Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 118
Filter
1.
Biomed Chromatogr ; 38(1): e5762, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37845823

ABSTRACT

A simple external calibration liquid chromatography-diode array detector method was developed, validated, and applied for the determination of lumefantrine (Lum) in dried blood spot (DBS) samples collected from malaria patients in Botswana. The samples were validated in accordance with the United States Food and Drug Administration guidelines for bioanalytical methods after sample preparation using solid-liquid extraction. Separation was achieved using an XTerra C18 column (50 × 4.6 mm, 5 µm), and a binary solvent system of acetonitrile and water adjusted to pH 2.3 was used as the mobile phase. The validated method was applied for the determination of Lum in DBS samples collected from malaria patients infected with Plasmodium falciparum in Botswana. The calibration curve was linear between 0.5 and 12 µg/mL with a coefficient of determination (R2 ) of 0.9996. The limit of detection and the lower limit of quantification were 0.5 and 1.4 µg/mL, respectively. The efficiency of extraction measured as percentage recovery ranged between 84.2% and 107.8% at the three quality control (QC) levels, that is, low QC, mid QC, and high QC. In conclusion, data suggest that the method is suitable for the determination of trace Lum in biofluids and can also be used for therapeutic drug monitoring and pharmacokinetic profiling.


Subject(s)
Malaria , Humans , Lumefantrine , Chromatography, High Pressure Liquid/methods , Calibration , Botswana
2.
J Mass Spectrom Adv Clin Lab ; 28: 35-46, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36872954

ABSTRACT

The emerging disciplines of lipidomics and metabolomics show great potential for the discovery of diagnostic biomarkers, but appropriate pre-analytical sample-handling procedures are critical because several analytes are prone to ex vivo distortions during sample collection. To test how the intermediate storage temperature and storage period of plasma samples from K3EDTA whole-blood collection tubes affect analyte concentrations, we assessed samples from non-fasting healthy volunteers (n = 9) for a broad spectrum of metabolites, including lipids and lipid mediators, using a well-established LC-MS-based platform. We used a fold change-based approach as a relative measure of analyte stability to evaluate 489 analytes, employing a combination of targeted LC-MS/MS and LC-HRMS screening. The concentrations of many analytes were found to be reliable, often justifying less strict sample handling; however, certain analytes were unstable, supporting the need for meticulous processing. We make four data-driven recommendations for sample-handling protocols with varying degrees of stringency, based on the maximum number of analytes and the feasibility of routine clinical implementation. These protocols also enable the simple evaluation of biomarker candidates based on their analyte-specific vulnerability to ex vivo distortions. In summary, pre-analytical sample handling has a major effect on the suitability of certain metabolites as biomarkers, including several lipids and lipid mediators. Our sample-handling recommendations will increase the reliability and quality of samples when such metabolites are necessary for routine clinical diagnosis.

3.
Toxicol Rep ; 10: 357-366, 2023.
Article in English | MEDLINE | ID: mdl-36923444

ABSTRACT

Mucopolysaccharidosis Type IIIB (MPS IIIB) is an ultrarare, fatal pediatric disease with no approved therapy. It is caused by mutations in the gene encoding for lysosomal enzyme alpha-N-acetylglucosaminidase (NAGLU). Tralesinidase alfa (TA) is a fusion protein comprised of recombinant NAGLU and a modified human insulin-like growth factor 2 that is being developed as an enzyme replacement therapy for MPS IIIB. Since MPS IIIB is a pediatric disease the safety/toxicity, pharmacokinetics and biodistribution of TA were evaluated in juvenile non-human primates that were administered up to 5 weekly intracerebroventricular (ICV) or single intravenous (IV) infusions of TA. TA administered by ICV slow-, ICV isovolumetric bolus- or IV-infusion was well-tolerated, and no effects were observed on clinical observations, electrocardiographic or ophthalmologic parameters, or respiratory rates. The drug-related changes observed were limited to increased cell infiltrates in the CSF and along the ICV catheter track after ICV administration. These findings were not associated with functional changes and are associated with the use of ICV catheters. The CSF PK profiles were consistent across all conditions tested and TA distributed widely in the CNS after ICV administration. Anti-drug antibodies were observed but did not appear to significantly affect the exposure to TA. Correlations between TA concentrations in plasma and brain regions in direct contact with the cisterna magna suggest glymphatic drainage may be responsible for clearance of TA from the CNS. The data support the administration of TA by isovolumetric bolus ICV infusion to pediatric patients with MPS IIIB.

