Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Heliyon ; 10(13): e33019, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39035509

ABSTRACT

Microgrids (MGs) based on renewable energies have emerged as a proficient strategy for tackling power quality issues in conventional distribution networks. Nonetheless, MG systems require a suitable control scheme to supply energy optimally towards the electrical grid. This paper presents an innovative framework for designing hybrid Proportional-Resonant (PR) controllers with Linear Quadratic Regulators (LQR), PR+LQR, which merge relevant properties of PR and LQR controllers. This method simultaneously determines the MG control parameters and the current unbalanced factor generated at the distribution network. We select the traditional IEEE 13-bus test feeder network and place two MGs at strategic locations to validate our approach. Moreover, we use the Grey Wolf Optimizer (GWO) to find control parameters through a reliable fitness function that leads to high-performance microgrids. Finally, we conceive several tests to assess the efficacy of GWO for tuning the hybrid controller and compare the resulting data across distinct realistic operation conditions representing power quality events. So, we choose four case studies considering different renewable energy penetration indexes and power factors and evaluate the effects of the MGs over the distribution grid. We also compare the proposed hybrid PR+LQR controller against closely-related alternatives from the literature and validate its robustness and stability through the disk margin approach and the Nyquist criterion. Our numerical simulations prove that hybrid controllers driven by GWO are highly reliable strategies, yielding an average unbalanced current reduction of 30.03%.

2.
Sci Rep ; 14(1): 12169, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38806572

ABSTRACT

Aiming at the common problems of frequency variations and harmonics in complex power grids, an improved inverse Park transform phase locked loop (IPT-PLL) technology for single-phase converters suitable for micro grid systems is proposed. Firstly, in the phase detection of PLL, the α component of Park transformation is selected as the reference voltage, and its orthogonal component is constructed using a 1/4 fundamental period delay method. Secondly, Lagrange interpolation polynomials are introduced to approximate fractional delay to solve the problem of delay calculation errors caused by frequency changes. Thirdly, in order to compensate for the poor ability of traditional proportional integral (PI) regulators, multi resonant controllers are superimposed to suppress low order harmonic disturbances. Finally, the design method and system performance of the PI regulator and each resonant controller are analyzed theoretically. The experimental results show that the proposed improved IPT-PLL method has strong adaptability to complex power grids. It can significantly improve the tracking performance of power grid frequency, suppress the interference of low order harmonics and DC bias. And it has good dynamic and static performance.

3.
ISA Trans ; 129(Pt B): 535-545, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35193759

ABSTRACT

In this paper, we present a new digital resonant current controller that can be applied in single-phase and three-phase alternating current (AC) power converters, based on voltage source inverters (VSI) with pulse width modulation (PWM). Since power converters based on PWM introduce fractional time delays regarding the sampling period (Ts), because of the current sampling and PWM command updating techniques that are employed, there is a need to develop analytical tools for precise modelling of these types of delays. To achieve this, the advanced Z-transform is applied in order to model the AC controllers in VSIs with PWM for the general case of a fractional time delay, including power converters with current sampling within a PWM period at any chosen time instance. This new approach to power converter modelling and current sampling allowed us to develop a modified resonant AC current controller for a VSI with RL load, based on the pole-placement parameter tuning method. It includes fractional time delays, which are conventionally employed in the power converter design, in the controller parameter derivations, and introduces the minimal order resonant controller that enables strict placement of all closed-loop control system poles. Simulations and experimental tests are carried out to show the improvements introduced by novel solution in this paper compared with conventional resonant current controllers. In the analysis of dynamic performance and robustness, in this paper conventional indices are applied to compare the proposed controller with a conventional design.

SELECTION OF CITATIONS
SEARCH DETAIL