Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(16)2023 Aug 13.
Article in English | MEDLINE | ID: mdl-37631683

ABSTRACT

Photovoltaic (PV) systems are crucial to the production of electricity for a newly established community in Egypt, especially in grid-tied systems. Power quality (PQ) issues appear as a result of PV connection with the power grid (PG). PQ problems cause the PG to experience faults and harmonics, which affect consumers. A series compensator dynamic voltage restorer (DVR) is the most affordable option for resolving the abovementioned PQ problems. To address PQ difficulties, this paper describes a grid-tied PV combined with a DVR that uses a rotating dq reference frame (dqRF) controller. The main goal of this study is to apply and construct an effective PI controller for a DVR to mitigate PQ problems. The artificial rabbits optimization (ARO) is used to obtain the best tune of the PI controller. The obtained results are compared with five optimization techniques (L-SHADE, CMAES, WOA, PSO, and GWO) to show its impact and effectiveness. Additionally, Lyapunov's function is used to analyze and evaluate the proposed controller stability. Also, a mathematical analysis of the investigated PV, boost converter, and rotating dqRF control is performed. Two fault test scenarios are examined to confirm the efficacy of the suggested control approach. The parameters' (voltage, current, and power) waveforms for the suggested system are improved, and the system is kept running continuously under fault periods, which improves the performance of the system. Moreover, the findings demonstrate that the presented design successfully keeps the voltage at the required level with low THD% values at the load side according to the IEEE standards and displays a clear enhancement in voltage waveforms. The MATLAB/SIMULINK software is used to confirm the proposed system's performance.

2.
ISA Trans ; 121: 316-326, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33888296

ABSTRACT

With the advancement of technology, electric equipment and loads have become more sensitive to problems related to power quality, such as voltage sag, swell, imbalances, and harmonics. To detect faults and to protect sensitive loads from these voltage distortions, a Dynamic Voltage Restorer (DVR) series compensator is among the best available cost-effective solutions. One of the main goals of the DVR is to achieve a control structure that is robust, stable, and can handle properly the disturbances (e.g., grid voltage issues, load current, and fluctuations at the DC link voltage) and model uncertainties (e.g., inverters and filter parameters). In this work, a novel framework control strategy based on Uncertainty and Disturbance Estimator (UDE) is proposed to improve the response of the DVR to properly compensate the load voltage under a variety of power quality issues, particularly the ones associated with the grid voltage disturbances. Additionally, the stability of the proposed control system is analyzed and validated using the Lyapunov stability theory. The advantages of the new control system are robustness, simplified design, good harmonic rejection, low tracking error, fast response, and sinusoidal reference tracking without the need for voltage transformations or specific frequency tuning (e.g., abc-dq0 and Proportional-Resonant). This research uses the MATLAB/Simulink software to validate the effectiveness of the proposed scheme under a diverse set of conditions with no control limitations. Moreover, the designed controller is tested under real conditions using Hardware-In-the-Loop (HIL) validation with OPAL-RT real-time simulator coupled with a TI Launchpad microcontroller. The results demonstrate a good performance of the proposed control strategy for a quick transient response and a great harmonic rejection when subject to grid voltage distortions.

3.
Sensors (Basel) ; 21(5)2021 Feb 25.
Article in English | MEDLINE | ID: mdl-33668960

ABSTRACT

In this paper, an incorporated bridge-type superconducting fault current limiter (BSFCL) and Dynamic Voltage Restorer (DVR) is presented to improve the voltage quality and limiting fault current problems in distribution systems. In order to achieve these capabilities, the BSFCL and DVR are integrated through a common DC link as a BSFCL-DVR system. The FCL and DVR ports of the BSFCL-DVR system are located in the beginning and end of the sensitive loads' feeder integrated to the point of common coupling (PCC) in the distribution system. At first, the principle operation of the BSFCL-DVR is discussed. Then, a control system for the BSFCL-DVR system is designed to enhance the voltage quality and limit the fault current. Eventually, the efficiency of the BSFCL-DVR system is verified through the PSCAD/EMTDC simulation.

4.
ISA Trans ; 95: 110-129, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31103256

ABSTRACT

This paper presents a novel contribution of a low complexity control scheme for voltage control of a dynamic voltage restorer (DVR). The scheme proposed utilizes an error-driven proportional-integral-derivative (PID) controller to guarantee better power quality performance in terms of voltage enhancement and stabilization of the buses, energy efficient utilization, and harmonic distortion reduction in a distribution network. This method maintains the load voltage close to or equal to the nominal value in terms of various voltage disturbances such as balanced and unbalanced sag/swell, voltage imbalance, notching, different fault conditions as well as power system harmonic distortion. A grasshopper optimization algorithm (GOA) is used to tune the gain values of the PID controller. In order to validate the effectiveness of the proposed DVR controller, first, a fractional order PID controller was presented and compared with the proposed one. Further, a comparative performance evaluation of four optimization techniques, namely Cuckoo search (CSA), GOA, Flower pollination (FBA), and Grey wolf optimizer (GWO), is presented to compare between the PID and FOPID performance in terms of fault conditions in order to achieve a global minimum error and fast dynamic response of the proposed controller. Second, a comparative analysis of simulation results obtained using the proposed controller and those obtained using an active disturbance rejection controller (ADRC) is presented, and it was found that the performance of the optimal PID is better than the performance of the conventional ADRC. Finally, the effectiveness of the presented DVR with the controller proposed has been assessed by time-domain simulations in the MATLAB/Simulink platform.

5.
ISA Trans ; 70: 465-474, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28689698

ABSTRACT

Fault ride through (FRT) capability in wind turbines to maintain the grid stability during faults has become mandatory with the increasing grid penetration of wind energy. Doubly fed induction generator based wind turbine (DFIG-WT) is the most popularly utilized type of generator but highly susceptible to the voltage disturbances in grid. Dynamic voltage restorer (DVR) based external FRT capability improvement is considered. Since DVR is capable of providing fast voltage sag mitigation during faults and can maintain the nominal operating conditions for DFIG-WT. The effectiveness of the DVR using Synchronous reference frame (SRF) control is investigated for FRT capability in DFIG-WT during both balanced and unbalanced fault conditions. The operation of DVR is confirmed using time-domain simulation in MATLAB/Simulink using 1.5MW DFIG-WT.

SELECTION OF CITATIONS