4.
JHEP Rep ; 5(3): 100646, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36748051

ABSTRACT

Background & Aims: Elimination of chronic HBV/HDV infection remains a major global health challenge. Targeting excessive hepatitis B surface antigen (HBsAg) release may provide an interesting window of opportunity to break immune tolerance and to achieve a functional cure using additional antivirals. Methods: We evaluated a HBsAg-specific human monoclonal antibody, as part of either a prophylactic or therapeutic strategy, against HBV/HDV infection in cell culture models and in human-liver chimeric mice. To assess prophylactic efficacy, mice were passively immunized prior to infection with HBV or HBV/HDV (coinfection and superinfection setting). Therapeutic efficacy was assessed in HBV and HBV/HDV-coinfected mice receiving 4 weeks of treatment. Viral parameters (HBV DNA, HDV RNA and HBsAg) were assessed in mouse plasma. Results: The antibody could effectively prevent HBV/HDV infection in a dose-dependent manner with IC50 values of ∼3.5 ng/ml. Passive immunization showed complete protection of mice from both HBV and HBV/HDV coinfection. Moreover, HDV superinfection was either completely prevented or at least attenuated in HBV-infected mice. Finally, antibody treatment in mice with established HBV/HDV infection resulted in a significant decline in viremia and a concomitant drop in on-treatment HBsAg, with a moderate viral rebound following treatment cessation. Conclusion: We present data on a valuable antibody candidate that could complement other antivirals in strategies aimed at achieving functional cure of chronic HBV and HDV infection. Impact and implications: Patients chronically infected with HBV may eventually develop liver cancer and are at great risk of being superinfected with HDV, which worsens and accelerates disease progression. Unfortunately, current treatments can rarely eliminate both viruses from chronically infected patients. In this study, we present data on a novel antibody that is able to prevent chronic HBV/HDV infection in a mouse model with a humanized liver. Moreover, antibody treatment of HBV/HDV-infected mice strongly diminishes viral loads during therapy. This antibody is a valuable candidate for further clinical development.

5.
JHEP Rep ; 5(3): 100650, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36852107

ABSTRACT

Background & Aims: EASL guidelines recommend 8 weeks of treatment with sofosbuvir plus velpatasvir (SOF/VEL) for the treatment of acute or recently acquired HCV infection, but only 6- and 12-week data are available. Therefore, the aim of this study was to evaluate the safety and efficacy of a shortened 8-week SOF/VEL treatment for acute HCV monoinfection. Methods: In this investigator-initiated, prospective, multicentre, single-arm study, we recruited 20 adult patients with acute HCV monoinfection from nine centers in Germany. Patients received SOF/VEL (400/100 mg) as a fixed-dose combination tablet once daily for 8 weeks. The primary efficacy endpoint was the proportion of patients with sustained virological response 12 weeks after the end of treatment (SVR12). Results: The median HCV RNA viral load at baseline was 104,307 IU/ml; the distribution of HCV genotypes was as follows: GT1a/1b/2/3/4: n = 12/1/1/3/3. Thirteen (65%) of the 20 patients were taking medication for HIV pre-exposure prophylaxis. SVR12 was achieved in all patients who complied with the study protocol (n = 18/18 [100%], per protocol analysis), but the primary endpoint was not met in the intention-to-treat analysis (n = 18/20 [90%]) because two patients were lost to follow-up. One serious adverse event (unrelated to study drug) occurred during 12 weeks of post-treatment follow-up. Conclusions: The 8-week treatment with SOF/VEL was well tolerated and highly effective in all adherent patients with acute HCV monoinfection. Early treatment of hepatitis C might effectively prevent the spread of HCV in high-risk groups. Clinical Trial Number: NCT03818308. Impact and implications: The HepNet acute HCV-V study (NCT03818308), an investigator-initiated, single-arm, multicenter pilot study, demonstrates the efficacy and safety of 8 weeks of daily treatment with the fixed-dose combination sofosbuvir/velpatasvir (400/100 mg) in patients with acute hepatitis C virus (HCV) infection. All patients who completed therapy and were followed-up achieved sustained virologic response. Thus, early treatment with SOF/VEL which might effectively prevent the spread of HCV in high-risk groups can be recommended for patients with acute HCV monoinfection.

6.
Ann Biol Clin (Paris) ; 81(1): 44-51, 2023 03 15.
Article in English | MEDLINE | ID: mdl-36762454

ABSTRACT

Purpose: Measurement of the haemolysis index (HI) is usually performed in clinical chemistry laboratories in order to inform about whether biological analyses are influenced by in vivo or in vitro haemolysis of the specimen. Our aim was to evaluate the analytical performance of Abbott C-16000 analyser HI measurement in order to determine whether this could be used to reliably measure cell-free haemoglobin (fHB) in plasma samples. Methods: The repeatability, reproducibility, lower limit of detection (LLOD) and lower limit of quantification (LLOQ) of C-16000 HI measurement were determined as well as the potential interference of bilirubin, triglycerides and myoglobin. C-16000 HI values of biological samples with various ranges of fHB were compared to those measured using the established reference method, second-derivate spectroscopy. Results: Results: C-16000 HI determination showed excellent linear correlation with the reference method (y = 1.0043x ­ 1.248, R² = 0.998), a broad analytical measurement range (400-20,000 mg/L; y = 0.9904x + 72.972, R² = 0.999), clinically relevant LLOD (56 mg/L) and LLOQ (84 mg/L), good repeatability (coefficient of variation (CV) = 1-15%) and good reproducibility (CV = 5-7%). No interference was observed with myoglobin at concentrations as high as 35,447 mg/L, unconjugated and conjugated bilirubin (at concentrations up to 500 mg/L and 375 mg/L, respectively) or triglycerides up to 6.8 mmol/L. However, a significant underestimation of fHB concentrations was observed at higher triglyceride levels. Conclusion: This study demonstrates that Abbott C-16000 analyser HI is reliable and accurately measures plasma fHB concentrations under pathophysiological conditions except when there are high blood concentrations of triglycerides.


Subject(s)
Hemolysis , Myoglobin , Humans , Reproducibility of Results , Hemoglobins/analysis , Bilirubin , Triglycerides
7.
J Mass Spectrom Adv Clin Lab ; 27: 40-48, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36619216

ABSTRACT

Objectives: Highly selective and sensitive multi-analyte methods for the analysis of steroids are attractive for the diagnosis of endocrine diseases. Commercially available kits are increasingly used for this purpose. These methods involve laborious solid phase extraction, and the respective panels of target analytes are incomplete. We wanted to investigate whether an improvement of kit solutions is possible by introducing automated on-line solid phase extraction (SPE) and combining originally separate analyte panels. Methods: Sample preparation was performed using automated on-line SPE on a high-pressure stable extraction column. Chromatographic separation, including isobaric compounds, was achieved using a 0.25 mM ammonium fluoride-methanol gradient on a small particle size biphenyl column. Standard compounds and internal standard mixtures of two panels of a commercially available kit were combined to achieve an optimized and straightforward detection of 15 endogenous steroids. Validation was performed according to the European Medicines Agency (EMA) guidelines with slight modifications. Results: Validation was successfully performed for all steroids over a clinically relevant calibration range. Deviations of intra- and inter-assay accuracy and precision results passed the criteria and no relevant matrix effects were detected due to highly effective sample preparation. External quality assessment samples showed the applicability as a routine diagnostic method, which was affirmed by the analyses of anonymized clinical samples. Conclusions: It was found possible to complement a commercially available kit for quantitative serum steroid profiling based on isotope dilution LC-MS/MS by implementing automated on-line SPE, thereby improving the practicality and robustness of the measurement procedure.

8.
J Mass Spectrom Adv Clin Lab ; 27: 24-32, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36593910

ABSTRACT

Background: Steroids play a key role in numerous physiological processes. Steroid determination is a useful tool to explore various endocrine diseases. Because of its specificity, mass spectrometry is considered to be a reference method for the determination of steroids in serum compared to radioimmunoassay. This technology could progress towards more automation for the optimal organization of clinical laboratories and ultimately for the benefit of patients. Methods: A fully automated ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed and fully validated to determine five steroids in serum. Sample preparation was based on protein precipitation with filtration followed by online solid phase extraction. Chromatographic separation was performed using a biphenyl stationary phase. Results: The method was successfully validated according to European Medicine Agency guidelines. Coefficients of variation did not exceed, respectively, 8.4% and 8.1% for intra- and inter-assay precision. Method comparison with radioimmunoassay showed a proportional bias for all compounds, except for testosterone in men. Comparison with another LC-MS/MS method demonstrated acceptable concordance for all steroids, although a small bias was observed for androstenedione. Conclusion: The novelty of this method is that it has been fully automated. Automation provides benefits in traceability and allows significant savings in cost and time.

9.
J Mass Spectrom Adv Clin Lab ; 27: 56-60, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36685290

ABSTRACT

The need for high-throughput analysis of multiple analytes for inborn errors of metabolism in newborn screening (NBS) has led to the introduction of tandem mass spectrometry (MS/MS) into the NBS laboratory. In a flow-injection analysis (FIA), the predominant MS/MS method utilized for NBS, samples are introduced directly into the mass spectrometer without chromatographic separation. When a high-throughput FIA-based MS/MS method is implemented on newer generations of mass spectrometers with increased sensitivity, the risk of carryover and contamination increases. In the present study, we report the carryover of ornithine identified during the implementation of the NeoBase™ 2 (PerkinElmer) non-derivatized kits on the Xevo-TQD platform (Waters Corporation) and describe the source of the carryover, which was traced to the stainless-steel frit-type inline filter. Furthermore, a possible compound-dependent interaction with the stainless-steel frit is suggested based on the structure of ornithine and its effect on separation techniques. Investigation and mitigation of carryover can be a time and resource consuming process, and to this end, our report on identification of a stainless-steel frit as the source of delayed elution and carryover of ornithine should be recognized as a rare, albeit possible source of carryover in FIA-MS/MS methods adopted for NST.

10.
J Mass Spectrom Adv Clin Lab ; 27: 7-17, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36568714

ABSTRACT

Introduction: Adherence to medication is an important determinant of outcomes in chronic diseases like heart failure. Drug assays provide objective adherence biomarkers. Dried blood spots (DBS) are appealing samples for drug assays due to less demanding transportation and storage requirements. Objectives: To analytically validate a LC-MS/MS method for the simultaneous quantification of carvedilol, enalaprilat, and perindoprilat in DBS and evaluate the feasibility of using the method as an adherence determining assay. To validate the assay further clinically by establishing correlation and agreement between plasma and DBS samples from a pharmacokinetic pilot study. Methods: The method was validated over a concentration range of 1.00-200 ng/mL according to FDA guidelines. Adherence tracking ability of the assay was evaluated using a pharmacokinetic pilot study. Correlation and agreement were evaluated through Deming regression and Bland-Altman analysis, respectively. Results: Accuracy, precision, selectivity, and sensitivity were proven with complete and reproducible extraction recovery at all concentrations tested. Stability of the analytes in the matrix and throughout sample processing was proven. The full range of concentrations of the pharmacokinetic pilot study could be quantified for enalaprilat, but not for carvedilol and perindoprilat. The difference between the observed and calculated plasma concentrations was less than 20 % of their mean for >67 % of samples for all analytes. Conclusions: The assay is suitable as a screening tool for carvedilol and perindoprilat, while suitable as an adherence determining assay for enalaprilat. Equivalence between observed and predicted plasma concentrations proves DBS and plasma concentrations can be used interchangeably.

11.
J Mass Spectrom Adv Clin Lab ; 26: 48-59, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36532696

ABSTRACT

Background: Optimizing antimicrobial therapy to attain drug exposure that limits the emergence of resistance, effectively treats the infection, and reduces the risk of side effects is of a particular importance in critically ill patients, in whom normal functions are augmented or/and are infected with pathogens less sensitive to treatment. Achievement of these goals can be enhanced by therapeutic drug monitoring (TDM) for many antibiotics. A liquid chromatography tandem mass spectrometry (LC-MS/MS) method is presented here for simultaneous quantification of ten antimicrobials: cefazolin (CZO), cefepime (CEP), cefotaxime (CTA), ceftazidime (CTZ), ciprofloxacin (CIP), flucloxacillin (FLU), linezolid (LIN), meropenem (MER), piperacillin (PIP) and tazobactam (TAZ) in human plasma. Methods: Plasma samples were precipitated with acetonitrile and injected into the LC-MS/MS. Chromatographic separation was on a Waters Acquity BEH C18 column. Compounds were eluted with water and acetonitrile containing 0.1 % formic acid, using a gradient (0.5-65 % B), in 3.8 min. The flow rate was 0.4 mL/min, and the run time was 5.8 min. Results: The calibration curves were linear across the tested concentration ranges (0.5-250, CZO, CEP, CTA, CTZ and FLU; 0.2-100, MER and TAZ; 0.1-50, CIP and LIN and 1-500 mg/L, PIP). The intra and inter-day imprecision was < 11 %. Accuracy ranged from 95 to 114 %. CTZ and MER showed ionization suppression while CIP showed ionization enhancement, which was normalized with the use of the internal standard. Conclusion: An LC-MS/MS method for simultaneous quantification of ten antimicrobials in human plasma was developed for routine TDM.

12.
Bioanalysis ; 14(18): 1197-1211, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36331037

ABSTRACT

Aim: Mouse models have been crucial to preclinical studies in the increasingly relevant fields of cell and gene therapy. However, only small quantities of mouse blood can be collected without producing adverse physiological effects that compromise data integrity. Results: To address this limitation, two combined methods were developed to create detailed droplet digital PCR (ddPCR) and hematological profiles using only ∼20 µl of mouse blood. The validation of these methods, which can serve as a foundation for a standardized regulatory pipeline for ddPCR, is discussed. Even when using small amounts of input, this ddPCR protocol is accurate, precise, selective, specific, stable and robust. Conclusion: These techniques enable more frequent sample collection for higher-resolution pharmacokinetic data that meets or exceeds quality standards.


This article addresses new experimental methods that optimize two distinct techniques. The first technique, known as droplet digital PCR (ddPCR), is a process where DNA is isolated in oil droplets, cloned and then counted. The second technique is known as hematological profiling, in which various components of blood are counted (e.g., red blood cells, hemoglobin). Although ddPCR is incredibly promising as a research tool, there are a few hurdles that limit its usage. First, as of the time of writing, regulatory bodies (i.e., FDA and EMA) have not published official or standardized guidelines specific for either ddPCR or a closely related technique known quantitative PCR (qPCR). This has been an impetus for scientists to independently adopt and abide by unofficial recommendations for ddPCR and to negotiate with these regulatory bodies without a mutually accepted reference point between the two parties. Second, ddPCR can consume considerable volumes of blood, which can impair overall health; this limits how often samples can be taken, making scientists less effective at tracking how much medicine remains in the bloodstream over time. The new methods in this article use less blood, addressing these concerns and allowing scientists to safely collect blood from subjects more often, while also meeting all regulatory criteria established for similar scientific techniques and following informal and widely agreed upon scientific recommendations. Therefore, this work can serve as an easily adaptable framework for most ddPCR experiments.


Subject(s)
Real-Time Polymerase Chain Reaction , Animals , Mice , Real-Time Polymerase Chain Reaction/methods , Reference Standards
13.
J Mass Spectrom Adv Clin Lab ; 25: 44-52, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35910411

ABSTRACT

Introduction: Preoperative diagnostic workup of adrenal tumors is based on imaging and hormone analyses, but charged with uncertainties. Steroid profiling by liquid chromatography tandem mass spectrometry (LC-MS/MS) in 24-h urine has shown potential to discriminate benign and malignant adrenal tumors. Our aim was to develop and validate a specific and accurate LC-MS/MS method for the quantification of deconjugated urinary marker steroids, to evaluate their pre-analytical stability and to apply the method to clinical samples of patients with adrenal tumors. Methods: A method for the quantification of 11 deconjugated steroids (5-pregnenetriol, dehydroepiandrosterone, cortisone, cortisol, α-cortolone, tetrahydro-11-deoxycortisol, etiocholanolone, pregnenolone, pregnanetriol, pregnanediol, and 5-pregnenediol) in human urine was developed and validated based on international guidelines. Steroids were enzymatically deconjugated and extracted by solid phase extraction before LC-MS/MS quantification in positive electrospray ionization mode. Results: Excellent linearity with R2 > 0.99 and intra- and inter-day precisions of < 10.1 % were found. Relative matrix effects were between 96.4 % and 101.6 % and relative recovery was between 98.2 % and 115.0 %. Sufficient pre-freeze stability for all steroids in urine was found at 20-25 °C for seven days and at 4-6 °C for up to 28 days. Samples were stable during long-term storage at -20 °C and -80 °C for 6 months. Conclusions: A sensitive and robust LC-MS/MS method for the quantification of 11 urinary steroids was developed and validated according to international guidelines. Pre-analytical matrix stability was evaluated and the suitability of the method for the analysis of clinical samples and prospective validation studies was shown.

14.
J Mass Spectrom Adv Clin Lab ; 25: 27-35, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35721272

ABSTRACT

Introduction: Remdesivir (GS-5734) is a nucleoside analog prodrug with antiviral activity against several single-stranded RNA viruses, including the novel severe respiratory distress syndrome virus 2 (SARS-CoV-2). It is currently the only FDA-approved antiviral agent for the treatment of individuals with COVID-19 caused by SARS-CoV-2. However, remdesivir pharmacokinetics/pharmacodynamics (PK/PD) and toxicity data in humans are extremely limited. It is imperative that precise analytical methods for the quantification of remdesivir and its active metabolite, GS-441524, are developed for use in further studies. We report, herein, the first validated anti-viral paper spray-mass spectrometry (PS-MS/MS) assay for the quantification of remdesivir and GS-441524 in human plasma. We seek to highlight the utility of PS-MS/MS technology and automation advancements for its potential future use in clinical research and the clinical laboratory setting. Methods: Calibration curves for remdesivir and GS-441524 were created utilizing seven plasma-based calibrants of varying concentrations and two isotopic internal standards of set concentrations. Four plasma-based quality controls were prepared in a similar fashion to the calibrants and utilized for validation. No sample preparation was needed. Briefly, plasma samples were spotted on a paper substrate contained within pre-manufactured plastic cassette plates, and the spots were dried for 1 h. The samples were then analyzed directly for 1.2 min utilizing PS-MS/MS. All experiments were performed on a Thermo Scientific Altis triple quadrupole mass spectrometer utilizing automated technology. Results: The calibration ranges were 20 - 5000 and 100 - 25000 ng/mL for remdesivir and GS-441524, respectively. The calibration curves for the two antiviral agents showed excellent linearity (average R2 = 0.99-1.00). The inter- and intra-day precision (%CV) across validation runs at four QC levels for both analytes was less than 11.2% and accuracy (%bias) was within ± 15%. Plasma calibrant stability was assessed and degradation for the 4 °C and room temperature samples were seen beginning at Day 7. The plasma calibrants were stable at -20 °C. No interference, matrix effects, or carryover was discovered during the validation process. Conclusions: PS-MS/MS represents a useful methodology for rapidly quantifying remdesivir and GS-441524, which may be useful for clinical PK/PD, therapeutic drug monitoring (TDM), and toxicity assessment, particularly during the current COVID-19 pandemic and future viral outbreaks.

15.
J Mass Spectrom Adv Clin Lab ; 25: 19-26, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35734440

ABSTRACT

Introduction: The measurement of insulin and C-peptide provides a valuable tool for the clinical evaluation of hypoglycemia. In research, these biomarkers are used together to better understand hyperinsulinemia, hepatic insulin clearance, and beta cell function. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is an attractive approach for the analysis of insulin and C-peptide because the platform is specific, can avoid certain limitations of immunoassays, and can be multiplexed. Previously described LC-MS/MS methods for the simultaneous quantification of insulin and C-peptide measure the intact analytes and most have relied on immunoaffinity enrichment. These approaches can be limited in terms of sensitivity and interference from auto-antibodies, respectively. We have developed a novel method that does not require antibodies and uses proteolytic digestion to yield readily ionizable proteotypic peptides that enables the sensitive, specific, and simultaneous quantitation of insulin and C-peptide. Methods: Serum samples were precipitated with acetonitrile. Analytes were enriched using solid phase extraction and then digested with endoproteinase Glu-C. Surrogate peptides for insulin and C-peptide were analyzed using targeted LC-MS/MS. Results: Inter-day imprecision was below 20 %CV and linearity was observed down to the lower limit of quantitation for both analytes (insulin = 0.09 ng/mL, C-peptide = 0.06 ng/mL). Comparison to a commercially available insulin immunoassay (Beckman Coulter UniCel DxI 600 Access) revealed a 30% bias between methods. Conclusion: A novel LC-MS/MS method for the simultaneous analysis of insulin and C-peptide using Glu-C digestion was developed and evaluated. A detailed standard operating procedure is provided to help facilitate implementation in other laboratories.

16.
J Mass Spectrom Adv Clin Lab ; 24: 57-64, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35520954

ABSTRACT

Background: Utilising stable isotope labelled internal standards (SIL-IS) in quantitative LC-MS/MS drug analysis is the most widely used approach to normalise for variability during sample quantification processes. However, compounds containing atoms such as Sulphur, Chlorine or Bromine, could potentially cause cross-signal contribution to the SIL-IS from the naturally occurring isotopes, resulting in non-linear calibration curves. A simple, novel method of mitigating the effect is presented here. It entails monitoring of a less abundant SIL-IS isotope, as the precursor ion, of a mass that has no/minimal isotopic contribution from the analyte isotopes. Methods: Experiments were conducted on two LC-MS/MS analysers: Waters Xevo TQ-S and Shimadzu 8050. Flucloxacillin (FLX) was used as an example. Two transitions were selected for FLX (m/z 454 â†’ 160 â†’ 295) and one for each of the SIL-IS isotopes (m/z 458 â†’ 160 for the isotope 457 g/mol and m/z 460 â†’ 160 for the isotope 459 g/mol). Assay biases were assessed at three SIL-IS concentrations: 0.7, 7 and 14 mg/L for each isotope. Results: When using the SIL-IS isotope m/z 458 â†’ 160 at a concentration of 0.7 mg/L, biases were up to 36.9 % on both instruments. Increasing the SIL-IS concentration to 14 mg/L, reduced the bias to 5.8 %. Using the less abundant isotope, m/z 460 â†’ 160, resulted in biases of 13.9 % at an SIL-IS concentration of 0.7 mg/L. Conclusions: Applying this method will mitigate cross-signal contribution from the analyte isotopes to the corresponding SIL-IS, minimise the use of SIL-IS, and, thereby, reduce overall cost.

17.
J Mass Spectrom Adv Clin Lab ; 24: 100-106, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35602307

ABSTRACT

Introduction: Clobazam is a benzodiazepine drug, used to treat Lennox-Gastaut syndrome in patients aged 2 years and older. Objective: To support patient care, our laboratory developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantification of clobazam (CLB) and its major active metabolite N-desmethylclobazam (N-CLB) in human plasma or serum samples. Methods: The chromatographic separation was achieved with an Agilent Zorbax Eclipse Plus C-18 RRHD column with mobile phase consisting of 0.05% formic acid in 5 mM ammonium formate, pH 3.0 and 0.1% formic acid in acetonitrile at a flow rate of 600 µL/minute and an injection volume of 5 µL. The detection was performed on a triple quadrupole mass spectrometer in multiple reaction monitoring mode to monitor precursor-to-product ion transitions in positive electrospray ionization mode. Results: The method was validated over a concentration range of 20-2000 ng/mL for CLB and 200-10,000 ng/mL for N-CLB. The lower limit of quantification was 20 ng/mL for CLB and 200 ng/mL for N-CLB with good accuracy and precision. The method performance was successfully evaluated by comparison with two different external laboratories. Retrospective data analysis was performed to evaluate the positivity rate and metabolic patterns for clobazam from our patient population, as a reference laboratory. Among the positive samples, both parent and metabolite were detected in 96.4% of the samples. Conclusion: The method was developed to support therapeutic drug monitoring and the data generated from retrospective analysis could be useful for result interpretation in conjunction with clinical patient information.

