Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33.995
Filter
1.
Article in English | MEDLINE | ID: mdl-38725875

ABSTRACT

Accurate measurement of the size of lesions or distances between any two points during endoscopic examination of the gastrointestinal tract is difficult owing to the fisheye lens used in endoscopy. To overcome this issue, we developed a phase-shift method to measure three-dimensional (3D) data on a curved surface, which we present herein. Our system allows the creation of 3D shapes on a curved surface by the phase-shift method using a stripe pattern projected from a small projecting device to an object. For evaluation, 88 measurement points were inserted in porcine stomach tissue, attached to a half-pipe jig, with an inner radius of 21 mm. The accuracy and precision of the measurement data for our shape measurement system were compared with the data obtained using an Olympus STM6 measurement microscope. The accuracy of the path length of a simulated protruded lesion was evaluated using a plaster model of the curved stomach and graph paper. The difference in height measures between the measurement microscope and measurement system data was 0.24 mm for the 88 measurement points on the curved surface of the porcine stomach. The error in the path length measurement for a lesion on an underlying curved surface was <1% for a 10-mm lesion. The software was developed for the automated calculation of the major and minor diameters of each lesion. The accuracy of our measurement system could improve the accuracy of determining the size of lesions, whether protruded or depressed, regardless of the curvature of the underlying surface.

2.
Ann Biomed Eng ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38955890

ABSTRACT

Many recent studies have used boil-and-bite style instrumented mouthguards to measure head kinematics during impact in sports. Instrumented mouthguards promise greater accuracy than their predecessors because of their superior ability to couple directly to the skull. These mouthguards have been validated in the lab and on the field, but little is known about the effects of decoupling during impact. Decoupling can occur for various reasons, such as poor initial fit, wear-and-tear, or excessive impact forces. To understand how decoupling influences measured kinematic error, we fit a boil-and-bite instrumented mouthguard to a 3D-printed dentition mounted to a National Operating Committee on Standards for Athletic Equipment (NOCSAE) headform. We also instrumented the headform with linear accelerometers and angular rate sensors at its center of gravity (CG). We performed a series of pendulum impact tests, varying impactor face and impact direction. We measured linear acceleration and angular velocity, and we calculated angular acceleration from the mouthguard and the headform CG. We created decoupling conditions by varying the gap between the lower jaw and the bottom face of the mouthguard. We tested three gap conditions: 0 mm (control), 1.6 mm, and 4.8 mm. Mouthguard measurements were transformed to the CG and compared to the reference measurements. We found that gap condition, impact duration, and impact direction significantly influenced mouthguard measurement error. Error was higher for larger gaps and in frontal (front and front boss) conditions. Higher errors were also found in padded conditions, but the mouthguards did not collect all rigid impacts due to inherent limitations. We present characteristic decoupling time history curves for each kinematic measurement. Exemplary frequency spectra indicating characteristic decoupling frequencies are also described. Researchers using boil-and-bite instrumented mouthguards should be aware of their limitations when interpreting results and should seek to address decoupling through advanced post-processing techniques when possible.

3.
Br J Clin Psychol ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38956764

ABSTRACT

OBJECTIVES: This study examined the factorial invariance of the factor structure of the Wechsler Intelligence Scale for Children, Fifth Edition (WISC-V) across the UK, US and Australia & New Zealand (A&NZ). The factorial equivalence of cognitive assessments should be demonstrated before assuming cross-culture generalizability and interpretations of score comparisons. METHODS: Data were obtained from the UK, US and A&NZ normative standardizations of the WISC-V. The samples consisted of 415 UK, 2200 US and 528 A&NZ children, aged 6-16. Confirmatory factor analysis was applied separately in each sample to establish the baseline model. Next, tests of factorial invariance were undertaken using the recommended hierarchical approach, firstly across the UK and A&NZ samples and then across the UK and US samples. RESULTS: The five-factor first-order scoring model was found to be excellent fit across all three samples independently. Strict factorial invariance of the WISC-V was demonstrated firstly across the UK and A&NZ and secondly the UK and US nationally representative standardization samples. Comparison of latent means found small but significant differences in female children across the UK and A&NZ samples. CONCLUSIONS: Consistent with previous research, these results demonstrate the generality of the WISC-V factor structure across the UK, US and A&NZ. Furthermore, as the WISC-V factor structure aligns with the Cattell-Horn-Carroll (CHC) model of cognitive abilities, the results add further support to the cross-cultural generalizability of the CHC model. Small but significant differences in latent factor scores found across samples support the development and use of local normative data.

4.
Article in English | MEDLINE | ID: mdl-38956806

ABSTRACT

Objective: This study analyzed the influence of p120-catenin (CTNND1) on the malignant characteristics of glioma and elucidated the potential underlying mechanism. Methods: The p120 expression level was assessed in the brain tissues of 42 glioma patients and 10 patients with epilepsy by using the immunohistochemical method. Meanwhile, quantitative PCR technology was employed to assess the expression of P120 in the brain tissues of 71 glioma patients and 13 epilepsy patients. LN229, U251, and U87 glioma cells were used for in vitro analysis and categorized into four treatment groups: siRNA-BC group (no RNA sequence was transfected), siRNA-NC group (transfected control RNA sequences with no effect), and siRNA-1 and siRNA-2 groups (two p120-specific interfering RNA transfection). p120 expression in these treatment groups was quantified by western blotting assay. The migratory and invasive capabilities of glioma cells were studied by wound healing assay and Transwell invasion assay, respectively, under different treatment conditions. MTT assay and cell cycle and apoptosis assay were used to determine glioma cell proliferation and apoptosis, respectively. Enzyme-labeled assay was performed to measure intracellular calcium ion concentration. Immunofluorescence assay was performed for determining microtubule formation and glioma cell distribution. Results: Brain tissues of the glioma group exhibited a remarkable increase in the p120 expression level as compared to brain tissues of the nontumor group (P < 0.05). Furthermore, a strong positive correlation was noted between the malignancy degree in glioma brain tissues and p120 expression in Western blotting (r = 0.906, P = 0.00) and QT-PCR (F=830.6, P<0.01). Compared to the BC and NC groups, the siRNA transfection groups showed a significant suppression in p120 expression in glioma cells (P < 0.05), with a marked attenuation in the invasive, migratory, and proliferative capabilities of glioma cells as well as an increase in apoptotic potential (P < 0.05). Enzyme-labeled assay showed a remarkable increase in calcium concentration in glioma cells after siRNA treatment. Immunofluorescence assay revealed that the microtubule formation ability of glioma cells reduced after siRNA treatment. Conclusion: p120 has a pivotal involvement in facilitating glioma cell invasion and proliferation by potentially modulating these processes through its involvement in microtubule formation and regulation of intracellular calcium ion levels.

5.
Am J Epidemiol ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38957970

ABSTRACT

In longitudinal studies, the devices used to measure exposures can change from visit to visit. Calibration studies, wherein a subset of participants is measured using both devices at follow-up, may be used to assess between-device differences (i.e., errors). Then, statistical methods are needed to adjust for between-device differences and the missing measurement data that often appear in calibration studies. Regression calibration and multiple imputation are two possible methods. We compared both methods in linear regression with a simulation study, considering various real-world scenarios for a longitudinal study of pulse wave velocity. Regression calibration and multiple imputation were both essentially unbiased, but correctly estimating the standard errors posed challenges. Multiple imputation with predicted mean matching produced close agreement with the empirical standard error. Fully stochastic multiple imputation underestimated the standard error by up to 50%, and regression calibration with bootstrapped standard errors performed slightly better than fully stochastic multiple imputation. Regression calibration was slightly more efficient than either multiple imputation method. The results suggest use of multiple imputation with predictive mean matching over fully stochastic imputation or regression calibration in longitudinal studies where a new device at follow-up might be error-prone compared to the device used at baseline.

6.
Turk J Phys Med Rehabil ; 70(2): 164-170, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38948641

ABSTRACT

Objectives: This study aimed to quantify test-retest reliability and minimal detectable change (MDC) of the four commonly used functional tests in older adults with a high risk of falling. Patients and methods: The cross-sectional study was conducted with 30 community-dwelling older adults (26 females, 4 males; mean age: 73.7±6.0 years; range, 65 to 88 years) with a high fall risk identified by the Thai falls risk assessment test between November 2018 and May 2019. Data from the 10-m walk test at a comfortable gait speed (CGS) and fast gait speed (FGS), timed up and go (TUG) test, five times sit to stand test (FTSST), and 6-min walk test (6MWT) were collected twice for each participant. The interval between test sessions was one week. Test-retest reliability was analyzed by the intraclass correlation coefficient (ICC). Standard error of measurement (SEM) and MDC at the 95% confidence interval (MDC95) were also calculated. Results: The four functional tests had ICC in the range of 0.92 to 0.97. The SEM values of the CGS, FGS, TUG, FTSST, and 6MWT were 0.06 m/sec, 0.04 m/sec, 1.10 sec, 1.30 sec, and 20.60 m, respectively. The MDC95 values of the CGS, FGS, TUG, FTSST, and 6MWT were 0.16 m/sec, 0.12 m/sec, 3.00 sec, 3.50 sec, and 57.20 m, respectively. Conclusion: All functional tests demonstrated excellent test-retest reliability. The SEM and MDC95 of all functional tests were established. These findings can help clinicians interpret the effectiveness of interventions and determine changes in functional ability over time in older adults at high risk of falls.

7.
Article in English | MEDLINE | ID: mdl-38951154

ABSTRACT

PURPOSE: Anxiety sensitivity (AS) refers to fear of anxiety-related sensory arousal and has been revealed to be associated with increased psychological distress and mental problems. Although Anxiety Sensitivity Index-3 (ASI-3) has been confirmed to be effective in evaluating this construct, whether it is consistently applicable in college students is still elusive. The present study aimed to examine the psychometric properties and measurement invariance of Chinese version of ASI-3 (C-ASI-3) among college students experiencing campus lockdown due to novel coronavirus disease 2019 (COVID-19) pandemic. METHODS: A total of 1532 Chinese college students (397, 25.9% males) aged between 16 and 25 were included in this study. Confirmatory factor analysis (CFA) was used to verify the factor structure of C-ASI-3. Multi-group CFA was conducted for analysis of measurement invariance with regard to gender. McDonald's omega values were computed for examination of scale reliability. For criterion, convergent, and divergent validity, average variance extracted (AVE) values for C-ASI-3 subscales, difference between square root of AVE for each factor and inter-factor correlation, as well as pearson correlation and partial correlation between the C-ASI-3 and other three scales, including the Depression, Anxiety, and Stress Scale-21 (DASS-21), the State-Trait Anxiety Inventory (STAI), and the Fear of COVID-19 scale (FCV-19 S) were evaluated. RESULTS: The C-ASI-3 presented a three-factor scale structure with fit indices being as follows: χ2/df = 11.590, CFI = 0.938, RMSEA = 0.083, SRMR = 0.042. Strict measurement invariance was reached across gender. Regarding convergent validity, the C-ASI-3 had a high correlation with the DASS-21 (r = 0.597, p < 0.01) and the STAI (r = 0.504, p < 0.01). All AVE values for C-ASI-3 subscales were above 0.5. In terms of divergent validity, the C-ASI-3 had medium correlation with the FCV-19 S (r = 0.360, p < 0.01). Square of root of AVE for each factor was higher that inter-factor correlation. McDonald's omega values of the three dimensions ranged from 0.898 ~ 0.958. CONCLUSION: The C-ASI-3 has acceptable psychometric properties among college students. College students with different gender have consistent understanding on the scale construct.

8.
Am J Primatol ; : e23661, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951734

ABSTRACT

Respiration is an invaluable signal that facilitates the real-time observation of physiological dynamics. In recent years, the advancement of noncontact measurement technology has gained momentum in capturing physiological activities in natural settings. This technology is anticipated to be found not only in humans but also in nonhuman primates. Currently, the predominant noncontact approach for nonhuman animals involves measuring vital signs through subtle variations in skin color. However, this approach is limited when addressing areas of the body covered with hair or when working in outdoor settings under fluctuating sunlight. To overcome this issue, we focused on noncontact respiratory measurements using millimeter-wave radar. Millimeter-wave radar systems, which employ millimeter waves that can penetrate animal fur and estimate respiration-derived periodic body motion, exhibit minimal susceptibility to sunlight interference. Thus, this method shows potential for conducting noncontact vital measurements in natural and outdoor settings. In this study, we validated a millimeter-wave radar methodology for capturing respiration in outdoor-housed rhesus macaques (Macaca mulatta). The radar was positioned beyond the captive enclosure and maintained at a distance >5 m from the target. Millimeter waves were transmitted to the target, and the reflected waves were used to estimate skin surface displacement associated with respiration. The results revealed periodic skin surface displacement, and the estimated respiratory rates weres within the reported range of respiratory rates for rhesus macaques. These results suggest the potential applicability of millimeter-wave radar for noncontact respiration monitoring in outdoor-living macaques without anesthesia or immobilization. The continued advancement of noncontact vital measurement technology will contribute to understanding primate mental and physical dynamics during their daily life.

9.
Biol Sport ; 41(3): 231-241, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38952920

ABSTRACT

Despite the importance of strength and power in rugby skills and match outcomes, there exists a noticeable gap in the measurement consistency and estimation of a true change of typical assessments designed to assess these qualities. To address this gap, we investigated the between-session reliability, interrelationships, and minimal detectable changes (MDC) of commonly used strength and power measures in team sports. Sixteen national-level rugby 7 s players were tested on two occasions, one week apart. Both the best and average (of 2-3 trials) peak force, peak power, height, distance, and/or strength indices during countermovement jump (CMJ), drop jump (DJ), isometric mid-thigh pull (IMTP), plyometric push-up (PPU), and standing long jump (SLJ) were obtained. Furthermore, one-repetition maximum (1RM) strength for bench press and back squat, reactive strength index, and dynamic strength index were also determined. Reliability was assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV), and used for MDC calculations, and interrelationships between variables were determined using correlation coefficients. Reliability was excellent for bench press, back squat, and SLJ (ICCs > 0.91); high to excellent for IMTP peak force, all CMJ, and DJ (except best DJ height and contact time), and PPU peak force parameters (ICCs > 0.78), with < 10% CVs (except PPU peak power). MDCs were generally smaller for average than best values. Large to very large relationships (r = 0.60 to 0.85) were observed between bench press, back squat, and IMTP with selected parameters of CMJ and PPU (p < 0.05), but not in DJ and SLJ. In conclusion, selected measures of strength and power displayed high to excellent reproducibility, with average values (rather than best) offering more stable assessments, and "smaller" MDCs. Based upon the relationships, it can be inferred that maximising strength would likely contribute to enhanced explosive performance.

10.
J Exerc Sci Fit ; 22(4): 322-328, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38947123

ABSTRACT

Background: The perceived benefits and barriers to physical activity play crucial roles in determining daily physical activity levels. However, previous studies have employed tools lacking adequate validation, leading to inconsistent conclusions about the impact of these two factors. Therefore, this national, population-based study was conducted to assess the psychometric properties, measurement invariance, and predictive validity of the Chinese versions of the perceived benefits (C-PBEPA) and barriers to physical activity (C-PBAPA) scales. Methods: The final sample (N = 2942, 49.3 % for boys) was randomly split into two subsamples. The first subsample was used for exploratory factor analysis and the second subsample was used for confirmatory factor analysis. Measurement invariance across gender and age groups were examined. Structural equation models were developed to examine the predictive validity of the revised C-PBEPA and C-PBAPA on moderate to vigorous PA. Results: The results showed that both scales were unidimensional, had excellent model fit (e.g., X 2/df < 3, CFI >0.9, RMSEA <0.06) and demonstrated convergent validity. Findings also revealed lack of scalar invariance for C-PBAPA between preadolescents and adolescents' groups (ΔCFI >0.01) and supported the predictive validity of both scales (p < 0.001). Conclusion: The study demonstrated that the revised C-PBEPA and C-PBAPA are valid scales for measuring Chinese adolescents' perceived benefits and barriers to PA.

11.
EJNMMI Phys ; 11(1): 55, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951275

ABSTRACT

PURPOSE: This study proposes a practical method for evaluating 2D spatial resolution with scatter on a CZT planar detector gamma camera, which is simpler and faster than the NEMA method. It is used to characterize the influence of distance on spatial resolution FWHM on a CZT camera equipped with a WEHR collimator. METHODS: The practical method uses linear sources tilted with respect to the detector axes. The spatial resolution full width at half maximum (FWHM) with four tilt angles was compared to the FWHM evaluated using the NEMA NU1-2018 method. Spatial resolution FWHM was also assessed with tilted sources acquired at distances of 0 to 20 cm using a single angle, with and without the post-processing image enhancement proposed by the manufacturer. RESULTS: Estimated spatial resolution FWHM with tilted sources was close to the spatial resolution FWHM estimated at 7.63 mm by the NEMA method, with deviations ranging from - 5.62 to 4.59% at 10 cm depending on the angle considered. The study of spatial resolution FWHM dependence on distance indicates that, for distances less than 3 cm, the FWHM no longer decreases with distance. The manufacturer's post-processing reduces the FWHM by an average of 15%. CONCLUSION: The practical method is quicker to implement and gives comparable results to the NEMA reference method for spatial resolution FWHM. Evaluation of spatial resolution with linear sources at short distances from the collimator is limited by the collimator effect and signal digitization. The tilted source method can be used to measure spatial resolution quickly and easily under clinical conditions for CZT planar cameras.

12.
Front Integr Neurosci ; 18: 1365672, 2024.
Article in English | MEDLINE | ID: mdl-38957213

ABSTRACT

This paper proposes a new model of stress that integrates earlier models and adds insights from developmental psychology. Previous models describe the behavioral and physical effects of stress events, but have not explained the translation of experiences into stress itself. The Developmental Model of Stress shows how psychosocial developmental challenges in childhood create persistent negative beliefs and behaviors that increase threat perception and maladaptive stress responses. These developmental challenges produce early psychological and physiological predispositions for increased stress responses over time. Ongoing stress leads to dysregulation of physical stress-response systems (allostatic load), which is associated with multiple diseases. High allostatic load provides the necessary preconditions for the diathesis-stress model, which says the addition of an acute stressor to a weakened or predisposed system can lead to disease development. The paper also documents the evolving measurement of stress to better understand the stress-disease relationship, helping to resolve conflicting results between studies. The Developmental Model of Stress was combined with clinician insight and patient reports to build an integrative framework for understanding the role of stress in the development and progression of multiple sclerosis (MS). It includes the first mapping of maladaptive beliefs and behaviors arising from developmental challenges that are common to people with MS. An initial comparison shows these may be distinct from those of people with other chronic diseases. These beliefs and behaviors form the predisposing factors and contribute to the triggering factors, which are the acute stressors triggering disease onset. These often took two forms, a prolonged incident experienced as feeling trapped or stuck, and threat of a breach in a relationship. The reinforcing factors add the stress of a chronic disease with a poor prognosis and seemingly random symptom fluctuation, still managed with the same beliefs and behaviors developed in childhood, increasing physiological dysregulation and symptom severity. A pilot study is described in which these three categories of stress factors in MS were explicitly addressed. This study noted clinically important improvements in physical and mental well-being, providing preliminary support for the Developmental Model. Future research might expand on the pilot using a more robust sample and design.

13.
Gait Posture ; 113: 232-237, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38959554

ABSTRACT

BACKGROUND: Gait kinematics differ between settings and among young and older adults with and without knee osteoarthritis. Out-of-lab data has a variety of walking bout characteristics compared to controlled in-lab settings. The effect of walking bout duration on gait analysis results is unclear, and there is no standardized procedure for segmenting or selecting out-of-lab data for analysis. RESEARCH QUESTION: Do gait kinematics differ by bout duration or setting in young and older adults with and without knee osteoarthritis? METHODS: Ten young (28.1±3.5 yrs), ten older adults (60.8±3.3 yrs), and ten older adults with knee osteoarthritis (64.1±3.6 yrs) performed a standard in-lab gait analysis followed by a prescribed walking route outside the lab at a comfortable speed with four IMUs. Walking speed, stride length, and sagittal hip, knee, and ankle angular excursion (ROM) were calculated for each identified stride. Out-of-lab strides included straight-line, level walking divided into strides that occurred during long (>60 s) or short (≤60 s) bouts. Gait kinematics were compared between in-lab and both out-of-lab bout durations among groups. RESULTS: Significant main effects of setting or duration were found for walking speed and stride length, but there were no significant differences in hip, knee, or ankle joint ROM. Walking speed and stride length were greater in-lab followed by long and short bout out-of-lab. No significant interaction was observed between group and setting or bout duration for any spatiotemporal variables or joint ROMs. SIGNIFICANCE: Out-of-lab gait data can be beneficial in identifying gait characteristics that individuals may not encounter in the traditional lab setting. Setting has an impact on walking kinematics, so comparisons of in-lab and free-living gait may be impacted by the duration of walking bouts. A standardized approach for to analyzing out-of-lab gait data is important for comparing studies and populations.

14.
Qual Life Res ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38961008

ABSTRACT

PURPOSE: To identify utility-based patient-reported outcome measures (PROMs) for assessing health-related quality of life (HRQoL) in cardiac rehabilitation and secondary prevention programs (CR) and appraise existing evidence on their measurement properties. Secondly, to link their items to the International Classification of Functioning Disability and Health (ICF) and the International Consortium of Health Outcome Measures (ICHOM) domains for cardiovascular disease (CVD). METHODS: Eight databases were searched. The review followed the COSMIN and JBI guidelines for measurement properties systematic reviews and PRISMA 2020 reporting guidelines. Non-experimental and observational empirical studies of patients ≥ 18 years of age with CVD undergoing CR and assessed quality of life (QoL) or HRQoL using utility-based PROMs or one accompanied by health state utilities were included. RESULTS: Nine PROMs were identified with evidence on measurement properties for three measures: the German translations of SF-12, EQ-5D-5L, and MacNew heart disease HRQoL questionnaire. There was moderate quality evidence for responsiveness and hypothesis testing of the SF-12 and EQ-5D-5L, and high-quality evidence for responsiveness and hypothesis testing for the MacNew. All items of SF-12 and EQ-5D were linked to ICF categories, but four items of the MacNew were not classified or defined. All the PROM domains were mapped onto similar constructs from the ICHOM global sets. CONCLUSION: Three utility-based PROMs validated in CR were identified: the German versions of the EQ-5D and SF-12 and the MacNew questionnaire. These PROMs are linked to a breadth of ICF categories and all ICHOM global sets. Additional validation studies of PROMs in CR are required.

15.
Qual Life Res ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38961010

ABSTRACT

PURPOSE: Systematic reviews evaluating and comparing the measurement properties of outcome measurement instruments (OMIs) play an important role in OMI selection. Earlier overviews of review quality (2007, 2014) evidenced substantial concerns with regards to alignment to scientific standards. This overview aimed to investigate whether the quality of recent systematic reviews of OMIs lives up to the current scientific standards. METHODS: One hundred systematic reviews of OMIs published from June 1, 2021 onwards were randomly selected through a systematic literature search performed on March 17, 2022 in MEDLINE and EMBASE. The quality of systematic reviews was appraised by two independent reviewers. An updated data extraction form was informed by the earlier studies, and results were compared to these earlier studies' findings. RESULTS: A quarter of the reviews had an unclear research question or aim, and in 22% of the reviews the search strategy did not match the aim. Half of the reviews had an incomprehensive search strategy, because relevant search terms were not included. In 63% of the reviews (compared to 41% in 2014 and 30% in 2007) a risk of bias assessment was conducted. In 73% of the reviews (some) measurement properties were evaluated (58% in 2014 and 55% in 2007). In 60% of the reviews the data were (partly) synthesized (42% in 2014 and 7% in 2007); evaluation of measurement properties and data syntheses was not conducted separately for subscales in the majority. Certainty assessments of the quality of the total body of evidence were conducted in only 33% of reviews (not assessed in 2014 and 2007). The majority (58%) did not make any recommendations on which OMI (not) to use. CONCLUSION: Despite clear improvements in risk of bias assessments, measurement property evaluation and data synthesis, specifying the research question, conducting the search strategy and performing a certainty assessment remain poor. To ensure that systematic reviews of OMIs meet current scientific standards, more consistent conduct and reporting of systematic reviews of OMIs is needed.

16.
Matern Child Nutr ; : e13677, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38961562

ABSTRACT

Poor measurement quality has set back the utility of anthropometry in defining childhood malnutrition, prompting calls for alternative measurement techniques. This study aimed to assess the reliability of anthropometric measurements using a digital height board in comparison to an analog height board in Namibian children under 5 years of age. A cross-sectional, descriptive study was conducted (n = 425) between the age of 6 and 59 months, using anthropometric measurements of weight, height and mid-upper arm circumference. Two trained enumerators each collected four height measurements of each child: two using an analog height board and two using a digi-board. The repeated height measurements between and within the enumerators were used to determine intra- and interobserver reliability. Reliability of the digi-board was assessed using the technical error of measurement (TEM), relative TEM (%TEM), intraclass correlation and a Bland-Altman analysis to assess the agreement between the two methods. In all these assessments, the analog height board was considered as the gold standard and used for comparison. The digi-board showed superiority to the analog height board in terms of reliability (analog TEM = 0.22, digi-board TEM = 0.16). Although the digi-board has potential to improve child anthropometry, further clinical and large survey studies are needed to validate the used of this tool in routine population-based surveys.

17.
Health Serv Res ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38961668

ABSTRACT

OBJECTIVE: To determine the feasibility of integrating Medicare Advantage (MA) admissions into the Centers for Medicare & Medicaid Services (CMS) hospital outcome measures through combining Medicare Advantage Organization (MAO) encounter- and hospital-submitted inpatient claims. DATA SOURCES AND STUDY SETTING: Beneficiary enrollment data and inpatient claims from the Integrated Data Repository for 2018 Medicare discharges. STUDY DESIGN: We examined timeliness of MA claims, compared diagnosis and procedure codes for admissions with claims submitted both by the hospital and the MAO (overlapping claims), and compared demographic characteristics and principal diagnosis codes for admissions with overlapping claims versus admissions with a single claim. DATA COLLECTION/EXTRACTION METHODS: We combined hospital- and MAO-submitted claims to capture MA admissions from all hospitals and identified overlapping claims. For admissions with only an MAO-submitted claim, we used provider history data to match the National Provider Identifier on the claim to the CMS Certification Number used for reporting purposes in CMS outcome measures. PRINCIPAL FINDINGS: After removing void and duplicate claims, identifying overlapped claims between the hospital- and MAO-submitted datasets, restricting claims to acute care and critical access hospitals, and bundling same admission claims, we identified 5,078,611 MA admissions. Of these, 76.1% were submitted by both the hospital and MAO, 14.2% were submitted only by MAOs, and 9.7% were submitted only by hospitals. Nearly all (96.6%) hospital-submitted claims were submitted within 3 months after a one-year performance period, versus 85.2% of MAO-submitted claims. Among the 3,864,524 admissions with overlapping claims, 98.9% shared the same principal diagnosis code between the two datasets, and 97.5% shared the same first procedure code. CONCLUSIONS: Inpatient MA data are feasible for use in CMS claims-based hospital outcome measures. We recommend prioritizing hospital-submitted over MAO-submitted claims for analyses. Monitoring, data audits, and ongoing policies to improve the quality of MA data are important approaches to address potential missing data and errors.

18.
Article in English | MEDLINE | ID: mdl-38961743

ABSTRACT

INTRODUCTION: The study aimed to assess the psychometric quality of the Peer Mental Health Stigmatization Scale - Revised (PMHSS-R), by examining its factorial structure among young adults in Ireland and Argentina. METHOD: A total of 429 participants aged between 18 and 25 years old were recruited (n = 187 Ireland, n = 242 Argentina). The PMHSS-R was completed by Irish participants and was translated, pilot-studied, and subsequently completed by Argentinian participants. RESULTS: A Confirmatory Factor Analysis demonstrated optimal factor loadings for an eight-item solution and acceptable internal consistency for both scale dimensions in the Argentinian sample. Satisfactory levels of partial scalar invariance were achieved between countries, indicating that the scale measures mental health stigma consistently across cultures. DISCUSSION AND CONCLUSIONS: Our findings highlight the PMHSS-R as a cross-culturally valid and reliable psychometric instrument to evaluate interventions targeting stigma. In conclusion, the PMHSS-R can be used in cross-cultural research to compare levels of mental health stigma and investigate the interplay between stigma and other psychologically relevant constructs between different countries and cultural contexts.

19.
Psychometrika ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963537

ABSTRACT

Wu and Browne (Psychometrika 80(3):571-600, 2015. https://doi.org/10.1007/s11336-015-9451-3 ; henceforth W &B) introduced the notion of adventitious error to explicitly take into account approximate goodness of fit of covariance structure models (CSMs). Adventitious error supposes that observed covariance matrices are not directly sampled from a theoretical population covariance matrix but from an operational population covariance matrix. This operational matrix is randomly distorted from the theoretical matrix due to differences in study implementations. W &B showed how adventitious error is linked to the root mean square error of approximation (RMSEA) and how the standard errors (SEs) of parameter estimates are augmented. Our contribution is to consider adventitious error as a general phenomenon and to illustrate its consequences. Using simulations, we illustrate that its impact on SEs can be generalized to pairwise relations between variables beyond the CSM context. Using derivations, we conjecture that heterogeneity of effect sizes across studies and overestimation of statistical power can both be interpreted as stemming from adventitious error. We also show that adventitious error, if it occurs, has an impact on the uncertainty of composite measurement outcomes such as factor scores and summed scores. The results of a simulation study show that the impact on measurement uncertainty is rather small although larger for factor scores than for summed scores. Adventitious error is an assumption about the data generating mechanism; the notion offers a statistical framework for understanding a broad range of phenomena, including approximate fit, varying research findings, heterogeneity of effects, and overestimates of power.

20.
Microsc Res Tech ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963689

ABSTRACT

The quantification of 3D particle field is of interest for a vast range of fields. While in-line particle holography (PH) can provide high-resolution measurements of particles, it suffers from speckle noise. Plenoptic imaging (PI) is less susceptible to speckle noises, but it involves a trade-off between spatial and angular resolution, rendering images with low resolution. Here, we report a simple microscopy setup with the goals of getting the strengths of both techniques. It is built with off-the-shelf and cost-effective components including a photographic lens, a diaphragm, and a CCD camera. The cost of the microscopy setup is affordable to small labs and individual researchers. The pupil plane of the proposed setup can be mechanically accessible, allowing us to implement pupil plane modulation and increase the depth of field (DOF) without requiring any additional relay lenses. It also allows us to understand the working principle of pupil plane modulation clearly, benefiting microscopy education. It illuminates the sample (particles) using diffuse white light, and thus avoids the problem of speckle noise. It captures multiple perspective images via pupil plane modulation, without requiring trading off angular and spatial resolution. We validate the setup with 2D and 3D particle samples. RESEARCH HIGHLIGHTS: We report a simple and cost-effective microscopy setup with the goals of getting the strengths of plenoptic imaging and in-line particle holography. It is built with off-the-shelf and cost-effective components. The cost of the microscopy setup is affordable to small labs and individual researchers. The pupil plane of the proposed setup can be mechanically accessible, allowing us to implement pupil plane modulation and increase the DOF without requiring any additional relay lenses. It also allows us to understand the working principle of pupil plane modulation clearly, benefiting microscopy education. It illuminates the sample (particles) using diffuse white light, and thus avoids the problem of speckle noise. It captures multiple perspective images via pupil plane modulation, without requiring trading off angular and spatial resolution. We validate the setup with 2D and 3D particle samples.

SELECTION OF CITATIONS
SEARCH DETAIL