Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(8)2024 Apr 14.
Article in English | MEDLINE | ID: mdl-38676131

ABSTRACT

Tire-road noise deteriorates the sound quality of a vehicle's interior and affects the driving safety and comfort. Obtaining low interior noise is a challenge for passenger car manufacturers. Traditional passive noise control (PNC) is efficient for canceling high frequency noise but not useful for low frequency noise, while active noise control (ANC), according to the residual error signal, can generate an anti-noise signal to reduce the original noise. Most research has focused on improving the control effect for a feedforward ANC system. However, this paper emphasizes a feedback ANC system based on a signal microphone sensor. There are two main contributions in this study to improve automotive cabin sound comfort. One is that the algorithm of the feedback ANC system using a single microphone sensor without a reference noise signal is proposed based on the Filtered-x Least Mean Square method. The other is that the algorithm applies additive random noise online to estimate the secondary path model. A simulation was implemented based on measured real road noise data, and the simulation results indicate that the proposed feedback ANC system with the single microphone sensor can effectively attenuate road noise. This study shows the feasibility of applying a feedback ANC system in automobiles to increase the cabin sound quality.

2.
J Biophotonics ; 14(4): e202000352, 2021 04.
Article in English | MEDLINE | ID: mdl-33369169

ABSTRACT

This work proposes a new online monitoring method for an assistance during laser osteotomy. The method allows differentiating the type of ablated tissue and the applied dose of laser energy. The setup analyzes the laser-induced acoustic emission, detected by an airborne microphone sensor. The analysis of the acoustic signals is carried out using a machine learning algorithm that is pre-trained in a supervised manner. The efficiency of the method is experimentally evaluated with several types of tissues, which are: skin, fat, muscle, and bone. Several cutting-edge machine learning frameworks are tested for the comparison with the resulting classification accuracy in the range of 84-99%. It is shown that the datasets for the training of the machine learning algorithms are easy to collect in real-life conditions. In the future, this method could assist the doctors during laser osteotomy, minimizing the damage of the nearby healthy tissues and provide cleaner pathologic tissue removal.


Subject(s)
Algorithms , Machine Learning , Acoustics , Lasers , Osteotomy
3.
Sensors (Basel) ; 16(12)2016 Dec 17.
Article in English | MEDLINE | ID: mdl-27999321

ABSTRACT

Most existing wearable gait analysis methods focus on the analysis of data obtained from inertial sensors. This paper proposes a novel, low-cost, wireless and wearable gait analysis system which uses microphone sensors to collect footstep sound signals during walking. This is the first time a microphone sensor is used as a wearable gait analysis device as far as we know. Based on this system, a gait analysis algorithm for estimating the temporal parameters of gait is presented. The algorithm fully uses the fusion of two feet footstep sound signals and includes three stages: footstep detection, heel-strike event and toe-on event detection, and calculation of gait temporal parameters. Experimental results show that with a total of 240 data sequences and 1732 steps collected using three different gait data collection strategies from 15 healthy subjects, the proposed system achieves an average 0.955 F1-measure for footstep detection, an average 94.52% accuracy rate for heel-strike detection and 94.25% accuracy rate for toe-on detection. Using these detection results, nine temporal related gait parameters are calculated and these parameters are consistent with their corresponding normal gait temporal parameters and labeled data calculation results. The results verify the effectiveness of our proposed system and algorithm for temporal gait parameter estimation.


Subject(s)
Gait/physiology , Wearable Electronic Devices , Acoustics , Adult , Algorithms , Female , Humans , Male , Middle Aged , Probability , Software , Time Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL