Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 861
Filter
2.
Int J Cardiol Heart Vasc ; 53: 101430, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39228973

ABSTRACT

Background: Limited data exist on the prognostic value of changes in pulse pressure (PP, the difference between systolic and diastolic blood pressure) during hospitalization for patients with coronary artery disease who have undergone percutaneous coronary intervention (PCI). Methods: In the Clinical Deep Data Accumulation System (CLIDAS), we studied 8,708 patients who underwent PCI. We aimed to examine the association between discharge PP and cardiovascular outcomes. PP was measured before PCI and at discharge. Patients were divided into five groups (quintiles) based on the change in PPQ1 (-18.0 ± 9.9 mmHg), Q2 (-3.8 ± 2.6), Q3 (reference; 3.7 ± 2.0), Q4 (11.3 ± 2.6), and Q5 (27.5 ± 11.2). We then analyzed the relationship between PP change and outcomes. Results: The mean patient age was 70 ± 11 years, with 6,851 (78 %) men and 3,786 (43 %) having acute coronary syndrome. U-shaped relationships were observed for the incidence rates of major adverse cardiac or cerebrovascular events (MACCE, a composite endpoint of cardiovascular death, myocardial infarction, and stroke), revascularization, and hospitalization for heart failure (HF). After adjusting for confounding factors, higher PP at discharge was associated with an increased risk of MACCE (adjusted hazard ratio 1.41; 95 %CI, 1.06-1.87 in Q5 [73.9 ± 9.3 mmHg]). Evaluating PP change revealed a U-shaped association with MACCE (1.50; 1.11-2.02 in Q1 and 1.47; 0.98-2.20 in Q5). Additionally, Q5 had a higher risk for hospitalization for HF (1.37; 1.00-1.88). Conclusions: Our findings demonstrate a U-shaped association between changes in PP and cardiovascular outcomes. This data suggests the significance of blood pressure control during hospitalization for patients who have undergone PCI.

3.
Med Pharm Rep ; 97(3): 270-279, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39234453

ABSTRACT

Background and aims: The non-dipper status represented by blood pressure reduction by less than 10 percent during sleep is present in about 50 percent of patients with type 2 diabetes (T2D) and hypertension, a pattern associated with more frequent cardiovascular complications and reserved prognosis. This study analyzed the predictive risk factors associated with the different dipper profiles, especially with the nocturnal pattern, following the mean arterial pressure (MAP), the mean heart rate (MHR), and the mean pulse pressure (MPP) in patients with T2D and hypertension, established by ambulatory blood pressure monitoring (ABPM). Method: 166 consecutive patients with type 2 diabetes mellitus and hypertension were included in a cross-sectional study, and they underwent 24-hour ABPM. We excluded patients with secondary hypertension, acute coronary disease and heart failure, with oncologic or endocrine disease. The simple and multiple linear regression models were performed predicting 24-hour, day and night MAP, MHR, and MPP according to various predictors, using software R version 4.3.1. Results: There were 80 non-dippers (48.20%), 57 dippers (34.34%), 22 reverse-dippers (13.25%) and seven extreme-dippers (4.21%). A statistically significant association was observed between MAP 24-hour and total cholesterol (TC) (higher TC values were associated with higher MAP /24 h values): adjusted coefficient B of the regression slope: 0.09, 95% confidence interval CI (0.04-0.15), p=0.003. In the multivariate analysis: adjusted B: 8.64, 95% CI (-14.67-2.61), p=0.006, beta-blockers reached the threshold of statistical significance in relation to MHR/24 h, their presence decreasing the heart rate. PP/24 hours was associated in the multivariate analysis with age: adjusted B: 0.45, 95% CI (0.05-0.85), p=0.28; abdominal circumference: 0.26, 95% CI (0.03-0.49), p=0.028, and total cholesterol: 0.1, 95% CI (0.02-0.17), p=0.013. Diabetic nephropathy was statistically significantly associated with PP/24 h: adjusted B: 10.19, 95% CI (1.24-19.14), p=0.027. Conclusions: High cholesterol was associated with higher values of MAP and PP. Beta-blocker treatment lowered non-dipper MHR. Age and AC were correlated with increased PP values. These are predictive risk factors associated with the status of non-dippers established by ABPM, and they represent a veritable link to the non-dipper pattern in patients with T2D and hypertension.

