Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.086
Filter
1.
Anal Sci ; 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39093545

ABSTRACT

Real-time detection of renal biomarkers is crucial for immediate and continuous monitoring of kidney function, facilitating early diagnosis and intervention in kidney-related disorders. This proactive approach enables timely adjustments in treatment plans, particularly in critical situations, and enhances overall patient care. Wearable devices emerge as a promising solution, enabling non-invasive and real-time data collection. This comprehensive review investigates numerous types of wearable sensors designed to detect kidney biomarkers in body fluids such as sweat. It critically evaluates the precision, dependability, and user-friendliness of these devices, contemplating their seamless integration into daily life for continuous health tracking. The review highlights the potential influence of wearable technology on individualized renal healthcare and its role in preventative medicine while also addressing challenges and future directions. The review's goal is to provide guidance to academics, healthcare professionals, and technologists working on wearable solutions for renal biomarker detection by compiling the body of current knowledge and advancements.

2.
Mikrochim Acta ; 191(8): 502, 2024 08 02.
Article in English | MEDLINE | ID: mdl-39093358

ABSTRACT

An electrochemical sensor assisted by primer exchange reaction (PER) and CRISPR/Cas9 system (PER-CRISPR/Cas9-E) was established for the sensitive detection of dual microRNAs (miRNAs). Two PER hairpin (HP) were designed to produce a lot of extended PER products, which could hybridize with two kinds of hairpin probes modified on the electrode and initiate the cleavage of two CRISPR/Cas9 systems guided by single guide RNAs (sgRNAs) with different recognition sequences. The decrease of the two electrochemical redox signals indicated the presence of dual-target miRNAs. With the robustness and high specificity of PER amplification and CRISPR/Cas9 cleavage system, simultaneous detection of two targets was achieved and the detection limits for miRNA-21 and miRNA-155 were 0.43 fM and 0.12 fM, respectively. The developed biosensor has the advantages of low cost, easy operation, and in-situ detection, providing a promising platform for point-of-care detection of multiple miRNAs.


Subject(s)
Biosensing Techniques , CRISPR-Cas Systems , Electrochemical Techniques , Limit of Detection , MicroRNAs , MicroRNAs/analysis , MicroRNAs/genetics , CRISPR-Cas Systems/genetics , Electrochemical Techniques/methods , Biosensing Techniques/methods , Humans , RNA, Guide, CRISPR-Cas Systems/genetics
3.
Biosensors (Basel) ; 14(7)2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39056617

ABSTRACT

The selection of an appropriate transducer is a key element in biosensor development. Currently, a wide variety of substrates and working electrode materials utilizing different fabrication techniques are used in the field of biosensors. In the frame of this study, the following three specific material configurations with gold-finish layers were investigated regarding their efficacy to be used as electrochemical (EC) biosensors: (I) a silicone-based sensor substrate with a layer configuration of 50 nm SiO/50 nm SiN/100 nm Au/30-50 nm WTi/140 nm SiO/bulk Si); (II) polyethylene naphthalate (PEN) with a gold inkjet-printed layer; and (III) polyethylene terephthalate (PET) with a screen-printed gold layer. Electrodes were characterized using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) to evaluate their performance as electrochemical transducers in an aptamer-based biosensor for the detection of cardiac troponin I using the redox molecule hexacyanoferrade/hexacyaniferrade (K3[Fe (CN)6]/K4[Fe (CN)6]. Baseline signals were obtained from clean electrodes after a specific cleaning procedure and after functionalization with the thiolate cardiac troponin I aptamers "Tro4" and "Tro6". With the goal of improving the PEN-based and PET-based performance, sintered PEN-based samples and PET-based samples with a carbon or silver layer under the gold were studied. The effect of a high number of immobilized aptamers will be tested in further work using the PEN-based sample. In this study, the charge-transfer resistance (Rct), anodic peak height (Ipa), cathodic peak height (Ipc) and peak separation (∆E) were determined. The PEN-based electrodes demonstrated better biosensor properties such as lower initial Rct values, a greater change in Rct after the immobilization of the Tro4 aptamer on its surface, higher Ipc and Ipa values and lower ∆E, which correlated with a higher number of immobilized aptamers compared with the other two types of samples functionalized using the same procedure.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Electrochemical Techniques , Electrodes , Gold , Gold/chemistry , Dielectric Spectroscopy , Transducers , Troponin I/analysis
4.
J Nanobiotechnology ; 22(1): 414, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39010059

