1.
Radiat Oncol ; 19(1): 129, 2024 Sep 27.
Article in English | MEDLINE | ID: mdl-39334165

ABSTRACT

OBJECTIVE: To evaluate the impact of the residual setup errors from differently shaped region of interest (ROI) and investigate if surface-guided setup can be used in radiotherapy with concurrent tumor treating fields (TTFields) for glioblastoma. METHODS: Fifteen patients undergone glioblastoma radiotherapy with concurrent TTFields were involved. Firstly, four shapes of region of interest (ROI) (strip-shaped, T-shaped, ⊥ -shaped and cross-shaped) with medium size relative to the whole face were defined dedicate for patients wearing TTFields transducer arrays. Then, ROI-shape-dependent residual setup errors in six degrees were evaluated using an anthropomorphic head and neck phantom taking CBCT data as reference. Finally, the four types of residual setup errors were converted into corresponding dosimetry deviations (including the target coverage and the organ at risk sparing) of the fifteen radiotherapy plans using a feasible and robust geometric-transform-based method. RESULTS: The algebraic sum of the average residual setup errors in six degrees (mm in translational directions and ° in rotational directions) of the four types were 6.9, 1.1, 4.1 and 3.5 respectively. In terms of the ROI-shape-dependent dosimetry deviations, the D98% of PTV dropped off by (3.4 ± 2.0)% (p < 0.05), (0.3 ± 0.5)% (p < 0.05), (0.9 ± 0.9)% (p < 0.05) and (1.1 ± 0.8)% (p < 0.05). The D98% of CTV dropped off by (0.5 ± 0.6)% (p < 0.05) for the strip-shaped ROI while remained unchanged for others. CONCLUSION: Surface-guided setup is feasible in radiotherapy with concurrent TTFields and a medium-sized T-shaped ROI is appropriate for the surface-based guidance.


Subject(s)
Feasibility Studies , Glioblastoma , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided , Humans , Glioblastoma/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Organs at Risk/radiation effects , Phantoms, Imaging , Brain Neoplasms/radiotherapy , Female , Male , Middle Aged , Radiotherapy Setup Errors/prevention & control , Radiotherapy, Intensity-Modulated/methods , Aged , Cone-Beam Computed Tomography
2.
J Appl Clin Med Phys ; : e14510, 2024 Sep 17.
Article in English | MEDLINE | ID: mdl-39287562

ABSTRACT

PURPOSE: The aim of this study was to assess the accuracy of a surface-guided radiotherapy (SGRT) system for setup and intra-fraction motion control in frameless non-coplanar stereotactic radiosurgery (fSRS) using actual patient data immobilized with two different types of open-faced masks and employing a novel SGRT systems settings. METHODS AND MATERIALS: Forty-four SRS patients were immobilized with two types of open-faced masks. Sixty lesions were treated, involving the analysis of 68 cone-beam scans (CBCT), 157 megavoltage (MV) images, and 521 SGRT monitoring sessions. The average SGRT translations/rotations and 3D vectors (MAG-Trasl and MAG-Rot) were compared with CBCT or antero-posterior MV images for 0° table or non-coplanar beams, respectively. The intrafraction control was evaluated based on the average shifts obtained from each monitoring session. To assess the association between the SGRT system and the CBCT, the two types of masks and the 3D vectors, a generalized estimating equations (GEE) regression analysis was performed. The Wilcoxon singed-rank test for paired samples was performed to detect differences in couch rotation with longitudinal (LNG) and lateral (LAT) translations and/or yaw. RESULTS: The average SGRT corrections were smaller than those detected by CBCT (≤0.5 mm and 0.1°), with largest differences in LNG and yaw. The GEE analysis indicated that the average MAG-Trasl, obtained by the SGRT system, was not statistically different (p = 0.09) for both mask types, while, the MAG-Rot was different (p = 0.01). For non-coplanar beams, the Wilcoxon singed-rank test demonstrated no significantly differences for the corrections (LNG, LAT, and yaw) for any table rotation except for LNG corrections at 65° (p = 0.04) and 75° (p = 0.03) table angle position; LAT shifts at 65° (p = 0.03) and 270° (p < 0.001) table angle position, and yaw rotation at 30° (p = 0.02) table angle position. The average intrafraction motion was < 0.1 mm and 0.1° for any table angle. CONCLUSION: The SGRT system used, along with the novel workflow performed, can achieve the setup and intra-fraction motion control accuracy required to perform non-coplanar fSRS treatments. Both masks ensure the accuracy required for fSRS while providing a suitable surface for monitoring.

3.
Crit Rev Oncol Hematol ; 204: 104518, 2024 Sep 20.
Article in English | MEDLINE | ID: mdl-39299409

ABSTRACT

In recent years, alternative methods to dark ink tattoos for patient positioning in radiotherapy have been explored. This review aims to analyse the evidence for alternative strategies to traditional dark tattoos. An electronic search was conducted in PubMed, EMBASE, Cochrane Library, Web of Sciences and SCOPUS. Twenty-one articles out of 383 titles fulfilled the selection criteria and were included in the review. These studies were categorized into tattoo-less methods (n=14), UV ink tattoos (n=4) and other techniques (n=3). In most of the selected articles (n=13) focusing on tattoo-less treatments, SGRT is used for patient positioning. These three alternative techniques to dark tattoos are used in different anatomical regions and treatment modalities, with breast cancer being the most prevalent. Tattoo-less techniques are a promising alternative to traditional tattoo-based methods for patient positioning. They have the potential to improve the patient experience and represent an area of ongoing innovation and improvement.

4.
Radiother Oncol ; 199: 110471, 2024 10.
Article in English | MEDLINE | ID: mdl-39127406

ABSTRACT

BACKGROUND AND PURPOSE: The quality of the Cone Beam Computed Tomography (CBCT) images used for patient set-up is essential to avoid geographical miss when narrower margins or shorter fractionation are used for example in Accelerated Partial Breast Irradiation (APBI). This study evaluates deep inspiration breath hold (DIBH) with skin guided radiotherapy as a tool for image improvement reducing motion artifacts. MATERIALS AND METHODS: Daily CBCT images of left and right breast cancer patients with well-defined surgical cavity on CT simulation were used for this study. Only left sided CBCT were acquired with DIBH. Trained and experienced radiation therapists were asked to evaluate the image quality using a cavity visualization score (CVS), an image quality Likert score, and to perform registration shifts. Images were anonymized and therapists were blinded to the use of DIBH. RESULTS: Images from 21 patients, with 15 CBCT each, were evaluated by 6 radiation therapists, generating 4,015 evaluation points. Statistically significant improvements were observed in CVS and image quality (p < 0.001) with DIBH. Also, the rate of surgical cavity identification increased to 76 % with DIBH compared to 56 % without (p < 0.001). DIBH significantly reduced the inter-observer variability in registration shift corrections (p < 0.001) CONCLUSION: Utilizing DIBH for motion control improves both the image quality and the surgical cavity identification. This results in a decrease in registration variability, which is important for APBI accuracy.


Subject(s)
Breast Neoplasms , Breath Holding , Cone-Beam Computed Tomography , Radiotherapy, Image-Guided , Humans , Cone-Beam Computed Tomography/methods , Female , Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Breast Neoplasms/diagnostic imaging , Radiotherapy, Image-Guided/methods , Radiotherapy Planning, Computer-Assisted/methods , Artifacts , Middle Aged , Inhalation
5.
J Appl Clin Med Phys ; 25(10): e14463, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39138877

ABSTRACT

PURPOSE: This study investigated the use of surface guided radiotherapy (SGRT) in combination with a tomotherapy treatment mode using discrete delivery angles for deep inspiration breath hold (DIBH) treatments of breast cancer (bc). We aimed to assess the feasibility and dosimetric advantages of this approach. MATERIALS AND METHODS: We evaluated camera occlusion in the Radixact treatment system bore and the stability of DIBH signals during couch movement. The SGRT system's ability to maintain signal and surface image accuracy was analyzed at different depths within the bore. Dosimetric parameters were compared and measured for 20 left-sided bc patients receiving TomoDirect (TD) tangential radiotherapy in both DIBH and free breathing (FB). RESULTS: The SGRT system maintained surface coverage and precise DIBH-signal at depths up to 40 cm beyond the treatment center. Camera occlusion occurred in the clavicular and neck regions due to the patient's morphology and gantry geometry. Nonetheless, the system accurately detected respiratory motion for all measurements. The DIBH plans significantly (p < 0.001) reduced mean heart and left anterior descending artery (LAD) radiation doses by up to 40%, with a 50% reduction in near-maximum heart and LAD doses, respectively. No significant dosimetric differences between DIBH and FB were observed in other investigated parameters and volumes. CONCLUSIONS: Camera occlusion and couch movement minimally impacted the real-time surface image accuracy needed for DIBH treatments of bc. DIBH reduced heart and LAD radiation doses significantly compared to FB, indicating the feasibility and dosimetric benefits of combining these modalities.


Subject(s)
Breast Neoplasms , Breath Holding , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Humans , Female , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Organs at Risk/radiation effects , Breast Neoplasms/radiotherapy , Radiotherapy, Image-Guided/methods , Respiration , Prognosis , Inhalation
6.
Technol Cancer Res Treat ; 23: 15330338241271946, 2024.
Article in English | MEDLINE | ID: mdl-39109645

ABSTRACT

PURPOSE: To improve the setup reproducibility of neck curvature using real-time optical surface imaging (OSI) guidance on 2 regions of interest (ROIs) to infer cervical spine (c-spine) curvature for surface-guided radiotherapy (SGRT) of head-and-neck (HN) and c-spine cancer. METHODS: A novel SGRT setup approach was designed to reproduce neck curvature with 2 ROIs: upper-chest ROI and open-face ROI. It was hypothesized that the neck curvature could be reproduced if both ROIs were aligned within ±3 mm/2˚ tolerance. This was tested prospectively in 7 volunteers using real-time 3D-OSI guidance and lateral 2D-photography verification after the 3D and 2D references were captured from the initial conventional setup. Real-time SGRT was performed to align chest-ROI and face-ROI, and the longitudinal distance between them was adjustable using a head-support slider. Verification of neck curvature anteriorly and posteriorly was achieved by overlaying edge-extracted lateral pictures. Retrospectively, the relationship between anterior surface and spinal canal alignment was checked in 11 patients using their simulation CT (simCT) and setup cone-beam CT (CBCT). After the anterior surface was rigidly aligned, the spinal canal alignment was checked and quantified using the mean-distance-to-agreement (MDA) and DICE similarity index, and surface-to-spine correlation was calculated. RESULTS: The reproducibility of neck curvatures using the 2xROI SGRT setup is verified and the mean neck-outline-matching difference is within ±2 mm in lateral photographic overlays. The chest-ROI alignment takes 110 ± 58 s and the face-ROI takes 60 ± 35 s. When the anterior body surface is aligned (MDA = 1.1 ± 0.6 mm, DICE = 0.96 ± 0.02,) the internal spinal canal is also aligned (MDA = 1.0 ± 0.3 mm, DICE = 0.84 ± 0.04) in 11 patients. The surface-to-spine correlation is c = 0.90 (MDA) and c = 0.85 (DICE). CONCLUSION: This study demonstrates the feasibility of the novel 2-ROI SGRT setup technique to achieve reproducible neck and c-spine curvature regardless of neck visibility and availability as ROI. Staff training is needed to adopt this unconventional SGRT technique to improve patient setup.


Subject(s)
Cone-Beam Computed Tomography , Head and Neck Neoplasms , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided , Humans , Head and Neck Neoplasms/radiotherapy , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/pathology , Male , Radiotherapy, Image-Guided/methods , Female , Cone-Beam Computed Tomography/methods , Radiotherapy Planning, Computer-Assisted/methods , Middle Aged , Feasibility Studies , Aged , Neck , Adult , Reproducibility of Results , Imaging, Three-Dimensional/methods , Cervical Vertebrae/diagnostic imaging
7.
Cancers (Basel) ; 16(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-39001420

ABSTRACT

Image-guided radiotherapy supported by surface guidance can help to track lower lung lesions' respiratory motion while reducing a patient's exposure to ionizing radiation. However, it is not always clear how the skin's respiratory motion magnitude and its correlation with the lung lesion's respiratory motion vary between different skin regions of interest (ROI). Four-dimensional computed tomography (4DCT) images provide information on both the skin and lung respiratory motion and are routinely acquired for the purpose of treatment planning in our institution. An analysis of 4DCT images for 57 patients treated in our institution has been conducted to provide information on the respiratory motion magnitudes of nine skin ROIs of the torso, a tracking structure (TS) representing a lower lung lobe lesion, as well as the respiratory motion correlations between the nine ROIs and the TS. The effects of gender and the adipose tissue volume and distribution on these correlations and magnitudes have been analyzed. Significant differences between the ROIs in both the respiratory motion magnitudes and their correlations with the TS have been detected. An overall negative correlation between the ROI respiratory magnitudes and the adipose tissue has been detected for ROIs with rib cage support. A weak to moderate negative correlation between the adipose tissue volume and ROI-to-TS respiratory correlations has been detected for upper thorax ROIs. The respiratory magnitudes in regions without rib support tend to be larger for men than for women, but no differences in the ROI-to-TS correlation between sexes have been detected. The described findings should be considered when choosing skin surrogates for lower lung lesion motion management.

8.
Med Dosim ; 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38910070

ABSTRACT

Respiratory motion management is the crucial challenge for safe and effective application of lung stereotactic body radiotherapy (SBRT). The present study implemented lung SBRT treatment in voluntary deep inspiration breath-hold (DIBH) with surface-guided radiotherapy (SGRT) system and evaluated the geometric and dosimetric benefits of DIBH to organs-at-risk (OARs), aiming to advising the choice between DIBH technology and conventional free breathing 4 dimensions (FB-4D) technology. Five patients of lung SBRT treated in DIBH with SGRT at our institution were retrospectively analyzed. CT scans were acquired in DIBH and FB-4D, treatment plans were generated for both respiratory phases. The geometric and dosimetry of tumor, ipsilateral lung, double lungs and heart were compared between the DIBH and FB-4D treatment plans. In terms of target coverage, utilizing DIBH significantly reduced the mean plan target volume (PTV) by 21.9% (p = 0.09) compared to FB-4D, the conformity index (CI) of DIBH and FB-4D were comparable, but the dose gradient index (DGI) of DIBH was higher. With DIBH expanding lung, the volumes of ipsilateral lung and double lungs were 2535.1 ± 403.0cm3 and 4864.3 ± 900.2cm3, separately, 62.2% (p = 0.009) and 73.1% (p = 0.009) more than volumes of ipsilateral lung (1460.03 ± 146.60cm3) and double lungs (2811.25 ± 603.64cm3) in FB-4D. The heart volume in DIBH was 700.0 ± 146.1cm3, 11.6% (p = 0.021) less than that in FB-4D. As for OARs protection, the mean dose, percent of volume receiving > 20Gy (V20) and percent of volume receiving > 5Gy (V5) of ipsilateral lung in DIBH were significantly lower by 33.2% (p = 0.020), 44.0% (p = 0.022) and 24.5% (p = 0.037) on average, separately. Double lungs also showed significant decrease by 31.1% (p = 0.019), 45.5% (p = 0.024) and 20.9% (p = 0.048) on average for mean dose, V20 and V5 in DIBH. Different from the lung, the mean dose and V5 of heart showed no consistency between DIBH and FB-4D, but lower maximum dose of heart was achieved in DIBH for all patients in this study. Appling lung SBRT in DIBH with SGRT was feasibly performed with high patient compliance. DIBH brought significant dosimetric benefits to lung, however, it caused more or less irradiated heart dose that depend on the patients' individual differences which were unpredictable.

9.
J Appl Clin Med Phys ; 25(8): e14381, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38696715

ABSTRACT

BACKGROUND: Surface-guided radiotherapy (SGRT) is adopted by several institutions; however, reports on the phantoms used to assess the precision of the SGRT setup are limited. PURPOSE: The purpose of this study was to develop a phantom to verify the accuracy of the irradiation position during skin mark-less SGRT. METHODS: An acrylonitrile butadiene styrene (ABS) plastic cube phantom with a diameter of 150 mm on each side containing a dummy target of 15 mm and two types of body surface-shaped phantoms (breast/face shape) that could be attached to the cube phantom were fabricated. Films can be inserted on four sides of the cubic phantom (left, right, anterior and posterior), and the center of radiation can be calculated by irradiating the dummy target with orthogonal MV beams. Three types of SGRT using a VOXELAN-HEV600M (Electronics Research&Development Corporation, Okayama, Japan) were evaluated using this phantom: (i) SGRTCT-a SGRT set-up based solely on a computed tomography (CT)-reference image. (ii) SGRTCT + CBCT-a method where cone beam computed tomography (CBCT) matching was performed after SGRTCT. (iii) SGRTScan-a resetup technique using a scan reference image obtained after completing the (ii) step. RESULTS: Both the breast and face phantoms were recognized in the SGRT system without problems. SGRTScan ensure precision within 1 mm/1° for breast and face verification, respectively. All SGRT methods showed comparable rotational accuracies with no significant disparities. CONCLUSIONS: The developed phantom was useful for verifying the accuracy of skin mark-less SGRT position matching. The SGRTScan demonstrated the feasibility of achieving skin-mark less SGRT with high accuracy, with deviations of less than 1 mm. Additional research is necessary to evaluate the suitability of the developed phantoms for use in various facilities and systems. This phantom could be used for postal surveys in the future.


Subject(s)
Cone-Beam Computed Tomography , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided , Humans , Radiotherapy, Image-Guided/methods , Radiotherapy, Image-Guided/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Cone-Beam Computed Tomography/methods , Radiotherapy, Intensity-Modulated/methods , Skin/radiation effects , Radiotherapy Setup Errors/prevention & control , Image Processing, Computer-Assisted/methods
10.
J Appl Clin Med Phys ; 25(7): e14319, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38522035

ABSTRACT

BACKGROUND AND PURPOSE: By employing three surface-guided radiotherapy (SGRT)-assisted positioning methods, we conducted a prospective study of patients undergoing SGRT-based deep inspiration breath-hold (DIBH) radiotherapy using a Sentine/Catalys system. The aim of this study was to optimize the initial positioning workflow of SGRT-DIBH radiotherapy for breast cancer. MATERIALS AND METHODS: A total of 124 patients were divided into three groups to conduct a prospective comparative study of the setup accuracy and efficiency for the daily initial setup of SGRT-DIBH breast radiotherapy. Group A was subjected to skin marker plus SGRT verification, Group B underwent SGRT optical feedback plus auto-positioning, and Group C was subjected to skin marker plus SGRT auto-positioning. We evaluated setup accuracy and efficiency using cone-beam computed tomography (CBCT) verification data and the total setup time. RESULTS: In groups A, B, and C, the mean and standard deviation of the translational setup-error vectors were small, with the highest values of the three directions observed in group A (2.4 ± 1.6, 2.9 ± 1.8, and 2.8 ± 2.1 mm). The rotational vectors in group B (1.8 ± 0.7°, 2.1 ± 0.8°, and 1.8 ± 0.7°) were significantly larger than those in groups A and C, and the Group C setup required the shortest amount of time, at 1.5 ± 0.3 min, while that of Group B took the longest time, at 2.6 ± 0.9 min. CONCLUSION: SGRT one-key calibration was found to be more suitable when followed by skin marker/tattoo and in-room laser positioning, establishing it as an optimal daily initial set-up protocol for breast DIBH radiotherapy. This modality also proved to be suitable for free-breathing breast cancer radiotherapy, and its widespread clinical use is recommended.


Subject(s)
Breast Neoplasms , Breath Holding , Cone-Beam Computed Tomography , Patient Positioning , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Female , Breast Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Prospective Studies , Cone-Beam Computed Tomography/methods , Middle Aged , Radiotherapy, Intensity-Modulated/methods , Aged , Radiotherapy, Image-Guided/methods , Radiotherapy Setup Errors/prevention & control , Adult , Prognosis , Fiducial Markers , Organs at Risk/radiation effects
11.
Br J Radiol ; 97(1157): 980-992, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38547402

ABSTRACT

OBJECTIVES: To develop a mapping model between skin surface motion and internal tumour motion and deformation using end-of-exhalation (EOE) and end-of-inhalation (EOI) 3D CT images for tracking lung tumours during respiration. METHODS: Before treatment, skin and tumour surfaces were segmented and reconstructed from the EOE and the EOI 3D CT images. A non-rigid registration algorithm was used to register the EOE skin and tumour surfaces to the EOI, resulting in a displacement vector field that was then used to construct a mapping model. During treatment, the EOE skin surface was registered to the real-time, yielding a real-time skin surface displacement vector field. Using the mapping model generated, the input of a real-time skin surface can be used to calculate the real-time tumour surface. The proposed method was validated with and without simulated noise on 4D CT images from 15 patients at Léon Bérard Cancer Center and the 4D-lung dataset. RESULTS: The average centre position error, dice similarity coefficient (DSC), 95%-Hausdorff distance and mean distance to agreement of the tumour surfaces were 1.29 mm, 0.924, 2.76 mm, and 1.13 mm without simulated noise, respectively. With simulated noise, these values were 1.33 mm, 0.920, 2.79 mm, and 1.15 mm, respectively. CONCLUSIONS: A patient-specific model was proposed and validated that was constructed using only EOE and EOI 3D CT images and real-time skin surface images to predict internal tumour motion and deformation during respiratory motion. ADVANCES IN KNOWLEDGE: The proposed method achieves comparable accuracy to state-of-the-art methods with fewer pre-treatment planning CT images, which holds potential for application in precise image-guided radiation therapy.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms , Skin , Humans , Lung Neoplasms/diagnostic imaging , Four-Dimensional Computed Tomography/methods , Skin/diagnostic imaging , Inhalation , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Exhalation/physiology , Imaging, Three-Dimensional/methods , Respiration , Tomography, X-Ray Computed/methods
12.
J Appl Clin Med Phys ; 25(2): e14263, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38268200

ABSTRACT

BACKGROUND: Surface-guided radiation therapy (SGRT) systems have been widely installed and utilized on linear accelerators. However, the use of SGRT with proton therapy is still a newly developing field, and published reports are currently very limited. PURPOSE: To assess the clinical application and alignment agreement of SGRT with CT-on-rails (CTOR) and kV-2D image-guided radiation therapy (IGRT) for breast treatment using proton therapy. METHODS: Four patients receiving breast or chest wall treatment with proton therapy were the subjects of this study. Patient #1's IGRT modalities were a combination of kV-2D and CTOR. CTOR was the only imaging modality for patients #2 and #3, and kV-2D was the only imaging modality for patient #4. The patients' respiratory motions were assessed using a 2-min surface position recorded by the SGRT system during treatment. SGRT offsets reported after IGRT shifts were recorded for each fraction of treatment. The agreement between SGRT and either kV-2D or CTOR was evaluated. RESULTS: The respiratory motion amplitude was <4 mm in translation and <2.0° in rotation for all patients. The mean and maximum amplitude of SGRT offsets after application of IGRT shifts were ≤(2.6 mm, 1.6° ) and (6.8 mm, 4.5° ) relative to kV-2D-based IGRT; ≤(3.0 mm, 2.6° ) and (5.0 mm, 4.7° ) relative to CTOR-based IGRT without breast tissue inflammation. For patient #3, breast inflammation was observed for the last three fractions of treatment, and the maximum SGRT offsets post CTOR shifts were up to (14.0 mm, 5.2° ). CONCLUSIONS: Due to the overall agreement between SGRT and IGRT within reasonable tolerance, SGRT has the potential to serve as a valuable auxiliary IGRT tool for proton breast treatment and may improve the efficiency of proton breast treatment.


Subject(s)
Radiotherapy, Image-Guided , Thoracic Wall , Humans , Radiotherapy, Image-Guided/methods , Protons , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed , Inflammation
13.
J Appl Clin Med Phys ; 25(6): e14271, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38273673

ABSTRACT

PURPOSE: The use of volumetric modulated arc therapy (VMAT), simultaneous integrated boost (SIB), and hypofractionated regimen requires adequate patient setup accuracy to achieve an optimal outcome. The purpose of this study was to assess the setup accuracy of patients receiving left-sided breast cancer radiotherapy using deep inspiration breath-hold technique (DIBH) and surface guided radiotherapy (SGRT) and to calculate the corresponding setup margins. METHODS: The patient setup accuracy between and within radiotherapy fractions was measured by comparing the 6DOF shifts made by the SGRT system AlignRT with the shifts made by kV-CBCT. Three hundred and three radiotherapy fractions of 23 left-sided breast cancer patients using DIBH and SGRT were used for the analysis. All patients received pre-treatment DIBH training and visual feedback during DIBH. An analysis of variance (ANOVA) was used to test patient setup differences for statistical significance. The corresponding setup margins were calculated using the van Herk's formula. RESULTS: The intrafractional patient setup accuracy was significantly better than the interfractional setup accuracy (p < 0.001). The setup margin for the combined inter- and intrafractional setup error was 4, 6, and 4 mm in the lateral, longitudinal, and vertical directions if based on SGRT alone. The intrafractional error contributed ≤1 mm to the calculated setup margins. CONCLUSION: With SGRT, excellent intrafractional and acceptable interfractional patient setup accuracy can be achieved for the radiotherapy of left-sided breast cancer using DIBH and modern radiation techniques. This allows for reducing the frequency of kV-CBCTs, thereby saving treatment time and radiation exposure.


Subject(s)
Breath Holding , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy Setup Errors , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Unilateral Breast Neoplasms/radiotherapy , Radiotherapy Setup Errors/prevention & control , Radiotherapy, Image-Guided/methods , Organs at Risk/radiation effects , Middle Aged , Breast Neoplasms/radiotherapy , Prognosis
14.
J Med Imaging Radiat Sci ; 55(1): 29-36, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38016852

ABSTRACT

INTRODUCTION: Both cone-beam computed tomography (CBCT) and surface-guided radiotherapy (SGRT) are used for breast patient positioning verification before treatment delivery. SGRT may reduce treatment time and imaging dose by potentially reduce the number of CBCT needed. The aim of this study was to compare the displacements resulting in positioning from the Image Guided Radiation Therapy (IGRT) 3D and SGRT methods and to design a clinical workflow for SGRT implementation in breast radiotherapy to establish an imaging strategy based on the data obtained. METHODS: For this study 128 breast cancer patients treated with 42.5 Gy in 16 fractions using 3D conformal radiotherapy with free breathing technique were enroled. A total of 366 CBCT images were evaluated for patient setup verification and compared with SGRT. Image registrations between planning CT images and CBCT images were performed in mutual agreement and in online mode by three health professionals. Student's paired t-test was used to compare the absolute difference in vector shift, measured in mm, for each orthogonal axis (x, y, z) between SGRT and CBCT methods. The multidisciplinary team evaluated a review of the original clinical workflow for SGRT implementation and data about patients treated with the updated workflow were reported. RESULTS: Comparison of the shifts obtained with IGRT and SGRT for each orthogonal axis (for the x-axes the average displacement was 0.9 ± 0.7 mm, y = 1.1 ± 0.8 mm and z = 1.0 ± 0.7 mm) revealed no significant statistical differences (p > 0.05). Using the updated workflow the difference between SGRT and IGRT displacements was <3 mm in 91.4 % of patients with a reduction in total treatment time of approximately 20 %, due to the reduce frequency of the CBCT images acquisition and matching. CONCLUSIONS: This study has shown that IGRT and SGRT agree in positioning patients with breast cancer within a millimetre tolerance. SGRT can be used for patient positioning, with the advantages of reducing radiation exposure and shorter overall treatment time.


Subject(s)
Breast Neoplasms , Radiotherapy, Intensity-Modulated , Spiral Cone-Beam Computed Tomography , Female , Humans , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Image Processing, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies
15.
Phys Imaging Radiat Oncol ; 27: 100455, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37720462

ABSTRACT

Background and purpose: Spirometry induced deep-inspiration-breath-hold (DIBH) reduces intrafractional motion during upper abdominal stereotactic body radiotherapy (SBRT). The aim of this prospective study was to evaluate whether surface scanning (SGRT) is an adequate surrogate for monitoring residual internal motion during DIBH. Residual motion detected by SGRT was compared with experimental 4D-ultrasound (US) and an internal motion detection benchmark (diaphragm-dome-position in kV cone-beam computed tomography (CBCT) projections). Materials and methods: Intrafractional monitoring was performed with SGRT and US in 460 DIBHs of 12 patients. Residual motion detected by all modalities (SGRT (anterior-posterior (AP)), US (AP, craniocaudal (CC)) and CBCT (CC)) was analyzed. Agreement analysis included Wilcoxon signed rank test, Maloney and Rastogi's test, Pearson's correlation coefficient (PCC) and interclass correlation coefficient (ICC). Results: Interquartile range was 0.7 mm (US(AP)), 0.8 mm (US(CC)), 0.9 mm (SGRT) and 0.8 mm (CBCT). SGRT(AP) vs. CBCT(CC) and US(CC) vs. CBCT(CC) showed comparable agreement (PCCs 0.53 and 0.52, ICCs 0.51 and 0.49) with slightly higher precision of CBCT(CC). Most agreement was observed for SGRT(AP) vs. US(AP) with largest PCC (0.61) and ICC (0.60), least agreement for SGRT(AP) vs. US(CC) with smallest PCC (0.44) and ICC (0.42). Conclusions: Residual motion detected during spirometry induced DIBH is small. SGRT alone is no sufficient surrogate for residual internal motion in all patients as some high velocity motion could not be detected. Observed patient-specific residual errors may require individualized PTV-margins.

16.
Cancer Radiother ; 27(6-7): 504-510, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37558608

ABSTRACT

In radiotherapy, patient positioning has long been ensured by ionizing imaging (kV or MV). Over the past ten years, surface-guided radiotherapy has appeared in radiotherapy departments. It is a continuous three-dimensional acquisition of the surface of the patient, based on the use of several optical cameras. The acquired surface is compared to an expected surface (usually taken from the planning scanner). Operators can constantly appreciate poor position, anatomical deformity or patient shift. Thus, the system allows an aid to the positioning of the patient, possibly without tattooing, but also a follow-up of the patient during the duration of the session. The most obvious contribution of the system concerns the treatment of the breast. In fact, for this location, the bone registration is not ideal and the target is visible in surface-guided radiotherapy. These systems also make it possible to treat in deep inspiration breath hold. But several other locations can benefit from it (pelvis, thorax, etc.).


Subject(s)
Brachytherapy , Radiation Oncology , Radiotherapy, Image-Guided , Humans , Radiotherapy, Image-Guided/methods , Brachytherapy/methods , Radiotherapy Planning, Computer-Assisted
17.
J Appl Clin Med Phys ; 24(12): e14133, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37643456

ABSTRACT

PURPOSE: With the clinical implementation of kV-CBCT-based daily online-adaptive radiotherapy, the ability to monitor, quantify, and correct patient movement during adaptive sessions is paramount. With sessions lasting between 20-45 min, the ability to detect and correct for small movements without restarting the entire session is critical to the adaptive workflow and dosimetric outcome. The purpose of this study was to quantify and evaluate the correlation of observed patient movement with machine logs and a surface imaging (SI) system during adaptive radiation therapy. METHODS: Treatment machine logs and SGRT registration data log files for 1972 individual sessions were exported and analyzed. For each session, the calculated shifts from a pre-delivery position verification CBCT were extracted from the machine logs and compared to the SGRT registration data log files captured during motion monitoring. The SGRT calculated shifts were compared to the reported shifts of the machine logs for comparison for all patients and eight disease site categories. RESULTS: The average (±STD) net displacement of the SGRT shifts were 2.6 ± 3.4 mm, 2.6 ± 3.5 mm, and 3.0 ± 3.2 in the lateral, longitudinal, and vertical directions, respectively. For the treatment machine logs, the average net displacements in the lateral, longitudinal, and vertical directions were 2.7 ± 3.7 mm, 2.6 ± 3.7 mm, and 3.2 ± 3.6 mm. The average difference (Machine-SGRT) was -0.1 ± 1.8 mm, 0.2 ± 2.1 mm, and -0.5 ± 2.5 mm for the lateral, longitudinal, and vertical directions. On average, a movement of 5.8 ± 5.6 mm and 5.3 ± 4.9 mm was calculated prior to delivery for the CBCT and SGRT systems, respectively. The Pearson correlation coefficient between CBCT and SGRT shifts was r = 0.88. The mean and median difference between the treatment machine logs and SGRT log files was less than 1 mm for all sites. CONCLUSION: Surface imaging should be used to monitor and quantify patient movement during adaptive radiotherapy.


Subject(s)
Radiotherapy, Image-Guided , Spiral Cone-Beam Computed Tomography , Humans , Radiotherapy, Image-Guided/methods , Patient Positioning/methods , Radiotherapy Planning, Computer-Assisted/methods , Movement , Radiotherapy Dosage , Cone-Beam Computed Tomography/methods
18.
Radiat Oncol ; 18(1): 112, 2023 Jul 05.
Article in English | MEDLINE | ID: mdl-37408037

ABSTRACT

PURPOSE: Surface-guided radiotherapy (SGRT) has been demonstrated to be a promising supplement to cone-beam computed tomography (CBCT) in adjuvant breast cancer radiotherapy, but a rational combination mode is lacking in clinical practice. The aim of this study was to explore this mode and investigate its impact on the setup and dose accuracy. METHODS AND MATERIALS: Daily SGRT and weekly CBCT images were acquired for 23 patients with breast cancer who received conventional fractionated radiotherapy after lumpectomy. Sixteen modes were acquired by randomly selecting one (CBCT1), two (CBCTij), three (CBCTijk), four (CBCTijkl), and five (CBCT12345) images from the CBCT images for fusion with the SGRT. The CTV-PTV margins, OAR doses, and dose coverage (V95%) of PTV and CTV was calculated based on SGRT setup errors with different regions of interest (ROIs). Dose correlations between these modalities were investigated using Pearson and Spearman's methods. Patient-specific parameters were recorded to assess their impact on dose. RESULTS: The CTV-PTV margins decreased with increasing CBCT frequencies and were close to 5 mm for CBCTijkl and CBCT12345. For the ipsilateral breast ROI, SGRT errors were larger in the AP direction, and target doses were higher in all modes than in the whole breast ROI (P < 0.05). In the ipsilateral ROI, the target dose correlations between all modes increased with increasing CBCT time intervals, decreased, and then increased with increasing CBCT frequencies, with the inflection point being CBCT participation at week 5. The dose deviations in CBCT123, CBCT124, CBCT125, CBCTijkl, and CBCT12345 were minimal and did not differ significantly (P > 0.05). There was excellent agreement between CBCT124 and CBCT1234, and between (CBCTijkl, CBCT12345) and CBCT125 in determining the classification for the percentage of PTV deviation (Kappa = 0.704-0.901). In addition, there were weak correlations between the patient's Dips_b (ipsilateral breast diameter with bolus) and CTV doses in modes with CBCT participation at week 4 (R = 0.270 to 0.480). CONCLUSIONS: Based on weekly CBCT, these modes with ipsilateral ROI and a combination of daily SGRT and a CBCT frequency of ≥ 3 were recommended, and CBCT was required at weeks 1 and 2 for CBCTijk.


Subject(s)
Brachytherapy , Breast Neoplasms , Radiotherapy, Image-Guided , Humans , Female , Radiotherapy, Image-Guided/methods , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Dose Fractionation, Radiation , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Cone-Beam Computed Tomography/methods
19.
J Appl Clin Med Phys ; 24(10): e14058, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37289550

ABSTRACT

PURPOSE: To commission and assess the clinical performance of a new commercial surface imaging (SI) system by analyzing intra-fraction motion from the initial cohort of patients treated with frameless stereotactic radiosurgery (fSRS). METHODS: The IDENTIFYTM SI system was commissioned for clinical use on an Edge (Varian Medical Systems, Palo Alto, CA) linear accelerator. All patients who received intracranial radiotherapy with HyperArcTM (Varian Medical Systems, Palo Alto, CA) were immobilized with the EncompassTM (Qfix, Avondale, PA) thermoplastic mask and monitored for intra-fraction motion with SI. IDENTIFYTM log files were correlated with trajectory log files to correlate treatment parameters with SI-reported offsets. IDENTIFYTM reported offsets were correlated with gantry and couch angles to assess system performance for obstructed and clear camera field of view. Data were stratified by race to evaluate performance differences due to skin tone. RESULTS: All commissioning data were found to meet recommended tolerances. IDENTIFYTM was used to monitor intra-fraction motion on 1164 fractions from 386 patients. The median magnitude of translational SI reported offsets at the end of treatment was 0.27 mm. SI reported offsets were shown to increase when camera pods are blocked by the gantry with larger increases seen at non-zero couch angles. With camera obstruction, the median magnitude of the SI reported offset was 0.50 and 0.80 mm for White and Black patients, respectively. CONCLUSIONS: IDENTIFYTM performance during fSRS is comparable to other commercially available SI systems where offsets are shown to increase at non-zero couch angles and during camera pod blockage.


Subject(s)
Brain Neoplasms , Radiosurgery , Radiotherapy, Intensity-Modulated , Humans , Radiosurgery/methods , Patient Positioning/methods , Particle Accelerators , Phantoms, Imaging , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Brain Neoplasms/radiotherapy
20.
Phys Imaging Radiat Oncol ; 26: 100448, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37252251

ABSTRACT

Background and purpose: Tumor motion and delivery efficiency are two main challenges of lung stereotactic body radiotherapy (SBRT). The present work implemented the deep inspiration breath hold technique (DIBH) with surface guided radiation therapy (SGRT) on closed-bore linacs and investigated the correlation between SGRT data and internal target position. Materials and methods: Thirteen lung SBRT patients treated in DIBH using a closed-bore gantry linac and a ring-mounted SGRT system were retrospectively analysed. Visual coaching was used to achieve DIBH with a ± 1 mm threshold window in the anterior-posterior direction. Three kV-CBCTs were added to the treatment workflow and examined offline to verify intra-fraction tumor position. Surface-based DIBH was analysed using SGRT treatment reports and an in-house python script. Data from 73 treatment sessions and 175 kV-CBCTs were studied. Correlations between target and surface positions were studied with Linear Mixed Models. Results: Median intra-fraction tumor motion was 0.8 mm (range: 0.7-1.3 mm) in the anterior-posterior direction, 1.2 mm (range: 1-1.7 mm) in the superior-inferior direction, and 1 mm (range: 0.7-1.1 mm) in the left-right direction, with rotations of <1° (range: 0.6°-1.1°) degree in all three directions. Planned target volumes and healthy lung volumes receiving 12.5 Gy and 13.5 Gy were reduced on average by 67% and 54%, respectively. Conclusions: Lung SBRT in DIBH with the ring-mounted SGRT system proved reproducible. The surface monitoring provided by SGRT was found to be a reliable surrogate for internal target motion. Moreover, the implementation of DIBH technique helped reduce target volumes and lung doses.