Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.502
Filter
3.
J Emerg Med ; 2024 May 19.
Article in English | MEDLINE | ID: mdl-39242347

ABSTRACT

BACKGROUND: Supraventricular tachycardia (SVT) is commonly evaluated in the emergency department (ED). While troponin has been shown to be elevated in SVT, its usefulness for predicting coronary artery disease and future adverse cardiovascular outcomes has not been shown. OBJECTIVES: We aimed to evaluate the prognostic utility of troponin measurement as part of SVT management in the ED. METHODS: We performed a literature search in the PubMed and Scopus databases from inception to August 30, 2023, including all studies reporting troponin measurements in adult patients (age > 18 years) presenting to the ED with supraventricular tachycardia. The primary outcome of interest for this study was the prevalence of elevated troponin in patients with SVT. Secondary outcomes included the prevalence of major adverse cardiac events (MACE) and additional cardiac testing with significant findings. RESULTS: We included 7 studies (500 patients) in our analysis. Six studies reported the number of patients with SVT and elevated troponin, with a pooled prevalence of 46% (95% CI 27-66%, I2 93%). The pooled prevalence of all MACE in our study was 6% (95% CI 1-25%), while the prevalence for MACE among patients with elevated serum troponin levels was 11% (95% CI 4-27%). CONCLUSIONS: Troponin levels are frequently ordered for ED patients with SVT and are often elevated. However, this review suggests that they have low prognostic value in predicting MACE.

5.
JACC Adv ; 3(9): 101206, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39253712

ABSTRACT

Background: Coronary plaque is common among people with HIV (PWH) with low-to-moderate traditional atherosclerotic cardiovascular disease (ASCVD) risk. Objectives: The purpose of this study was to determine the association of high-sensitivity cardiac troponin T (hs-cTnT) levels with coronary plaque characteristics and evaluate if hs-cTnT improves identification of these features beyond traditional ASCVD risk factors among PWH. Methods: Among PWH receiving stable antiretroviral therapy with low-to-moderate ASCVD risk and no known history of ASCVD, hs-cTnT levels and measures of plaque by coronary computed tomography angiography were assessed. Primary outcomes included the association of hs-cTnT level with the presence of any plaque, vulnerable plaque, coronary artery calcium (CAC) score, and Leaman score. Assessment of model discrimination of hs-cTnT for plaque characteristics was also performed. Results: The cohort included 708 U.S. participants with a mean age of 51 ± 6 years, 119 (17%) females, a median ASCVD risk score of 4.4% (Q1-Q3: 2.5%-6.6%), and a median hs-cTnT level of 6.7 ng/L (detectable level ≥6 ng/L in 61%). Any plaque was present in 341 (48%), vulnerable plaque in 155 (22%), CAC>100 in 68 (10%), and a Leaman score >5 in 105 (15%). After adjustment for ASCVD risk score, participants with hs-cTnT >9.6 ng/L (highest category) versus an undetectable level (<6 ng/L) had a greater relative risk for any plaque (1.37, 95% CI: 1.12-1.67), vulnerable plaque (1.47, 95% CI: 1.16-1.87), CAC>100 (2.58, 95% CI: 1.37-4.83), and Leaman score >5 (2.13, 95% CI: 1.32-3.46). The addition of hs-cTnT level modestly improved the discrimination of ASCVD risk score to identify critical plaque features. Conclusions: In PWH without known ASCVD, hs-cTnT levels were strongly associated with and improved prediction of subclinical coronary plaque. (Evaluating the Use of Pitavastatin to Reduce the Risk of Cardiovascular Disease in HIV-Infected Adults [REPRIEVE]; NCT02344290).

