Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Publication year range
1.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(1): 18-24, Jan.-Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-973865

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of accelerated corneal crosslinking on corneal biomechanics with an ocular response analyzer in patients with progressive keratoconus. Methods: In this retrospective study, 50 eyes of 45 patients with progressive keratoconus who underwent accelerated corneal crosslinking were evaluated with ocular response analyzer waveform parameters before and one year after corneal crosslinking. Paired two-tailed Student's t-test was performed to compare the parameters before vs. after corneal crosslinking. Results: Mean patient age was 17.6 ± 3.6 (range 9-25) years. A significant increase was observed in p1 area, p2 area, h2, and dive2 values. No significant difference in corneal hysteresis, corneal resistance factor, or other waveform-derived parameters was observed at one year postoperatively. Conclusion: For estimating the effect of accelerated corneal crosslinking on corneal biomechanics, parameters such as p1 area, p2 area, h2, and dive2 are more sensitive than corneal hysteresis and corneal resistance factor. These results may help us to find out which corneal crosslinking method is most effective for stiffening the cornea.


RESUMO Objetivo: Avaliar o efeito do cross-linking corneano acelerado na biomecânica corneana com analisador de resposta ocular em pacientes com ceratocone progressivo. Métodos: Neste estudo retrospectivo, 50 olhos de 45 pacientes com ceratocone progressivo submetidos à cross-linking corneano acelerado foram avaliados com os parâmetros da forma de onda do analisador de resposta ocular antes e um ano após o tratamento com cross-linking corneano. O teste t de Student pareado bicaudal foi realizado para comparar os parâmetros antes e depois do cross-linking corneano. Resultados: A média de idade dos pacientes foi de 17,6 ± 3,6 (variação de 9 a 25) anos. Um aumento significativo foi observado nos valores de p1area, p2area, h2 e dive2. Nenhuma diferença significativa foi encontrada na histerese da córnea, fator de resistência da córnea ou outros parâmetros derivados da forma de onda foi observada em um ano de pós-operatório. Conclusão: Para estimar o efeito do cross-linking corneano acelerado na biomecânica corneana, parâmentros como p1area, p2area, h2 e dive2 são mais sensíveis que histerese da córnea e fator de resistência corneana. Esses resultados podem nos ajudar a descobrir qual método cross-linking corneano é mais eficaz no enrijecimento da córnea.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Keratoconus/surgery , Keratoconus/pathology , Reference Values , Riboflavin/therapeutic use , Vitamin B Complex/therapeutic use , Biomechanical Phenomena , Visual Acuity , Linear Models , Reproducibility of Results , Retrospective Studies , Treatment Outcome , Cornea/surgery , Cornea/pathology , Corneal Topography/instrumentation , Cross-Linking Reagents/therapeutic use , Corneal Pachymetry/methods , Keratoconus/physiopathology
2.
Rev. cuba. oftalmol ; 30(3): 1-11, jul.-set. 2017. ilus
Article in Spanish | LILACS | ID: biblio-901385

ABSTRACT

Este trabajo tiene como objetivo conocer los avances más novedosos relacionados con el estudio de las características biomecánicas de la córnea y su posible relación en el diagnóstico del glaucoma. Se realizó una búsqueda en la plataforma Infomed, específicamente en la Biblioteca Virtual de Salud, con el objetivo de conocer los avances más novedosos relacionados con el estudio de las características biomecánicas de la córnea y su posible relación en el diagnóstico del glaucoma. La biomecánica corneal es la facultad de resistencia y flexión simultánea de las moléculas de colágeno en las diferentes capas de la córnea. Trata del equilibrio y de la deformación del tejido corneal sometido a cualquier acción exterior. La histéresis corneal, junto con el factor de resistencia corneal, son medidas que pueden ser proporcionadas por el analizador de respuesta ocular. La existencia de un bajo valor de estas dos medidas pudiera considerarse como un factor de riesgo de progresión en el glaucoma(AU)


The purpose of this work is to know the more novel advances related with the study of the biomechanic characteristic of the cornea and its possible relationship in the diagnosis of the glaucoma. A search was made in Infomed platform, particularly in the Virtual Library of Health, to find out the most advanced in the study of the corneal biomechanical properties and its possible relation with the diagnose of glaucoma. Corneal biomechanical is the power of the resistance and flexion simultaneity of collagen molecules of the different corneal layer. It is the balance and deformity of the corneal tissue submitted to an external action. Corneal hysteresis and corneal resistance factor are two corneal biomechanical properties measured by the Ocular Response Analyzer. The existence of a low value of these two properties may be considered as progression factors in glaucoma(AU)


Subject(s)
Humans , Cornea/physiopathology , Glaucoma/diagnosis , Review Literature as Topic , Technological Development/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL