1.
Front Surg ; 11: 1279194, 2024.
Article in English | MEDLINE | ID: mdl-38601877

ABSTRACT

Purpose: We prospectively evaluate the short-term clinical and radiographic outcomes of the only Chinese domestically produced trabecular titanium acetabular cup(3D ACT™ cup) in primary total hip arthroplasty (THA), aiming to provide evidence-based support for its clinical application. Methods: A total of 236 patients, who underwent primary THA using 3D ACT™ cup in the Department of Joint Surgery at our hospital between January 2017 and June 2019, were included in this study. General patient data, imaging information, functional scores, and complications were collected to evaluate the early clinical efficacy. Results: All patients were followed up for 33-52 months, with an average of (42.2 ± 9.2) months. At the last follow-up, the preoperative HHS score increased significantly from 43.7 ± 6.8 to 85.6 ± 9.3 points (P < 0.01). Similarly, the preoperative WOMAC scores showed significant improvement from 59.2 ± 5.8 to 13.1 ± 3.5 points (P < 0.01). 92.3% of the patients expressed satisfaction or high satisfaction with the clinical outcome. Furthermore, 87.7% of the acetabular cups were positioned within the Lewinnek safe zone, achieving successful reconstruction of the acetabular rotation center. The cup survival rate at the last follow-up was 100%. Conclusions: The utilization of the only Chinese domestically manufactured 3D printing trabecular titanium acetabular cup in primary THA demonstrated favorable short-term clinical and radiographic outcomes. The acetabular cup exhibits excellent initial stability, high survival rate, and favorable osseointegration, leading to a significant enhancement in pain relief and functional improvement. In the future, larger sample sizes and multicenter prospective randomized controlled trials will be required to validate the long-term safety and effectiveness of this 3D ACT™ cup.

2.
BMC Musculoskelet Disord ; 23(1): 636, 2022 Jul 04.
Article in English | MEDLINE | ID: mdl-35787270

ABSTRACT

BACKGROUND: Revision total hip arthroplasty (THA) has been a challenge for surgeons. The purpose of this study was to explore the short-to mid-term clinical and radiological outcomes of Chinese patients who underwent revision THA using a new off-the-shelf three-dimensional (3D)-printed trabecular titanium (TT) acetabular cup by comparison with a conventional porous coated titanium acetabular cup, to provide a reference for the recommendation of this prostheses. METHODS: A retrospective analysis of 57 patients (57 hips) who received revision THA was performed from January 2016 to June 2019. A total of 23 patients received 3D-printed cups (observation group) and 34 patients received non-3D-printed cups (control group). Clinical scores including Visual Analogue Scale (VAS), Harris Hip Score (HHS) and Short Form 36 (SF-36), upward movement of the hip center of rotation(HCOR)and limb-length discrepancy (LLD), stabilization and bone ingrowth of cups were compared between two groups. The multivariate linear regression was used to determine the factors potentially influencing the HHS score. Postoperative complications in the two groups were also recorded. RESULTS: All 57 patients were routinely followed up. The average follow-up durations in the control and observation groups were 43.57 ± 13.68 (24-65) months and 41.82 ± 11.44 (24-64) months, respectively (p = 0.618). The postoperative clinical scores significantly improved in both groups compared to the preoperative scores (p < 0.001). The VAS score did not significantly differ between the groups at 3 (p = 0.946) or 12 (p = 0.681) months postoperatively, or at the last follow-up (p = 0.885). The HHS score did not significantly differ between the groups at 3 months (p = 0.378) postoperatively but differed at 12 months (p < 0.001) postoperatively and the last follow-up (p < 0.001). The SF-36 score did not significantly differ between the groups at 3 months (p = 0.289) postoperatively, but was significantly different at 12 months (p < 0.001) postoperatively and the last follow-up (p < 0.001). Compared with the control group, the postoperative recovery of HCOR and LLD was better in the observation group. All cups remained stable, with no loosening throughout the follow-up period. But the observation group had a significantly better rate of bone ingrowth compared to the control group (p = 0.037). Multivariate linear regression analysis showed that different cup types, upward movement of the HCOR, and LLD influenced the HHS score at the last follow-up (p < 0.001, p = 0.005, respectively). None of the patients exhibited severe postoperative complications. CONCLUSION: The new off-the-shelf 3D-printed TT acetabular cup demonstrated encouraging short-to mid-term clinical outcomes in Chinese patients. It can effectively relieve pain, improve hip function, provide satisfactory biological fixation and high survival rate. But further follow up is necessary to assess its long-term outcomes.


Subject(s)
Postoperative Complications , Titanium , China , Humans , Reoperation , Retrospective Studies
3.
J Orthop Surg Res ; 15(1): 383, 2020 Sep 04.
Article in English | MEDLINE | ID: mdl-32887636

ABSTRACT

BACKGROUND: Aseptic cup loosening is still one of the main reasons leading to acetabular cup failures. 3D printing porous trabecular titanium metal acetabular cup may provide good initial stability and secondary fixation because of its highly interconnected, porous structure. Few large sample studies have reported the clinical outcomes of electron beam melting (EBM) porous titanium acetabular cup in Chinese population. METHODS: We retrospectively collected and analyzed the clinical data of a total of 92 consecutive patients between January 2013 and November 2017, with an average follow-up of 48.2 ± 3.6 months. Clinical outcomes included Harris Hip Score (HHS), the Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index, satisfaction rate, and cup survival rate were evaluated. Radiographic assessments were conducted to evaluate osteointegration. RESULTS: HHS scores improved significantly while the WOMAC score decreased significantly at the latest follow-up (p < 0.001). The satisfaction rate (prevalence of satisfied or very satisfied) was 91.3%. No acetabular cup failures occurred. Radiolucent lines appeared in 15 cases (18 hips) and disappeared in 6 months. No cup loosening signs found until the last follow-up. The overall survival rate of implantation is 99.1% (cup survival rate 100%). CONCLUSION: The new EBM-produced 3D ACT™ cup demonstrated us its favorable short- to mid-term clinical outcomes in Chinese THA patients. It can provide high acetabular cup survival rate, great clinical improvements and excellent biological fixation. Further investigations are needed to confirm its long-term outcomes.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Printing, Three-Dimensional , Prosthesis Design/methods , Titanium , Aged , Asian People , Female , Follow-Up Studies , Humans , Male , Middle Aged , Porosity , Prosthesis Failure , Time Factors , Treatment Outcome