6.
Clin Exp Emerg Med ; 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39237137

ABSTRACT

BACKGROUND: Chest pain, a common emergency department 35 (ED) presentation, requires rapid evaluation. Optical technology-based non-invasive wearable devices (Infrasensor, RCE, Carlsbad, CA) rapidly and transcutaneously assesses cardiac Troponin I (cTnI). OBJECTIVES: To perform a pilot study describing the performance of the Infrasensor in cTnI defined cohorts. METHODS: This was a 10-hospital prospective observational study in healthy US subjects with a normal cTnI, and in patients with an elevated local cTnI. Healthy subjects were without disease, defined by a negative questionnaire and bloodwork, had a 3-minute Infrasensor measurement and blood samples for high-sensitivity cardiac troponin I (hs-cTnI), n-terminal pro-B-type natriuretic peptide (NTproBNP), creatinine, and glycosylated hemoglobin (HbA1c). Elevated cTnI's patients had the same Infrasensor and blood sample measurements. Using a cross validation technique, a cTnI based binary classification model that did, and did not, include age was trained with 80%, and validated on 20% (n=168; elevated hs-cTnI equally distributed across 5 folds) of the overall cohort. RESULTS: Of 840 patients, 727 (87.5%) were non-elevated cTnI controls and the remainder, n=113, had elevated cTnI. Median (25th, 75th percentiles) age was 61 (52, 71) and 48 (32, 57) years for the elevated and healthy control cohorts, respectively. Overall, 50.5% were female, with 29.2% and 52.7% in the elevated and non-elevated troponin cohorts respectively. Overall, the sensitivity, specificity, negative and positive predictive values of the Infrasensor for identifying an elevated cTnI were 0.9, 0.7, 0.98 and 0.48 respectively, with a C-statistic of 0.90 (0.89-0.99). CONCLUSIONS: The Infrasensor identifies elevated cTnI within 3 minutes of application.

7.
Clin Kidney J ; 17(9): sfae247, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39246629

ABSTRACT

Background: The diagnosis of acute myocardial infarction (AMI) using high-sensitivity cardiac troponin T (hs-cTnT) remains challenging in patients with kidney dysfunction. Methods: In this large, multicenter cohort study, a total of 20 912 adults who underwent coronary angiography were included. Kidney function-specific cut-off values of hs-cTnT were determined to improve the specificity without sacrificing sensitivity, as compared with that using traditional cut-off value (14 ng/L) in the normal kidney function group. The diagnostic accuracy of the novel cut-off values was validated in an independent validation cohort. Results: In the derivation cohort (n = 12 900), 3247 patients had an estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2. Even in the absence of AMI, 50.2% of participants with eGFR <60 mL/min/1.73 m2 had a hs-cTnT concentration ≥14 ng/L. Using 14 ng/L as the threshold of hs-cTnT for diagnosing AMI led to a significantly reduced specificity and positive predictive value in patients with kidney dysfunction, as compared with that in patients with normal kidney function. The kidney function-specific cut-off values were determined as 14, 18 and 48 ng/L for patients with eGFR >60, 60-30 and <30 mL/min/1.73 m2, respectively. Using the novel cut-off values, the specificities for diagnosing AMI in participants with different levels of kidney dysfunction were remarkably improved (from 9.1%-52.7% to 52.8-63.0%), without compromising sensitivity (96.6%-97.9%). Similar improvement of diagnostic accuracy was observed in the validation cohort (n = 8012). Conclusions: The kidney function-specific cut-off values of hs-cTnT may help clinicians to accurately diagnose AMI in patients with kidney dysfunction and avoid the potential overtreatment in practice.

8.
Am Heart J Plus ; 45: 100441, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39246678

ABSTRACT

Background: Magnetocardiography (MCG) may provide a rapid diagnostic option for patients presenting with chest pain in the emergency department (ED). Case summaries: This case series presents two instances from a multicenter study, where MCG could have served as a rapid, non-invasive diagnostic tool for chest pain patients. In both cases, multiple high-sensitivity troponin (hsTn) tests yielded incorrect evidence of ischemia. In the first case, multiple positive hsTn tests led to the patient requiring 23 h of observation care, while MCG rapidly ruled out acute coronary syndrome (ACS). In the second case, MCG revealed findings indicative of cardiac ischemia where serial ECGs did not indicate ischemia and serial hsTns were normal. Subsequent cardiac catheterization confirmed 99 % stenosis in the patient's left main and left anterior descending arteries, necessitating coronary artery bypass grafting (CABG). Conclusion: MCG offers a rapid, painless, non-invasive, radiation free assessment for patients presenting with acute chest pain. Integrating MCG into ED workflows has the potential to improve throughput, reduce the need for subsequent patient observation or inpatient admission, and minimize or eliminate the need for other more expensive non-invasive cardiac testing. MCG avoids some of the problems associated with other methods for diagnosing ischemia. MCG does not involve radiation or the use of pharmacologic agents which have a risk for allergic reactions and anaphylaxis, or the need for an intravenous line. Stress tests are frequently contraindicated or unable to be performed in patients on various medications, may require patient cooperation and in the case of exercise stress tests, the patient's capability to exercise. MCG requires no special patient preparation.

9.
Cureus ; 16(8): e66512, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39246852

ABSTRACT

BACKGROUND:  Evaluating high-sensitivity troponin I levels in emergency medicine is critical for diagnosing acute myocardial infarction (AMI). This study aims to evaluate the central laboratory versus bedside troponin I test in the emergency department of a tertiary care center. MATERIAL AND METHODS:  This prospective observational study was conducted at Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune, Maharashtra, India, from October to December 2023. Patient samples were analyzed in the central laboratory using the Dimension EXL 200 (Siemens® Healthcare Diagnostics Inc., Erlangen, Germany) as the gold standard test and through point-of-care testing using the TriageTrue® (Quidel Corporation, San Diego, CA) high-sensitivity troponin I kit, which was run on the Triage® MeterPro® device (Quidel Corporation, San Diego, CA). This device quantitatively determines troponin I in ethylenediaminetetraacetic acid-anticoagulated whole blood and plasma specimens. The results were compared. Statistical analysis was performed using SPSS version 18 (SPSS Inc., Chicago, IL). An unpaired t-test was performed to compare the difference in time taken using the two testing methods. RESULT:  The mean time for obtaining troponin I results was substantially shorter with bedside testing (14.91 minutes, standard deviation (SD) = 0.5) than with laboratory testing (119.1 minutes, SD = 5.03). Statistical analysis revealed a significant difference (t = -172.36, p < 0.001). A chi-square test was conducted to assess the disparity between the two testing methods, yielding a chi-square value of 32.64 and a p value of 0.00001, indicating a significant difference between bedside testing and laboratory testing. CONCLUSION: The bedside high-sensitivity troponin I test offers a considerable advantage over laboratory testing regarding turnaround time within the emergency medicine department in India. This rapid diagnostic capability is crucial for timely management, which is beneficial for patients inconclusive of acute coronary syndrome-like non-ST segment elevation myocardial infarction (NSTEMI). It is also cost-effective. It also reduces the emergency boarding time and may reduce the number of unnecessary admissions in healthcare facilities.

10.
Curr Heart Fail Rep ; 2024 Sep 10.
Article in English | MEDLINE | ID: mdl-39254897

ABSTRACT

PURPOSE OF THE REVIEW: Elevated troponin levels are well established e.g., for the diagnosis of suspected acute coronary syndrome in symptomatic patients. In contrast, troponin elevations in asymptomatic cancer patients emerge as a complex phenomenon, challenging traditional perceptions of its association solely with cardiac events. RECENT FINDINGS: Recent data support the predictive value of cardiac biomarker for all-cause mortality and cardiotoxicity in cancer patients. This review gives an overview about the current literature about cardiac troponins in prediction and identification of high-risk cancer patients. The overview is focusing on diagnostic challenges, biomarker significance, and gaps of knowledge. Latest publications highlight the relevance of cardiac troponin in risk analysis before cancer treatment as well as a potential diagnostic gatekeeper for further cardiological diagnostics and therapy.