ABSTRACT

Staphylococcus aureus (SA) poses a serious risk to human and animal health, necessitating a low-cost and high-performance analytical platform for point-of-care diagnostics. Cellulose paper-based field-effect transistors (FETs) with RNA-cleaving DNAzymes (RCDs) can fulfill the low-cost requirements, however, its high hydrophilicity and lipophilicity hinder biochemical modification and result in low sensitivity, poor mechanical stability and poor fouling performance. Herein, we proposed a controllable self-cleaning FET to simplify biochemical modification and improve mechanical stability and antifouling performance. Then, we constructed an RCD-based DNA nanotree to significantly enhance the sensitivity for SA detection. For controllable self-cleaning FET, 1 H,1 H,2 H,2 H-perfluorodecyltrimethoxysilane based-polymeric nanoparticles were synthesized to decorate cellulose paper and whole carbon nanofilm wires. O2 plasma was applied to regulate to reduce fluorocarbon chain density, and then control the hydrophobic-oleophobic property in sensitive areas. Because negatively charged DNA affected the sensitivity of semiconducting FETs, three Y-shaped branches with low-cost were designed and applied to synthesize an RCD-based DNA-Nanotree based on similar DNA-origami technology, which further improved the sensitivity. The trunk of DNA-Nanotree was composed of RCD, and the canopy was self-assembled using multiple Y-shaped branches. The controllable self-cleaning FET biosensor was applied for SA detection without cultivation, which had a wide linear range from 1 to 105 CFU/mL and could detect a low value of 1 CFU/mL.


Subject(s)
Biosensing Techniques , DNA, Catalytic , Staphylococcus aureus , DNA, Catalytic/chemistry , DNA, Catalytic/metabolism , Biosensing Techniques/methods , Transistors, Electronic , RNA/metabolism , Limit of Detection , Cellulose/chemistry , Paper , Nanoparticles/chemistry , Humans
5.
Biosens Bioelectron ; 262: 116550, 2024 Oct 15.
Article in English | MEDLINE | ID: mdl-38976958

ABSTRACT

Circulating tumor cell (CTC) has been a valuable biomarker for the diagnosis of breast cancer, while folate receptor is a kind of cell surface receptor glycoprotein which is overexpressed in breast cancer. In this work, we have designed and fabricated an electrochemical biosensor for sensitive detection of folate receptor-positive CTCs based on mild reduction assisted CRISPR/Cas system. Specifically, folate functionalized magnetic beads are firstly prepared to capture CTCs owing to the strong affinity between folate and the folate receptors on the surface of cells. Then, the cell membranes are treated by mild reduction so as to expose a large number of free sulfhydryl groups, which can be coupled with maleimide-DNA to introduce the signal amplified CRISPR/Cas12a system. After the trans-cleavage activity of CRISPR/Cas12a is activated, the long chain DNA modified with electroactive molecules methylene blue can be randomly cleaved into short DNA fragments, which are then captured on the graphite electrode through the host-guest recognition with cucurbit [7]uril, generating highly amplified electrochemical signal corresponding to the number of CTCs. The electrochemical biosensor not only demonstrates the sensitivity with a low detection limit of 2 cells/mL, but also highlights its excellent selectivity and stability in complex environment. Therefore, our biosensor may provide an alternative tool for the analysis of CTCs.


Subject(s)
Biosensing Techniques , CRISPR-Cas Systems , Electrochemical Techniques , Limit of Detection , Neoplastic Cells, Circulating , Humans , Biosensing Techniques/methods , Neoplastic Cells, Circulating/pathology , Neoplastic Cells, Circulating/chemistry , Electrochemical Techniques/methods , Breast Neoplasms/blood , Breast Neoplasms/diagnosis , Breast Neoplasms/pathology , Female , Cell Line, Tumor , Folic Acid/chemistry , DNA/chemistry
6.
Biosens Bioelectron ; 262: 116568, 2024 Oct 15.
Article in English | MEDLINE | ID: mdl-39003919

ABSTRACT

In this study, a dual-mode biosensor based on the heterojunction of Cu2O@Cu2S/D-TA COF was constructed for ultra-sensitive detection of Hg2+ using both photoelectrochemical and electrochemical approaches. Briefly, a 2D ultra-thin covalent organic framework film (D-TA COF film) with excellent photoelectrochemical signals was prepared on ITO surfaces through an in situ growth method. Subsequently, the probe H1 was immobilized onto the biosensor via Au-S bonds. In the presence of Hg2+, the formation of T-Hg2+-T complexes triggered hybridization chain reactions (HCR), leading to the attachment of abundant Cu2O@Cu2S probes onto the biosensor. As a p-type semiconductor, Cu2O@Cu2S could form a heterojunction with the underlying D-TA COF films. Meanwhile, it exhibited catalase-like activity, and the O2 produced by its catalytic decomposition of H2O2 can interact with the D-TA COF films, thus achieving double amplification of the photocurrent signal. Benefiting from the excellent and inherent Cu2+/Cu+ redox pairs of Cu2O@Cu2S, satisfactory differential pulse voltammetry (DPV) signals were obtained. As expected, the dual-mode biosensor was realized with wider linear ranges and low detection limits. Additionally, the analytical performance for Hg2+ in real water samples was excellent. Briefly, this suggested approach offers a facile and highly efficient modality for monitoring heavy metal ions in aquatic environments.


Subject(s)
Biosensing Techniques , Catalase , Copper , Electrochemical Techniques , Limit of Detection , Mercury , Metal-Organic Frameworks , Biosensing Techniques/methods , Copper/chemistry , Mercury/analysis , Mercury/chemistry , Electrochemical Techniques/methods , Metal-Organic Frameworks/chemistry , Catalase/chemistry , Water Pollutants, Chemical/analysis , Hydrogen Peroxide/chemistry , Sulfides
7.
Mikrochim Acta ; 191(8): 472, 2024 07 19.
Article in English | MEDLINE | ID: mdl-39028442

ABSTRACT

A Ti3C2TxMXene-based biosensor has been developed and the photocatalytic atom transfer radical polymerization (photo ATRP) amplification strategy applied to detect target miRNA-21 (tRNA). Initially, Ti3C2TxMXene nanosheets were synthesized from the Ti3AlC2 MAX precursor via selective aluminum etching. Then, functionalization of Ti3C2TxMXene nanosheets with 3-aminopropyl triethoxysilane (APTES) via silylation reactions to facilitate covalent bonding with hairpin DNA biomolecules specifically designed for tRNA detection. Upon binding with the tRNA, the hairpin DNA liberated the azide (N3) group, initiating a click reaction to affix to the photo ATRP initiator. Through the ATRP photoreaction, facilitated by an organic photoredox catalyst and light, a significant amount of ferrocenyl methyl methacrylate (FMMA) monomer was immobilized on the electrode. Therefore, the electrochemical signal is amplified. The electrochemical efficacy of the biosensor was assessed using square wave voltammetry (SWV). Under optimized conditions, the biosensor demonstrated remarkable sensitivity in detecting tRNA, with a linear detection range from 0.01 fM to 10 pM and a detection limit of 2.81 aM. The findings elucidate that the developed biosensor, in conjunction with the photo ATRP strategy, offers reproducibility, stability, and increased sensitivity, underscoring its potential applications within the experimental medical sector of the biomolecular industry.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Limit of Detection , MicroRNAs , Titanium , Biosensing Techniques/methods , MicroRNAs/analysis , Electrochemical Techniques/methods , Titanium/chemistry , Catalysis , Photochemical Processes , Humans , Polymerization , Silanes/chemistry
8.
Food Chem ; 459: 140379, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38991437

ABSTRACT

Precisely detecting organophosphorus pesticides (OPs) is paramount in upholding human safety and environmental preservation, especially in food safety. Herein, an electrochemical acetylcholinesterase (AChE) sensing platform entrapped in chitosan (Chit) on the glassy carbon electrodes (GCEs) decorated with Pt/MoS2/Ti3C2 MXene (Pt/MoS2/TM) was constructed for the detection of chlorpyrifos. It is worth noting that Pt/MoS2/TM possesses good biocompatibility, remarkable electrical conductivity, environmental stability and large specific surface area. Besides, the heterostructure formed by the composite of TM and MoS2 improves the conductivity and maintains the original structure, which is conducive to improving the electrochemical property. The coordination effect between the individual components enables the even distribution of functional components and enhances the electrochemical performance of the biosensor (AChE-Chit/Pt/MoS2/TM). Under optimal efficiency and sensitivity, the AChE-Chit/Pt/MoS2/TM/GCE sensing platform exerts comparable analytical performance and a wide concentration range of chlorpyrifos from 10-12 to 10-6 M as well as a low limit of detection (4.71 × 10-13 M). Furthermore, the biosensor is utilized to detect OPs concerning three kinds of fruits and vegetables with good feasibility and recoveries (94.81% to 104.0%). This work would provide a new scheme to develop high-sensitivity sensors based on the two-dimensional nanosheet/laminar hybrid structure for practical applications in environmental monitoring and agricultural product detection.

9.
Mikrochim Acta ; 191(8): 456, 2024 07 09.
Article in English | MEDLINE | ID: mdl-38980419

ABSTRACT

Polydopamine (PDA) has garnered significant interest for applications in biosensors, drug delivery, and tissue engineering. However, similar polycatecholamines like polynorepinephrine (PNE) with additional hydroxyl groups and poly-α-methylnorepinephrine (PAMN) with additional hydroxyl and methyl groups remain unexplored in the biosensing domain. This research introduces three innovative biosensing platforms composed of ternary nanocomposite based on reduced graphene oxide (RGO), gold nanoparticles (Au NPs), and three sister polycatecholamine compounds (PDA, PNE, and PAMN). The study compares and evaluates the performance of the three biosensing systems for the ultrasensitive detection of Mycobacterium tuberculosis (MTB). The formation of the nanocomposites was meticulously examined through UV-Visible, Raman, XRD, and FT-IR studies with FE-SEM and HR-TEM analysis. Cyclic voltammetry and differential pulse voltammetry measurements were also performed to determine the electrochemical characteristics of the modified electrodes. Electrochemical biosensing experiments reveal that the RGO-PDA-Au, RGO-PNE-Au, and RGO-PAMN-Au-based biosensors detected target DNA up to a broad detection range of 0.1 × 10-8 to 0.1 × 10-18 M, with a low detection limit (LOD) of 0.1 × 10-18, 0.1 × 10-16, and 0.1 × 10-17 M, respectively. The bioelectrodes were proved to be highly selective with excellent sensitivities of 3.62 × 10-4 mA M-1 (PDA), 7.08 × 10-4 mA M-1 (PNE), and 6.03 × 10-4 mA M-1 (PAMN). This study pioneers the exploration of two novel mussel-inspired polycatecholamines in biosensors, opening avenues for functional nanocoatings that could drive further advancements in this field.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Gold , Graphite , Indoles , Limit of Detection , Metal Nanoparticles , Polymers , Biosensing Techniques/methods , Indoles/chemistry , Polymers/chemistry , Electrochemical Techniques/methods , Graphite/chemistry , Gold/chemistry , Animals , Metal Nanoparticles/chemistry , Mycobacterium tuberculosis , Bivalvia/chemistry , Nanocomposites/chemistry , Electrodes , Norepinephrine/analysis
10.
Mikrochim Acta ; 191(8): 460, 2024 07 10.
Article in English | MEDLINE | ID: mdl-38987355

ABSTRACT

The facile sonochemical synthesis is reported of zinc cobalt oxide (ZnCo2O4) composited with carbon nanofiber (CNF). Structural, chemical, and morphological were characterized by X-ray diffraction (XRD), X-ray photoluminescent spectroscopy (XPS), field emission scanning electron microscopy (FESEM), and transmittance electron microscopy (TEM), respectively. ZnCo2O4/CNF-modified GCE was applied to the detection of bisphenol A (BPA). The modified GCE shows enhanced sensing performance towards BPA, which includes a linear range (0.2 to 120 µM L-1) alongside a low limit of detection (38.2 nM L-1), low interference, and good stability. Detection of lower concentrations of BPA enables real sample analysis in the food industries (milk, orange juice, yogurt, tap water, and baby feeding bottles). Surprisingly, the BPA was detected in milk 510 nM L-1, orange juice 340 nM L-1, yogurt 1050 nM L-1, and tap water 140 nM L-1. Moreover, an interaction mechanism between the BPA analyte and ZnCo2O4 was discussed.


