Eur Radiol ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38987398

ABSTRACT

OBJECTIVES: To investigate the effect of motion-compensated reconstruction (MCR) algorithm on improving the image quality of coronary computed tomography angiography (CCTA) using second-generation dual-layer spectral detector computed tomography (DLCT), and to evaluate the influence of heart rate (HR) on the motion-correction efficacy of this algorithm. MATERIALS AND METHODS: We retrospectively enrolled 127 patients who underwent CCTA for suspected coronary artery disease using second-generation DLCT. We divided the patients into two subgroups according to their average HR during scanning: the "HR < 75 bpm" group and the "HR ≥ 75 bpm" group. All images were reconstructed by the standard (STD) algorithm and MCR algorithm. Subjective image quality (4-point Likert scale), interpretability, and objective image quality between the STD and MCR in the whole population and within each subgroup were compared. RESULTS: MCR showed significantly higher Likert scores and interpretability than STD on the per-segment (3.58 ± 0.69 vs. 2.82 ± 0.93, 98.4% vs. 91.9%), per-vessel (3.12 ± 0.81 vs. 2.12 ± 0.74, 96.3% vs. 78.7%) and per-patient (2.57 ± 0.76 vs. 1.62 ± 0.55, 90.6% vs. 59.1%) levels (all p < 0.001). In the analysis of HR subgroups on a per-vessel basis of interpretability, significant differences were observed only in the right coronary artery in the low HR group, whereas significant differences were noted in three major coronary arteries in the high HR group. For objective image quality assessment, MCR significantly improved the SNR (13.22 ± 4.06 vs. 12.72 ± 4.06) and the contrast-to-noise ratio (15.84 ± 4.82 vs. 15.39 ± 4.38) compared to STD (both p < 0.001). CONCLUSION: MCR significantly improves the subjective image quality, interpretability, and objective image quality of CCTA, especially in patients with higher HRs. CLINICAL RELEVANCE STATEMENT: The motion-compensated reconstruction algorithm of the second-generation dual-layer spectral detector computed tomography is helpful in improving the image quality of coronary computed tomography angiography in clinical practice, especially in patients with higher heart rates. KEY POINTS: Motion artifacts from cardiac movement affect the quality and interpretability of coronary computed tomography angiography (CCTA). This motion-compensated reconstruction (MCR) algorithm significantly improves the image quality of CCTA in clinical practice. Image quality improvement by using MCR was more significant in the high heart rate group.

2.
BMC Med Imaging ; 24(1): 162, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38956470

ABSTRACT

BACKGROUND: The image quality of computed tomography angiography (CTA) images following endovascular aneurysm repair (EVAR) is not satisfactory, since artifacts resulting from metallic implants obstruct the clear depiction of stent and isolation lumens, and also adjacent soft tissues. However, current techniques to reduce these artifacts still need further advancements due to higher radiation doses, longer processing times and so on. Thus, the aim of this study is to assess the impact of utilizing Single-Energy Metal Artifact Reduction (SEMAR) alongside a novel deep learning image reconstruction technique, known as the Advanced Intelligent Clear-IQ Engine (AiCE), on image quality of CTA follow-ups conducted after EVAR. MATERIALS: This retrospective study included 47 patients (mean age ± standard deviation: 68.6 ± 7.8 years; 37 males) who underwent CTA examinations following EVAR. Images were reconstructed using four different methods: hybrid iterative reconstruction (HIR), AiCE, the combination of HIR and SEMAR (HIR + SEMAR), and the combination of AiCE and SEMAR (AiCE + SEMAR). Two radiologists, blinded to the reconstruction techniques, independently evaluated the images. Quantitative assessments included measurements of image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the longest length of artifacts (AL), and artifact index (AI). These parameters were subsequently compared across different reconstruction methods. RESULTS: The subjective results indicated that AiCE + SEMAR performed the best in terms of image quality. The mean image noise intensity was significantly lower in the AiCE + SEMAR group (25.35 ± 6.51 HU) than in the HIR (47.77 ± 8.76 HU), AiCE (42.93 ± 10.61 HU), and HIR + SEMAR (30.34 ± 4.87 HU) groups (p < 0.001). Additionally, AiCE + SEMAR exhibited the highest SNRs and CNRs, as well as the lowest AIs and ALs. Importantly, endoleaks and thrombi were most clearly visualized using AiCE + SEMAR. CONCLUSIONS: In comparison to other reconstruction methods, the combination of AiCE + SEMAR demonstrates superior image quality, thereby enhancing the detection capabilities and diagnostic confidence of potential complications such as early minor endleaks and thrombi following EVAR. This improvement in image quality could lead to more accurate diagnoses and better patient outcomes.