11.
Rev Cardiovasc Med ; 25(8): 302, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39228492

ABSTRACT

Acute coronary syndrome (ACS) is associated with high mortality rates. Although the goal was to achieve a missed diagnosis rate of < 1%, the actual data showed a rate of > 2%. Chest pain diagnosis has remained unchanged over the years and is based on medical interviews and electrocardiograms (ECG), with biomarkers playing complementary roles. We aimed to summarize the key points of medical interviews, ECG clinics, use of biomarkers, and clinical scores, identify problems, and provide directions for future research. Medical interviews should focus on the character and location of chest pain (is it accompanied by radiating pain?) and the duration, induction, and ameliorating factors. An ECG should be recorded within 10 minutes of the presentation. The serial performance of an ECG is recommended for emergency department (ED) evaluation of suspected ACS. Characteristic ECG traces, such as Wellens syndrome and De Winter T-waves, should be understood. Therefore, troponin levels in all patients with suspected ischemic heart disease should be examined using a highly sensitive assay system. Depending on the ED facility, the patient should be risk stratified by serial measurements of cardiac troponin levels (re-testing at one hour would be preferred) to determine the appropriate time to perform an invasive strategy for a definitive diagnosis. The diagnostics should be based on Bayes' theorem; however, care should be taken to avoid the influence of heuristic bias.

12.
Clin Chem Lab Med ; 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39239902

ABSTRACT

OBJECTIVES: The objective of this study is to evaluate the analytical and diagnostic performance of a high-sensitivity point-of-care (POC) cardiac troponin I assay, the Quidel TriageTrue™ (QuidelOrtho Inc, San Diego, USA), compared to central laboratory testing (CLT) in accelerated diagnostic protocols (ADP) in real time in a clinical environment. METHODS: In a nested sub-study of a pragmatic randomised control trial, consecutive patients with suspected acute coronary syndrome (ACS) and chest pain <12 h duration were randomised to the ESC 0/1 and 0/3-h ADP. Subjects underwent sampling for Quidel TriageTrue POC hs-TnI whole blood and plasma, CLT hs-TnT Roche Elecsys and a validated, NICE approved CLT High sensitivity cardiac troponin I (hs-TnI) (Siemens Attellica) at each time point. Assay imprecision was assessed by repeat analysis of whole blood samples at three levels (low, near 10 % CV 5-10 ng/L, medium, approximating 99th percentile 15-25 ng/L and high, 3-5 times the 99th percentile, 60-100 ng/L). Final diagnosis was adjudicated at 6 weeks by Roche hs-TnT using the 4th universal definition of myocardial infarction (MI). RESULTS: A total of 1,157 patients consented and had both investigational POC whole blood and plasma and central lab hs-cTn available. The median age was 59, 47.2 % were female and 15 % had suffered a previous MI. Assay imprecision of whole blood POC TriageTrue revealed 10 % CV at 8.6 ng/L (>50 % lower than 99th percentile [20.5 ng/L]) and a 20 % CV at 1.2 ng/L. Receiver operator characteristics (ROC) curves were computed for each assay against adjudicated index type 1 MI to study clinical performance. At all-time points there were excellent performance for whole blood POC TriageTrue: area under the curve (AUC) 0.97 [95 % CI 0.94-098], 0.98 [95 % CI 0.97-1.00] and 0.95 [95 % CI 0.92-0.98] at time 0, 1 and 3 h respectively. There was statistical equivalence for performance of whole blood and plasma POC TriageTrue hs-TnI and laboratory Siemens Atellica hs-TnI. CONCLUSIONS: The whole blood POC TriageTrue hs-TnI assay demonstrates imprecision levels consistent with high sensitivity characteristics and has a clinical performance equivalent to an established, validated and NICE approved laboratory Siemens Atellica hs-TnI.