Subject(s)
Benzhydryl Compounds , Carbon , Cobalt , Milk , Nanofibers , Phenols , Benzhydryl Compounds/analysis , Phenols/analysis , Phenols/chemistry , Cobalt/chemistry , Carbon/chemistry , Milk/chemistry , Nanofibers/chemistry , Food Contamination/analysis , Animals , Oxides/chemistry , Limit of Detection , Electrochemical Techniques/methods , Fruit and Vegetable Juices/analysis , Green Chemistry Technology/methods , Yogurt/analysis
11.
Polymers (Basel) ; 16(13)2024 Jun 24.
Article in English | MEDLINE | ID: mdl-39000638

ABSTRACT

Lead (Pb) is a hazardous metal that poses a significant threat to both the environment and human health. The presence of Pb in food products such as honey can pose a significant risk to human health and is therefore important to detect and monitor. In this study, we propose a voltammetric detection method using molecularly imprinted polymer (MIP) electrodes to detect Pb (II) ions in honey. Pb (II) ion-imprinted amino acid-based nanoparticles with magnetic properties on a carbon paste electrode (MIP-CPE) were designed to have high sensitivity and selectivity towards Pb (II) ions in the honey sample. Zetasizer measurements, electron spin resonance, and scanning electron microscopy were used to characterize magnetic polymeric nanoparticles. The results showed that the voltammetric detection method using MIP-CPE was able to accurately detect Pb (II) ions in honey samples with a low detection limit. The proposed method offers a simple, rapid, cost-effective solution for detecting Pb (II) ions in honey. It could potentially be applied to other food products to ensure their safety for human consumption. The MIP-CPE sensor was designed to have high sensitivity and selectivity towards Pb (II) ions in the honey sample. The results showed that the technique was able to deliver highly sensitive results since seven different concentrations were prepared and detected to obtain an R2 of 0.9954, in addition to a low detection limit (LOD) of 0.0912 µM and a low quantification limit (LOQ) of 0.276 µM. Importantly, the analysis revealed no trace of Pb (II) ions in the honey samples obtained from Cyprus.

12.
Talanta ; 278: 126468, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38963975

ABSTRACT

Carcinoembryonic Antigen (CEA), an acidic glycoprotein with human embryonic antigen properties, is found on the surface of cancer cells that have differentiated from endodermal cells. This paper presents a label-free electrochemical immunoassay for the dual amplification detection of CEA using gold nanoparticles loaded with polypyrrole polydopamine (Au/PPy-PDA) and polymerized polycaprolactone (Ng-PCL) prepared by ring-opening polymerization (ROP). First, the composite Au/PPy-PDA was adhered to the electrode surface. Then, gold nanoparticles form a Au-S bond with the sulfhydryl group in Apt1 to secure it on the electrode surface. Subsequently, the non-specific binding sites on the electrodes surface are closed by bovine serum albumin (BSA). Next, CEA is dropped onto the electrode surface, which is immobilized by antigen-antibody specific recognition, and the carboxyl-functionalized Apt2 forms a "sandwich structure" of antibody-antigen-antibody by specific recognition. Polymeric Ng-PCL is adhered to the electrode surface, leading to an increase in the electrochemical impedance signal, resulting in a complete chain of signal analysis. Finally, the response signal is detected by electrochemical impedance spectroscopy (EIS). Under optimal experimental conditions, the method has the advantages of high sensitivity and wide linear range (1 pg mL-1∼100 ng mL-1), and the lower limit of detection (LOD) is 0.234 pg mL-1. And it has the same high sensitivity, selectivity and interference resistance for the real samples detection. Thus, it provides a new way of thinking about biomedical and clinical diagnosis.

13.
Anal Chim Acta ; 1317: 342902, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39030006

ABSTRACT

BACKGROUND: Given the importance of achieving optimal therapeutical concentration in patients treated with antidepressants, this study investigates a novel technique for the simultaneous determination of trazodone (TRZ) and doxepin (DOX) in human plasma and serum samples for the first time. RESULTS: To achieve simultaneous determination of two antidepressants, TRZ and DOX, a novel detection system was designed: a non-enzymatic voltammetric biosensor based on boron-reduced graphene oxide/manganese oxide nanoparticles (GCE/B-rGO/MnO NPs). The detection was accomplished after pre-concentration and extraction trace amounts of the analytes using the thin film-solid phase microextraction (TF-SPME) technique, which employed polyvinyl alcohol/polyvinyl acetate/copper oxide nanoparticles (PVA/PVAc/CuO NPs) electrospun nanofibers. The successful preparation of composite nanofibers and modified electrodes was confirmed using the evaluation of field emission-scanning electron microscopy (FE-SEM) and energy-dispersive X-ray spectroscopy (EDX). Also, the composite nanofibers were characterized with attenuated total reflectance-Fourier transform-infrared (ATR-FT-IR) and X-ray diffraction (XRD). In the solution of TRZ and DOX, under optimum experimental conditions, the linear dynamic ranges (LDRs) were 0.1-20.0 µmol L-1 and 0.5-27.0 µmol L-1, respectively. Also, the limit of detection (LOD) values of TRZ and DOX were 0.032 and 0.150 µmol L-1. SIGNIFICANCE: PVAc acts as a cross-linking agent for PVA, and their mixture is effective for sample preparation and pre-concentration of analytes in complex matrices. Also, adding CuO NPs to this polymeric mixture enhanced the adsorption efficiency. Taking advantage of the high surface area of MnO NPs and the high electrical conductivity of B-rGO, and considering the superiority of their simultaneous utilization, the constructed electrochemical biosensor is both cost-effective and rapid. It demonstrates excellent stability, repeatability, and sensitivity for the simultaneous determination of TRZ and DOX under optimal conditions. This biosensor, the first of its kind, is specifically designed for the simultaneous determination of TRZ and DOX in human plasma and serum samples, representing a significant advancement in biosensing technology.


Subject(s)
Biosensing Techniques , Doxepin , Electrochemical Techniques , Graphite , Trazodone , Humans , Doxepin/blood , Doxepin/isolation & purification , Doxepin/chemistry , Doxepin/analysis , Graphite/chemistry , Biosensing Techniques/methods , Trazodone/blood , Trazodone/analysis , Trazodone/isolation & purification , Trazodone/chemistry , Oxides/chemistry , Manganese Compounds/chemistry , Solid Phase Microextraction/methods , Limit of Detection , Copper/chemistry , Copper/blood , Adsorption
14.
Mikrochim Acta ; 191(7): 431, 2024 06 29.
Article in English | MEDLINE | ID: mdl-38951263

ABSTRACT

A signal amplification electrochemical biosensor chip was developed to integrate loop-mediated isothermal amplification (LAMP) based on in situ nucleic acid amplification and methyl blue (MB) serving as the hybridization redox indicator for sensitive and selective foodborne pathogen detection without a washing step. The electrochemical biosensor chip was designed by a screen-printed carbon electrode modified with gold nanoparticles (Au NPs) and covered with polydimethylsiloxane membrane to form a microcell. The primers of the target were immobilized on the Au NPs by covalent attachment for in situ amplification. The electroactive MB was used as the electrochemical signal reporter and embedded into the double-stranded DNA (dsDNA) amplicons generated by LAMP. Differential pulse voltammetry was introduced to survey the dsDNA hybridization with MB, which differentiates the specifically electrode-unbound and -bound labels without a washing step. Pyrene as the back-filling agent can further improve response signaling by reducing non-specific adsorption. This method is operationally simple, specific, and effective. The biosensor showed a detection linear range of 102-107 CFU mL-1 with the limit of detection of 17.7 CFU mL-1 within 40 min. This method showed promise for on-site testing of foodborne pathogens and could be integrated into an all-in-one device.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Food Microbiology , Gold , Metal Nanoparticles , Nucleic Acid Amplification Techniques , Nucleic Acid Amplification Techniques/methods , Electrochemical Techniques/methods , Biosensing Techniques/methods , Gold/chemistry , Metal Nanoparticles/chemistry , Limit of Detection , Electrodes , DNA, Bacterial/analysis , DNA, Bacterial/genetics , Nucleic Acid Hybridization
15.
Food Res Int ; 191: 114727, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39059923

ABSTRACT

Phages are a class of viruses that specifically infect host bacteria. Compared to other recognition elements, phages offer several advantages such as high specificity, easy to obtain and good environmental tolerance, etc. These advantages underscore the potential of phages as recognition elements in the construction of biosensors. Therefore, the phage-based biosensors are currently garnering widespread attention for detecting pathogens in recent years. However, the test performance such as detection limit, sensitivity and stability of exicting phage-based biosensors require enhancement. In the design of sensors, the selection of various materials and construction methods significantly influences the test performance of the sensor, and employing appropriate signal amplification strategies and construction methods to devise biosensors based on different principles is an effective strategy to enhance sensor performance. The manuscript primarily focuses on the signal amplification strategies and construction methods employed in phage-based biosensors recent ten years, and summarizes the advantages and disadvantages of different signal amplification strategies and construction methods. Meanwhile, the manuscript discusses the relationship between sensor performance and various materials and construction methods, and reviews the application progress of phage-based electrochemical biosensors in the detection of foodborne bacteria. Furthermore, the manuscript points out the present limitations and the future research direction for the field of phage-based biosensors, so as to provide the reference for developing high-performance phage-based biosensors.


Subject(s)
Bacteriophages , Biosensing Techniques , Food Microbiology , Biosensing Techniques/methods , Food Microbiology/methods , Bacteria/virology , Bacteria/isolation & purification , Electrochemical Techniques/methods
16.
Sci Rep ; 14(1): 17172, 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39060466

ABSTRACT

The combination of copper-metal organic framework (Cu-MOF) with graphene oxide (GO) has received growing interest in electrocatalysis, energy storage and sensing applications. However, its potential as an electrochemical biosensing platform remains largely unexplored. In this study, we introduce the synthesis of GO/Cu-MOF nanocomposite and its application in the simultaneous detection of two biomarkers associated with lower respiratory infections, marking the first instance of its use in this capacity. The physicochemical properties and structural elucidation of this composite were studied with the support of XRD, FTIR, SEM and electrochemical techniques. The immunosensor was fabricated by drop casting the nanocomposite on dual screen-printed electrodes followed by functionalization with pyrene linker. The covalent immobilization of the monoclonal antibodies of the bacterial antigens of Mycoplasma pneumoniae (M. pneumoniae; M. p.) and Legionella pneumophila (L. pneumophila; L. p.) was achieved using EDC-NHS chemistry. The differential pulse voltammetry (DPV) signals of the developed immunosensor platform demonstrated a robust correlation across a broad concentration range from 1 pg/mL to 100 ng/mL. The immunosensor platform has shown high degree of selectivity against antigens for various respiratory pathogens. Moreover, the dual immunosensor was successfully applied for the detection of M. pneumoniae and L. pneumophila antigens in spiked water samples showing excellent recovery percentages. We attribute the high sensitivity of the immunosensor to the enhanced electrocatalytic characteristics, stability and conductivity of the GO-MOF composite as well as the synergistic interactions between the GO and MOF. This immunosensor offers a swift analytical response, simplicity in fabrication and instrumentation, rendering it an appealing platform for the on-field monitoring of pathogens in environmental samples.


Subject(s)
Antigens, Bacterial , Biosensing Techniques , Copper , Electrochemical Techniques , Graphite , Legionella pneumophila , Metal-Organic Frameworks , Mycoplasma pneumoniae , Legionella pneumophila/immunology , Legionella pneumophila/isolation & purification , Mycoplasma pneumoniae/immunology , Mycoplasma pneumoniae/isolation & purification , Graphite/chemistry , Electrochemical Techniques/methods , Biosensing Techniques/methods , Copper/chemistry , Metal-Organic Frameworks/chemistry , Antigens, Bacterial/immunology , Antigens, Bacterial/analysis , Immunoassay/methods , Water Microbiology , Nanocomposites/chemistry
17.
Bioanalysis ; : 1-4, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949192

ABSTRACT

GRAPHICAL ABSTRACT[Formula: see text].

18.
Anal Chim Acta ; 1316: 342828, 2024 Aug 08.
Article in English | MEDLINE | ID: mdl-38969425

ABSTRACT

BACKGROUD: The global prevalence of diabetes mellitus, a serious chronic disease with fatal consequences for millions annually, is of utmost concern. The development of efficient and simple devices for monitoring glucose levels is of utmost significance in managing diabetes. The advancement of nanotechnology has resulted in the indispensable utilization of advanced nanomaterials in high-performance glucose sensors. Modulating the morphology and intricate composition of transition metals represents a viable approach to exploit their structure/function correlation, thereby achieving optimal electrocatalytic performance of the synthesized catalysts. RESULTS: Herein, a sensitive and rapid Cu-encapsulated Cu2S@nitrogen-doped carbon (Cu@Cu2S@N-C) hollow nanocubes-functionalized microfluidic paper-based analytical device (µ-PAD) was fabricated. Through a delicate sacrificial template/interface technique and thermal decomposition, inter-connected hollow networks were formed to boost the active sites, and the carbon shell was coated to protect Cu from being oxidation. For application, the constructed µ-PAD is used for glucose sensing utilizing an origami automated sample pretreatment system enabled by a simple application of strong alkaline solution on wax paper. Under optimal circumstances, the Cu@Cu2S@N-C electrochemical biosensor exhibits broad detection range of 2-7500 µM (R2 = 0.996) with low detection limit of 0.16 µM (S/N = 3) and high sensitivity of 1996 µA mM-1 cm-2. Additionally, the constructed µ-PAD also exhibited excellent selectivity, stability, and reproducibility. SIGNIFICANCE: By rationally designing the double-shell hollow nanostructure and introducing Cu-encapsulated inner layer, the synthesized Cu@Cu2S@N-C hollow nanocubes show large specific surface area, short diffusion channels, and high stability. The proposed origami µ-PAD has been successfully applied to serum samples without any additional sample preparation steps for glucose determination, offering a new perspective for early nonenzymatic glucose diagnosis.

