Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 599
Filter
1.
Heliyon ; 10(13): e34172, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39071601

ABSTRACT

Statement of the problem: Patient stratifications considered the stability of color and treatment longevity are key success of restoration. Daily consumption of colored beverages, such as coffee, tea, and soft drinks, as well as the use of globally consumed materials, such as smokeless tobacco (ST), snuff, Khat, and Yerba mate, can change the color of restorative materials, such as lithium disilicate glass ceramics (LDGC). These changes can ultimately lead to treatment failure. Purpose: This in vitro study aimed to evaluate color changes, translucency, and opalescence of full anatomical LDGC crowns exposed to commonly used and potentially colorant solutions. Materials and methods: Ninety LDGC specimens/crowns were prepared and divided into nine groups according to immersion solution (control, Saudi Coffee, Cola, Khat, Yerba mate, Nescafe, ST Snuff, and Mixed Fruit Juice). The specimens were immersed in colorant solutions for 15 days with alternating twice daily at 37 °C. Color parameters were measured with a spectrophotometer and calculated using two backgrounds (black and white). Data were subjected to ANOVA followed by the Student t-test and Bonferroni test at a significant difference level (α = 0.05). Results: The greatest color change (ΔE*) among groups after immersion was observed in Yerba mate (7.6 ± 1.6). The mean difference of before and after staining within Yerba mate group was 3.14 ± 1.6 (p = 0.001). Translucency mean values of groups after immersion into staining media were ranging between 7.6 ± 1.2 and 9.1 ± 2, showing a slight decrease compared with pre-staining values but was not significantly different. Immersion in Mixed Fruit Juice significantly reduced opalescence (7.4 ± 1.9) compared to (8.8 ± 1.7) before staining. Conclusion: The findings confirm that appropriate user guidance helps to preserve both translucency and opalescence as well as prevent color changes. This can improve patient compliance and promote treatment longevity.

2.
J Funct Biomater ; 15(7)2024 Jun 22.
Article in English | MEDLINE | ID: mdl-39057293

ABSTRACT

Fracture resistance is an important parameter used to predict the performance of indirect dental restorations. The purpose of this in vitro study was to assess the fracture load of posterior milled nanoceramic crowns, in comparison with the lithium disilicate crowns, after fatigue loading, for two different restoration occlusal thicknesses. Forty test metal dies were fabricated by duplicating a master metal model consisting of an anatomic abutment preparation of the maxillary first premolar for a single crown. The dies were divided into two groups of 20 each for the fabrication of nanoceramic (Lava Ultimate) and lithium disilicate (IPS e.max CAD) single crowns. Each material group was further divided into two sub-groups of 10 dies each, based on crown occlusal thickness, of 0.5-mm and 0.75-mm (n = 10). Dental Type V stone dies poured from polyvinyl siloxane impressions of the test metal dies were laboratory scanned in order to design and mill 40 ceramic crowns. The crowns were cemented on to the test metal dies with a self-adhesive resin luting cement. All crowns were thermocycled (2500 cycles) and mechanically loaded (250,000 cycles) in a chewing simulator followed by static loading until failure, and the values noted. The data were statistically analyzed by 2-way ANOVA and Tukey HSD post-hoc multiple comparison tests (α = 0.05). The mean fracture loads ranged from 1022 to 1322 N for nanoceramic crowns and from 1145 to 1441 N for the lithium disilicate crowns. Two-way ANOVA revealed insignificant differences between the nanoceramic and lithium disilicate crowns (p > 0.05) in terms of fracture load. Significant differences were noted in the fracture resistance of crowns based on occlusal thickness (303 N; p = 0.013) regardless of the material used. Multiple comparisons by Tukey HSD post-hoc test showed insignificant differences between the four material-occlusal thickness groups (p > 0.05). The nanoceramic crowns were found to be comparable with lithium disilicate crowns in terms of fracture load. The mean fracture loads of all of the tested crowns were within the normal physiological masticatory load limits. Based on the fracture-resistance results, nanoceramic crowns seem to be suitable for clinical use for the tested occlusal thicknesses.