13.
Circulation ; 2024 Sep 10.
Article in English | MEDLINE | ID: mdl-39253802

ABSTRACT

BACKGROUND: Cardiac troponin (cTn) is key in diagnosing myocardial infarction (MI). After MI, the clinically observed half-life of cTn has been reported to be 7 to 20 hours, but this estimate reflects the combined elimination and simultaneous release of cTn from cardiomyocytes. More precise timing of myocardial injuries necessitates separation of these 2 components. We used a novel method for determination of isolated cTn elimination kinetics in humans. METHODS: Patients with MI were included within 24 hours after revascularization and underwent plasmapheresis to obtain plasma with a high cTn concentration. After at least 3 weeks, patients returned for an autologous plasma retransfusion followed by blood sampling for 8 hours. cTn was measured with 5 different high-sensitivity cTn assays. RESULTS: Of 25 included patients, 20 participants (mean age, 64.5 years; SD, 8.2 years; 4 women [20%]) received a retransfusion after a median of 5.8 weeks (interquartile range, 5.0-6.9 weeks) after MI. After retransfusion of a median of 620 mL (range, 180-679 mL) autologous plasma, the concentration of cTn in participants' blood increased 4 to 445 times above the upper reference level of the 5 high-sensitivity cTn assays. The median elimination half-life ranged from 134.1 minutes (95% CI, 117.8-168.0) for the Elecsys high-sensitivity cTnT assay to 239.7 minutes (95% CI, 153.7-295.1) for the Vitros high-sensitivity cTnI assay. The median clearance of cTnI ranged from 40.3 mL/min (95% CI, 32.0-44.9) to 52.7 mL/min (95% CI, 42.2-57.8). The clearance of cTnT was 77.0 mL/min (95% CI, 45.2-95.0). CONCLUSIONS: This novel method showed that the elimination half-life of cTnI and cTnT was 5 to 16 hours shorter than previously reported. This indicates a considerably longer duration of cardiomyocyte cTn release after MI than previously thought. Improved knowledge of timing of myocardial injury may call for changes in the management of MI and other disorders with myocardial injury.

14.
Int J Cardiol ; : 132556, 2024 Sep 11.
Article in English | MEDLINE | ID: mdl-39270942

ABSTRACT

INTRODUCTION: High-sensitivity cardiac troponin (hs-cTn) is a key biomarker for myocardial injury, yet its prognostic value in intensive cardiovascular care units (ICCU) remains poorly understood. We aimed to assess the association between peak hs-cTn levels and prognosis in ICCU patients. METHODS: All patients admitted to a tertiary care center ICCU between July 2019 - July 2023 were prospectively enrolled. Patients were divided into five groups according to their peak hs-cTnI levels: A) hs-cTnI <100 ng/L; B) hs-cTnI of 100-1000 ng/L; C) hs-cTnI of 1000-10,000 ng/L; D) hs-cTnI of 10,000-100,000 ng/L and E) hs-cTnI ≥100,000 ng/L. The primary outcome was all-cause mortality at one year. RESULTS: A total of 4149 patients (1273 females [30.7 %]) with a median age of 69 (IQR 58-79) were included. Group E was highly specific for myocardial infarction (97.4 %) and especially for ST segment elevation myocardial infarction (STEMI) (87.5 %). Patients in group E were 56 % more likely to die at 1-year in an adjusted Cox model (95 % CI 1.09-2.23, p = 0.014) as compared with group A. Subgroup analyses revealed that among STEMI patients, higher peak hs-cTnI levels were not associated with higher mortality rate (HR 1.04, 95 % CI 0.4-2.72, p = 0.9), in contrast to patients with NSTEMI (HR 7.62, 95 % CI 1.97-29.6, p = 0.003). CONCLUSIONS: Peak hs-cTnI levels ≥100,000 ng/L were linked to higher one-year mortality, largely indicative of large myocardial infarctions. Notably, the association between elevated hs-cTnI levels and mortality differed between STEMI and NSTEMI patients, warranting further investigation.

15.
Cureus ; 16(8): e66230, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39238680

ABSTRACT

Congenital coronary artery anomalies are rare. The most common anomalous variation is Anomalous Left Circumflex Artery (ALCx) which is a congenital anomaly. ALCx usually originates from the right sinus of Valsalva or as a proximal branching of the Right Coronary Artery (RCA). The clinical presentation has a spectrum which varies from asymptomatic presentation to angina or myocardial infarction with no atherosclerotic lesion due to kinking/compression of the vessel to ST-segment elevation myocardial infarction (STEMI) due to atherosclerotic occlusion. A 45-year-old female with a past medical history of hypertension, hyperlipidemia, type 2 diabetes, tobacco abuse, and a history of ischemic stroke, presented to the hospital due to chest pain. Electrocardiogram revealed inferior ST-elevation myocardial infarction (STEMI) and the patient was taken to the catheterization lab. Angiography revealed 90% stenotic Left Circumflex Artery (LCx) which was anomalous, arising from the right coronary cusp, whereas other coronary arteries were diffusedly atherosclerotic. A drug-eluting stent was placed in the ALCx reducing the stenosis from 90% to 0% and the patient was discharged in a stable condition on dual antiplatelet therapy and statin with plans for possible coronary artery bypass graft due to multivessel disease (severe diffuse disease of LAD, 90% mid-RCA stenosis, 80% proximal RCA stenosis). The patient was eventually lost to follow-up. Typically, anomalous LCx originating from RCA is benign, but there are many cases where there is myocardial infarction or sudden cardiac death due to acute angle take-off at the origin site. This anatomical variation is more important during cardiac surgeries because during valve replacement surgeries, there are cases of ALCx compression resulting in myocardial infarction. Our patient developed STEMI secondary to atherosclerotic stenosis in anomalous LCx. Based on her diffuse atherosclerotic disease and risk factors, it is likely that her anomalous anatomy did not cause her atherosclerotic disease. Overall, clinicians should remain vigilant for these anatomic abnormalities in their practice.

16.
Indian J Crit Care Med ; 28(8): 748-752, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39239175

ABSTRACT

Background: The History, Electrocardiogram, Age, Risk factors, and Troponin I (HEART) score is a simple method to risk stratify patients with chest pain according to the risk for incidence of major adverse cardiac events (MACEs). Materials and methods: A 202-patient prospective, single center study at Sri Siddhartha Medical College, Tumkur. Patients included were those who were presented to the emergency department (ED) due to non-traumatic chest pain, irrespective of age or any previous medical treatments, and were later referred to the cardiac care unit (CCU), cardiology department (CD). The end point of the study was the incidence of MACE. Results: There was a high occurrence of endpoint-myocardial infarction (MI) as MACE among patients with a high-risk HEART score (p < 0.001). About 52 patients (81.3%) who had MI had a high-risk score and 2 patients (3.1%) who had an endpoint of MI had a low-risk score. Sensitivity of HEART score to anticipate MACE was 91%, and the specificity was 80%. Conclusions: Our prospective study demonstrates the high sensitivity of the HEART score to effectively risk stratify patients and project the phenomenon of MACE. We support the use of the HEART score as a fast and accurate risk stratification tool in the ED. How to cite this article: Anwar I, Sony D. HEART Score: Prospective Evaluation of Its Accuracy and Applicability. Indian J Crit Care Med 2024;28(8):748-752.

18.
Acad Emerg Med ; 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39223791

ABSTRACT

BACKGROUND: Data comparing the performance of sex-specific to overall (non-sex-specific) high-sensitivity cardiac troponin (hs-cTn) cut-points for diagnosing acute coronary syndrome (ACS) are limited. This study aims to compare the safety and efficacy of sex-specific versus overall 99th percentile high-sensitivity cardiac troponin T (hs-cTnT) cut-points. METHODS: We conducted a secondary analysis of the STOP-CP cohort, which prospectively enrolled emergency department patients ≥ 21 years old with symptoms suggestive of ACS without ST-elevation on initial electrocardiogram across eight U.S. sites (January 25, 2017-September 6, 2018). Participants with both 0- and 1-h hs-cTnT measures less than or equal to the 99th percentile (sex-specific 22 ng/L for males, 14 ng/L for females; overall 19 ng/L) were classified into the rule-out group. The safety outcome was adjudicated cardiac death or myocardial infarction (MI) at 30 days. Efficacy was defined as the proportion classified to the rule-out group. McNemar's test and a generalized score statistic were used to compare rule-out and 30-day cardiac death or MI rates between strategies. Net reclassification improvement (NRI) index was used to further compare performance. RESULTS: This analysis included 1430 patients, of whom 45.8% (655/1430) were female; the mean ± SD age was 57.6 ± 12.8 years. At 30 days, cardiac death or MI occurred in 12.8% (183/1430). The rule-out rate was lower using sex-specific versus overall cut-points (70.6% [1010/1430] vs. 72.5% [1037/1430]; p = 0.003). Among rule-out patients, the 30-day cardiac death or MI rates were similar for sex-specific (2.4% [24/1010]) vs. overall (2.3% [24/1037]) strategies (p = 0.79). Among patients with cardiac death or MI, sex-specific versus overall cut-points correctly reclassified three females and incorrectly reclassified three males. The sex-specific strategy resulted in a net of 27 patients being incorrectly reclassified into the rule-in group. This led to an NRI of -2.2% (95% CI -5.1% to 0.8%). CONCLUSIONS: Sex-specific hs-cTnT cut-points resulted in fewer patients being ruled out without an improvement in safety compared to the overall cut-point strategy.

19.
Biomarkers ; : 1-8, 2024 Sep 13.
Article in English | MEDLINE | ID: mdl-39234754

ABSTRACT

BACKGROUND: In Egypt, aluminum phosphide (ALP) is a known lethal poison due to its cardiotoxicity. This study aimed to evaluate the predictive ability of N-terminal pro-B-type natriuretic peptide (NT-proBNP) for mortality in ALP-poisoned patients. METHODS: This prospective study was conducted on patients with ALP poisoning admitted to the Poison Control Center Ain Shams University Hospitals between July and December 2022. Upon admission, all patients were followed up and had their levels of NT-proBNP, troponin I (cTnI), and creatine kinase myocardial band (CK-MB) analyzed. RESULTS: Thirty patients were enrolled in the study and were divided into survivors and non-survivors. The initial NT-proBNP levels were significantly higher among non-survivors in contrast to the initial cTnI and CK-MB levels. The study identified that the best cutoff point of NT-proBNP for predicting mortality was ≥72 pg/ml, with AUC (0.869). CONCLUSION: It can be concluded that NT-proBNP can serve as an early predictor of mortality in ALP poisoning.

20.
J Am Heart Assoc ; : e034850, 2024 Sep 09.
Article in English | MEDLINE | ID: mdl-39248254

ABSTRACT

BACKGROUND: Higher cardiac troponin is associated with worse outcomes in patients with acute heart failure. The significance of repeat measurements over hours remains unclear. We assessed whether a repeat measurement and the Δ between measurements of high-sensitivity cardiac troponin I (hs-cTnI) were associated with outcomes in hypervolemic patients with acute heart failure without acute coronary syndrome. METHODS AND RESULTS: We analyzed 582 individuals from AKINESIS (Acute Kidney Injury Neutrophil Gelatinase-Associated Lipocalin Evaluation of Symptomatic Heart Failure Study) with hs-cTnI measured ≤12 hours from admission and repeated ≤6 hours thereafter. Associations between hs-cTnI levels and their Δ with short-term (death, intensive care unit admission, receipt of inotropes, or positive pressure ventilation during hospitalization) and long-term (death or heart failure readmission within 1 year) outcomes were assessed. The average age was 69±13 years, 62% were men, 65% were White, 46% had coronary artery disease, and 22% had chest pain. Median hs-cTnI levels were 27 (interquartile range [IQR], 13-62) ng/L initially and 28 (IQR, 14-68) ng/L subsequently, with a Δ of 0 [IQR, -2 to 4] ng/L over 3.4±1 hours. Only the second measurement was associated with short-term outcomes (odds ratio, 1.14 per 2-fold higher [95% CI, 1.02-1.28]). Both individual measurements and the Δ were associated with long-term outcomes (hazard ratios, 1.09, 1.12, and 1.16 for first, second, and Δ, respectively). Associated risk for the first and second measurements were not constant over the year but highest early after being measured and decreased over 1 year. CONCLUSIONS: Repeat measurements of hs-cTnI over hours can identify individuals with acute heart failure without acute coronary syndrome at risk for short- and long-term outcomes.

SELECTION OF CITATIONS
SEARCH DETAIL