Turk J Ophthalmol ; 52(5): 348-351, 2022 10 28.
Article in English | MEDLINE | ID: mdl-36317825

ABSTRACT

This case report aims to describe a modified continuous suturing technique for firm fixation of a human amniotic membrane graft in a patient with persistent epithelial defect (PED) after a chemical eye injury. As a result of this technique, the amniotic membrane (AM) was firmly fixed to the corneal surface with eight continuous and locked episcleral sutures that resembled an octagon graft. This technique was performed in a 14-year-old patient with PED after a chemical corneal burn. Three weeks after the surgery, the PED was completely healed. This simple continuous suturing technique can allow firm and stable fixation of AM grafts on the ocular surface in cases of PED after chemical burn. It may prevent early loss of the graft and facilitate corneal epithelial wound healing.


Subject(s)
Burns, Chemical , Corneal Injuries , Eye Burns , Humans , Adolescent , Amnion/transplantation , Burns, Chemical/diagnosis , Burns, Chemical/surgery , Corneal Injuries/surgery , Eye Burns/chemically induced , Eye Burns/diagnosis , Eye Burns/surgery , Cornea