, respectively. The highest specificity was observed for IBMP-8.4 (98.6%), followed by IBMP-8.2, IBMP-8.3, and IBMP-8.1 with specificities of 98.3%, 94.4%, and 92.7%, respectively. Predictive values varied according to prevalence, indicating higher effectiveness in endemic settings. CONCLUSIONS: Our findings underscore the remarkable diagnostic performance of IBMP-8.2 and IBMP-8.4 for the serodiagnosis of Trypanosoma cruzi in dogs, representing a promising tool for the diagnosis of CD in dogs. These chimeric recombinant antigens may not only enhance CD surveillance strategies but also hold broader implications for public health, contributing to the global fight against this neglected tropical disease.


Subject(s)
Antibodies, Protozoan , Antigens, Protozoan , Chagas Disease , Dog Diseases , Enzyme-Linked Immunosorbent Assay , Sensitivity and Specificity , Serologic Tests , Trypanosoma cruzi , Animals , Dogs , Chagas Disease/diagnosis , Chagas Disease/veterinary , Chagas Disease/parasitology , Trypanosoma cruzi/immunology , Trypanosoma cruzi/genetics , Dog Diseases/diagnosis , Dog Diseases/parasitology , Antigens, Protozoan/immunology , Antigens, Protozoan/genetics , Serologic Tests/methods , Serologic Tests/veterinary , Enzyme-Linked Immunosorbent Assay/methods , Enzyme-Linked Immunosorbent Assay/veterinary , Antibodies, Protozoan/blood , Recombinant Proteins/immunology , Recombinant Proteins/genetics
19.
Article in English | MEDLINE | ID: mdl-38994578

ABSTRACT

BACKGROUND: Salivary cortisol (sa-cortisol) and salivary cortisone (sa-cortisone) correlate well with serum cortisol (s-cortisol) but validated reference ranges for healthy individuals are lacking. OBJECTIVE: To establish cutoff levels for sa-cortisol and cortisone following cosyntropin testing, and assess their diagnostic utility in adrenal insufficiency (AI). METHODS: Steroids in saliva were assayed using liquid-chromatography tandem-mass-spectrometry (LCMS/MS) before and after administration of 250µg cosyntropin test in 128 healthy subjects (16 on oral estrogens) and 59 patients with suspected AI, of whom 26 were diagnosed with AI with conventional serum cortisol criteria. The cutoff level for AI was defined as the 2.5th centile in healthy subjects not receiving estrogens. Performance was evaluated by calculating diagnostic accuracy and analyzing receiver operating characteristic-curves. RESULTS: The sa-cortisol cutoff 60 minutes after cosyntropin stimulation was 12.6 nmol/L (accuracy 89%, sensitivity 85%, and specificity 90%). Sa-cortisone and the sum of sa-cortisol and cortisone exhibited poorer diagnostic performance than sa-cortisol. The correlation between sa-cortisol and s-cortisol was best described by a model incorporating two regression lines (R2 = 0.80). Segmented regression analysis identified a breakpoint at sa-cortisol 9.7 nmol/L and s-cortisol 482 nmol/L, likely corresponding to saturation of cortisol binding globulin (CBG). Healthy subjects on oral estrogens demonstrated a linear agreement between s- and sa-cortisol through all measurements. Seventeen healthy subjects repeated the test, with similar outcome, but reproducibility in terms of intraclass coefficient and correlation was poor. CONCLUSIONS: Sa-cortisol in cosyntropin-test has high diagnostic accuracy in detecting adrenal insufficiency, and is particularly useful in women on oral estrogens. A sa-cortisol > 12.6 nmol/L assayed with LCMS/MS 60 min after 250µg cosyntropin is normal.

20.
Hepatol Int ; 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39017915

ABSTRACT

BACKGROUND: Evaluation of liver fibrosis played a monumental role in the diagnosis and monitoring of chronic hepatitis B (CHB). We aimed to explore the value of serum N-glycan markers in liver fibrosis. METHODS: This multi-center (33 hospitals) study recruited 760 treatment-naïve CHB patients who underwent liver biopsy. Serum N-glycan markers were analyzed by DNA sequencer-assisted fluorophore-assisted with capillary electrophoresis (DSA-FACE) technology. First, we explore the relationship between 12 serum N-glycan markers and the fibrosis stage. Then, we developed a Px score for diagnosing significant fibrosis using the LASSO regression. Next, we compared the diagnostic performances between Px, LSM, APRI, and FIB-4. Finally, we explored the relationships between glycosyltransferase gene and liver fibrosis with RNA-transcriptome sequencing. RESULTS: We included 622 CHB participants: male-dominated (69.6%); median age 42.0 (IQR 34.0-50.0); 287 with normal ALT; 73.0% with significant fibrosis. P5(NA2), P8(NA3), and P10(NA4) were opposite to the degree of fibrosis, while other profiles (except for P0[NGA2]) increased with the degree of fibrosis. Seven profiles (P1[NGA2F], P2[NGA2FB], P3[NG1A2F], P4[NG1A2F], P7[NA2FB], P8[NA3], and P9[NA3Fb]) were selected into Px score. Px score was associated with an increased risk of significant fibrosis (for per Px score increase, the risk of significant fibrosis was increased by 3.54 times (OR = 4.54 [2.63-7.82]) in the fully-adjusted generalized linear model. p for trend was <0.001. The diagnostic performance of the Px score was superior to others. Glycosyltransferase genes were overexpressed in liver fibrosis, and glycosylation and glycosyltransferase-related pathways were significantly enriched. CONCLUSIONS: Serum N-glycan markers were positively correlated with liver fibrosis. Px score had good performance in distinguishing significant fibrosis.

SELECTION OF CITATIONS
SEARCH DETAIL