Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 156
Filter
1.
Pediatr Cardiol ; 2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39043954

ABSTRACT

Candidacy for transcatheter pulmonary valve replacement utilizing newer valve platforms is aided by industry-driven fit analyses. We report augmentation of this decision-making process by visualization of 4-dimensional cine imaging of patient-specific right ventricular outflow tract anatomy and a virtual valve model within a virtual reality platform.

2.
Article in English | MEDLINE | ID: mdl-39033329

ABSTRACT

BACKGROUND: Patients with d-transposition of the great arteries (d-TGA) who have undergone an arterial switch operation (ASO) can develop right ventricular outflow tract (RVOT) dysfunction with pulmonary regurgitation (PR) or stenosis. In these patients, treatment may include transcatheter pulmonary valve replacement (TPVR). Coronary compression is a contraindication occurring in 5% of typical TPVR cases. After ASO, there are various anatomical considerations that can confound TPVR, including potential coronary artery compression. Our goal is to understand feasibility of TPVR in patients following ASO. METHODS: This was a retrospective multicenter cohort study of patients with RVOT dysfunction after ASO who underwent cardiac catheterization with intention to perform TPVR from 2008 to 2020. RESULTS: Across nine centers, 33 patients met inclusion criteria. TPVR was successful in 22 patients (66%), 19 receiving a Melody valve and 3 a SAPIEN valve. RVOT stenosis in isolation or with PR dictated need for TPVR in nearly all patients. One serious adverse event occurred with valve embolization. After TPVR, the RVOT peak gradient decreased from 43 to 9 mm Hg (p < 0.001); PR was trivial/none in all but one patient, in whom it was mild. Coronary compression prohibiting TPVR occurred in eight patients (24%) and two patients (6%) had severe aortic regurgitation from aortic root deformation precluding TPVR. Seven patients underwent RVOT reintervention with a median of 5.3 years post-TPVR. CONCLUSIONS: TPVR in patients with d-TGA after ASO is feasible, but in this cohort, coronary compression or aortic root distortion precluded TPVR in one-third of patients. The rate of RVOT reintervention after TPVR was higher in this cohort of ASO patients that in prior studies.

3.
Interv Cardiol Clin ; 13(3): 369-384, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839170

ABSTRACT

Over the last 2 decades, experience with transcatheter pulmonary valve replacement (TPVR) has grown significantly and has become an effective and reliable way of treating pulmonary valve regurgitation, right ventricular outflow (RVOT) obstruction, and dysfunctional bioprosthetic valves and conduits. With the introduction of self-expanding valves and prestents, dilated native RVOT can be addressed with the transcatheter approach. In this article, the authors review the current practices, technical challenges, and outcomes of TPVR.


Subject(s)
Cardiac Catheterization , Heart Defects, Congenital , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Pulmonary Valve/surgery , Heart Defects, Congenital/surgery , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnosis , Ventricular Outflow Obstruction/surgery , Prosthesis Design , Bioprosthesis
4.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38872098

ABSTRACT

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Pulmonary Valve , Recovery of Function , Humans , Male , Child , Female , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Pulmonary Valve/diagnostic imaging , Treatment Outcome , Young Adult , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Time Factors , Adult , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/diagnostic imaging , Bioprosthesis , Pulmonary Valve Stenosis/surgery , Pulmonary Valve Stenosis/physiopathology , Pulmonary Valve Stenosis/diagnostic imaging , Retrospective Studies , Risk Factors , Asia, Southeastern
5.
Front Med Technol ; 6: 1376649, 2024.
Article in English | MEDLINE | ID: mdl-38756328

ABSTRACT

This study aims to evaluate the fluid dynamic characteristics of the VenusP Valve System™ under varying cardiac outputs in vitro. A thorough hemodynamic study of the valve under physiological cardiac conditions was conducted and served as an independent assessment of the performance of the valve. Flow fields downstream of the valve near the pulmonary bifurcation were quantitatively studied by two-dimensional Particle Image Velocimetry (PIV). The obtained flow field was analyzed for potential regions of flow stasis and recirculation, and elevated shear stress and turbulence. High-speed en face imaging capturing the leaflet motion provided data for leaflet kinematic modeling. The experimental conditions for PIV studies were in accordance with ISO 5840-1:2021 standard, and two valves with different lengths and different orientations were studied. Results show good hemodynamics performance for the tested valves according to ISO 5840 standard without significant regions of flow stasis. Observed shear stress values are all well below established hemolysis limits.

7.
J Vet Cardiol ; 53: 52-59, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38688090

ABSTRACT

Transcatheter pulmonary valve implantation (TPVI) is indicated for use in the management of failing pulmonary valves in humans. We report here the long-term follow-up of the first documented transcatheter pulmonary valve implanted in a client-owned dog. A one-year-old Beagle dog with severe congenital type A valvular pulmonic stenosis first underwent percutaneous balloon pulmonary valvuloplasty, leading two years later to severe pulmonary regurgitation. A TPVI using a Melody™ bioprosthetic valve was then successfully performed, with normalization of the right heart cavities. Repeated two- and three-dimensional transthoracic echocardiographic examinations combined with Doppler modes confirmed the appropriate position and function of the valve for four years. Mitral myxomatous valvular degeneration led to refractory left-sided congestive heart failure, and the dog was humanely euthanized. After postmortem examination, X-ray imaging and histopathological evaluation of the stent and the valve were performed. Ex-vivo imaging of the implanted valve using a Faxitron® Path radiography system and microscopic evaluation of the implanted stent and bioprosthetic leaflets did not show any relevant leaflet or stent alterations. This case provides a proof of concept in interventional veterinary cardiology, showing that TPVI can be performed in dogs with subsequent long-term maintaining normal pulmonary valve function.


Subject(s)
Dog Diseases , Heart Valve Prosthesis Implantation , Pulmonary Valve Stenosis , Pulmonary Valve , Animals , Dogs , Dog Diseases/surgery , Dog Diseases/diagnostic imaging , Dog Diseases/pathology , Pulmonary Valve Stenosis/veterinary , Pulmonary Valve Stenosis/diagnostic imaging , Pulmonary Valve Stenosis/surgery , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/pathology , Heart Valve Prosthesis Implantation/veterinary , Heart Valve Prosthesis Implantation/instrumentation , Echocardiography, Three-Dimensional/veterinary , Pulmonary Valve Insufficiency/veterinary , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Echocardiography/veterinary , Bioprosthesis/veterinary , Male , Heart Valve Prosthesis/veterinary , Female
8.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38569760

ABSTRACT

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Adult , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects , Treatment Outcome , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Registries , Prosthesis Design , Retrospective Studies
10.
JACC Clin Electrophysiol ; 10(5): 857-866, 2024 May.
Article in English | MEDLINE | ID: mdl-38456860

ABSTRACT

BACKGROUND: Tetralogy of Fallot (TOF) is associated with risk for sustained monomorphic ventricular tachycardia (VT). Preemptive electrophysiology study before transcatheter pulmonary valve placement is increasing, but the value of MDCT for anatomical VT isthmus assessment is unknown. OBJECTIVES: The purpose of this study was to determine the impact of multidetector computed tomography (MDCT) in the evaluation of sustained monomorphic VT for repaired TOF. METHODS: Consecutive pre-transcatheter pulmonary valve MDCT studies were identified, and anatomical isthmus dimensions were measured. For a subset of patients with preemptive electrophysiology study, MDCT features were compared with electroanatomical maps. RESULTS: A total of 61 repaired TOFs with MDCT were identified (mean 35 ± 14 years, 58% men) with MDCT electroanatomical map pairs in 35 (57%). Calcification corresponding to patch material was present in 46 (75%) and was used to measure anatomical VT isthmuses. MDCT wall thickness correlated positively with number of ablation lesions and varied with functional isthmus properties (blocked isthmus 2.6 mm [Q1, Q3: 2.1, 4.0 mm], slow conduction 4.8 mm [Q1, Q3: 3.3, 6.0 mm], and normal conduction 5.6 mm [Q1, Q3: 3.9, 8.3 mm]; P < 0.001). A large conal branch was present in 6 (10%) and a major coronary anomaly was discovered in 3 (5%). Median ablation lesion distance was closer to the right vs the left coronary artery (10 mm vs 15 mm; P = 0.01) with lesion-to-coronary distance <5 mm in 3 patients. CONCLUSIONS: MDCT identifies anatomical structures relevant to catheter ablation for repaired TOF. Wall thickness at commonly targeted anatomical VT isthmuses is associated with functional isthmus properties and increased thermal energy delivery.


Subject(s)
Multidetector Computed Tomography , Tachycardia, Ventricular , Tetralogy of Fallot , Humans , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Tetralogy of Fallot/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/physiopathology , Male , Female , Adult , Middle Aged , Young Adult , Catheter Ablation
11.
J Am Heart Assoc ; 13(6): e033239, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38456473

ABSTRACT

BACKGROUND: In recent years, self-expanding technology to treat pulmonary regurgitation in the native right ventricular outflow tract became Food and Drug Administration approved in the United States and is now routinely used. The current practice for selection of patients who are candidates for these devices includes screening for "anatomic fit," performed by each of the manufacturing companies. Our study aims to validate the use of virtual reality (VR) as a tool for local physician-led screening of patients. METHODS AND RESULTS: This retrospective study from Children's Hospital Colorado included patients who underwent pulmonary valve replacement and had screening for a Harmony TPV or Alterra Prestent performed between September 2020 and January 2022. The data from the commercial companies' dedicated analysis for self-expanding transcatheter pulmonary valve frames evaluation with perimeter analysis were collected. VR simulation was performed blinded by 2 congenital interventional cardiologists using Elucis VR software and an Oculus Quest 2 headset. Among the 27 evaluated cases, the use of a self-expandable valve was recommended by companies' dedicated analysis in 23 cases (85.2%), by VR assessment in 26 cases (96.3), and finally implanted in 25 cases (92.6%). Regarding the level of agreement, both modalities (manufacturer and VR) were good at screening-in patients who received a self-expanding valve (100% versus 96.1%). When it came to screening-out the patients, VR presented good capacity to accurately classify nonsuitable patients (50% versus 100%). CONCLUSIONS: Our institutional experience with VR transcatheter pulmonary valve implantation planning accurately predicted clinical outcomes. This paves the way for routine use of VR in patient selection for self-expanding valve technologies.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve , Virtual Reality , Child , Humans , United States , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Treatment Outcome , Cardiac Catheterization/methods , Prosthesis Design
12.
Radiol Clin North Am ; 62(3): 419-434, 2024 May.
Article in English | MEDLINE | ID: mdl-38553178

ABSTRACT

The range of potential transcatheter solutions to valve disease is increasing, bringing treatment options to those in whom surgery confers prohibitively high risk. As the range of devices and their indications grow, so too will the demand for procedural planning. Computed tomography will continue to enable this growth through the provision of accurate device sizing and procedural risk assessment.


Subject(s)
Aortic Valve , Tomography, X-Ray Computed , Humans , Aortic Valve/surgery , Tomography, X-Ray Computed/methods , Risk Assessment , Treatment Outcome , Multidetector Computed Tomography/methods
13.
Pediatr Cardiol ; 45(3): 588-590, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38315220

ABSTRACT

In this review, we provide a brief description of recently published articles addressing topics relevant to pediatric cardiologists. Our hope is to provide a summary of the latest articles published recently in other journals in our field. The articles address (1) A new index for prenatal diagnosis of total anomalous pulmonary venous return, (2) Outcomes of patients with Tetralogy of Fallot after pulmonary valve replacement (PVR), and (3) Short-term outcomes of the self expanding Harmony valve for transcatheter PVR.

14.
Echocardiography ; 41(2): e15765, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38341768

ABSTRACT

BACKGROUND: Mixed pulmonary disease with pulmonary regurgitation (PR) and stenosis (PS) in repaired tetralogy of Fallot (rTOF) can negatively impact ventricular health. Myocardial strain has been shown to be more sensitive at detecting occult ventricular dysfunction compared to right ventricular ejection fraction (RV EF). We hypothesize that rTOF patients with predominant PS will have lower RV global longitudinal strain (RV GLS) prior to and post-transcatheter pulmonary valve replacement (TPVR). METHODS: A retrospective cohort of rTOF patients who underwent cardiac magnetic resonance (CMR) and cardiac catheterization for right ventricular pressure (RVSP) measurement were analyzed at three time points: before valve implantation, at discharge and within 18 months post-TPVR. Patients were dichotomized into three groups based on RVSP: 0%-49%, 50%-74%, and >75%. RV GLS and left ventricular (LV) GLS by speckle tracking echocardiography (STE) were obtained from the apical 4-chamber using TomTec software (TOMTEC IS, Germany). RESULTS: Forty-eight patients were included. Every 14.3% increase in preimplantation RVSP above 28% was associated with an absolute magnitude 1% lower RV GLS (p = .001). Preimplantation RVSP when 75% or higher had 3.36% worse RV GLS than the lowest bin (p = .014). Overall, average RV strain magnitude was higher when preimplantation RVSP was less than 50% and had greater improvement over the three time points. Higher post implantation RVSP correlated with lower strain magnitude. CONCLUSION: Patients with significant PS (>50%) may benefit from earlier PVR and not depend solely on RV size and EF. Myocardial strain may be a more sensitive marker of function; however, larger, prospective studies are needed.


Subject(s)
Pulmonary Valve Insufficiency , Pulmonary Valve Stenosis , Pulmonary Valve , Tetralogy of Fallot , Ventricular Dysfunction, Right , Humans , Tetralogy of Fallot/complications , Tetralogy of Fallot/surgery , Global Longitudinal Strain , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Stroke Volume , Retrospective Studies , Ventricular Function, Right , Pulmonary Valve Stenosis/complications , Pulmonary Valve Stenosis/surgery , Pulmonary Valve Insufficiency/complications , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/surgery , Ventricular Dysfunction, Right/complications , Ventricular Dysfunction, Right/diagnostic imaging
15.
Khirurgiia (Mosk) ; (2): 32-44, 2024.
Article in Russian | MEDLINE | ID: mdl-38344958

ABSTRACT

The literature review is devoted to transcatheter pulmonary valve replacement. The authors summarize the indications, clinical data and current capabilities of transcatheter pulmonary valve replacement. The authors also overviewed modern valves for transcatheter pulmonary artery replacement. Effectiveness of transcatheter pulmonary valve implantation has been substantiated. Various studies comparing the outcomes of different valve systems for endovascular implantation were analyzed. The authors concluded the prospects for transcatheter pulmonary valve implantation.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve , Humans , Cardiac Catheterization , Heart Valve Prosthesis Implantation/adverse effects , Prosthesis Design , Pulmonary Valve/surgery , Replantation , Treatment Outcome
16.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Article in English | MEDLINE | ID: mdl-38419402

ABSTRACT

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Subject(s)
Cardiac Surgical Procedures , Pulmonary Valve , Humans , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Treatment Outcome , Asia , Catheters
17.
Catheter Cardiovasc Interv ; 103(4): 612-617, 2024 03.
Article in English | MEDLINE | ID: mdl-38419395

ABSTRACT

While newer self-expanding pulmonic valves were primarily designed for larger right ventricular outflow tracks, there are instances where even larger anatomies cannot accommodate these devices. In this report, we describe the successful implantation of two Harmony™ valves in bilateral branch pulmonary arteries after exhausting other options.