4.
Mol Biol Rep ; 51(1): 888, 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39105829

ABSTRACT

OBJECTIVE: To explore the relationship between rs1410996 polymorphism of CFH gene and essential hypertension (EH) in the Yunnan Han population. METHODS: rs1410996 of CFH gene was genotyped based on the collected clinical phenotypes of the EH patients (n = 520) and healthy people (n = 494). RESULTS: On the genotype model and dominance model, there was no relationship between rs1410996 of CFH gene and EH after adjustment (P > 0.05). On the dominance model of male EH patients, the pulse pressure (PP) level of CC genotype carriers was higher than that of (CT + TT) genotype carriers after adjustment (P < 0.05). CONCLUSION: rs1410996 of CFH gene has no correlation with the genetic susceptibility to EH in the Yunnan Han population, but it is related to the PP level in male patients.


Subject(s)
Asian People , Complement Factor H , Essential Hypertension , Genetic Predisposition to Disease , Genotype , Polymorphism, Single Nucleotide , Humans , Male , Essential Hypertension/genetics , Middle Aged , Female , China , Complement Factor H/genetics , Polymorphism, Single Nucleotide/genetics , Asian People/genetics , Gene Frequency/genetics , Aged , Case-Control Studies , Adult , Hypertension/genetics , Genetic Association Studies/methods , Alleles , Blood Pressure/genetics
5.
J Clin Med ; 13(15)2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39124585

ABSTRACT

Background: Modern management of preeclampsia can be optimized by tailoring the targeted treatment of hypertension to an individual's hemodynamic profile. Growing evidence suggests different phenotypes of preeclampsia, including those with a hyperdynamic profile and those complicated by uteroplacental insufficiency. Fetal growth restriction (FGR) is believed to be a result of uteroplacental insufficiency. There is a paucity of research examining the characteristics of patients with severe preeclampsia who do and who do not develop FGR. We aimed to elucidate which hemodynamic parameters differed between these two groups. Methods: All patients admitted to a single referral center with severe preeclampsia were identified. Patients were included if they had a live birth at 23 weeks of gestation or higher. Multiple gestations and pregnancies complicated by fetal congenital anomalies and/or HELLP syndrome were excluded. FGR was defined as a sonographic estimation of fetal weight (EFW) < 10th percentile or abdominal circumference (AC) < 10th percentile. Results: There were 76% significantly lower odds of overall pulse pressure upon admission for those with severe preeclampsia comorbid with FGR (aOR = 0.24, 95% CI = 0.07-0.83). Advanced gestational age on admission was associated with lower odds of severely abnormal labs and severely elevated diastolic blood pressure in preeclampsia also complicated by FGR. Conclusions: Subtypes of preeclampsia with and without FGR may be hemodynamically evaluated by assessing pulse pressure on admission.

6.
Sci Rep ; 14(1): 17948, 2024 08 02.
Article in English | MEDLINE | ID: mdl-39095555

ABSTRACT

Prediabetes and related complications constitute significant public health burdens globally. As an indicator closely associated with abnormal glucose metabolism and atherosclerosis, the utility of Pulse Pressure Index (PPI) as a prediabetes risk marker has not been explored. We performed a retrospective cohort analysis to investigate this putative association between PPI and prediabetes hazard. Our analysis encompassed 183,517 Chinese adults ≥ 20 years registered within the Rich Healthcare Group 2010-2016. PPI was defined as (systolic blood pressure - diastolic blood pressure)/systolic blood pressure. The relationship between PPI and prediabetes risk was assessed via Cox proportional hazards regression modeling. Non-linearity evaluations applied cubic spline fitting approaches alongside smooth curve analysis. Inflection points of PPI concerning prediabetes hazard were determined using two-piecewise Cox models. During a median follow-up of 3 years (2.17-3.96 years), new-onset prediabetes was documented in 20,607 patients (11.23%). Multivariate regression analysis showed that PPI was an independent risk factor for prediabetes, and the risk of prediabetes increased by 0.6% for every 1% increase in PPI (Hazard Ratio [HR]: 1.006, 95% Confidence Interval [CI] 1.004-1.008, P < 0.001). This association was non-significant for PPI ≤ 37.41% yet exhibited a sharp upsurge when PPI surpassed 37.41% (HR: 1.013, 95% CI 1.005-1.021, P = 0.0029). Our analysis unveils a positive, non-linear association between PPI and future prediabetes risk. Within defined PPI ranges, this relationship is negligible but dramatically elevates beyond identified thresholds.


Subject(s)
Blood Pressure , Prediabetic State , Humans , Prediabetic State/epidemiology , Male , Female , Middle Aged , Retrospective Studies , Adult , Risk Factors , Proportional Hazards Models , Aged , Incidence , China/epidemiology
7.
Article in English | MEDLINE | ID: mdl-39168807

ABSTRACT

BACKGROUND AND AIMS: Insulin resistance (IR) is a major risk factor for cardiovascular disease. Recently, a novel index (triglyceride-glucose index-TyG) has been proposed as a surrogate marker of IR and a better expression of IR than the Homeostatic Model Assessment of IR (HOMA-IR) index. Few and heterogeneous data are so far available on the relationship between vascular damage and this novel index. Therefore, we aimed to estimate the predictive role of TyG, in comparison with the HOMA-IR, on the development of arterial stiffening (AS), defined as a pulse pressure>60 mmHg, in an 8-year follow-up observation of a sample of non-diabetic adult men (the Olivetti Heart Study). METHODS AND RESULTS: The analysis included 527 non-diabetic men, with normal arterial elasticity at baseline and not on antihypertensive or hypolipidemic treatment. TyG was significantly greater in those who developed AS than those who did not (p = 0.006). On the contrary, the HOMA-IR index was not different between the two groups (p = 0.24). Similar trends were shown by logistic regression analysis adjusting for main confounders. After the stratification by the optimal cut-off point, values of TyG >4.70 were significantly associated with the development of AS, also after adjustment for main confounders. On the contrary, the HOMA-IR index >1.90 was not associated with the risk of AS development in multivariate models. CONCLUSION: The results of this study indicate a predictive role of TyG on AS, independently of the main potential confounders. Moreover, the predictive power of TyG seems to be greater than that of the HOMA-IR index.

8.
BMC Cardiovasc Disord ; 24(1): 399, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090575

ABSTRACT

BACKGROUND: Hypertension is the leading risk factor for subclinical target-organ damage (TOD) and cardiovascular disease (CVD). Little is known about the relationship between different pressure measures and subclinical TOD, especially in young populations. We compared the strength of associations of subclinical TOD markers with perfusion and pulsatile pressure in young adults. METHODS: A total of 1 187 young adults from the African-PREDICT study were included. Ambulatory mean arterial pressure (MAP) and pulse pressure (PP) was obtained. Markers of subclinical TOD were measured and included left ventricular mass index (LVMi), carotid intimamedia thickness (cIMT), carotidfemoral pulse wave velocity (cfPWV), central retinal arteriolar equivalent (CRAE) and albumin to creatinine ratio (ACR). RESULTS: Measures of sub-clinical TOD (cIMT, cfPWV and CRAE), associated stronger with perfusion pressure (all p < 0.001) than pulsatile pressure in unadjusted models. Stronger associations were found between cfPWV (adjusted R2 = 0.26), CRAE (adjusted R2 = 0.12) and perfusion pressure (all p ≤ 0.001) than pulsatile pressure independent of several non-modifiable and modifiable risk factors. CONCLUSIONS: In young, healthy adults, perfusion pressure is more strongly associated with subclinical TOD markers than pulsatile pressure. These findings contribute to the understanding of the development of early cardiovascular changes and may guide future intervention strategies.


Subject(s)
Arterial Pressure , Humans , Male , Female , Adult , Young Adult , South Africa/epidemiology , Hypertension/physiopathology , Hypertension/diagnosis , Hypertension/epidemiology , Pulse Wave Analysis , Cross-Sectional Studies , Carotid-Femoral Pulse Wave Velocity , Risk Assessment , Carotid Intima-Media Thickness , Risk Factors , Age Factors , Blood Pressure Monitoring, Ambulatory , Predictive Value of Tests , Vascular Stiffness , Pulsatile Flow , Black People , Adolescent
9.
Ann Intensive Care ; 14(1): 108, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980442

ABSTRACT

BACKGROUND: Dynamic arterial elastance (Eadyn) has been investigated for its ability to predict hypotension during the weaning of vasopressors. Our study focused on assessing Eadyn's performance in the context of critically ill adult patients admitted to the intensive care unit, regardless of diagnosis. MAIN BODY: Our study was conducted in accordance with the Preferred Reported Items for Systematic Reviews and Meta-Analysis checklist. The protocol was registered in PROSPERO (CRD42023421462) on May 26, 2023. We included prospective observational studies from the MEDLINE and Embase databases through May 2023. Five studies involving 183 patients were included in the quantitative analysis. We extracted data related to patient clinical characteristics, and information about Eadyn measurement methods, results, and norepinephrine dose. Most patients (76%) were diagnosed with septic shock, while the remaining patients required norepinephrine for other reasons. The average pressure responsiveness rate was 36.20%. The synthesized results yielded an area under the curve of 0.85, with a sensitivity of 0.87 (95% CI 0.74-0.93), specificity of 0.76 (95% CI 0.68-0.83), and diagnostic odds ratio of 19.07 (95% CI 8.47-42.92). Subgroup analyses indicated no variations in the Eadyn based on norepinephrine dosage, the Eadyn measurement device, or the Eadyn diagnostic cutoff to predict cessation of vasopressor support. CONCLUSIONS: Eadyn, evaluated through subgroup analyses, demonstrated good predictive ability for the discontinuation of vasopressor support in critically ill patients.

10.
Sci Rep ; 14(1): 15086, 2024 07 02.
Article in English | MEDLINE | ID: mdl-38956152

ABSTRACT

Elevated levels of the gut pro-hormone Proneurotensin (proNT) have been found to predict development of cardiovascular disease. However, it is still unknown whether higher proNT levels are associated with subclinical vascular damage. Herein, we investigated the relationship between higher proNT concentrations and augmented pulse pressure (PP) and carotid intima-media thickness (cIMT), indicators of increased arterial stiffness and subclinical atherosclerosis, respectively. Clinical characteristics, PP and cIMT were evaluated in 154 non-diabetic individuals stratified into tertiles according to fasting serum proNT concentrations. We found that, subjects with higher proNT levels exhibited a worse lipid profile and insulin sensitivity, increased C-reactive protein levels, along with higher values of PP and cIMT as compared to the lowest proNT tertile. Prevalence of elevated PP (≥ 60 mmHg) and subclinical carotid atherosclerosis (IMT > 0.9 mm) was increased in the highest tertile of proNT. In a logistic regression analysis adjusted for several confounders, subjects with higher proNT levels displayed a fivefold raised risk of having elevated PP values (OR 5.36; 95%CI 1.04-27.28; P = 0.05) and early carotid atherosclerosis (OR 4.81; 95%CI 1.39-16.57; P = 0.01) as compared to the lowest proNT tertile. In conclusion, higher circulating levels of proNT are a biomarker of subclinical vascular damage independent of other atherosclerotic risk factors.