19.
Front Bioeng Biotechnol ; 12: 1427229, 2024.
Article in English | MEDLINE | ID: mdl-39045538

ABSTRACT

Polydopamine nanoparticles (PDA NPs) are widely utilized in the field of biomedical science for surface functionalization because of their unique characteristics, such as simple and low-cost preparation methods, good adhesive properties, and ability to incorporate amine and oxygen-rich chemical groups. However, challenges in the application of PDA NPs as surface coatings on electrode surfaces and in conjugation with biomolecules for electrochemical sensors still exist. In this work, we aimed to develop an electrochemical interface based on PDA NPs conjugated with a DNA aptamer for the detection of glycated albumin (GA) and to study DNA aptamers on the surfaces of PDA NPs to understand the aptamer-PDA surface interactions using molecular dynamics (MD) simulation. PDA NPs were synthesized by the oxidation of dopamine in Tris buffer at pH 10.5, conjugated with DNA aptamers specific to GA at different concentrations (0.05, 0.5, and 5 µM), and deposited on screen-printed carbon electrodes (SPCEs). The charge transfer resistance of the PDA NP-coated SPCEs decreased, indicating that the PDA NP composite is a conductive bioorganic material. Transmission electron microscopy (TEM) and scanning electron microscopy (SEM) confirmed that the PDA NPs were spherical, and dynamic light scattering (DLS), Fourier transform infrared spectroscopy (FTIR), and Raman spectroscopy data indicated the successful conjugation of the aptamers on the PDA NPs. The as-prepared electrochemical interface was employed for the detection of GA. The detection limit was 0.17 µg/mL. For MD simulation, anti-GA aptamer through the 5'terminal end in a single-stranded DNA-aptamer structure and NH2 linker showed a stable structure with its axis perpendicular to the PDA surface. These findings provide insights into improved biosensor design and have demonstrated the potential for employing electrochemical PDA NP interfaces in point-of-care applications.

20.
Diagnostics (Basel) ; 14(11)2024 May 24.
Article in English | MEDLINE | ID: mdl-38893615

ABSTRACT

Saliva has shown considerable promise as a diagnostic medium for point-of-care (POC) and over-the-counter (OTC) diagnostic devices due to the non-invasive nature of its collection. However, a significant limitation of saliva-based detection is undesirable interference in a sensor's readout caused by interfering components in saliva. In this study, we develop standardized sample treatment procedures to eliminate bubbles and interfering molecules while preserving the sample's target molecules such as spike (S) protein and glucose. We then test the compatibility of the pretreatment system with our previously designed SARS-CoV-2 and glucose diagnostic biosensing systems for detecting S protein and glucose in subject saliva. Ultimately, the effectiveness of each filter in enhancing biomarker sensitivity is assessed. The results show that a 20 mg nylon wool (NW) filter shows an 80% change in viscosity reduction with only a 6% reduction in protein content, making it an appropriate filter for the salivary S protein diagnostic system. Meanwhile, a 30 mg cotton wool (CW) filter is identified as the optimal choice for salivary glucose detection, achieving a 90% change in viscosity reduction and a 60.7% reduction in protein content with a minimal 4.3% reduction in glucose content. The NW pretreatment filtration significantly improves the limit of detection (LOD) for salivary S protein detection by five times (from 0.5 nM to 0.1 nM) and it reduces the relative standard deviation (RSD) two times compared to unfiltered saliva. Conversely, the CW filter used for salivary glucose detection demonstrated improved linearity with an R2 of 0.99 and a sensitivity of 36.6 µA/mM·cm2, over twice as high as unfiltered saliva. This unique filtration process can be extended to any POC diagnostic system and optimized for any biomarker detection, making electrochemical POC diagnostics more viable in the current market.

SELECTION OF CITATIONS
SEARCH DETAIL