Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters











Publication year range
1.
J Clin Orthop Trauma ; 53: 102472, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39055392

ABSTRACT

Shoulder arthroplasty has become a standard surgical procedure for treating a variety of complex shoulder disorders, including those with degenerative and traumatic aetiologies. The ever-improving success rates of shoulder arthroplasty could be attributed to advancements in endoprosthesis design, improvements in the biomechanics of endoprosthetic components, and improvements in surgical techniques. It improves patient outcomes and helps restore shoulder joint function and mobility. Imaging plays a vital role by enabling surgeons to plan arthroplasty procedures, help guide endoprosthesis placement, and monitor postoperative outcomes. In addition, imaging plays a role in assessing the residual bone stock and status of rotator cuff integrity and in correcting the placement of prosthetic components to restore shoulder mobility. CT-guided navigation aids surgeons by helping them choose appropriate components for implants and ensuring that implants are placed optimally during surgery. It can lead to better surgical results with reduced patient morbidity and a longer duration of prosthetic stability. After surgery, it is crucial to use imaging techniques to detect issues such as periprosthetic loosening, infections, or fractures to start effective management strategies to enhance patient recovery. This article aims to provide orthopaedic surgeons and radiologists with knowledge on the imaging methods used in shoulder arthroplasty and their role in presurgical planning, intraoperative guidance and postoperative assessment. In this study, we aimed to investigate the rationale behind utilising various types of shoulder replacements: total shoulder replacement (TSA), reverse total shoulder arthroplasty (RTSA), and hemiarthroplasty; methods, their respective advantages and limitations; and outcomes. Our objective is to comprehensively analyse the procedures mentioned above and highlight their unique features and benefits to facilitate a better understanding of these approaches. Additionally, we will discuss how these imaging techniques help identify issues such as loose components, fractures around the implant site, joint instability and infections.

2.
Orthop Traumatol Surg Res ; 110(5): 103897, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38663742

ABSTRACT

PURPOSE: The primary purpose of this study was to assess perianchor fluid collection (PFC) severity of medial anchor and rotator cuff integrity association after arthroscopic double-row suture-bridge rotator cuff repair (RCR) and the secondary purpose was to identify the demographic and radiologic risk factors for high-grade PFC. HYPOTHESIS: Re-tear rate would be significant higher in patients with high-grade PFC. METHODS: We retrospectively reviewed patients with arthroscopic double-row suture-bridge RCR for full-thickness rotator cuff tear (RCT) at our institution between February 2012 and May 2018. Based on the PFC severity, they were divided into the no-fluid (no fluid collection), low-grade (minimal or local fluid collection around the anchor), and high-grade (fluid collection beyond the entire length of the anchor) groups. Magnetic resonance imaging was performed 6 months postoperatively for assessing PFC severity and repaired rotator cuff integrity association, besides evaluating correlation between severity and various demographic and radiologic factors, including work level (low/medium/high) and RCT size. RESULTS: This study included 312 patients, 181 (58%) in the no fluid group, 82 (26.3%) in the low-grade PFC group, and 49 (15.7%) in the high-grade PFC group. Re-tear occurred in 73 (23.4%) patients and was more frequent in the high-grade group (26/49 [53.1%]) than in the no-fluid (27/181 [14.9%]; p<0.001) and low-grade (20/82 [24.4%]; p=0.001) groups, without statistically significant differences between the latter two (p=0.082). Among the demographic factors, work level (low/medium/high) differed significantly between the no-fluid (22.1%/58.0%/19.9%), low-grade (25.7%/46.3%/28.0%), and high-grade (26.5%/34.7%/38.8%) groups (p=0.026). Among the radiologic factors, the mediolateral tear size differed significantly between the three groups (no-fluid group: 1.7±0.8cm, low-grade group: 1.8±0.6cm, high-grade group: 2.2±1.0cm; p=0.003). Multivariate regression analysis showed that mediolateral tear size (odds ratio: 1.821; 95% confidence interval: 1.258-2.636; p=0.001) was an independent risk factor for high-grade PFC. CONCLUSIONS: After arthroscopic double-row suture-bridge RCR, the highest re-tear rate was observed in patients with high-grade PFC, while there was no significant difference in rates between no-fluid and low-grade PFC groups. As PFC severity increased, the risk of re-tear increased. In particular, larger mediolateral tear size was associated with high-grade PFC. LEVEL OF EVIDENCE: III; case-control study.


Subject(s)
Arthroscopy , Magnetic Resonance Imaging , Rotator Cuff Injuries , Humans , Rotator Cuff Injuries/surgery , Rotator Cuff Injuries/diagnostic imaging , Retrospective Studies , Male , Female , Middle Aged , Aged , Postoperative Complications/diagnostic imaging , Suture Anchors , Suture Techniques , Risk Factors
3.
J Shoulder Elbow Surg ; 33(3): e153-e161, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37619927

ABSTRACT

BACKGROUND: A high postoperative retear rate after arthroscopic rotator cuff repair (ARCR) of large and massive tears remains a problem. This study evaluated rotator cuff integrity after ARCR with fascia lata graft augmentation for large and massive rotator cuff tears and compared clinical outcomes between patients with intact repairs and retears. METHODS: Forty-five patients with rotator cuff tears who could not undergo primary repair due to tendon retraction underwent arthroscopic medialized single-row repair with fascia lata graft augmentation. The patients' minimum follow-up was 2 (2-9) years. Supraspinatus cuff integrity was evaluated postoperatively by magnetic resonance imaging. We compared the clinical outcomes of patients with intact repairs vs. retears based on the University of California-Los Angeles (UCLA), Constant, and Japanese Orthopaedic Association (JOA) scores. We also evaluated their range of motion (ROM) and muscle strength. RESULTS: Retears were observed in 11 of 45 patients. UCLA, Constant, and JOA scores significantly improved postoperatively compared to preoperatively in the intact repair (all P < .001) and retear (all P < .036) groups. The intact repair group had significantly higher Constant (75.6 [mean] ± 9.9 [SD] vs. 69.8 ± 7.9; P = .026) and JOA (94.4 ± 6.9 vs. 89.8 ± 5.9; P = .041) scores than the retear group. Forward elevation, abduction, and the strengths of abduction and external rotation significantly improved in the intact repair group (all P < .003) but not in the retear group (all P > .05). The intact repair group had significantly higher postoperative forward flexion (165° ± 15° vs. 154° ± 23°; P = .036), abduction (164° ± 17° vs. 151° ± 26°; P = .029), and abduction strength (3.5 ± 2.2 kg vs. 2.3 ± 1.2 kg; P = .017) than the retear group. In the intact repair group (n = 34), Sugaya type I:II ratio differed significantly between postoperative 3 months (2:32) and 24 months (24:10) (P < .001). Repaired tendon thickness did not decrease significantly between 3 months (7.1 mm) and 2 years (6.9 mm) (P = .543). CONCLUSIONS: ARCR with fascia lata graft augmentation of large and massive rotator cuff tears showed a 24.4% retear rate but significantly improved the clinical scores, ROMs, and muscle strength with excellent cuff integrity in the intact repair group. However, the differences in the Constant and UCLA scores between the intact repair and retear groups were under the minimal clinically important difference, and their clinical significance is uncertain. Our results confirm that ARCR with fascia lata graft augmentation improves patients' postoperative outcomes if the repair site is maintained postoperatively.


Subject(s)
Rotator Cuff Injuries , Humans , Rotator Cuff Injuries/surgery , Rotator Cuff Injuries/pathology , Fascia Lata , Treatment Outcome , Rotator Cuff/surgery , Rotator Cuff/pathology , Tendons/surgery , Arthroscopy/methods , Magnetic Resonance Imaging , Range of Motion, Articular
4.
J Shoulder Elbow Surg ; 31(9): 1831-1839, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35367621

ABSTRACT

BACKGROUND: Previous studies reported that micromotion after all-suture anchor implantation can lead to perianchor cyst formation (PCF), leading to risk of retear. Modifying anchor insertion angle (AIA) is known to be one of the various ways to increase anchor stability. However, there currently are few studies that assess the correlation between PCF, AIA, and retear. PURPOSE: To find the correlation of PCF and the repaired rotator cuff integrity with AIA after arthroscopic double-row suture-bridge rotator cuff repair (RCR) using an all-suture anchor in the medial row. METHODS: A total of 218 patients who underwent arthroscopic double-row suture-bridge RCR were retrospectively reviewed. All patients underwent RCR using all-suture anchors and polyether ketone anchors in the medial and lateral rows, respectively. Magnetic resonance imaging was conducted 6 months after the surgery to evaluate PCF, AIA, and integrity of the repaired cuff. The all-suture anchor insertion angle in the medial row was measured with reference to the greater tuberosity to assess the relationship between the AIA and PCF. The correlations between PCF, AIA, and post-RCR integrity were evaluated including various demographic and radiologic factors. RESULTS: Perianchor cysts were formed in 93 patients (42.7%). Mediolateral tear size (2.1 ± 1.2 cm vs. 1.7 ± 0.9 cm, P = .034) and AIA (61.9° ± 15.2° vs. 68.4° ± 13.0°, P = .001) were significantly different between patient groups with and without perianchor cysts. Multivariate logistic regression analysis showed that mediolateral tear size (odds ratio [OR] 1.318, 95% confidence interval [CI] 1.008-1.724; P = .043) and AIA (OR 0.967, 95% CI 0.947-0.988; P = .002) were independent risk factors for PCF. In addition, PCF was observed more frequently (69.6% vs. 32.1%, P < .001) and the AIA was lower (59.4° ± 13.7° vs. 67.8° ± 13.8°, P < .001) in the retear group than in the healed group. CONCLUSIONS: Perianchor cysts were formed in approximately 40% of patients who underwent arthroscopic double-row suture-bridge RCR using all-suture anchors. Low AIA and large mediolateral tear size were risk factors for PCF. Moreover, perianchor cyst and AIA were correlated with post-RCR integrity. Therefore, a high AIA must be carefully considered when all-suture anchors are inserted into the medial row when performing RCR.


Subject(s)
Cysts , Lacerations , Rotator Cuff Injuries , Arthroscopy/methods , Cysts/etiology , Humans , Lacerations/surgery , Magnetic Resonance Imaging , Retrospective Studies , Rotator Cuff/pathology , Rotator Cuff/surgery , Rotator Cuff Injuries/complications , Rupture/surgery , Suture Anchors , Suture Techniques/adverse effects
5.
J Shoulder Elbow Surg ; 30(11): 2506-2513, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33774168

ABSTRACT

BACKGROUND: The clinical significance of rotator cuff muscle quality following reverse total shoulder arthroplasty (RTSA) remains uncertain. The purpose of this study was to evaluate the influence of rotator cuff fatty infiltration (FI) and muscle atrophy (MA) on clinical outcomes following RTSA for glenohumeral osteoarthritis (GHOA). METHODS: One hundred eight shoulders with primary GHOA that underwent RTSA with a lateralized glenosphere for GHOA with a minimum of 2-year follow-up were identified from a prospectively maintained registry. Each rotator cuff muscle was assessed on preoperative magnetic resonance imaging for FI and quantitative amount of MA. Pre- and postoperative outcomes included American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form score, Single Assessment Numerical Evaluation (SANE) score, visual analog scale pain score, and range of motion (ROM) measurements. RESULTS: Eighty-one patients with a mean age of 70.7 ± 5.4 years (range: 57-85) were included who underwent RTSA with a mean follow-up of 2.1 years (range: 2-3.9 years). There was a significant improvement in all outcome measures postoperatively (P < .01). Twenty-two patients (27.1%) had moderate to severe combined infraspinatus and teres minor FI. There was no significant difference in the postoperative external rotation or clinical outcomes compared with those patients with only mild FI (P > .05). Forty-three patients (53.1%) had moderate to severe global rotator cuff FI. There was no significant difference in postoperative outcomes compared with those patients with only mild FI (P < .01). Univariate analysis did not reveal any significant association between the degree of FI or MA of any individual rotator cuff muscle and postoperative clinical outcomes or ROM. The size ratio of the posterior rotator cuff to the subscapularis muscle was positively correlated with preoperative SANE scores but negatively correlated with absolute postoperative and change in preoperative to postoperative SANE scores. However, there were no significant correlations between this size ratio and the other outcome measures. CONCLUSION: Rotator cuff muscle quality as assessed by MA and FI does not impact clinical outcomes following RTSA with a lateralized glenosphere in patients with GHOA and an intact rotator cuff.


Subject(s)
Arthroplasty, Replacement, Shoulder , Osteoarthritis , Rotator Cuff Injuries , Shoulder Joint , Aged , Aged, 80 and over , Humans , Middle Aged , Muscular Atrophy/etiology , Muscular Atrophy/pathology , Osteoarthritis/pathology , Osteoarthritis/surgery , Range of Motion, Articular , Retrospective Studies , Rotator Cuff/pathology , Rotator Cuff/surgery , Rotator Cuff Injuries/pathology , Rotator Cuff Injuries/surgery , Shoulder Joint/pathology , Shoulder Joint/surgery , Treatment Outcome
6.
Am J Sports Med ; 48(6): 1430-1438, 2020 05.
Article in English | MEDLINE | ID: mdl-32267730

ABSTRACT

BACKGROUND: Materials and patches with increased biomechanical and biological properties and superior capsular reconstruction may change the natural history of massive rotator cuff tears (RCTs). PURPOSE: To compare structural and clinical outcomes among 3 surgical techniques for the treatment of massive posterosuperior RCTs: double-row (DR) technique, transosseous-equivalent (TOE) technique with absorbable patch reinforcement, and superior capsular reconstruction (SCR) with the long head of the biceps tendon (LHBT) autograft. STUDY DESIGN: Cohort study; Level of evidence 3. METHODS: We retrospectively analyzed the 3 techniques in patients who underwent repair of massive posterosuperior RCTs between January 2007 and March 2017. All patients completed preoperative and 24-month postoperative evaluations: range of motion, subjective shoulder value, Simple Shoulder Test, American Shoulder and Elbow Surgeons (ASES) score, visual analog scale for pain, and Constant score. Tendon integrity was assessed with ultrasound 1 year postoperatively. RESULTS: A total of 82 patients completed the final evaluation (28 patients, DR; 30 patients, TOE + patch; 24 patients, SCR with LHBT). Groups were statistically comparable preoperatively, except for active forward elevation and tendon retraction, which were significantly worse in the SCR group (P = .008 and P = .001, respectively). After 24 months, the mean ± SD scores for the respective groups were as follows: 76 ± 10, 72 ± 15, and 77 ± 10 for the Constant score (P = .35); 84 ± 10, 84 ± 15, and 80 ± 15 for the ASES (P = .61); 9 ± 2, 9 ± 3, and 8 ± 3 for the Simple Shoulder Test (P = .23); 82 ± 15, 80 ± 18, and 75 ± 18 for the subjective shoulder value (P = .29); and 1.4 ± 1.7, 1.8 ± 2, and 1.4 ± 1.4 for the visual analog scale (P = .65). The strength of the operated shoulder was 4 ± 3 kg, 4.7 ± 3 kg, and 6.4 ± 1.6 kg for the DR, TOE + patch, and SCR groups, respectively (P = .006). At 12 months postoperatively, 60.7% (17 of 28) of the DR group, 56.7% (17 of 30) of the TOE + patch group, and 91.7% (22 of 24) of the SCR group remained healed on ultrasound. The infraspinatus tendon remained healed in 75% of the DR group, 76.5% of the TOE + patch group, and 100% of the SCR with the LHBT group (P = .006). CONCLUSION: In cases of massive posterosuperior RCTs, SCR with the LHBT should be considered a reliable, cost-effective treatment option that protects infraspinatus integrity.


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Arthroscopy/methods , Autografts , Humans , Range of Motion, Articular , Rotator Cuff/surgery , Rotator Cuff Injuries/surgery , Shoulder Joint/surgery , Treatment Outcome
7.
Orthop J Sports Med ; 7(8): 2325967119863432, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31457066

ABSTRACT

BACKGROUND: Acellular dermal matrices (ADMs) have been used in the treatment of shoulders with massive rotator cuff tears (MRCTs). Despite clinical improvement, correlation of clinical findings with ADM integrity on imaging has not been investigated. HYPOTHESIS: The pain in shoulders with MRCTs is partially due to bone-to-bone contact between the tuberosity and acromion. Coverage of the tuberosity with an intact graft or a graft that is torn in a way that the tuberosity remains covered will act as an interpositional tissue, preventing bone-to-bone contact and leading to clinical improvement. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Between 2006 and 2016, a total of 25 shoulders with MRCTs underwent a procedure with an ADM. Pre- and postoperative visual analog scale (VAS) results, American Shoulder and Elbow Surgeons (ASES) score, Hamada grade, and Goutallier classification were reviewed. A postoperative magnetic resonance imaging (MRI) was obtained in 22 (88%) shoulders. The status of the graft was divided into the following categories: type I, intact graft; type II, graft tear with tuberosity covered; and type III, graft tear with tuberosity uncovered (bare). RESULTS: The mean patient age was 61 years (range, 49-73 years), and the mean follow-up was 25.6 months (range, 10-80 months). Mean length from surgery to postoperative MRI was 13.9 months (range, 6-80 months). The graft was torn in 59% (13/22 shoulders). Significant improvements were found in VAS and ASES scores (7 vs 0.7 and 32.6 vs 91.2, respectively; P < .01) for type I grafts and in VAS and ASES scores (8.1 vs 1.3 and 26.3 vs 84.6, respectively; P < .01) for type II grafts. No difference was found in postoperative VAS and ASES (0.7 vs 1.3 and 91.2 vs 84.6, respectively; P = .8) between type I and type II grafts. No improvement was seen in VAS (7.3 vs 5.7; P = .2) or ASES (30.6 vs 37.2; P = .5) for type III grafts. CONCLUSION: MRI appearance of the graft has a significant impact on functional outcomes. Patients with an intact graft or a graft tear leaving the tuberosity covered have lower pain and higher functional scores than those in whom the torn graft leaves the tuberosity uncovered.

8.
J Shoulder Elbow Surg ; 27(11): 2006-2012, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29802062

ABSTRACT

BACKGROUND: This study investigated the feasibility and safety of all-suture anchors in arthroscopic rotator cuff repair. METHODS: All patients were diagnosed with a rotator cuff tear by ultrasound or magnetic resonance imaging (MRI). Patients with partial tears, massive tears, subscapularis tears, or previous shoulder surgery, were excluded. MRI and clinical outcome were investigated in all patients at 1.58 years (range, 1.0-2.0 years) after rotator cuff repair with all-suture anchors (prospective case series). Integrity of the cuff repair, cyst formation (encapsulated fluid signal around the anchor), ingrowth of the bone into the anchor, and integrity of the bone tunnel border were evaluated for 47 anchors. Clinical results were evaluated using the Constant-Murley score. RESULTS: An MRI evaluation was performed in 20 patients at 1.58 years (range, 1.0-2.0 years) after rotator cuff repair with all-suture anchors. MRI evaluation showed a very small rim of fluid around 10% of the anchors. None of the anchors showed cyst formation with fluid diameter more than twice the anchor diameter. In approximately 90% of the anchors, no fluid could be detected between the anchors and the edge of the bony tunnel. Full rotator cuff integrity was seen in 19 patients. Only 1 patient sustained a retear. Clinical results comparable with an arthroscopic rotator cuff repair using classic anchors were seen. CONCLUSIONS: This prospective clinical cohort study shows promising early radiographic and clinical results after arthroscopic rotator cuff repair using all-suture anchors.


