1.
Diagn Cytopathol ; 51(2): 123-134, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36181474

ABSTRACT

BACKGROUND: The diagnostic performance of cytology was compared with the frozen results and its usability was evaluated as a rapid diagnosis method in intraoperative thoracic surgery in a single institution (Istanbul, Turkey). METHODS: All 197 subsequent patient specimens (cases) from 158 patients who were sent to our department from the thoracic surgery clinic for an intraoperative diagnosis request between the years 2016 and 2021 were evaluated. Obtained results from frozen and cytology were compared with final paraffin section diagnoses. Lesions were grouped into three different groups as nonneoplastic, benign, and malignant neoplasms. RESULTS: Diagnostic accuracy values of cytology and frozen sections in intraoperative consultation were 98.8% and 99.4%, respectively. Sensitivity values of cytology and frozen sections in intraoperative consultation were 96.3% and 98.7%, respectively. Specificity values of cytology and frozen sections in intraoperative consultation were 100% and 100%, respectively. Negative predictive values of cytology and frozen sections in intraoperative consultation were 96.7% and 98.9%, respectively. Positive predictive values of cytology and frozen sections in intraoperative consultation were 100% and 100%, respectively. Kappa statistics between cytology and frozen revealed a very high interrater reliability (Cohen's Kappa value: 0.911; p = .001; p < .01). The difficulty in distinguishing primary and metastatic carcinoma, which is mostly undecided in frozen sections and the definitive diagnosis is left to paraffin sections, seems also be a problem in the cytological examination. CONCLUSIONS: Cytological diagnosis can be used in the evaluation of small biopsy specimens that require tissue preservation in intraoperative consultation, especially for immunohistochemical and advanced genetic studies.


Subject(s)
Carcinoma , Frozen Sections , Humans , Frozen Sections/methods , Reproducibility of Results , Developing Countries , Paraffin , Intraoperative Period , Sensitivity and Specificity
2.
Pathol Int ; 70(1): 31-39, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31823459

ABSTRACT

To address the diagnostic performance of scratch-imprint cytology (SIC), in this study we compared intraoperative diagnoses of pulmonary lesions between SIC and frozen section histology (FSH) for accuracy with respect to the final pathological diagnosis. We histologically divided 206 pulmonary lesions (resected surgically) into two groups (benign and malignant) and compared each intraoperative diagnosis by SIC and FSH with the final pathological diagnoses. We also examined the radiological existence of pure ground-glass opacity (GGO) nodules in each group. The diagnostic sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 91.5%, 100%, 100%, 63.6%, and 92.6%, respectively for SIC, and 98.2%, 100%, 100%, 92.1% and 98.5%, respectively, for FSH. Thus, we concluded that diagnosis by SIC is reliable for malignancy, but not for benign lesions. All pure GGO nodules (19; 9.2%) were noninfectious and malignant with a high accuracy of FSH diagnosis (100%), in comparison with those of low accuracy with a SIC diagnosis (57.9%). SIC can be an appropriate intraoperative diagnostic tool where multiple cytotechnologists observe intraoperative SIC preparations scratched evenly across the whole lesion including the peripheral area of the mass.


Subject(s)
Cytodiagnosis/methods , Lung Diseases/diagnosis , Frozen Sections/methods , Humans , Sensitivity and Specificity