Subject(s)
Blood Pressure , Carotid Intima-Media Thickness , Protein Precursors , Humans , Male , Female , Middle Aged , Protein Precursors/blood , Adult , Neurotensin/blood , Carotid Artery Diseases/blood , Vascular Stiffness , Risk Factors , C-Reactive Protein/metabolism , C-Reactive Protein/analysis , Biomarkers/blood , Atherosclerosis/blood , Aged
11.
Am J Obstet Gynecol ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38969197

ABSTRACT

Fluid management in obstetrical care is crucial because of the complex physiological conditions of pregnancy, which complicate clinical manifestations and fluid balance management. This expert review examined the use of point-of-care ultrasound to evaluate and monitor the response to fluid therapy in pregnant patients. Pregnancy induces substantial physiological changes, including increased cardiac output and glomerular filtration rate, decreased systemic vascular resistance, and decreased plasma oncotic pressure. Conditions, such as preeclampsia, further complicate fluid management because of decreased intravascular volume and increased capillary permeability. Traditional methods for assessing fluid volume status, such as physical examination and invasive monitoring, are often unreliable or inappropriate. Point-of-care ultrasound provides a noninvasive, rapid, and reliable means to assess fluid responsiveness, which is essential for managing fluid therapy in pregnant patients. This review details the various point-of-care ultrasound modalities used to measure dynamic changes in fluid status, focusing on the evaluation of the inferior vena cava, lung ultrasound, and left ventricular outflow tract. Inferior vena cava ultrasound in spontaneously breathing patients determines diameter variability, predicts fluid responsiveness, and is feasible even late in pregnancy. Lung ultrasound is crucial for detecting early signs of pulmonary edema before clinical symptoms arise and is more accurate than traditional radiography. The left ventricular outflow tract velocity time integral assesses stroke volume response to fluid challenges, providing a quantifiable measure of cardiac function, which is particularly beneficial in critical care settings where rapid and accurate fluid management is essential. This expert review synthesizes current evidence and practice guidelines, suggesting the integration of point-of-care ultrasound as a fundamental aspect of fluid management in obstetrics. It calls for ongoing research to enhance techniques and validate their use in broader clinical settings, aiming to improve outcomes for pregnant patients and their babies by preventing complications associated with both under- and overresuscitation.

12.
Cureus ; 16(6): e63191, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39070370

ABSTRACT

BACKGROUND: Cardiorespiratory function is one of the key health indicators that promote good health. Knowing the correlation between body mass index (BMI) and cardiorespiratory functioning might assist in the creation of evidence-based therapies that focus on addressing difficulties associated with obesity. OBJECTIVE: To assess the correlation between BMI and cardiorespiratory functions among medical students at Northern Border University. MATERIALS AND METHODS: A cross-sectional study was conducted among medical students at Northern Border University, Saudi Arabia. The blood pressure (BP), respiratory rate (RR), heart rate (HR), mean arterial pressure (MAP), pulse pressure (PP), and BMI of the students were measured. RESULTS: The mean age of the students was 17.1 ± 1.9 years. Nearly 40% of students were overweight or obese. Our study revealed a significant positive correlation between BMI and BP, RR, tidal volume (TV), and MAP. CONCLUSIONS:  The correlation analysis of our study revealed a significant positive correlation of BMI with BP, RR, TV, and MAP.

13.
Hypertens Res ; 47(9): 2478-2488, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39039284

ABSTRACT

Pulse pressure amplification (PPA) is the brachial-to-aortic pulse pressure ratio and decreases with age and cardiovascular risk factors. This individual-participant meta-analysis of population studies aimed to define an outcome-driven threshold for PPA. Incidence rates and standardized multivariable-adjusted hazard ratios (HRs) of cardiovascular and coronary endpoints associated with PPA, as assessed by the SphygmoCor software, were evaluated in the International Database of Central Arterial Properties for Risk Stratification (n = 5608). Model refinement was assessed by the integrated discrimination (IDI) and net reclassification (NRI) improvement. Age ranged from 30 to 96 years (median 53.6). Over 4.1 years (median), 255 and 109 participants experienced a cardiovascular or coronary endpoint. In a randomly defined discovery subset of 3945 individuals, the rounded risk-carrying PPA thresholds converged at 1.3. The HRs for cardiovascular and coronary endpoints contrasting PPA < 1.3 vs ≥1.3 were 1.54 (95% confidence interval [CI]: 1.00-2.36) and 2.45 (CI: 1.20-5.01), respectively. Models were well calibrated, findings were replicated in the remaining 1663 individuals analyzed as test dataset, and NRI was significant for both endpoints. The HRs associating cardiovascular and coronary endpoints per PPA threshold in individuals <60 vs ≥60 years were 3.86 vs 1.19 and 6.21 vs 1.77, respectively. The proportion of high-risk women (PPA < 1.3) was higher at younger age (<60 vs ≥60 years: 67.7% vs 61.5%; P < 0.001). In conclusion, over and beyond common risk factors, a brachial-to-central PP ratio of <1.3 is a forerunner of cardiovascular coronary complications and is an underestimated risk factor in women aged 30-60 years. Our study supports pulse wave analysis for risk stratification.


Subject(s)
Blood Pressure , Cardiovascular Diseases , Humans , Middle Aged , Aged , Adult , Female , Blood Pressure/physiology , Male , Cardiovascular Diseases/physiopathology , Aged, 80 and over , Risk Factors , Heart Disease Risk Factors , Pulse Wave Analysis , Brachial Artery/physiology
14.
J Robot Surg ; 18(1): 258, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38900397

ABSTRACT

This study examined how different goal-directed fluid therapy types affected low blood pressure and fluid infusion during robot-assisted laparoscopic gynecological surgery. They used carotid corrected flow time (FTc) and tidal volume stimulation pulse pressure variation (VtPPV) to check the patient's volume status and responsiveness. The findings indicated that various fluid therapy targets significantly influence intraoperative hypotension and fluid requirements. However, the study exclusively employed unilateral carotid ultrasound assessments, potentially overlooking physiological or pathological variations in blood flow between the left and right carotid arteries. This methodological choice raises concerns as guidelines recommend bilateral measurements for a more comprehensive evaluation. The lack of bilateral assessments could affect the study's reliability and reproducibility. Justifying the unilateral measurement approach is essential for validating clinical findings. Future research should adopt bilateral carotid ultrasound assessments or provide a detailed rationale for unilateral measurements to enhance the robustness and accuracy of clinical evaluations.


Subject(s)
Fluid Therapy , Gynecologic Surgical Procedures , Hypotension , Laparoscopy , Robotic Surgical Procedures , Humans , Gynecologic Surgical Procedures/methods , Laparoscopy/methods , Robotic Surgical Procedures/methods , Fluid Therapy/methods , Hypotension/prevention & control , Hypotension/etiology , Female , Intraoperative Complications/prevention & control , Carotid Arteries/surgery
15.
Anaesthesiologie ; 73(7): 462-468, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38942901

ABSTRACT

BACKGROUND: Reliable assessment of fluid responsiveness with pulse pressure variation (PPV) depends on certain ventilation-related preconditions; however, some of these requirements are in contrast with recommendations for protective ventilation. OBJECTIVE: The aim of this study was to evaluate the applicability of PPV in patients undergoing non-cardiac surgery by retrospectively analyzing intraoperative ventilation data. MATERIAL AND METHODS: Intraoperative ventilation data from three large medical centers in Germany and Switzerland from January to December 2018 were extracted from electronic patient records and pseudonymized; 10,334 complete data sets were analyzed with respect to the ventilation parameters set as well as demographic and medical data. RESULTS: In 6.3% of the 3398 included anesthesia records, patients were ventilated with mean tidal volumes (mTV) > 8 ml/kg predicted body weight (PBW). These would qualify for PPV-based hemodynamic assessment, but the majority were ventilated with lower mTVs. In patients who underwent abdominal surgery (75.5% of analyzed cases), mTVs > 8 ml/kg PBW were used in 5.5% of cases, which did not differ between laparoscopic (44.9%) and open (55.1%) approaches. Other obstacles to the use of PPV, such as elevated positive end-expiratory pressure (PEEP) or increased respiratory rate, were also identified. Of all the cases 6.0% were ventilated with a mTV of > 8 ml/kg PBW and a PEEP of 5-10 cmH2O and 0.3% were ventilated with a mTV > 8 ml/kg PBW and a PEEP of > 10 cmH2O. CONCLUSION: The data suggest that only few patients meet the currently defined TV (of > 8 ml/kg PBW) for assessment of fluid responsiveness using PPV during surgery.


Subject(s)
Fluid Therapy , Operating Rooms , Respiration, Artificial , Tidal Volume , Humans , Female , Retrospective Studies , Male , Middle Aged , Aged , Fluid Therapy/methods , Tidal Volume/physiology , Intraoperative Care/methods , Adult , Switzerland , Blood Pressure/physiology , Positive-Pressure Respiration/methods , Germany
17.
Hellenic J Cardiol ; 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38925251

ABSTRACT

OBJECTIVE: Neurohumoral alterations in heart failure (HF) affect blood pressure variability (BPV) and vascular compliance, but little is known about this subject among patients admitted to the hospital with decompensated HF. This study sought to investigate in-hospital 24-h blood pressure monitoring (BPM)-derived BPV parameters and vascular compliance in patients with decompensated HF and explore the association of these parameters with hospitalization length and in-hospital adverse events. METHODS: A 24-h BPM was applied during the first 6 h of admission to the hospital in patients with decompensated HF. Circadian patterns were determined by the study patients. Average real variability (ARV), pulse pressure index (PPI), pulse stiffening ratio (PSR), and ambulatory arterial stiffness index (AASI) values were calculated from in hospital 24-h BPM recordings. Admission and discharge N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels, length of hospitalization, and in-hospital adverse events were recorded. RESULTS: A total of 167 patients with decompensated HF were included in the study. The dipper group exhibited a greater NT-proBNP decrease with the treatment than the non-dipper group and reverse dipper group. Hospitalization length was shorter in the dipper group than in the non-dipper and reverse dipper groups. Although ARV, AASI, and PSR were independently associated with the length of hospitalization, ARV, AASI, and PPI were independently associated with in-hospital adverse events. CONCLUSION: The post-admission in hospital 24-h BPM-derived parameters (dipper pattern, ARV, PPI, PSR, and AASI) of patients admitted to hospital with decompensated HF provide important prognostic information and predict the length of hospital stay.

18.
Clin Kidney J ; 17(6): sfae152, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38846104

ABSTRACT

Background: Unlike systolic blood pressure (SBP), the prognostic value of diastolic blood pressure (DBP) in kidney function has not been established. We hypothesized that pulse pressure (PP), which is associated with arteriosclerosis, would affect the prognostic value of DBP. Methods: This longitudinal study used data from the Japan Specific Health Checkups Study was conducted between 2008 and 2014. The participants were stratified into three PP subgroups (low PP ≤39, normal PP 40-59 and high PP ≥60 mmHg). The exposures of interest were SBP and DBP, and the association between SBP/DBP and kidney outcomes (30% decline in the estimated glomerular filtration rate from baseline) was examined in each PP subgroup using a Cox proportional hazards model. Results: Among 725 022 participants, 20 414 (2.8%) developed kidney outcomes during a median follow-up period of 34.6 months. Higher SBP was consistently associated with a higher incidence of kidney outcome in all PP subgroups. Although DBP had a positive linear association with the incidence of kidney outcome in low- and normal-PP subgroups, both lower (≤60 mmHg) and higher (≥101 mmHg) DBP were associated with a higher incidence of kidney outcome in the high-PP subgroup, with a U-shaped curve. Hazard ratios (95% confidence intervals) of ≤60 mmHg (reference: 61-80 mmHg in normal-PP subgroup) and ≥101 mmHg were 1.26 (1.15-1.38) and 1.86 (1.62-2.14), respectively. Conclusions: In this large population-based cohort, DBP was differently associated with kidney outcome by PP level; lower DBP was significantly associated with a higher incidence of kidney outcome in the high-PP subgroup but not in the low- and normal-PP subgroups.

19.
J Biophotonics ; 17(7): e202400083, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38695386

ABSTRACT

One of the diagnostic tool for clinical evaluation and disease diagnosis is a pulse waveform analysis. High fidelity radial artery pulse waveforms have been investigated in clinical research to compute central aortic pressure, which has been demonstrated to be predictive of cardiovascular diseases. The radial artery must be inspected from several angles in order to obtain the best pulse waveform for estimate and diagnosis. In this study, we present the design and experimental testing of an optical sensor based on Fiber Bragg Gratings (FBG). A 3D printed device along with the FBG is used to measure the radial artery pulses. The proposed sensor is used for the purpose of quantifying the radial artery pulse waveform across major pulse position point. The suggested optical sensing system can measure the pulse signal with good accuracy. The main characteristic parameters of the pulse can then be retrieved from the processed signal for their use in clinical applications. By conducting experiments under the direction of medical experts, the pulse signals are measured. In order to experimentally validate the sensor, we used it to detect the pulse waveforms at Guan position of the wrist's radial artery in accordance with the diagnostic standards. The findings show that combining optical technologies for physiological monitoring and radial artery pulse waveform monitoring using FBG in clinical applications are highly feasible.


Subject(s)
Radial Artery , Radial Artery/physiology , Humans , Blood Pressure , Optical Fibers , Equipment Design , Optical Phenomena , Blood Pressure Determination/instrumentation , Blood Pressure Determination/methods , Optical Devices
20.
ESC Heart Fail ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724009

ABSTRACT

AIMS: This study evaluated how well serial pulse pressure (PP) and PP adjusted by the vasoactive inotropic score (VIS) predicted venoarterial extracorporeal membrane oxygenation (VA-ECMO) weaning success and clinical outcomes in acute myocardial infarction complicated by cardiogenic shock (AMI-CS) patients. METHODS AND RESULTS: A total of 213 patients with AMI-CS who received VA-ECMO between January 2010 and August 2021 were enrolled in the institutional ECMO registry. Serial PP and VIS were measured immediately, 12, 24, and 48 h after VA-ECMO insertion. PP adjusted by VIS was defined as PP/√VIS. The primary outcome was successful VA-ECMO weaning. Successful weaning from VA-ECMO was observed in 151 patients (70.9%). Immediately after VA-ECMO insertion, PP [successful vs. failed weaning, 26.0 (15.5-46.0) vs. 21.0 (12.5-33.0), P = 0.386] and PP/√VIS [11.1 (5.1-25.0) vs. 6.0 (3.1-14.2), P = 0.118] did not differ between the successful and failed weaning groups. Serial PP and PP adjusted by VIS at 12, 24, and 48 h after VA-ECMO insertion were significantly higher in patients with successful weaning than those with failed weaning [successful vs. failed weaning, 24.0 (4.0-38.0) vs. 12.5 (6.0-25.5), P = 0.007 for 12 h PP, and 10.1 (5.7-22.0) vs. 2.9 (1.7-5.9), P < 0.001 for 12 h PP/√VIS]. The 12 h PP/√VIS showed better discriminative function for successful weaning than 12 h PP alone [area under the curve (AUC) 0.80, 95% confidence interval (CI) 0.72-0.88, P < 0.001 vs. AUC 0.67, 95% CI 0.57-0.77, P = 0.002]. Patients with a low 12 h PP/√VIS (≤7) had higher rates of in-hospital mortality (44.4% vs. 19.8%, P < 0.001) and 6 month follow-up mortality (hazard ratio 2.41, 95% CI 1.49-3.90, P < 0.001) than those with a high 12 h PP/√VIS (>7). CONCLUSIONS: PP adjusted by VIS taken 12 h following VA-ECMO initiation can predict weaning from VA-ECMO more successfully than PP alone, and its low value was associated with a higher risk of mortality in AMI-CS patients.

SELECTION OF CITATIONS
SEARCH DETAIL