Subject(s)
Heart Valve Prosthesis Implantation , Pulmonary Valve Insufficiency , Humans , Heart Valve Prosthesis Implantation/adverse effects , Pulmonary Artery/diagnostic imaging , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Treatment Outcome , Cardiac Catheterization
18.
Pediatr Cardiol ; 45(3): 570-579, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38296854

ABSTRACT

Transcatheter pulmonary valve implantation (TPVI) is a surgical alternative for correcting dysfunctional right ventricular outflow tract in previously operated patients. MyVal transcatheter heart valve (THV) (Meril Life Sciences, India), a new transcatheter valve designed for aortic position has recently been reported to be implanted in pulmonary position. Myval transcatheter valve were implanted in patients with stenosed dysfunctional conduits, severe regurgitation from transannular patch or dysfunctional surgical pulmonary valves (Bioprosthesis). Procedural details and post-TPVI follow-up were analysed. Myval TPVI was used in Fifty three patients with median age of 15 years (IQR 12-19.5 years). Almost sixty percent of the patients were male, with a median weight of 50 kg (31-63 kg). Prestenting was used in more than 80 percent of patients (n = 45 patients), while 6 patients had a prior surgical valve implantation. After Myval TPVI implantation, the peak instantaneous gradient across the RVOT decreased from a median of 23.5 mmHg (IQR 10-53 mmHg) pre-procedure to 10 mmHg (IQR 5-16 mmHg) post-procedure. The median fluoroscopy time for the procedure was 35 min (IQR 23.5-44 min). The large sizes-mainly the 29-mm and 32 mm Myval (Navigator, Meril Life Sciences Pvt Ltd, India), were the most used size in 40% (n = 22) of the cases each. The median contrast volume used during the procedure was 247 mL (IQR 120-300 mL). Patients were followed for a median period of 360 days (IQR 164-525 days). At the last clinic follow-up, there was no tricuspid valve regurgitation. Moderate neo-pulmonary valve regurgitation was reported in three cases. Early experience of TPVI with MyVal is encouraging with procedural success in all patients and acceptable mid-term outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Male , Child , Adolescent , Young Adult , Adult , Female , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Prosthesis Design , Cardiac Catheterization/methods
20.
Cardiol Young ; 34(4): 865-869, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37921218

ABSTRACT

BACKGROUND AND AIM: Pulmonary regurgitation is the most common complication in repaired tetralogy of Fallot patients. Severe chronic pulmonary regurgitation can be tolerated for decades, but if not treated, it can progress to symptomatic, irreversible right ventricular dilatation and dysfunction. We investigated clinical associations with pulmonary valve replacement among patients with significative pulmonary regurgitation and how interventional developments can change their management. METHODS: All adult patients with repaired tetralogy of Fallot who were followed at an adult CHD Clinic at a single centre from 1980 to 2022 were included on their first outpatient visit. Follow-up was estimated from the time of correction surgery until one of the following events occurred first: pulmonary valve replacement, death, loss to follow-up or conclusion of the study. RESULTS: We included 221 patients (116 males) with a median age of 19 (18-25). At a median age of 33 (10) years old, 114 (51%) patients presented significant pulmonary regurgitation. Among patients with significant pulmonary regurgitation, pulmonary valve replacement was associated with male gender, older age at surgical repair, and longer QRS duration in adulthood. Pulmonary valve replacement was performed in 50 patients, including four transcatheter pulmonary valve implantations, at a median age of 34 (14) years. CONCLUSION: Pulmonary regurgitation affects a large percentage of tetralogy of Fallot adult patients, requiring a long-term clinical and imaging follow-up. Sex, age at surgical repair and longer QRS are associated with the need of PVR among patients with significative pulmonary regurgitation. Clinical practice and current literature support TPVI as the future gold standard intervention.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Pulmonary Valve Insufficiency , Pulmonary Valve , Tetralogy of Fallot , Adult , Humans , Male , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Tetralogy of Fallot/complications , Tetralogy of Fallot/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Surgical Procedures/adverse effects , Treatment Outcome , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL