Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Diagn Microbiol Infect Dis ; 98(4): 115199, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32979617

ABSTRACT

COVID-19 positive (194) and negative (212) pneumonia patients were selected to analyze bacterial pathogens coinfection. Results showed that 50% of COVID-19 patients were coinfected or carried bacterial pathogens. Bordetella pertussis infection rate was significantly higher in positive patients. Consequently, preventions should be taken to control bacterial pathogens coinfection in COVID-19 patients.


Subject(s)
Coinfection/epidemiology , Coronavirus Infections/pathology , Pneumonia, Viral/pathology , Pseudomonas Infections/epidemiology , Whooping Cough/epidemiology , Adolescent , Adult , Aged , Aged, 80 and over , Betacoronavirus , Bordetella pertussis/isolation & purification , COVID-19 , Child , Child, Preschool , Coinfection/microbiology , Coinfection/pathology , Female , Humans , Infant , Male , Middle Aged , Pandemics , Pseudomonas aeruginosa/isolation & purification , Respiratory Tract Infections/epidemiology , Respiratory Tract Infections/microbiology , Respiratory Tract Infections/pathology , SARS-CoV-2 , Young Adult
2.
J Clin Microbiol ; 58(2)2020 01 28.
Article in English | MEDLINE | ID: mdl-31748320

ABSTRACT

There are several convenient and accurate molecular assays to detect respiratory bacterial infection. The NeoPlex RB-8 detection kit (NeoPlex RB-8) is a new multiplex real-time PCR assay that simultaneously detects Streptococcus pneumoniae, Mycoplasma pneumoniae, Chlamydophila pneumoniae, Legionella pneumophila, Haemophilus influenzae, Bordetella pertussis, Bordetella parapertussis, and Moraxella catarrhalis in a single test. This study compared the clinical concordance of NeoPlex RB-8 with another method, Seeplex PneumoBacter ACE detection assay (Seeplex PB ACE), which simultaneously detects S. pneumoniae, M. pneumoniae, C. pneumoniae, L. pneumophila, H. influenzae, and B. pertussis We tested 2,137 nasopharyngeal swab and sputum specimens using both assays. For discordant Bordetella parapertussis and M. catarrhalis specimens, we also performed bidirectional sequencing. For S. pneumoniae, M. pneumoniae, C. pneumoniae, L. pneumophila, H. influenzae, and B. pertussis, which are detected by both NeoPlex RB-8 and Seeplex PB ACE, the positive and negative agreement between the two assays ranged from 91.7 to 100% (κ = 0.918 to 1). S. pneumoniae and H. influenzae were the most discordant targets and measured with higher sensitivity and specificity by NeoPlex RB-8 than Seeplex PB ACE. For Bordetella parapertussis and M. catarrhalis, which are not detected by Seeplex PB ACE, NeoPlex RB-8 sensitivity and specificity were >99%. Overall, NeoPlex RB-8 was highly comparable to Seeplex PB ACE, but NeoPlex RB-8 was more clinically accurate, with higher throughput and more convenience.


Subject(s)
Bacteria/classification , Bacterial Infections/diagnosis , Multiplex Polymerase Chain Reaction/standards , Reagent Kits, Diagnostic/standards , Respiratory Tract Infections/microbiology , Bacteria/pathogenicity , Bacterial Infections/microbiology , Humans , Multiplex Polymerase Chain Reaction/methods , Nasopharynx/microbiology , Respiratory Tract Infections/diagnosis , Sensitivity and Specificity , Sputum/microbiology
SELECTION OF CITATIONS
SEARCH DETAIL