Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 442
Filter
1.
BMC Ophthalmol ; 24(1): 410, 2024 Sep 19.
Article in English | MEDLINE | ID: mdl-39300358

ABSTRACT

PURPOSE: To compare the biometric measurements obtained from the Pentacam AXL Wave, IOLMaster 700, and ANTERION and calculate the recommended intraocular lens power using the Barrett Formulae. METHODS: This was a retrospective cross-sectional study of patients who underwent biometry using the Pentacam AXL Wave, IOLMaster 700, and ANTERION. Flat keratometry (K1), steep keratometry (K2), anterior chamber depth (ACD), and axial length (AL) from each device were measured and compared. These parameters were used to calculate the recommended IOL powers using the Barrett formula. RESULTS: The study included 252 eyes of 153 patients. The IOLMaster had the highest acquisition rate among the two biometers. The Pentacam obtained the shortest mean AL, the IOLMaster measured the highest mean keratometry values, and the ANTERION measured the highest mean ACD. In terms of pairwise comparisons, keratometry and axial length were not significantly different between the Pentacam-IOLMaster and ANTERION-IOLMaster groups, while the rest of the pairwise comparisons were statistically significant. In nontoric and toric eyes, 35-45% of patients recommended the same sphere of IOL power. In another 30-40%, the Pentacam and ANTERION recommended an IOL power one step greater than that of the IOLMaster-derived data. 50% of the study population recommended the same toric-cylinder IOL power. CONCLUSIONS: The Pentacam AXL Wave, IOLMaster 700, and ANTERION can reliably provide data for IOL power calculations; however, these data are not interchangeable. In nontoric and toric eyes, 35-45% of cases recommended the same sphere IOL power, and in another 30-40%, the Pentacam and ANTERION recommended one-step higher IOL power than the IOLMaster-derived data. In targeting emmetropia, selecting the first plus IOL power is advisable when using the Pentacam and ANTERION to approximate the IOL power calculations recommended by the IOLMaster 700.


Subject(s)
Biometry , Interferometry , Lenses, Intraocular , Tomography, Optical Coherence , Humans , Retrospective Studies , Cross-Sectional Studies , Male , Biometry/instrumentation , Biometry/methods , Female , Middle Aged , Interferometry/instrumentation , Interferometry/methods , Aged , Tomography, Optical Coherence/methods , Tomography, Optical Coherence/instrumentation , Axial Length, Eye/diagnostic imaging , Adult , Aged, 80 and over , Refraction, Ocular/physiology , Optics and Photonics , Anterior Chamber/diagnostic imaging
2.
J Fr Ophtalmol ; 47(7): 104080, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39218721

ABSTRACT

PURPOSE: This study aimed to compare the differences between the Zeiss IOL Master and Oculus Pentacam in keratometry and central anterior chamber depth (ACD) measurements in patients with high myopia and cataracts. METHODS: Between January 2019 and December 2020, 89 patients (103 eyes) with cataracts and high myopia who underwent preoperative cataract evaluation at Nanchang First Hospital were selected for retrospective analysis. Keratometry (K1, K2) and ACD were measured with the IOL Master and Pentacam. Paired t-tests were performed to compare the differences, while the Bland-Altman method was used to evaluate the agreement. RESULTS: The K1 value was (43.15±2.44) D for the IOL Master and (42.98±2.47) D for the Pentacam, and the difference between the two instruments was statistically significant (P<0.01). The K2 value was (44.55±2.63) D for the IOL Master and (44.32±2.55) D for the Pentacam. The ACD was (3.44±0.33)mm for the IOL Master and (3.39±0.36)mm for the Pentacam. There were statistically significant differences between the two instruments in both keratometry and ACD (P<0.01). The absolute values of the maximum difference between the two instruments for K1 and K2 were 1.1 and 1.07; thus, the consistency of the two instruments with respect to this measurement was poor. However, the absolute value of the maximum difference between the two instruments for ACD was 0.34, so the consistency of the two instruments in relation to this measurement was good. CONCLUSIONS: Both the IOL Master and the Pentacam can be used in the measurement of keratometry and ACD in patients with high myopia and cataracts, but the keratometry measurements should be compared in clinical application.


Subject(s)
Cataract , Myopia , Humans , Cataract/diagnosis , Cataract/pathology , Male , Female , Retrospective Studies , Middle Aged , Aged , Myopia/diagnosis , Myopia/pathology , Adult , Anterior Eye Segment/diagnostic imaging , Anterior Eye Segment/pathology , Anterior Chamber/pathology , Anterior Chamber/diagnostic imaging , Cataract Extraction , Aged, 80 and over
3.
Expert Rev Med Devices ; : 1-6, 2024 Sep 04.
Article in English | MEDLINE | ID: mdl-39233346

ABSTRACT

OBJECTIVES: To investigate the diagnostic value of iTrace visual function analyzer, Pentacam 3D anterior segment analysis system and Lens Opacities Classification System III (LOCS III) in assessing lens opacity in patients with age-related cataract (ARC). METHODS: A total of 129 patients with ARC admitted to Anonymized from May 2019 to April 2021 were selected as the research objects. The degree of lens opacity was evaluated by LOCS III classification, iTrace and anterior segment analysis. RESULTS: The Pentacam nucleus staging (PNS) grade was strongly correlated with nuclear color (NC) (r = 0.537, p < 0.05) and moderately correlated with nuclear opalescence (NO) (r = 0.473, p < 0.05). The integrated density (IntDen) in 3-mm nuclear region was strongly correlated with NC (r = 0.548, p < 0.05) and NO (r = 0.539, p < 0.05). The dysfunctional lens index (DLI) in 3-mm area was negatively correlated with NC (r=-0.252, p < 0.05), NO (r=-0.239, p < 0.05) and posterior subcapsular cataract (r=-0.271, p < 0.05). PNS was weakly negatively correlated with the DLI in 3-mm area (r=-0.219, p < 0.05), and IntDen in 3-mm core area was weakly negatively correlated with the DLI in 3-mm area (r=-0.291, p < 0.05). CONCLUSION: A combination of iTrace, anterior segment analysis and LOCS III may be beneficial in objectively assessing the opacity of different regions of the lens.

4.
Eur J Ophthalmol ; : 11206721241281876, 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39223843

ABSTRACT

BACKGROUND AND OBJECTIVES: To assess the agreement between Anterion AS-OCT and three optical devices in measuring the white-to-white (WTW) diameter in candidates for refractive surgery. METHODS: In this cross-sectional prospective study, 129 right eyes of 129 normal individuals underwent consecutive scans with the Anterion, the Pentacam AXL, the IOLMaster 700, and the Orbscan IIz. Mean difference (MD), 95% limits of agreement (LoA), and concordance correlation coefficient (CCC) were calculated to assess agreement and interchangeability. RESULTS: The mean age of participants was 30.4 ± 5.9 (range: 21-47) years. The mean WTW distance measured by the different instruments was as follows: 12.00 ± 0.42 mm (range, 10.57 to 13.05) using the Anterion, 11.87 ± 0.34 (11.10 to 12.80) using the Pentacam, 12.12 ± 0.44 (11.00 to 13.30) using the IOLMaster, and 11.73 ± 0.37 (11.00 to 13.10) using the Orbscan. The MD and 95% LoA for Anterion vs. Pentacam, IOLMaster, or Orbscan were [0.11; -0.31 to 0.54 mm], [-0.13; -0.93 to 0.66], and [0.25; -0.28 to 0.78], respectively. The corresponding CCCs were 0.803, 0.514, and 0.631. CONCLUSIONS: This study found weak agreement between Anterion and Pentacam AXL, IOLMaster 700, and Orbscan IIz devices regarding WTW distance measurements in refractive surgery candidates. Therefore, it is not recommended to use Anterion's WTW measurements interchangeably with the other three devices, particularly for phakic intraocular lens sizing.

5.
Photodiagnosis Photodyn Ther ; 49: 104302, 2024 Aug 10.
Article in English | MEDLINE | ID: mdl-39134252

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the correlations and consistency among the central corneal thickness (CCT) of healthy myopic patients measured with three different anterior segment analysis systems. DESIGN: This was a retrospective study. The study included myopia patients who had undergone preoperative examinations in the refractive surgery department of our hospital between January 2021 and December 2023. The CCT was measured separately using Pentacam, Sirius, and IOLMaster 700. METHODS: Statistical analysis was conducted using SPSS software. Correlations among the three groups of measured values were assessed using the Pearson method, and a simple scatter plot and fitting line were drawn. Bland‒Altman scatter plots and 95 % limits of agreement (LoAs) were used to evaluate consistency in the data among the systems. RESULTS: A total of 269 patients participated in the study, including 134 males (49.8 %) and 135 females (50.2 %). The CCT measurements by Pentacam, Sirius, and IOLMaster 700 instruments were found to be 541.63 ± 31.67 µm, 541.74 ± 33.36 µm, and 548.90 ± 34.19 µm respectively; significant differences were observed among these measurements (p < 0.05). Significant differences were also observed in CCT between Pentacam and IOLMaster 700 as well as between Sirius and IOLMaster 700 (p < 0.05). The CCT measurements by all three devices showed high positive correlation with all p values less than 0.001: Pentacam and Sirius, r = 0.972; Pentacam and IOLMaster 700, r = 0.966; and Sirius and IOLMaster 700, r = 0.962. The respective 95 % LoAs were -0.18∼0.18; -1.51∼-1.11; and -1.52∼-1. CONCLUSION: The results indicate that there is a high correlation in measuring CCT for healthy myopic eyes using three different anterior segment analysis systems. However, the differences in the values measured by the three devices were statistically significant. Therefore, in actual clinical practice, it is suggested that the same device should be used to measure and evaluate the CCT across visits.

6.
BMC Ophthalmol ; 24(1): 349, 2024 Aug 16.
Article in English | MEDLINE | ID: mdl-39152392

ABSTRACT

BACKGROUND: Accurate prediction of postoperative vault in implantable collamer lens (ICL) implantation is crucial; however, current formulas often fail to account for individual anatomical variations, leading to suboptimal visual outcomes and necessitating improved predictive models. We aimed to verify the prediction accuracy of our new predictive model for vaulting based on anterior and posterior chamber structural parameters. METHODS: This retrospective observational study included 137 patients (240 eyes) who previously underwent ICL surgery. Patients were randomly divided into the model establishment (192 eyes) or validation (48 eyes) groups. Preoperative measurements of the anterior and posterior chamber structures were obtained using Pentacam, CASIA2 anterior segment optical coherence tomography (AS-OCT), ultrasound biomicroscopy, and other devices. Stepwise multiple linear regression analysis was used to evaluate the relationship between the vault and each variable (WL formula). The Friedman test was performed for the vaulting prediction results of the WL, NK (Ver. 3), and KS formulas (Ver. 4) in CASIA2 AS-OCT, as well as the Zhu formula and vault measurements. The proportions of prediction error within ± 250 µm per formula were compared. RESULTS: The predicted vault values of the WL, NK, KS, and Zhu formulas and vault measurements were 668.74 ± 162.12, 650.85 ± 248.47, 546.56 ± 128.99, 486.56 ± 210.76, and 716.06 ± 233.84 µm, respectively, with a significant difference (χ2 = 69.883, P = 0.000). Significant differences were also found between the measured vault value and Zhu formula, measured vault value and KS formula, WL formula and Zhu formula, WL formula and KS formula, NK formula and KS formula, and NK formula and Zhu formula (P < 0.001) but not between other groups. The proportions of prediction error within ± 250 µm per formula were as follows: WL formula (81.3%) > NK formula (70.8%) > KS formula (66.7%) > Zhu formula (54.2%). CONCLUSIONS: The WL formula, which considers the complexity of the anterior and posterior chamber structures, demonstrates greater calculation accuracy, compared with the KS (Ver. 4) and Zhu formulas. The proportion of absolute prediction error ≤ 250 µm is higher with the WL formula than with the NK formula (ver. 3). This enhanced predictive capability can improve ICL sizing decisions, thereby increasing the safety and efficacy of ICL implantation surgeries.


Subject(s)
Lens Implantation, Intraocular , Tomography, Optical Coherence , Humans , Retrospective Studies , Female , Male , Tomography, Optical Coherence/methods , Adult , Lens Implantation, Intraocular/methods , Anterior Chamber/diagnostic imaging , Phakic Intraocular Lenses , Myopia/surgery , Microscopy, Acoustic/methods , Young Adult , Middle Aged , Visual Acuity , Biometry/methods , Refraction, Ocular/physiology
7.
Clin Ophthalmol ; 18: 2303-2311, 2024.
Article in English | MEDLINE | ID: mdl-39185362

ABSTRACT

Purpose: To determine if Scheimpflug tomography pachymetry map and posterior elevation map patterns can predict the occurrence of corneal edema following uneventful phacoemulsification surgery in Fuchs endothelial corneal dystrophy (FECD). Design: Observational prospective case-control study. Participants: Fifty FECD eyes (50 patients) with visually significant cataract: 25 with subclinical corneal edema (SCE) versus 25 without SCE. Methods: Preoperatively, FECD was clinically assessed, and only patients devoid of clinical corneal edema were enrolled. Utilizing the Mayo Clinic classification for subclinical corneal edema (SCE), eligible FECD eyes were stratified based on Scheimpflug imaging pachymetry map and posterior elevation map characteristics, including loss of regular isopachs, displacement of the cornea's thinnest point, and the presence of posterior surface depression, into two groups: Group A representing FECD with SCE, and Group B: FECD without SCE. One week postoperatively, clinical and tomographic evaluation was performed. Regression analysis was conducted to evaluate predictors of corneal edema after uneventful phacoemulsification surgery in both groups. Results: All patients were successfully imaged before and 1 week after surgery. Visual acuity was significantly improved in both groups (P < 0.001). No postoperative clinical edema was observed in Group B, while 23 (92%) had mild edema and 2 (8%) had moderate edema in Group A. Both groups showed a significant increase in postoperative central corneal thickness (CCT) and thinnest corneal thickness (TCT) (both P < 0.001). Compared to Group B, Group A showed a significant central flattening of the anterior corneal surface (P = 0.007 and P = 0.04 for K1 and K2 respectively), and a significant increase in the postoperative posterior surface depression. Multivariate analysis showed that 94% of postoperative corneal edema could be predicted by the presence of preoperative posterior surface depression (P = 0.04, ARR = 5.8 (1.89-35.7)). Conclusion: Scheimpflug tomography pachymetry map and posterior elevation map patterns can predict corneal edema after uneventful phacoemulsification surgery in FECD with subclinical corneal edema.

8.
Article in English | MEDLINE | ID: mdl-39206080

ABSTRACT

Background: The effects of trabeculectomy on anterior segment parameters have been widely investigated. However, the stabilization time for various glaucoma types after trabeculectomy remains debatable. We investigated the effect of mitomycin C-augmented trabeculectomy on ocular anterior segment parameters in primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PXG) during short-term follow-up using the Pentacam HR. Methods: In this retrospective observational study, consecutive patients diagnosed with medically uncontrolled POAG or PXG who underwent MMC-augmented trabeculectomy were recruited. All individuals underwent detailed ocular examinations. All trabeculectomies were performed by a single surgeon using the same technique. Anterior segment parameters, including anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), and central corneal thickness (CCT) were measured using the Pentacam HR, along with intraocular pressure (IOP) using a Goldmann applanation tonometer, pre-operatively and at 1-week, 1-month, and 3-month post-operative visits. Results: We included 80 patients with a median (range) age of 58.0 (41.0-86.0) years having a nearly similar sex ratio. The study groups were matched according to sex and age (both P > 0.05). The group-by-time interaction was significant for CCT and ACV (both P < 0.05) but not for IOP, ACD, and ACA (all P > 0.05). The mean (standard deviation [SD]) IOP, ACD, and ACA were comparable between groups (all P > 0.05) during the 3-month period; however, they changed significantly over time in both groups (all P < 0.001). The mean CCT and ACV were comparable between groups at each time point (all P > 0.05), except at the 1-month post-operative visit, at which the mean (SD) ACV was significantly lower in the PXG group (P < 0.05). We found a comparable mean (SD) CCT between paired visits in each group (all P > 0.05), except for the mean (SD) CCT at 3 months, which was significantly lower than that at the 1-month post-operative visit in the PXG group (P < 0.05). We found a comparable mean (SD) ACV between paired visits in each group (all P > 0.05); however, it was significantly lower at the 1-month post-operative versus the baseline visit in both groups and resumed a significantly higher value at the 1-month versus the 1-week visit and at the 3-month versus the 1-month visit in the PXG group (all P < 0.05). Conclusions: We observed significant changes in IOP, ACD, and ACA over 3 months after post-augmented trabeculectomy in eyes with POAG and PXG; however, the majority of anterior segment parameters were comparable between the two groups. Further large-scale studies with longer follow-up periods should be conducted to verify the post-operative fluctuations in these parameters in POAG and PXG.

9.
J Ophthalmic Vis Res ; 19(2): 144-151, 2024.
Article in English | MEDLINE | ID: mdl-39055507

ABSTRACT

Purpose: To investigate the effect of the near visual task of movie-watching in the straight gaze position on corneal topographic parameters. Methods: Thirty myopic young adults with an average age of 25.10 ± 4.13 years were recruited for the study. The designed near visual task consisted of watching a movie in the straight gaze position at a distance of 40 cm for 30 minutes. Corneal topography was performed using Oculus Keratograph 4 (OCULUS, Wetzlar, Germany) before and immediately after watching the movie, as well as at 10, 20, and 30 minutes intervals after completing this near visual task. Zernike coefficients, asphericity indices, refractive parameters, and diagnostic indices of keratoconus were recorded for statistical analysis. Results: Movie-watching at a close distance solely using the straight gaze position had no effect on Zernike coefficients (P > 0.130). Also, watching the movie had no effect on other corneal topography parameters including irregularities (P = 0.208), spherical eccentricity (P = 0.270), maximum decentration (P = 0.553), axis of maximum decentration (P = 0.186), peripheral astigmatism (P = 0.179), and average asphericity of the quadrants at 10 to 30º (P > 0.163). Conclusion: The results of the present study showed that watching movies in the straight gaze position had no effect on corneal topographic parameters and did not cause errors in corneal topographic measurements.

10.
BMC Ophthalmol ; 24(1): 285, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39009964

ABSTRACT

AIM: This study aimed to differentiate moderate to high myopic astigmatism from forme fruste keratoconus using Pentacam parameters and develop a predictive model for early keratoconus detection. METHODS: We retrospectively analysed 196 eyes from 105 patients and compared Pentacam variables between myopic astigmatism (156 eyes) and forme fruste keratoconus (40 eyes) groups. Receiver operating characteristic curve analysis was used to determine the optimal cut-off values, and a logistic regression model was used to refine the diagnostic accuracy. RESULTS: Statistically significant differences were observed in most Pentacam variables between the groups (p < 0.05). Parameters such as the Index of Surface Variance (ISV), Keratoconus Index (KI), Belin/Ambrosio Deviation Display (BAD_D) and Back Elevation of the Thinnest Corneal Locale (B.Ele.Th) demonstrated promising discriminatory abilities, with BAD_D exhibiting the highest Area under the Curve. The logistic regression model achieved high sensitivity (92.5%), specificity (96.8%), accuracy (95.9%), and positive predictive value (88.1%). CONCLUSION: The simultaneous evaluation of BAD_D, ISV, B.Ele.Th, and KI aids in identifying forme fruste keratoconus cases. Optimal cut-off points demonstrate acceptable sensitivity and specificity, emphasizing their clinical utility pending further refinement and validation across diverse demographics.


Subject(s)
Corneal Topography , Keratoconus , Photography , ROC Curve , Humans , Keratoconus/diagnosis , Female , Male , Retrospective Studies , Adult , Ghana , Corneal Topography/methods , Photography/methods , Young Adult , Adolescent , Cornea/pathology , Cornea/diagnostic imaging , Middle Aged , Myopia/diagnosis , Astigmatism/diagnosis , Visual Acuity
11.
Saudi J Ophthalmol ; 38(2): 152-156, 2024.
Article in English | MEDLINE | ID: mdl-38988782

ABSTRACT

PURPOSE: The purpose of the study is to establish normative values of eye parameters such as lens thickness (LT), lens diameter (LD), and axial length (AXL) among wide age range of Saudis using Pentacam AXL and compare these values between gender, in addition to that, to find the correlation between the age and those parameters. METHODS: In this prospective cross-sectional study, we measured LT, LD, and AXL in 125 healthy Saudi controls aged between 8 and 60 years using OCULUS Pentacam AXL. The screening tests were performed for each subject to exclude any ocular abnormalities using slit lamp (Haag-Streit BQ 900), refractive error measured using auto refractometer (Topcon KR-1 Autorefractor/Keratometer), and subject who has spherical equivalent more than ± 4.00D and astigmatism more than 1.00DC was excluded from the study. The mean of three readings of LT, LD, and AXL was taken. All examination was applied on one eye (right eye). RESULTS: The overall mean and standard deviation of LT, LD, and AXL was 2.2 mm ± 0.5, 2.7 mm ± 0.6, and 23.8 mm ± 1.0, respectively. There was no statistically significant difference between males and females in these parameters in all age groups, except in Group 2 (age: 19-30 years), there was a statistically significant difference between males and females in AXL, mean difference (M = 0.48), and P = 0.015. The mean of LT and LD was negatively associated with age. However, there was no significant correlation between AXL and age. CONCLUSION: Normative values of LT, LD, and AXL have been established in wide age group of healthy Saudis; the findings of the present study can highlight not only the normal range of the different ocular parameters, namely LT, LD, and AXL, but also their variation with age and gender.

12.
Diagnostics (Basel) ; 14(13)2024 Jul 08.
Article in English | MEDLINE | ID: mdl-39001345

ABSTRACT

PURPOSE: This article introduces the Pentacam® Cornea OCT (optical coherence tomography). This advanced corneal imaging system combines rotating ultra-high-resolution spectral domain OCT with sub- 2-micron axial resolution and Scheimpflug photography. The purpose of this study is to present the first experience with the instrument and its potential for corneal diagnostics, including optical biopsy. METHODS: In this prospective study, the Pentacam® Cornea OCT was used to image the corneas of seven patients. The novel wide-angle pericentric scan system enables optimal OCT imaging performance for the corneal layer structure over the entire width of the cornea, including the limbal regions. A detailed analysis of the resulting images assessed the synergism between the OCT and Scheimpflug photography. RESULTS: The Pentacam® Cornea OCT demonstrated significantly improved image resolution and ability to individualize corneal layers with high quality. There is a synergism between the OCT high-definition signal to individualize details on the cornea and Scheimpflug photography to detect and quantify corneal scattering. The noncontact exam was proven safe, user-friendly, and effective for enabling optical biopsy. CONCLUSIONS: Pentacam® Cornea OCT is an advancement in corneal imaging technology. The ultra-high-resolution spectral domain OCT and Scheimpflug photography provide unprecedented detail and resolution, enabling optical biopsy and improving the understanding of corneal pathology. Further studies are necessary to compare and analyze the tomographic reconstructions of the cornea with the different wavelengths, which may provide helpful information for diagnosing and managing corneal diseases.

13.
Cureus ; 16(6): e61993, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38983996

ABSTRACT

Objective The objective of this study was to compare K1, K2, Kmax, and pachymetry values from Pentacam and Galilei scans of corneal topography in order to assess their correlation and interchangeability in clinical practice. Methodology A total of 34 patients (68 eyes) were enrolled in the study. Corneal topography was performed using Pentacam and Galilei devices on the same day. K1, K2, Kmax, and pachymetry readings were obtained from the scans and analyzed using paired t-tests and Bland-Altman plots. Results There were minimal differences in clinical settings between Pentacam and Galilei for K1, K2, Kmax (>0.75 D), and pachymetry values (>15 um). However, there was a statistically significant difference found between Kmax and pachymetry, making their interchangeability questionable. Conclusion Pentacam and Galilei demonstrate a good correlation between corneal keratometric values (K1, K2, and Kmax) and pachymetry values in clinical settings, and they should be used interchangeably with caution.

14.
Cesk Slov Oftalmol ; 80(3): 170-174, 2024.
Article in English | MEDLINE | ID: mdl-38886109

ABSTRACT

The aim of the thesis is to present the case of a patient in whom bilateral calcification of the hydrophilic intraocular lens (IOL) Lentis M+ LS-313 MF30 (Oculentis) has developed. Due to the negative effect on visual functions, explantation and replacement of the artificial lens was necessary in both eyes. Case Report: An overview of the available literature summarized the diagnostics, current examination methods and possibilities of the surgical solution of calcification of the bifocal hydrophilic lens Lentis M+ LS-313 MF30 (Oculentis). The specific solution is described in a case report of a patient in whom calcification of both lenses developed 6 years after implantation of the IOL. In 2015, the patient underwent uncomplicated cataract surgery of both eyes with the implantation of an artificial intraocular lens into the capsule. In September 2021, an 82-year-old man was examined at our outpatient clinic for deterioration of visual acuity and changes in the material of the artificial IOL which were perceptible during a clinical examination, on the recommendation of a local ophthalmologist. Blurred vision predominated. A diagnosis of intraocular lens opacification was confirmed and documented using a Scheimpflug camera (OCULUS Pentacam HR) and anterior OCT (Avanti RTVue XR Optovue,). The patient was indicated for explantation and replacement of the opacified intraocular lens in the left and subsequently in the right eye- The same type of IOL was used for reimplantation with good functional results. Conclusion: Since 2010, multifocal lens implantation has been on an upward trend worldwide. This type of MF IOL has also been used in thousands of implantations. A number of other explantations can be expected in the coming years. The optimal solution is the correct replacement of the calcified IOL with the same construction made of safer hydrophobic material.


Subject(s)
Melanoma , Radiosurgery , Humans , Male , Radiosurgery/adverse effects , Melanoma/radiotherapy , Aged, 80 and over , Calcinosis/surgery , Calcinosis/diagnostic imaging , Choroid Neoplasms/radiotherapy , Choroid Neoplasms/diagnosis , Lenses, Intraocular/adverse effects , Radiation Injuries/etiology , Radiation Injuries/diagnosis , Radiation Injuries/surgery , Uveal Neoplasms/radiotherapy , Lens Implantation, Intraocular/adverse effects
15.
Sci Rep ; 14(1): 13878, 2024 06 16.
Article in English | MEDLINE | ID: mdl-38880805

ABSTRACT

This study aimed to compare the differences and characteristics of white-to-white (WTW) values obtained before V4c implantation using triple person-times caliper, IOL-Master 700, Pentacam HR, and UBM, and to assess their correlation with vaulting. A total of 930 myopia patients (1842 eyes) who were interested in undergoing ICL surgery were assessed before the procedure using various instruments. The WTW measurements were obtained using a triple person-times caliper, Pentacam HR, and IOL-Master 700, whereas the angle-to-angle (ATA) measurements were obtained using UBM. The size of the ICL was subsequently calculated using triple person-times caliper measurements. The vault of the ICL was assessed using Pentacam HR three months after the surgery. The WTW was determined to be 11.30 ± 0.29 mm, 11.43 ± 0.29 mm, and11.86 ± 0.38 mm, respectively, using the triple person-times caliper, Pentacam HR, and IOL-Master 700. The measurement of ATA was 11.57 ± 0.51 mm, as done by UBM. The ICL vault was measured to be 400.97 ± 198.46 µm when examined with Pentacam HR three monthsafter the procedure. The linear regression analyses of ICL size and WTW of triple person-times caliper, ICL vault and WTW were (R = 0.703, p < 0.001; R = 0.0969, p < 0.001) respectively. The highest correlation was found between IOL-Master and Pentacam HR (r = 0.766, p = 0.000). The lowest correlation was found between UBM and Pentacam HR (r = 0.358, p = 0.002). Bland-Altman analysis showed that the 95% limits of agreement (LoA) were the triple person-times caliper and Pentacam HR (- 0.573, 0.298) and the triple person-times caliper and UBM (- 1.15, - 0.605). This indicated a strong agreement between the triple person-times caliper and Pentacam HR and a lack of agreement between the triple person-times caliper and UBM. Triple person-times caliper measurements offer excellent maneuverability, practicality, and reliable outcomes for determining ICL vaults. Measurements obtained using the triple-person caliper were less differece than those obtained using the Pentacam HR.


Subject(s)
Lens Implantation, Intraocular , Myopia , Humans , Male , Female , Adult , Myopia/surgery , Phakic Intraocular Lenses , Young Adult , Middle Aged , Adolescent
16.
Int Ophthalmol ; 44(1): 237, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38902457

ABSTRACT

PURPOSE: Calculating the intraocular lens (IOL) in patients after corneal refractive surgery presents a challenge. Because an overestimation of corneal power in cases undergone this surgery leading to a subsequent under-correction of IOL power. However, recent advancements in technology have eliable measurement of total corneal power. The aim of this research was to assess the agreement in simulated keratometry (SimK) and total keratometry (TK) values between IOLMaster 700 and Pentacam AXL. METHODS: The study involved 99 patients (99 eyes) undergone small incision lenticule extraction (SMILE) surgery. Each patient underwent scans using IOL Master 700 and Pentacam AXL. The following parameters were recorded: SimK1, SimK2, Total K1 (TK1), and Total K2 (TK2) for IOLMaster 700; and SimK1, SimK2, True Net Power (TNP) K1, TNPK2, Total Corneal Refractive Power (TCRP) K1, and TCRP K2 for Pentacam AXL. Agreement between the two devices was evaluated using Bland-Altman plot, while paired t-test was utilized to compare any differences in the same parameter by both instruments. RESULTS: The results revealed a strong correlation between the two devices.Noticeable comparability was identified for all SimK variables. However, there were noticeable differences in TK measurements as well as TK1-TNPK1, TK2-TNP K2, TK1-TCRP K1, and TK2-TCRP K2 parameters when comparing the two devices. The IOLMaster 700 consistently measured steeper values than the Pentacam AXL, with significant and clinically relevant differences of 1.34, 1.37, 0.87, and 0.95 diopters, respectively. CONCLUSION: While there was a noticeable correlation between the IOLMaster 700 and Pentacam AXL in SimK measurements, a marked difference was noted in TK values. The two devices cannot be used interchangeably when quantifying TK values.


Subject(s)
Cornea , Corneal Topography , Myopia , Refraction, Ocular , Humans , Male , Female , Adult , Cornea/surgery , Cornea/diagnostic imaging , Cornea/pathology , Refraction, Ocular/physiology , Corneal Topography/methods , Myopia/surgery , Myopia/diagnosis , Middle Aged , Young Adult , Lenses, Intraocular , Biometry/methods , Biometry/instrumentation , Prospective Studies , Reproducibility of Results , Visual Acuity , Corneal Surgery, Laser/methods
17.
Vestn Oftalmol ; 140(2. Vyp. 2): 136-142, 2024.
Article in Russian | MEDLINE | ID: mdl-38739143

ABSTRACT

Pterygium is a common inflammatory-proliferative disease characterized by the invasion of degeneratively altered fibrovascular tissue into the cornea. This literature review analyzes the etiological factors and pathogenetic concepts of its development, describes modern methods of diagnostics and surgical treatment of pterygium, and pays particular attention to the assessment of structural and functional changes in the cornea occurring during the growth of pterygium and after its excision.


Subject(s)
Ophthalmologic Surgical Procedures , Pterygium , Pterygium/diagnosis , Pterygium/therapy , Pterygium/etiology , Humans , Ophthalmologic Surgical Procedures/methods , Cornea/diagnostic imaging , Cornea/pathology , Conjunctiva/pathology
18.
Clin Ophthalmol ; 18: 1235-1243, 2024.
Article in English | MEDLINE | ID: mdl-38737594

ABSTRACT

Purpose: Diabetes mellitus (DM) causes different corneal changes that are associated with the severity of diabetic retinopathy. To identify the pathophysiological reasons for this, corneal tomography and optical densitometry (COD) were combined with retinal oximetry. Methods: Patients with DM and healthy subjects were included in this pilot study. Spatially resolved corneal thickness and COD were assessed using the Pentacam HR (Oculus). The pachymetry difference (PACDiff) was calculated as an indicator of an increase in the peripheral corneal thickness. Oxygen saturation (SO2) of the retinal vessels was measured using the Retinal Vessel Analyzer (Imedos Systems UG). Subsequently, the associations between corneal and retinal parameters were analyzed. Results: Data from 30 patients with DM were compared with those from 30 age-matched healthy subjects. In DM, arterial (P = 0.048) and venous (P < 0.001) SO2 levels were increased, and arteriovenous SO2 difference was decreased (P < 0.001). In patients, PACDiff was higher than that in healthy subjects (P < 0.05), indicating a stronger increase in peripheral corneal thickness. The COD was reduced in DM (P = 0.004). The PACDiff of concentric rings with a diameter of 4 mm (r = -0.404; P = 0.033) to 8 mm (r = -0.522; P = 0.004) was inversely correlated with the arteriovenous SO2 difference. Furthermore, PACDiff 4 mm was negatively associated with arterial SO2 (r = -0.389; P = 0.041), and the COD of the peripheral corneal areas correlated positive with arterial SO2 (COD total 10-12 mm: r = 0.408; P = 0.025). Conclusion: These associations might indicate a common pathogenesis of corneal and retinal changes in DM, which could be caused by reduced oxygen supply, mitochondrial dysfunction, oxidative stress, and cytokine effects.