Subject(s)
Artifacts , Computed Tomography Angiography , Endovascular Procedures , Humans , Retrospective Studies , Female , Computed Tomography Angiography/methods , Aged , Male , Endovascular Procedures/methods , Middle Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Deep Learning , Radiographic Image Interpretation, Computer-Assisted/methods , Stents , Endovascular Aneurysm Repair
3.
Magn Reson Med ; 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38968132

ABSTRACT

PURPOSE: To reduce the ringing artifacts of the motion-resolved images in free-breathing dynamic pulmonary MRI. METHODS: A golden-step based interleaving (GSI) technique was proposed to reduce ringing artifacts induced by diaphragm drifting. The pulmonary MRI data were acquired using a superior-inferior navigated 3D radial UTE sequence in an interleaved manner during free breathing. Successive interleaves were acquired in an incoherent fashion along the polar direction. Four-dimensional images were reconstructed from the motion-resolved k-space data obtained by retrospectively binning. The reconstruction algorithms included standard nonuniform fast Fourier transform (NUFFT), Voronoi-density-compensated NUFFT, extra-dimensional UTE, and motion-state weighted motion-compensation reconstruction. The proposed interleaving technique was compared with a conventional sequential interleaving (SeqI) technique on a phantom and eight subjects. RESULTS: The quantified ringing artifacts level in the motion-resolved image is positively correlated with the quantified nonuniformity level of the corresponding k-space. The nonuniformity levels of the end-expiratory and end-inspiratory k-space binned from GSI data (0.34 ± 0.07, 0.33 ± 0.05) are significantly lower with statistical significance (p < 0.05) than that binned from SeqI data (0.44 ± 0.11, 0.42 ± 0.12). Ringing artifacts are substantially reduced in the dynamic images of eight subjects acquired using the proposed technique in comparison with that acquired using the conventional SeqI technique. CONCLUSION: Ringing artifacts in the motion-resolved images induced by diaphragm drifting can be reduced using the proposed GSI technique for free-breathing dynamic pulmonary MRI. This technique has the potential to reduce ringing artifacts in free-breathing liver and kidney MRI based on full-echo interleaved 3D radial acquisition.

4.
Imaging Sci Dent ; 54(2): 139-145, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38948185

ABSTRACT

Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

5.
Imaging Sci Dent ; 54(2): 191-199, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38948193

ABSTRACT

Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test (α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

6.
J Biophotonics ; : e202400104, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38955360

ABSTRACT

A number of hardware-based and software-based strategies have been suggested to eliminate motion artifacts for improvement of 3D-optical coherence tomography (OCT) image quality. However, the hardware-based strategies have to employ additional hardware to record motion compensation information. Many software-based strategies have to need additional scanning for motion correction at the expense of longer acquisition time. To address this issue, we propose a motion artifacts correction and motion estimation method for OCT volumetric imaging of anterior segment, without requirements of additional hardware and redundant scanning. The motion correction effect with subpixel accuracy for in vivo 3D-OCT has been demonstrated in experiments. Moreover, the physiological information of imaging object, including respiratory curve and respiratory rate, has been experimentally extracted using the proposed method. The proposed method offers a powerful tool for scientific research and clinical diagnosis in ophthalmology and may be further extended for other biomedical volumetric imaging applications.

7.
Pflugers Arch ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38955833

ABSTRACT

Cellular responses to hypoxia are crucial in various physiological and pathophysiological contexts and have thus been extensively studied. This has led to a comprehensive understanding of the transcriptional response to hypoxia, which is regulated by hypoxia-inducible factors (HIFs). However, the detailed molecular mechanisms of HIF regulation in hypoxia remain incompletely understood. In particular, there is controversy surrounding the production of mitochondrial reactive oxygen species (ROS) in hypoxia and how this affects the stabilization and activity of HIFs. This review examines this controversy and attempts to shed light on its origin. We discuss the role of physioxia versus normoxia as baseline conditions that can affect the subsequent cellular response to hypoxia and highlight the paucity of data on pericellular oxygen levels in most experiments, leading to variable levels of hypoxia that might progress to anoxia over time. We analyze the different outcomes reported in isolated mitochondria, versus intact cells or whole organisms, and evaluate the reliability of various ROS-detecting tools. Finally, we examine the cell-type and context specificity of oxygen's various effects. We conclude that while recent evidence suggests that the effect of hypoxia on ROS production is highly dependent on the cell type and the duration of exposure, efforts should be made to conduct experiments under carefully controlled, physiological microenvironmental conditions in order to rule out potential artifacts and improve reproducibility in research.

8.
Abdom Radiol (NY) ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980403

ABSTRACT

OBJECTIVES: To compare the image quality of 1.5T and 3T prostate MRIs of the same post-hip arthroplasty patients, with a specific focus on the degree of susceptibility artifacts. METHODS: This single-center retrospective study included post-hip arthroplasty patients who underwent 1.5T prostate MRIs between 2021 and 2023, as well as comparative 3T prostate MRIs. Three blinded abdominal radiologists retrospectively reviewed their diffusion-weighted imaging (DWI, 50 s/mm2), T2-weighted imaging (T2WI), and dynamic contrast-enhanced imaging (DCE) to evaluate the image quality. The degree of susceptibility artifacts was categorized using a three-point scale, with 3 indicating the least artifact and 1 indicating the most. Image quality was also evaluated using Prostate Imaging Quality (PI-QUAL) version 2. The median of the three raters' scores was compared between 1.5T and 3T prostate MRIs using the Wilcoxon signed-rank test. The inter-rater agreement was evaluated using the multi-rater generalized kappa. RESULTS: Twenty pairs of 1.5T and 3T prostate MRI examinations from 20 unique patients were included. The DWI susceptibility artifact score at 1.5T was significantly higher than at 3T (mean score ± standard deviation, 2.80 ± 0.41 vs. 2.35 ± 0.93, p = 0.014). In contrast, no significant differences were observed in the susceptibility artifact scores in T2WI and DCE, or in the PI-QUAL score. The inter-reader agreement in the susceptibility artifact score was moderate (multi-rater generalized kappa: 0.60) in DWI, perfect in T2WI (not applicable), and substantial (0.65) in DCE. The inter-reader agreement was fair (0.27) in the PI-QUAL score. CONCLUSION: Using 1.5T scanners may be preferable to reduce susceptibility artifacts from hip prostheses in DWI.

9.
Mitochondrial DNA B Resour ; 9(7): 861-864, 2024.
Article in English | MEDLINE | ID: mdl-38983844

ABSTRACT

The complete mitochondrial genome of Blue-fronted Redstart (Phoenicurus frontalis), GenBank accession number MT360379 (NC_053917), was published by Li and colleages in 2020. Here we show that this mitogenome is actually a chimera containing DNA fragments of both P. frontalis (15,518 bp, 92.5%) and Pink-rumped Rosefinch (Carpodacus waltoni eos, 1258 bp, 7.5%). This mitogenome has been re-used in at least three phylogenies. Our study confirms that mitogenomes are best verified with multiple gene trees, and that any anomalies should be investigated by direct comparison of sequences.

10.
Front Neuroimaging ; 3: 1336887, 2024.
Article in English | MEDLINE | ID: mdl-38984197

ABSTRACT

Introduction: Use of functional MRI in awake non-human primate (NHPs) has recently increased. Scanning animals while awake makes data collection possible in the absence of anesthetic modulation and with an extended range of possible experimental designs. Robust awake NHP imaging however is challenging due to the strong artifacts caused by time-varying off-resonance changes introduced by the animal's body motion. In this study, we sought to thoroughly investigate the effect of a newly proposed dynamic off-resonance correction method on brain activation estimates using extended awake NHP data. Methods: We correct for dynamic B0 changes in reconstruction of highly accelerated simultaneous multi-slice EPI acquisitions by estimating and correcting for dynamic field perturbations. Functional MRI data were collected in four male rhesus monkeys performing a decision-making task in the scanner, and analyses of improvements in sensitivity and reliability were performed compared to conventional image reconstruction. Results: Applying the correction resulted in reduced bias and improved temporal stability in the reconstructed time-series data. We found increased sensitivity to functional activation at the individual and group levels, as well as improved reliability of statistical parameter estimates. Conclusions: Our results show significant improvements in image fidelity using our proposed correction strategy, as well as greatly enhanced and more reliable activation estimates in GLM analyses.