18.
J Mass Spectrom Adv Clin Lab ; 25: 1-11, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35637738

ABSTRACT

Introduction: Amino acids are critical biomarkers for many inborn errors of metabolism, but amino acid analysis is challenging due to the range of chemical properties inherent in these small molecules. Techniques are available for amino acid analysis, but they can suffer from long run times, laborious derivatization, and/or poor resolution of isobaric compounds. Objective: To develop and validate a method for the quantitation of a non-derivatized free amino acid profile in both plasma and urine samples using mixed-mode chromatography and tandem mass spectrometry. Methods: Chromatographic conditions were optimized to separate leucine, isoleucine, and allo-isoleucine and maintain analytical runtime at less than 15 min. Sample preparation included a quick protein precipitation followed by LC-MS/MS analysis. Matrix effects, interferences, linearity, carryover, acceptable dilution limits, precision, accuracy, and stability were evaluated in both plasma and urine specimen types. Results: A total of 38 amino acids and related compounds were successfully quantitated with this method. In addition, argininosuccinic acid was qualitatively analyzed. A full clinical validation was performed that included method comparison to a reference laboratory for plasma and urine with Deming regression slopes ranging from 0.38 to 1.26. Conclusion: This method represents an alternative to derivatization-based methods, especially in urine samples where interference from metabolites and medications is prevalent.

19.
Mol Genet Metab Rep ; 30: 100843, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35242574

ABSTRACT

GM2 and GM1 gangliosidoses are genetic, neurodegenerative lysosomal sphingolipid storage disorders. The earlier the age of onset, the more severe the clinical presentation and progression, with infantile, juvenile and late-onset presentations broadly delineated into separate phenotypic subtypes. Gene and substrate reduction therapies, both of which act directly on sphingolipidosis are entering clinical trials for treatment of these disorders. Simple to use biomarkers for disease monitoring are urgently required to support and expedite these clinical trials. Here, lysosphingolipid and protein biomarkers of sphingolipidosis and neuropathology respectively, were assessed in plasma samples from 33 GM2 gangliosidosis patients, 13 GM1 gangliosidosis patients, and compared to 66 controls. LysoGM2 and lysoGM1 were detectable in 31/33 GM2 gangliosidosis and 12/13 GM1 gangliosidosis patient samples respectively, but not in any controls. Levels of the axonal damage marker Neurofilament light (NF-L) were highly elevated in both GM2 and GM1 gangliosidosis patient plasma samples, with no overlap with controls. Levels of the astrocytosis biomarker Glial fibrillary acidic protein (GFAP) were also elevated in samples from both patient populations, albeit with some overlap with controls. In GM2 gangliosidosis patient plasma NF-L, Tau, GFAP and lysoGM2 were all most highly elevated in infantile onset patients, indicating a relationship to severity and phenotype. Plasma NF-L and liver lysoGM2 were also elevated in a GM2 gangliosidosis mouse model, and were lowered by treatment with a drug that slowed disease progression. These results indicate that lysosphingolipids and NF-L/GFAP have potential to monitor pharmacodynamics and pathogenic processes respectively in GM2 and GM1 gangliosidoses patients.

20.
J Mass Spectrom Adv Clin Lab ; 23: 44-49, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35028636

ABSTRACT

INTRODUCTION: We have developed a set of tools built with open-source software that includes both a database and a visualization component to collect LC-MS/MS data and monitor quality control parameters. DESCRIPTION OF TOOL: To display LC-MS/MS data we built a parsing tool using Python and standard libraries to parse the XML files after each clinical run. The tool parses the necessary information to store a database comprised of three distinct tables. Another component to this toolkit is an interactive data visualization tool that uses the data from the database. There are 5 different visualizations that present the data based on interchangeable parameters. EVALUATION OF TOOL: Using histogram visualization, we assessed how quality control parameters that feed our quality control algorithm, SMACK, which assists to improve the efficiency of data review and results, performed against the collective data. Using the newly identified QC parameter values from the toolkit, we compared the output of the SMACK algorithm; the number of QC flags changed in that there was a 1.7% (31/1944 observations) increase in flags and a 7.1% (138/1944 observations) decrease in presumed false positive flags, increasing the overall performance of SMACK which helped staff focus their time on reviewing more concerning QC failures. DISCUSSION: We have developed a customizable web-based dashboard for instrument performance monitoring for our opiate confirmation LC-MS/MS assay using data collected with each batch. The web-based platform allows users to monitor instrument performance and can encompass other instruments throughout the laboratory. This information can help the laboratory take proactive measures to maintain instruments, ultimately reducing the amount down time needed for maintenance.

SELECTION OF CITATIONS
SEARCH DETAIL