3.
Rev Cient Odontol (Lima) ; 12(1): e182, 2024.
Article in Spanish | MEDLINE | ID: mdl-39015314

ABSTRACT

Introduction: In oral rehabilitation, the use of ceramic restorations is widely accepted due to its aesthetic capacity to mimic the naturalness of the dental tissue, provide longevity of the material, and present a greater marginal fit compared to crowns with a metal structure. Termination lines are biological preparations whose function is to minimize the cervical opening of the marginal seal. Consequently, analyzing the behavior of restorative materials under compressive forces decreases the risk of fracture and increases the success of the treatment. Objective: To compare the compressive stresses of lithium disilicate crowns with three different finishing lines. Methodology: In silico study of the simulation of a dental preparation on a lower right first molar with chamfer (0.6 mm), shoulder (0.5 mm) and deep chamfer (0.5 mm) finish lines. Using the SolidWorks®ï¸ version 2017 software, the maximum stresses, minimum stresses, and location of the compressive force were collected on the Megapascal (Mpa) measurement scale. Results: The chamfer type termination line (0.6mm) obtained a lower compressive stress compared to the other two shoulder type termination lines (0.5mm) and deep chamfer (0.5mm). Conclusions: It was shown that the chamfer type finishing line (0.6mm) presented a better force distribution, determining greater reliability in the selection of this finishing line with the use of a lithium disilicate crown in a unitary manner.

4.
J Dent ; 148: 105257, 2024 Jul 21.
Article in English | MEDLINE | ID: mdl-39043330

ABSTRACT

OBJECTIVE: Evaluate the impact of a "fast" crystallization and simultaneous-glazing on the physicochemical properties of lithium-disilicate CAD/CAM-ceramic. METHODS: Lithium-disilicate bars and crowns (IPS e.max CAD, Ivoclar-Vivadent) were divided into four groups (n = 30): WG/F (WG=with glaze/F=fast crystallization), NG/F (NG=no glaze), WG/C (C=conventional crystallization), and NG/C. A liquid/powder glaze system was used (IPS Ivocolor®, Ivoclar-Vivadent). Specimens were crystallized (Programat P310, Ivoclar-Vivadent) using the P161 program for C (approx. 20-25 min), and P165 for F (approx. 14-16 min). Bars (n = 30) underwent three-point bending tests (flexural strength-FS in MPa and modulus of elasticity-E in GPa) using a universal testing machine. Crowns were analyzed via scanning electron microscopy (SEM) after selective etching, and to Raman, FTIR-ATR, and X-ray diffraction (XRD) spectroscopies to assess chemical composition. RESULTS: For FS, both factors/interaction were statistically significant. C (427.48±42.41 MPa) showed significantly higher values than F (409.82±38.82 MPa). WG (398.32±29.80 MPa) exhibited significantly lower FS than NG (438.21±41.77 MPa). For E data, both factors/interaction were significant. NG (90.28±14.71 GPa) displayed higher E than WG (83.07±5.69 GPa), while C (90.08±12.98 GPa) exhibited higher E than F (83.46±9.40 GPa). NG/C showed the best results for both variables. F groups showed (SEM) porous surfaces and crack-like marks on crystals. FTIR, Raman and XRD spectra confirmed the typical composition of a lithium-disilicate glass ceramic, and some attenuated signals and structural variations (XRD) in WG. CONCLUSIONS: "Fast" crystallization and simultaneous-glazing produced weaker/less-rigid structures with irregular crystals and glassy phases. Simultaneous glazing may have hindered proper thermal distribution during crystallization. SIGNIFICANCE: "Fast" crystallization and simultaneous glazing with non-recommended systems, can adversely affect the final properties of lithium disilicate restorations.

5.
Acta Stomatol Croat ; 58(2): 123-135, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39036328

ABSTRACT

Objectives: The aim of this randomized controlled trial was to see if the minimally invasive approach (reduced restoration thickness) would result in good clinical success of monolithic ceramic crowns compared to conventional layered all-ceramic crowns, and thus be an alternative to conventional tooth preparation. Materials and methods: The ceramic that was investigated was IPS e.max lithium-disilicate ceramic produced using two different processing methods. A comparison was made between monolithic crowns with reduced thickness and standard layered crowns. Fifty-two patients, who had undergone endodontic treatment on either a premolar or molar, were randomly assigned into two groups. The teeth intended for layered crowns underwent to a 2 mm occlusal reduction with a 1 mm rounded shoulder, whereas the teeth intended for monolithic crowns underwent to a 1 mm reduction in the occlusal area with a 0.6 mm rounded shoulder. The clinical success was evaluated in eight categories using modified United States Public Health Service (USPHS) criteria. The observation period was 36 months, with control appointments every 6 months. Results: There was no significant difference in clinical success between monolithic and conventional layered crowns after 3 years. One monolithic crown fractured while all other crowns were intact and the survival rate was 96%. All layered crowns were intact and the survival rate was 100%. Conclusion: The results of this study indicate that the minimally invasive approach can be a good alternative to conventional tooth preparation. IPS e.max lithium-disilicate ceramic demonstrated an exceptional three-year survival rate independently of the thickness of the material.

6.
Article in English | MEDLINE | ID: mdl-38881646

ABSTRACT

Background: Insufficient information exists regarding the fracture resistance and failure pattern of newly developed zirconia-reinforced lithium disilicate (ZL, Vita Ambria) onlays. This in vitro study compared the fracture resistance of two types of onlays: monolithic lithium disilicate (LD) and monolithic ZL. Methods: Forty-eight ceramic onlay restorations were fabricated on epoxy dies using a maxillary first premolar model. The samples were divided into two main groups: LD and ZL. Half of each group was subjected to thermomechanical fatigue loading (TML) using a chewing simulator. All the samples were cemented with self-adhesive resin cement. Subsequently, they were loaded until failure in a universal testing machine, and the fracture patterns and resistance were recorded. Results: Before TML, ZL demonstrated the highest statistically significant mean fracture resistance (499.76±34.14N) compared to LD (470.40±27.38N). After TML, ZL showed the highest non-statistically significant mean fracture resistance (429.27±131.42N), while LD's mean fracture resistance decreased (377.31±62.18N). Conclusion: Monolithic zirconia-reinforced onlays demonstrated higher fracture resistance and a more favorable failure mode compared to LD. However, the impact of thermomechanical aging resulted in reduced fracture resistance for both materials, with a notable preference observed for ZL.

7.
Polymers (Basel) ; 16(11)2024 May 29.
Article in English | MEDLINE | ID: mdl-38891480

ABSTRACT

BACKGROUND: Sealing the peri-implant tissue is a determining factor for long-term implant survival. In the transmucosal region, the cervical fraction of the prosthetic crown is in contact with these tissues, so mucointegration will also be influenced by the biomaterial used for the prosthetic restoration. This study aims to compare the tissue response generated by definitive restorative materials and polymeric materials from a histological point of view. METHODS: This study performed an observational prospective cohort study in which biopsies of the peri-implant mucosa were taken after placement of implant-supported prosthetic restorations made of different materials (zirconium oxide, lithium disilicate, and PMMA). RESULTS: A statistically significant difference was observed in the increase in the thickness of the non-keratinized epithelium when comparing the definitive materials (zirconium oxide/lithium disilicate) vs. the provisional material (PMMA) and in the number of collagen fibers when comparing zirconium oxide and lithium disilicate. CONCLUSIONS: This study found that zirconia is the material that presents the most adequate biological response of peri-implant tissues. It shows a lower intensity of inflammatory cellular content, a total normality in the number of collagen fibers (the arrangement of the fibers is normal in 90% of the cases), and vascular proliferation of connective tissue in 83% of the cases. These parameters make it a material with a predictable response. Similarly, only the following slight statistically significant differences between the definitive and provisional materials are observed, indicating that the biological response generated by the provisional material (PMMA) is not very different from that obtained with the placement of the definitive restoration.

8.
BMC Oral Health ; 24(1): 660, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38840111

ABSTRACT

BACKGROUND: Effects of ceramic translucency, layer thickness, and substrate colour on the shade of lithium disilicate glass-ceramic restorations proved to be significant in several studies, however, quantitative, numerical results on the relationship between the colour difference and these parameters are still lacking. The purpose of this in vitro study was to quantitatively determine how the colour reproduction ability of a lithium disilicate glass-ceramic is affected by its translucency, layer thickness, and substrate colour. METHODS: Ceramic samples were prepared from A2 shade IPS e.max CAD blocks with high and low translucencies (HT and LT) in a thickness range of 0.5-2.5 mm (+/- 0.05 mm). Layered samples were acquired utilizing composite substrates in 9 shades; transparent try-in paste was used. The spectral reflectance of the specimens was assessed under D65 standard illumination with a Konica Minolta CM-3720d spectrophotometer. The CIEDE2000 colour difference (ΔE00) between two samples was analysed using perceptibility and acceptability thresholds set at 50:50%. Statistical analysis involved linear regression analysis and the Kruskal-Wallis test. RESULTS: An increase in the thickness of 0.5 mm reduced the ΔE00 of the HT samples to 72.8%, and that of the T samples to 71.1% (p < 0.0001). 7 substrates with HT and LT specimens had significantly different results from the mean (p < 0.05). A thickness of 0.5 mm is not sufficient to achieve an acceptable result at any level of translucency, while the low translucency ceramic at a thickness of 1.5 mm gave acceptable results, except for severely discoloured substrates (ND8 and ND9). CONCLUSIONS: The colour reproduction ability of lithium disilicate glass-ceramics is significantly affected by their translucency, layer thickness, and 7 substrates out of 9 substrates examined.


Subject(s)
Ceramics , Color , Dental Porcelain , Dental Porcelain/chemistry , Ceramics/chemistry , Prosthesis Coloring , Spectrophotometry , Materials Testing , Humans , Surface Properties
9.
J Prosthodont Res ; 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38925985

ABSTRACT

PURPOSE: Fixed restorations and dental enamel have different structures that produce different wear on opposing teeth, resulting in clinical problems. Therefore, it is necessary to determine the type of restoration that causes less wear on naturally opposing teeth to make recommendations. The objective of this study was to systematically analyze the evidence from observational studies and clinical trials on enamel wear in different ceramic restorations. STUDY SELECTION: The designs of the included studies were randomized clinical trials (RTCs), non-randomized clinical trials (non-RTCs), and observational studies (OS). The studies must answer the research question, be available in full text, be written in English or Spanish, and have had at least six months of follow-up. Protocol number: CRD42023397759. RESULTS: After screening 499 records, 20 RTCs were subjected to data extraction, 10 were excluded, 10 were included in the systematic review, and only 5 were included in the network meta-analysis. The risk of bias assessment reported moderate to high risk of bias, quality, and certainty of evidence was evaluated and rated as moderate. Network meta-analysis showed higher enamel wear was observed in natural dental enamel against metal-ceramic antagonists. CONCLUSIONS: Enamel wear occurs in all teeth, even when the antagonist is a natural tooth. The wear is larger on surfaces with the ceramic crown antagonists studied (metal-ceramic, glazed zirconia, and polished zirconia). It is necessary to conduct additional clinical trials with larger follow-up periods and sample sizes.

10.
Clin Oral Investig ; 28(7): 370, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38869624

ABSTRACT

OBJECTIVES: To investigate the effect of multiple firings on color, translucency, and biaxial flexure strength of Virgilite-containing (Li0.5Al0.5Si2.5O6) lithium disilicate glass ceramics of varying thickness. MATERIALS AND METHODS: Sixty discs were prepared from Virgilite-containing lithium disilicate blocks. Discs were divided according to thickness (n = 30) into T0.5 (0.5 mm) and T1.0 (1.0 mm). Each thickness was divided according to the number of firing cycles (n = 10); F1 (Control group): 1 firing cycle; F3: 3 firing cycles, and F5: 5 firing cycles. The discs were tested for color change (ΔE00) and translucency (TP00) using a spectrophotometer. Then, all samples were subjected to biaxial flexure strength testing using a universal testing machine. Data were collected and statistically analyzed (α = 0.5). For chemical analysis, six additional T0.5 discs (2 for each firing cycle) were prepared; for each firing cycle one disc was subjected to X-ray diffraction analysis (XRD) and another disc was subjected to Energy dispersive X-ray spectroscopy (EDX) and Scanning electron microscope (SEM). RESULTS: Repeated firing significantly reduced the translucency of F3 and F5 compared to F1 in T0.5 (p < 0.001), while for T1.0 only F5 showed a significant decrease in TP00 (p < 0.001). For ΔE00, a significant increase was recorded with repeated firings (p < 0.05) while a significant decrease resulted in the biaxial flexure strength regardless of thickness. CONCLUSIONS: Repeated firings had a negative effect on both the optical and mechanical properties of the Virgilite-containing lithium disilicate glass ceramics. CLINICAL RELEVANCE: Repeated firings should be avoided with Virgilite-containing lithium disilicate ceramics to decrease fracture liability and preserve restoration esthetics.


Subject(s)
Ceramics , Dental Porcelain , Flexural Strength , Materials Testing , Surface Properties , X-Ray Diffraction , Ceramics/chemistry , Dental Porcelain/chemistry , Color , Dental Stress Analysis , Spectrophotometry , Microscopy, Electron, Scanning , Hot Temperature
11.
Dent Mater J ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38825449

ABSTRACT

The surface treatment of glass-ceramic-based materials, namely, lithium disilicate glass (IPS e.max CAD), feldspar porcelain (VITABLOCS Mark II), and a polymer-infiltrated ceramic network (VITA ENAMIC), using aqueous fluoride solutions and their influence on luting agent bonding were investigated. Six experimental aqueous fluoride solutions were applied to these materials, and their effects were assessed by surface topological analysis. The obtained results were compared using non-parametric statistical analyses. Ammonium hydrogen fluoride (AHF) etchant demonstrated the greatest etching effect. Subsequent experiments focused on evaluating different concentrations of the AHF etchant for the bonding pretreatment of glass-ceramic-based materials with a luting agent (PANAVIA V5). AHF, particularly at concentrations above 5 wt%, effectively roughened the surfaces of the materials and improved the bonding performance. Notably, AHF at a concentration of 30 wt% exhibited a more pronounced effect on both etching and bonding capabilities compared to hydrofluoric acid.

12.
Materials (Basel) ; 17(9)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38730851

ABSTRACT

AIM: This in vitro study aimed to compare the light-transmission properties of two chairside CAD/CAM lithium disilicate (LD) ceramics (a novel fully crystallized and a traditional pre-crystallized) across varying thicknesses. MATERIALS AND METHODS: One hundred flat specimens were obtained from precrystallized (e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and fully crystallized (LiSi GC Block; GC, Tokyo, Japan) LD at five different thicknesses (0.5, 0.75, 1.0, 1.50 and 2.0 mm). All specimens were polished with a polishing system for lithium disilicate restorations following recommendations from the manufacturer. Light transmission was evaluated with a radiometer. The statistical analysis between e.max CAD and LiSi GC Block was performed using a Mann-Whitney test for each thickness at a significance level of 0.05 (p < 0.05), followed by a Kruskal-Wallis test to compare the light transmission between the thicknesses of e.max CAD and LiSi GC Block. RESULTS: Light transmittance was significantly affected by ceramic thickness. The 0.5 mm thick specimens exhibited the highest transmittance values compared to all other groups, while a light transmittance of 0.00 was observed in the 2.0 mm thick specimens for both e.max CAD and LiSi GC Block. In the comparison between e.max CAD and LiSi GC Block according to thickness, there was a statistically significant difference exclusively between groups with a thickness of 1.50 mm (p = 0.002). CONCLUSIONS: Light transmission for pre- and fully crystallized CAD/CAM lithium disilicate ceramics only showed a statistical difference at the thickness of 1.50 mm (p = 0.002). E.max CAD demonstrated acceptable light transmission up to a thickness of 1.5 mm. CLINICAL SIGNIFICANCE: A thickness of 2 mm for chairside CAD/CAM lithium disilicate ceramics, whether pre-crystallized or fully crystallized, necessitates the use of dual-cure resin luting cement due to reduced light transmission.

13.
Cureus ; 16(4): e57384, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38694648

ABSTRACT

This case report presents an overview of the workflow and advantages of computer-aided design and manufacture (CAD/CAM) technology in designing single crowns for anterior restoration. The workflow of CAD/CAM systems involves extraoral scanning, virtual crown design, and automated milling processes. The advantages of CAD/CAM technology include enhanced accuracy, reduced chairside time, and improved patient satisfaction. Considerations for material selection, clinical indications, and associated factors in CAD/CAM single-crown design are also discussed. Additionally, CAD/CAM provided accurate and lifelike restoration contours, ensuring optimal fit, function, and aesthetics. This technology proved highly beneficial in this case for several reasons. This case illustrates the significant advantages of CAD/CAM technology in modern dental practice, offering precise, efficient, and aesthetically pleasing solutions for single dental crowns.

14.
J Prosthodont ; 2024 May 06.
Article in English | MEDLINE | ID: mdl-38706398

ABSTRACT

PURPOSE: This study evaluated the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate crown, onlay, and non-anatomical occlusal veneer (A-OV) with and without margin fabricated. MATERIALS AND METHODS: Sixty-four CAD-CAM lithium disilicate restorations were designed as (1) complete coverage crown (CCC); (2) A-OV with margin; (3) non-A-OV with margin (NA-OV-M); and (4) non-A-OV without margin (NA-OV-NM), 16 of each. Restorations were crystallized and adhesively luted to resin dies using resin cement. Specimens were then subjected to 400,000 cycles of chewing in a mastication simulator. A universal testing machine was used to apply a compressive load at a crosshead speed of 1 mm/min to the long axis of the tooth with a stainless-steel sphere until fracture occurred. One-way ANOVA followed by post hoc tests were used to assess the impact of preparation design on the fracture load of CAD-CAM lithium disilicate restorations. RESULTS: The highest fracture load was recorded for CAD-CAM lithium disilicate indirect restorations for non-A-OVs preparation with margin (2549 ± 428 N) and onlay (2549 ± 293 N) and the lowest fracture load was recorded for CCCs (2389 ± 428 N); however, there was no significant (p = 0.640) between groups. CONCLUSIONS: CAD-CAM lithium disilicate restorations fabricated for anatomical and non-A-OV preparation display a fracture resistance similar to CCCs. Conservative partial coverage restorations may be considered an acceptable approach for posterior teeth.

15.
J Prosthodont ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715352

ABSTRACT

PURPOSE: To evaluate the fracture load of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) veneers fabricated with two conventional pre-crystallized and two fully crystallized lithium disilicate ceramic materials. MATERIALS AND METHODS: Seventy-five chairside CAD-CAM veneers (15 specimens/group) for maxillary right central incisors were fabricated with different lithium disilicate brands: (1) IPS e.max CAD; (2) Amber Mill; (3) Cerec Tessera; (4) n!ce Straumann; and (5) GC Initial LiSi Block. Restorations were cemented with resin luting cement (Variolink Esthetic, Ivoclar) to 3D-printed resin dies. Bonded restorations received 5000 thermal cycles and then were loaded until fracture. Statistical analysis included One-Way ANOVA. RESULTS: Conventional pre-crystallized e.max CAD displayed the highest fracture load value (640 N), followed by fully-crystallized n!ce Straumann (547 N), pre-crystallized Cerec Tessera (503 N), pre-crystallized Amber Mill (476 N), respectively; fully-crystallized GC Initial LiSi Block (431 N) displayed the lowest values. When comparing the fracture load of recent lithium disilicate ceramic material to the e.max group, which acted as the control, significant differences were noted. The LiSi Block GC group, in particular, had considerably higher mean difference values (208.867, p < 0.001, 95% CI [89.63, 328.10]), as did the Amber Mill group (164.200, p = 0.002, 95% CI [44.96, 283.44]) and CEREC Tessera group (137.533, p = 0.016, 95% CI [18.30, 256.77]). The e.max and n!ce Straumann groups had no statistically significant differences in mean scores (92.933, p = 0.198, 95% CI [-26.30, 212.17]). These findings imply that the clinical performance of recent lithium disilicate veneers varies when compared to the e.max CAD group. CONCLUSIONS: The fracture load of chairside CAD-CAM lithium disilicate veneers for maxillary central incisors varies according to the type of ceramic brands. Conventional pre-crystallized e.max CAD displayed higher fracture load than the recent pre- and fully-crystallized lithium disilicate materials, emphasizing the significance of choosing the right product based on the desired clinical outcome.

16.
J Dent ; 146: 105053, 2024 07.
Article in English | MEDLINE | ID: mdl-38729288

ABSTRACT

OBJECTIVES: To give a comprehensive review of advancement in dental ceramics, fabrication methods, and the challenges associated with clinical application. DATA, SOURCES AND STUDY SELECTION: Researches on chemical composition, biomechanical behaviors, optical properties, bonding strategies and fabrication methods were included. The search of articles was independently conducted by two authors in the PubMed, Scopus, Medline and Web of Science. CONCLUSIONS: Dental ceramics have shown significant advancements in terms of esthetics and function. However, improving fracture toughness without compromising optical properties remains a challenge. Repairing fractured zirconia or glass-matrix ceramic prostheses with the same material is difficult due to the sintering process. Developing innovative bonding techniques that provide strong and long-lasting bonding strength between ceramics and tooth structures poses a recurring obstacle. CLINICAL SIGNIFICANCE: Despite the emergence of dental ceramics and fabrication techniques, certain limitations such as susceptibility to brittleness and fracture still exist. Therefore, the current review provided valuable information around the advanced dental ceramics in tooth repair. The laboratory test data and the clinical outcome are also presented in details, aiming to guide clinicians in making informed decisions regarding ceramic restorations.