11.
Phys Med Biol ; 69(14)2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38959913

ABSTRACT

Objective. Follow-up computed tomography angiography (CTA) is necessary for ensuring occlusion effect of endovascular coiling. However, the implanted metal coil will introduce artifacts that have a negative spillover into radiologic assessment.Method. A framework named ReMAR is proposed in this paper for metal artifacts reduction (MARs) from follow-up CTA of patients with coiled aneurysms. It employs preoperative CTA to provide the prior knowledge of the aneurysm and the expected position of the coil as a guidance thus balances the metal artifacts removal performance and clinical feasibility. The ReMAR is composed of three modules: segmentation, registration and MAR module. The segmentation and registration modules obtain the metal coil knowledge via implementing aneurysms delineation on preoperative CTA and alignment of follow-up CTA. The MAR module consisting of hybrid convolutional neural network- and transformer- architectures is utilized to restore sinogram and remove the artifact from reconstructed image. Both image quality and vessel rendering effect after metal artifacts removal are assessed in order to responding clinical concerns.Main results. A total of 137 patients undergone endovascular coiling have been enrolled in the study: 13 of them have complete diagnosis/follow-up records for end-to-end validation, while the rest lacked of follow-up records are used for model training. Quantitative metrics show ReMAR significantly reduced the metal-artifact burden in follow-up CTA. Qualitative ranks show ReMAR could preserve the morphology of blood vessels during artifact removal as desired by doctors.Significance. The ReMAR could significantly remove the artifacts caused by implanted metal coil in the follow-up CTA. It can be used to enhance the overall image quality and convince CTA an alternative to invasive follow-up in treated intracranial aneurysm.


Subject(s)
Artifacts , Computed Tomography Angiography , Endovascular Procedures , Metals , Humans , Endovascular Procedures/instrumentation , Image Processing, Computer-Assisted/methods , Follow-Up Studies , Female
12.
Int J Neural Syst ; : 2450052, 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38989919

ABSTRACT

Quality assessment (QA) of magnetic resonance imaging (MRI) encompasses several factors such as noise, contrast, homogeneity, and imaging artifacts. Quality evaluation is often not standardized and relies on the expertise, and vigilance of the personnel, posing limitations especially with large datasets. Machine learning based on convolutional neural networks (CNNs) is a promising approach to address these challenges by performing automated inspection of MR images. In this study, a CNN for the detection of random head motion artifacts (RHM) in T1-weighted MRI as one aspect of image quality is proposed. A two-step approach aimed to first identify images exhibiting pronounced motion artifacts, and second to evaluate the feasibility of a more detailed three-class classification. The utilized dataset consisted of 420 T1-weighted whole-brain image volumes with isotropic resolution. Human experts assigned each volume to one of three classes of artifact prominence. Results demonstrate an accuracy of 95% for the identification of images with pronounced artifact load. The addition of an intermediate class retained an accuracy of 76%. The findings highlight the potential of CNN-based approaches to increase the efficiency of post-hoc QAs in large datasets by flagging images with potentially relevant artifact loads for closer inspection.

13.
Indian J Nucl Med ; 39(2): 139-141, 2024.
Article in English | MEDLINE | ID: mdl-38989303

ABSTRACT

Comprehension of the typical distribution pattern of 99mTc-methylenediphosphonate (MDP) is crucial for precise interpretation of bone scintigraphy. The presence of nonskeletal activity is predominantly confined to the kidneys and bladder, attributed to the standard renal excretion of 99mTc-MDP. We discuss a 70-year-old woman with a known case of brucellosis using rifampin, doxycycline, trimethoprim/sulfamethoxazole (co-trimoxazole), and ciprofloxacin for the past 8 months. Anterior and posterior aspects of the whole-body bone scan showed diffuse increased uptake in the bodies of L2 and L3 vertebrae and related intervertebral disks. However, unexpected uptake is noted in the right upper quadrant in the region of the gallbladder. Radiochemical impurities did not show during radiopharmaceutical (MDP) quality control, and the other patients showed normal distribution. This gallbladder uptake may be attributed to the altered distribution of the radiotracer and/or gallbladder injury caused by the administration of antibiotic therapy.

14.
J Belg Soc Radiol ; 108(1): 68, 2024.
Article in English | MEDLINE | ID: mdl-38974910

ABSTRACT

Teaching point: To emphasize the importance of recognizing mirror image artifacts in musculoskeletal ultrasound to avoid misdiagnosis, unnecessary interventions, and additional diagnostic procedures that can lead to patient anxiety, increased healthcare costs, and potential harm.

15.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(5): 950-959, 2024 May 20.
Article in Chinese | MEDLINE | ID: mdl-38862453

ABSTRACT

OBJECTIVE: To propose a CT truncated data reconstruction model (DDTrans) based on projection and image dualdomain Transformer coupled feature learning for reducing truncation artifacts and image structure distortion caused by insufficient field of view (FOV) in CT scanning. METHODS: Transformer was adopted to build projection domain and image domain restoration models, and the long-range dependency modeling capability of the Transformer attention module was used to capture global structural features to restore the projection data information and enhance the reconstructed images. We constructed a differentiable Radon back-projection operator layer between the projection domain and image domain networks to enable end-to-end training of DDTrans. Projection consistency loss was introduced to constrain the image forwardprojection results to further improve the accuracy of image reconstruction. RESULTS: The experimental results with Mayo simulation data showed that for both partial truncation and interior scanning data, the proposed DDTrans method showed better performance than the comparison algorithms in removing truncation artifacts at the edges and restoring the external information of the FOV. CONCLUSION: The DDTrans method can effectively remove CT truncation artifacts to ensure accurate reconstruction of the data within the FOV and achieve approximate reconstruction of data outside the FOV.


Subject(s)
Algorithms , Artifacts , Image Processing, Computer-Assisted , Tomography, X-Ray Computed , Tomography, X-Ray Computed/methods , Image Processing, Computer-Assisted/methods , Humans , Phantoms, Imaging
16.
J Xray Sci Technol ; 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38875073

ABSTRACT

BACKGROUND: The polychromatic X-rays generated by a linear accelerator (Linac) often result in noticeable hardening artifacts in images, posing a significant challenge to accurate defect identification. To address this issue, a simple yet effective approach is to introduce filters at the radiation source outlet. However, current methods are often empirical, lacking scientifically sound metrics. OBJECTIVE: This study introduces an innovative filter design method that optimizes filter performance by balancing the impact of ray intensity and energy on image quality. MATERIALS AND METHODS: Firstly, different spectra under various materials and thicknesses of filters were obtained using GEometry ANd Tracking (Geant4) simulation. Subsequently, these spectra and their corresponding incident photon counts were used as input sources to generate different reconstructed images. By comprehensively comparing the intensity differences and noise in images of defective and non-defective regions, along with considering hardening indicators, the optimal filter was determined. RESULTS: The optimized filter was applied to a Linac-based X-ray computed tomography (CT) detection system designed for identifying defects in graphite materials within high-temperature gas-cooled reactor (HTR), with defect dimensions of 2 mm. After adding the filter, the hardening effect reduced by 22%, and the Defect Contrast Index (DCI) reached 3.226. CONCLUSION: The filter designed based on the parameters of Average Difference (AD) and Defect Contrast Index (DCI) can effectively improve the quality of defect images.

17.
Med Phys ; 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38873959

ABSTRACT

BACKGROUND: The beam-hardening effect due to the polychromatic nature of the X-ray spectra results in two main artifacts in CT images: cupping in homogeneous areas and dark bands between dense parts in heterogeneous samples. Post-processing methods have been proposed in the literature to compensate for these artifacts, but these methods may introduce additional noise in low-dose acquisitions. Iterative methods are an alternative to compensate noise and beam-hardening artifacts simultaneously. However, they usually rely on the knowledge of the spectrum or the selection of empirical parameters. PURPOSE: We propose an iterative reconstruction method with beam hardening compensation for small animal scanners that is robust against low-dose acquisitions and that does not require knowledge of the spectrum, overcoming the limitations of current beam-hardening correction algorithms. METHODS: The proposed method includes an empirical characterization of the beam-hardening function based on a simple phantom in a polychromatic statistical reconstruction method. Evaluation was carried out on simulated data with different noise levels and step angles and on limited-view rodent data acquired with the ARGUS/CT system. RESULTS: Results in small animal studies showed a proper correction of the beam-hardening artifacts in the whole sample, independently of the quantity of bone present on each slice. The proposed approach also reduced noise in the low-dose acquisitions and reduced streaks in the limited-view acquisitions. CONCLUSIONS: Using an empirical model for the beam-hardening effect, obtained through calibration, in an iterative reconstruction method enables a robust correction of beam-hardening artifacts in low-dose small animal studies independently of the bone distribution.

18.
Spectrochim Acta A Mol Biomol Spectrosc ; 319: 124381, 2024 Oct 15.
Article in English | MEDLINE | ID: mdl-38838602

ABSTRACT

Adenosine is one of the building blocks of nucleic acids and other biologically important molecules. Spectroscopic methods have been among the most utilized techniques to study adenosine and its derivatives. However, most of them deal with adenosine in solution. Here, we present the first vibrational circular dichroism (VCD) spectroscopic study of adenosine crystals in solid state. Highly regular arrangement of adenosine molecules in a crystal resulted in a strongly enhanced supramolecular VCD signal originating from long-range coupling of vibrations. The data suggested that adenosine crystals, in contrast to guanosine ones, do not imbibe atmospheric water. Relatively large dimensions of the adenosine crystals resulted in scattering and substantial orientational artifacts affecting the spectra. Several strategies for tackling the artifacts have been proposed and tested. Atypical features in IR absorption spectra of crystalline adenosine (e.g., extremely low absorption in mid-IR spectral range) were observed and attributed to refractive properties of adenosine crystals.

19.
Magn Reson Med ; 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38923628

ABSTRACT

PURPOSE: Non-contrast-enhanced time of flight (TOF) is a standard method for magnetic resonance angiography used to depict vessel morphology. TOF is commonly performed with a 3D steady-state acquisition, employing a short repetition time to support high resolution imaging. At 7 T, TOF exhibits substantial increase in SNR and contrast, improving its clinical value. However, one of the remaining challenges, exacerbated at 7 T, is the presence of artifacts due to pulsatile blood flow, especially near major blood vessels. In this study we examine a method to significantly reduce these artifacts. METHODS: We recently introduced a new "local-scrambling" approach that semi-randomizes the acquisition order of the phase encodes, to achieve a controllable cutoff frequency above which the artifacts are drastically reduced. With this approach, artifacts resulting from fast local fluctuations such as cardiac pulsation are significantly reduced. In this study, we explore the ability of this local-scrambling approach to reduce pulsatile blood flow artifacts in a 3D TOF acquisition. Cartesian line-by-line and center-out ordering, with and without local-scrambling, were compared in simulations and in human brain imaging at 3 and 7 T scanners. RESULTS: In the simulations the artifact intensity showed a 10-fold reduction using local-scrambling compared to line-by-line and 4-fold compared to center-out ordering. In vivo results show that artifacts are much more pronounced at 7 T compared to 3 T, and in both cases they are effectively reduced by local-scrambling. CONCLUSION: Local-scrambling improves image quality for both line-by-line and center-out ordering. This approach can easily be implemented in the scanner without any changes to the reconstruction.

20.
J Appl Clin Med Phys ; : e14453, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38923797

ABSTRACT

BACKGROUND: Objective assessment of metal artifact strength and the effectiveness of metal artifact reduction algorithms in computed tomography requires a quantitative metric. Metrics described in the literature are typically employed to compare the artifact strength in images reconstructed from the same raw data, but their robustness against varying scan conditions and repeated scans over time as it occurs in periodic quality assurance has not been investigated. PURPOSE: A new robust metric for quantifying metal artifacts in computed-tomography images is proposed and compared to other commonly used metrics. METHODS: The proposed artifact metric is based on the location parameter of the Gumbel distribution, described previously in the literature, but normalized to the location parameter in a background region-of-interest to obtain a noise-independent artifact metric. The metric was compared to three other quantitative metal artifact metrics (artifact-index, contrast-to-noise ratio, Gumbel-evaluation method) by evaluating metals artifacts in phantom scans and in clinical images. Robustness of the artifact metrics was evaluated using repeated scans with varying noise and against small variations in the selected regions-of-interest. RESULTS: The proposed artifact metric was independent of the underlying image noise and could be reproduced more consistently under slight changes of the region-of-interest within the artifact than the other investigated methods. The coefficient-of-variation was 5.7% on average with varying regions-of-interest in phantom scans and 2.5% in patient scans compared to 9.2% in phantoms scans and 9.9% in patient scans for the next-best performing noise-independent metric. Setup reproducibility was better than 5% and was comparable to the other metrics. The new metric correlated linearly with the artifact strength. The contrast-to-noise ratio, although often used in artifact quantification, was found to be an inadequate metric due to its lack of robustness against minute changes in the position, size, and pixel values of the region-of-interest chosen for calculating the metric and because it showed no correlation with the artifact strength. CONCLUSIONS: A new metal artifact metric has been proposed that is robust under changing scan conditions and less sensitive to user-dependent choices of the region-of-interest than other metrics. The new metric is straightforward to calculate and simple to implement in software commonly used for evaluation of medical imaging systems.