Retinal changes are particularly important for ophthalmologists in the management of diabetes mellitus. These are primarily consequences of diabetic vascular changes that can lead to a lack of oxygen. However, there is also evidence of significant changes in the cornea of patients with diabetes. In the present study, the associations between changes in corneal thickness profile, optical density of the cornea, and oxygen saturation of retinal vessels in diabetes mellitus were demonstrated for the first time. Therefore, this study could contribute to clarifying the possible causes of corneal changes in patients with diabetes.

19.
Cureus ; 16(4): e58223, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38745798

ABSTRACT

INTRODUCTION: Evaluation of anterior segment parameters is crucial in ophthalmic procedures such as intraocular surgeries and contact lens fitting. However, the use of tropicamide in diabetic patients presents challenges due to its potential impact on biometric measurements. This study aims to investigate and compare the effects of 0.5% and 1% tropicamide on anterior segment parameters in diabetic patients. METHODS: This double-masked randomized clinical trial enrolled 98 patients with diabetes mellitus. Participants were randomly assigned to receive either 0.5% or 1% tropicamide. Anterior segment parameters were measured using Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) before and 30 minutes after tropicamide administration. Parameters included anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), keratometry, central corneal thickness (CCT), white-to-white distance (WTW), and pupillary diameter (PD). RESULTS: Both concentrations of 0.5% and 1% tropicamide induced significant changes in anterior segment parameters. There was a notable increase in PD (2.99 ± 0.62, 3.11 ± 0.55, respectively, both P-values < 0.001), ACD (both 0.10 ± 0.05, both P-values < 0.001), ACV (16.69 ± 9.56, 17.51 ± 9.26, respectively, both P-values < 0.001), and WTW (0.06 ± 0.14, 0.03 ± 0.30, respectively, both P-values < 0.001), along with a decrease in ACA (-3.50 ± 10.65, -3.30 ± 6.87, P-value < 0.001 and P-value=0.001, respectively), and CCT (-6.10 ± 8.06, -6.39 ± 9.97, respectively, both P-values < 0.001) post-dilation. However, no significant changes were observed in keratometry (front Km (-0.03 ± 0.19, -0.04 ± 0.21, respectively), back Km (0.01 ± 0.05, 0.004 ± 0.05, respectively), P-values> 0.05). CONCLUSION: Both concentrations of tropicamide exhibited comparable effects on anterior segment parameters in diabetic patients. These post-dilation changes should be considered for accurate intraocular lens power calculation and decision-making for cataract, phakic intraocular lens, and refractive surgeries.

20.
Diagnostics (Basel) ; 14(7)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38611620

ABSTRACT

Keratoconus (KC) is the most common corneal ectasia. Optical coherence tomography angiography (OCT-A) is a relatively new non-invasive imaging technique that allows the visualization and quantification of retinal and choriocapillary blood vessels. The aim of this study is to assess retinal and choriocapillary vessel density (VD) differences between KC patients and healthy controls and to investigate correlations between VD and KC severity. Fifty-two eyes were included in this exploratory study: twenty-six eyes from 26 KC patients and twenty-six eyes from 26 age- and gender-matched healthy controls. All patients underwent Scheimpflug corneal topography with Pentacam, axis lengths measurement and optical coherence tomography angiography (OCT-A). The thinnest spot in corneal pachymetry, maximum K (Kmax) and KC severity indices from the Belin/Ambrósio enhanced ectasia display (BAD) were also assessed. There was a distinct reduction particularly in the retinal VD of the superficial capillary plexus (SCP). Correlation analyses showed strong and moderate negative correlations between the VD in the macular SCP and BAD KC scores and between the SCP VD and Kmax. There was no difference in retinal thickness between the KC and healthy controls. With this study, further evidence for altered VD measurements by OCT-A in KC patients is given. For the first time, we demonstrated negative correlations between BAD KC scores and retinal blood vessel alterations. A major limitation of the study is the relatively small sample size. Since an artefactual reduction of the quantitative OCT-A measurements due to irregular corneal topography in KC must be assumed, it remains to be investigated whether there are also actual changes in the retinal microcirculation in KC.

SELECTION OF CITATIONS
SEARCH DETAIL