Subject(s)
Arthroscopy/instrumentation , Cysts/etiology , Postoperative Complications/etiology , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff Injuries/surgery , Suture Anchors , Adult , Aged , Arthroscopy/adverse effects , Cohort Studies , Cysts/diagnostic imaging , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Postoperative Complications/diagnostic imaging , Suture Techniques/adverse effects , Suture Techniques/instrumentation , Treatment Outcome
9.
Knee Surg Sports Traumatol Arthrosc ; 26(1): 161-168, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28643102

ABSTRACT

PURPOSE: Magnetic resonance (MR) imaging is common in structural and qualitative assessment of the rotator cuff post-operatively. Rotator cuff integrity has been thought to be associated with clinical outcome. The purpose of this study was to evaluate the inter-observer reliability of cuff integrity (Sugaya's classification) and assess the correlation between Sugaya's classification and the clinical outcome. It was hypothesized that Sugaya's classification would show good reliability and good correlation with the clinical outcome. METHODS: Post-operative MR images were taken two years post-operatively, following arthroscopic rotator cuff repair. For assessment of inter-rater reliability, all radiographic evaluations for the supraspinatus muscle were done by two orthopaedic surgeons and one radiologist. Rotator cuff integrity was classified into five categories, according to Sugaya's classification. Fatty infiltration was graded into four categories, based on the Fuchs' classification grading system. Muscle hypotrophy was graded as four grades, according to the scale proposed by Warner. The clinical outcome was assessed according to the constant scoring system pre-operatively and 2 years post-operatively. RESULTS: Of the sixty-two consecutive patients with full-thickness rotator cuff tears, fifty-two patients were reviewed in this study. These subjects included twenty-three men and twenty-nine women, with an average age of fifty-seven years. In terms of the inter-rater reliability between orthopaedic surgeons, Sugaya's classification showed the highest agreement [ICC (2.1) = 0.82] for rotator cuff integrity. The grade of fatty infiltration and muscle atrophy demonstrated good agreement, respectively (0.722 and 0.758). With regard to the inter-rater reliability between orthopaedic surgeon and radiologist, Sugaya's classification showed good reliability [ICC (2.1) = 0.70]. On the other hand, fatty infiltration and muscle hypotrophy classifications demonstrated fair and moderate agreement [ICC (2.1) = 0.39 and 0.49]. Although no significant correlation was found between overall post-operative constant score and Sugaya's classification, Sugaya's classification indicated significant correlation with the muscle strength score. CONCLUSIONS: Sugaya's classification showed repeatability and good agreement between the orthopaedist and radiologist, who are involved in the patient care for the rotator cuff tear. Common classification of rotator cuff integrity with good reliability will give appropriate information for clinicians to improve the patient care of the rotator cuff tear. This classification also would be helpful to predict the strength of arm abduction in the scapular plane. LEVEL OF EVIDENCE: IV.


Subject(s)
Adipose Tissue/diagnostic imaging , Muscle Strength/physiology , Muscular Atrophy/diagnostic imaging , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff/diagnostic imaging , Shoulder/diagnostic imaging , Adult , Aged , Arthroscopy/methods , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Muscular Atrophy/classification , Observer Variation , Postoperative Period , Reproducibility of Results , Rotator Cuff/physiopathology , Rotator Cuff/surgery , Rotator Cuff Injuries/classification , Rotator Cuff Injuries/physiopathology , Rotator Cuff Injuries/surgery , Shoulder/physiopathology , Shoulder/surgery , Treatment Outcome
10.
Bone Joint J ; 99-B(2): 245-249, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28148668

ABSTRACT

AIMS: Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. PATIENTS AND METHODS: We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. RESULTS: There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). CONCLUSION: The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9.


Subject(s)
Minimally Invasive Surgical Procedures/methods , Rotator Cuff Injuries/surgery , Rotator Cuff/surgery , Aged , Aged, 80 and over , Arthroscopy , Female , Humans , Male , Middle Aged , Patient Satisfaction , Recovery of Function , Rotator Cuff/physiopathology , Rotator Cuff Injuries/physiopathology , Wound Healing
SELECTION OF CITATIONS
SEARCH DETAIL