Subject(s)
Ceramics , Zirconium , Humans , Ceramics/chemistry , Zirconium/chemistry , Dental Materials/chemistry , Dental Bonding/methods , Dental Porcelain/chemistry , Esthetics, Dental , Materials Testing , Dental Prosthesis Design
17.
J Dent ; 146: 105067, 2024 07.
Article in English | MEDLINE | ID: mdl-38763385

ABSTRACT

OBJECTIVES: The aim of this study is to compare the aesthetic outcomes of metal porcelain (C), lithium disilicate (T1) and porcelain-layered zirconium (T2) immediate implant-supported single crowns in the anterior maxilla. MATERIALS AND METHODS: Forty-five immediate dental implants were provided for 45 patients that required the extraction of a single tooth in the anterior maxilla. A temporary prosthesis was provided at 8 weeks after placement followed by the final prosthesis at 24 weeks post-implantation. The patients were randomly allocated into 3 groups: 15 patients in the control group (C) received a metal-porcelain restoration, 15 patients (T1) received a lithium disilicate (LD) restoration and 15 patients (T2) received a porcelain-layered, zirconium (Z) restoration. Pink (PES) and White (WES) esthetic scores, radiographic bone levels, periodontal parameters and patient's esthetic satisfaction using a visual analogue scale (VAS) were evaluated at the time of final restoration placement (t0) and at 12-months post-loading (t12). RESULTS: No implants were lost during the duration of this study. Statistically significant higher WES and VAS scores (p < 0.05) were recorded in T1 vs C and T1 vs T2 groups respectively. Similar radiographic bone levels and periodontal parameters were recorded in all groups. CONCLUSION: Within the limitations of this study, it was concluded that T1 restorations provided better WES outcomes when compared to C restorations and better VAS scores when compared to T2 restorations at 12 months post-loading. Besides, different material interphases did not have an impact in PES, bone levels or periodontal parameters. CLINICAL RELEVANCE: There is limited data comparing aesthetic outcomes of implant supported single crowns made of different ceramic materials based on accepted and comparable indexes and the evaluation of the patient's perspective regarding these aesthetic outcomes.


Subject(s)
Crowns , Dental Implants, Single-Tooth , Dental Porcelain , Dental Prosthesis, Implant-Supported , Esthetics, Dental , Immediate Dental Implant Loading , Zirconium , Humans , Female , Male , Zirconium/chemistry , Dental Porcelain/chemistry , Adult , Middle Aged , Treatment Outcome , Patient Satisfaction , Dental Materials/chemistry , Maxilla/surgery , Metal Ceramic Alloys/chemistry , Dental Prosthesis Design , Young Adult
18.
Contemp Clin Dent ; 15(1): 44-50, 2024.
Article in English | MEDLINE | ID: mdl-38707666

ABSTRACT

Background: Computer-aided design/computer-aided manufacturing (CAD/CAM) resin ceramics allow easier milling than glass ceramics but are suspected to be more stainable. Although Photoshop® is widely used for picture analysis, its potential for shade selection has not been properly assessed. Aim: Purpose primary: To evaluate the color stability of three CAD/CAM resin ceramics and Lithium Disilicate. Secondary: to compare the color evaluation between a spectrophotometer (Vita Easyshade compact) and Photoshop software. Materials and Methods: Three CAD/CAM resin ceramic materials (n = 10) and a fourth group of lithium disilicate were used. Half of each group were thermocycled (5°C and 55°C; 3000 cycles). All samples were immersed in colored beverages (coffee, tea and red wine) for 30 days. Values were obtained by spectrophotometry and photographs analyzed using Photoshop software. The parameters measured were CIEL*a*b, and the color difference (ΔE) was analyzed. A mixed model test was used to compare the results through time and materials (α = 0.05). The comparison between the spectrophotometer and Photoshop results was performed using the bivariate Pearson's correlation test. Results: Lithium disilicate glass ceramic exhibited less color change (ΔE = 14) than resin ceramics (15.7 < ΔE < 18.7). The least change was noted with GC Cerasmart (ΔE = 15.7) followed by Vita Enamic (ΔE = 17*) and Brilliant Crios (ΔE = 18.7*). Spectrophotometer and Photoshop values showed low correlations. Conclusions: Resin ceramics may suffer from color change in clinical use. Photoshop is technique sensitive; pictures are easily affected by the light conditions and camera settings.

19.
BMC Oral Health ; 24(1): 457, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622649

ABSTRACT

BACKGROUND: Self-glazed zirconia (SZ) restorations are made by a novel additive three-dimensional gel deposition approach, which are suitable for a straightforward completely digital workflow. SZ has recently been used as minimally invasive veneer, but its clinical outcomes have not been clarified yet. This study aimed to evaluate the preliminary clinical outcomes of SZ veneers compared with the widely used lithium disilicate glass-ceramic veneers made by either pressing (PG) or milling (MG) process. METHODS: Fifty-six patients treated with SZ, PG, and MG veneers by 2 specialists between June 2018 and October 2022 were identified. Patients were recalled for follow-up at least 1 year after restoration. Clinical outcomes were assessed by 2 independent evaluators according to the modified United States Public Health Service (USPHS) criteria. Overall patient satisfaction was assessed using visual analogue scale (VAS), and analyzed by one-way ANOVA. Chi-square test was applied to compare the difference in the success and survival rates among the 3 groups. RESULTS: A total of 51 patients restored with 45 SZ, 40 PG, and 41 MG veneers completed the study, with a patient dropout rate of 8.9%. Mean and standard deviation of follow-up period was 35.0 ± 14.7 months. All restorations performed well at baseline, except for 2 SZ veneers with mismatched color (rated Bravo). During follow-up, marginal discrepancy (rated Bravo) was found in 4 MG veneers and 1 PG veneer, and partially fractured (rated Charlie) was found in another 2 PG veneers. The survival rate of SZ, PG, and MG veneers was 100%, 95%, and 100%, with a success rate of 95.56%, 92.50%, and 90.24%, respectively, none of which were significantly different (p = 0.099 and 0.628, respectively). The mean VAS score of SZ, PG, and MG was 95.00 ± 1.57, 93.93 ± 2.40, and 94.89 ± 2.00 respectively, without significant difference (p > 0.05). CONCLUSION: SZ veneers exhibited comparable preliminary clinical outcomes to PG and MG veneers, which could be considered as a feasible option for minimally invasive restorative treatment.


Subject(s)
Dental Restoration Failure , Dental Veneers , Nitriles , Zirconium , Humans , Retrospective Studies , Ceramics , Materials Testing , Computer-Aided Design
20.
BMC Oral Health ; 24(1): 472, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38641578

ABSTRACT

PURPOSE: The aim of the current study was to evaluate the effect of simulated gastric acid on the color and translucency of different indirect restorative materials. MATERIALS AND METHODS: A total of 36 disc-shaped samples were cut by using an isomet saw and divided into four equal groups (n = 9) according to the material type: Group Z: translucent zirconia (Ceramill® Zolid ht.+ preshade, Amann Girrbach, Koblach, Austria); Group E: lithium disilicate (IPS e.max CAD, Ivoclar Vivadent AG, Schaan, Liechtenstein); Group C: resin nanoceramic (Cerasmart, GC, Tokyo, Japan); Group P: polyether ether ketone (PEEK) (Bettin Zirconia Dentale Italy) veneered with indirect high impact polymer composite (HIPC) (breCAM HIPC, Bredent GmbH & Co. KG, Germany). The samples were immersed in simulated gastric acid (HCl, pH 1.2) for 96 hours at 37 °C in an incubator. The color change (ΔE00) and translucency (RTP00) were measured every 9.6 hours (one-year clinical simulation) of immersion in simulated gastric acid. RESULTS: For color change (∆E00) and translucency (RTP00) among the tested materials, there was a highly statistically significant difference (P < 0.001) after every year of follow-up. The color change in both Z and G groups was the lowest after 1 year of acid immersion, followed by that in group H, and the highest change in color was recorded in group P. CONCLUSION: High translucent zirconia is recommended in patients who are concerned about esthetic, especially with acidic oral environment.


Subject(s)
Ceramics , Dental Materials , Humans , Materials Testing , Zirconium , Surface Properties , Color , Computer-Aided Design
SELECTION OF CITATIONS
SEARCH DETAIL