1.
Bone ; 181: 117031, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38311304

ABSTRACT

INTRODUCTION: Conventional bone imaging methods primarily use X-ray techniques to assess bone mineral density (BMD), focusing exclusively on the mineral phase. This approach lacks information about the organic phase and bone water content, resulting in an incomplete evaluation of bone health. Recent research highlights the potential of ultrashort echo time magnetic resonance imaging (UTE MRI) to measure cortical porosity and estimate BMD based on signal intensity. UTE MRI also provides insights into bone water distribution and matrix organization, enabling a comprehensive bone assessment with a single imaging technique. Our study aimed to establish quantifiable UTE MRI-based biomarkers at clinical field strength to estimate BMD and microarchitecture while quantifying bound water content and matrix organization. METHODS: Femoral bones from 11 cadaveric specimens (n = 4 males 67-92 yrs of age, n = 7 females 70-95 yrs of age) underwent dual-echo UTE MRI (3.0 T, 0.45 mm resolution) with different echo times and high resolution peripheral quantitative computed tomography (HR-pQCT) imaging (60.7 µm voxel size). Following registration, a 4.5 mm HR-pQCT region of interest was divided into four quadrants and used across the multi-modal images. Statistical analysis involved Pearson correlation between UTE MRI porosity index and a signal-intensity technique used to estimate BMD with corresponding HR-pQCT measures. UTE MRI was used to calculate T1 relaxation time and a novel bound water index (BWI), compared across subregions using repeated measures ANOVA. RESULTS: The UTE MRI-derived porosity index and signal-intensity-based estimated BMD correlated with the HR-pQCT variables (porosity: r = 0.73, p = 0.006; BMD: r = 0.79, p = 0.002). However, these correlations varied in strength when we examined each of the four quadrants (subregions, r = 0.11-0.71). T1 relaxometry and the BWI exhibited variations across the four subregions, though these differences were not statistically significant. Notably, we observed a strong negative correlation between T1 relaxation time and the BWI (r = -0.87, p = 0.0006). CONCLUSION: UTE MRI shows promise for being an innocuous method for estimating cortical porosity and BMD parameters while also giving insight into bone hydration and matrix organization. This method offers the potential to equip clinicians with a more comprehensive array of imaging biomarkers to assess bone health without the need for invasive or ionizing procedures.


Subject(s)
Cortical Bone , Magnetic Resonance Imaging , Male , Female , Humans , Child , Feasibility Studies , X-Ray Microtomography , Cortical Bone/diagnostic imaging , Magnetic Resonance Imaging/methods , Water
2.
Quant Imaging Med Surg ; 13(10): 6942-6951, 2023 Oct 01.
Article in English | MEDLINE | ID: mdl-37869338

ABSTRACT

Background: The effect of dehydration of ex vivo cartilage samples and rehydration with native synovial fluid or normal saline on quantitative ultrashort echo time (UTE) biomarkers are unknown. We aimed to investigate the effect of cartilage dehydration-rehydration on UTE biomarkers and to compare the rehydration capabilities of native synovial fluid and normal saline. Methods: A total of 37 cartilage samples were harvested from patients (n=5) who underwent total knee replacement. Fresh cartilage samples were exposed to air to dehydrate for 2 hours after baseline magnetic resonance (MR) scanning, then randomly divided into two groups: one soaking in native synovial fluid (n=17) and the other in normal saline (n=20) to rehydrate for 4 hours. UTE-based biomarkers [T1, adiabatic T1r (AdiabT1r), macromolecular fraction (MMF), magnetization transfer ratio (MTR), and T2*] and sample weights were evaluated for fresh, dehydrated, and rehydrated cartilage samples. Differences and agreements between groups were assessed using the values of fresh cartilage samples as reference standard. Results: Dehydrating in air for 2 hours resulted in significant weight loss (P=0.000). T1, AdiabT1r, and T2* decreased significantly while MMF and MTR increased significantly (all P<0.02). Non-significant differences were observed in cartilage weights after rehydrating in both synovial fluid and normal saline, with P values being 0.204 and 0.769, respectively. There were no significant differences in T1, AdiabT1r, MMF, and MTR after rehydrating in synovial fluid (P>0.0167, with Bonferroni correction) while T2* (P=0.001) still had significant differences compared with fresh samples. However, no significant differences were detected for any of the evaluated UTE biomarkers after rehydrating in normal saline (all P>0.05). No differences were detected in the agreement of UTE biomarker measurements between fresh samples and samples rehydrated with synovial fluid and normal saline. Conclusions: Cartilage dehydration resulted in significant changes in UTE biomarkers. Rehydrating with synovial fluid or normal saline had non-significant effect on all the evaluated UTE biomarkers except T2* values, which still had significant differences compared with fresh samples after rehydrating with synovial fluid. No significant difference was observed in the rehydration capabilities of native synovial fluid and normal saline.

3.
J Appl Physiol (1985) ; 133(4): 893-901, 2022 10 01.
Article in English | MEDLINE | ID: mdl-36049059

ABSTRACT

Tracheomalacia is an airway condition in which the trachea excessively collapses during breathing. Neonates diagnosed with tracheomalacia require more energy to breathe, and the effect of tracheomalacia can be quantified by assessing flow-resistive work of breathing (WOB) in the trachea using computational fluid dynamics (CFD) modeling of the airway. However, CFD simulations are computationally expensive; the ability to instead predict WOB based on more straightforward measures would provide a clinically useful estimate of tracheal disease severity. The objective of this study is to quantify the WOB in the trachea using CFD and identify simple airway and/or clinical parameters that directly relate to WOB. This study included 30 neonatal intensive care unit subjects (15 with tracheomalacia and 15 without tracheomalacia). All subjects were imaged using ultrashort echo time (UTE) MRI. CFD simulations were performed using patient-specific data obtained from MRI (airway anatomy, dynamic motion, and airflow rates) to calculate the WOB in the trachea. Several airway and clinical measurements were obtained and compared with the tracheal resistive WOB. The maximum percent change in the tracheal cross-sectional area (ρ = 0.560, P = 0.001), average glottis cross-sectional area (ρ = -0.488, P = 0.006), minute ventilation (ρ = 0.613, P < 0.001), and lung tidal volume (ρ = 0.599, P < 0.001) had significant correlations with WOB. A multivariable regression model with three independent variables (minute ventilation, average glottis cross-sectional area, and minimum of the eccentricity index of the trachea) can be used to estimate WOB more accurately (R2 = 0.726). This statistical model may allow clinicians to estimate tracheal resistive WOB based on airway images and clinical data.NEW & NOTEWORTHY The work of breathing due to resistance in the trachea is an important metric for quantifying the effect of tracheal abnormalities such as tracheomalacia, but currently requires complex dynamic imaging and computational fluid dynamics simulation to calculate it. This study produces a method to predict the tracheal work of breathing based on readily available imaging and clinical metrics.


Subject(s)
Tracheomalacia , Work of Breathing , Humans , Infant, Newborn , Lung/diagnostic imaging , Tidal Volume , Trachea/diagnostic imaging , Tracheomalacia/diagnostic imaging
4.
Quant Imaging Med Surg ; 12(8): 4176-4189, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35919053

ABSTRACT

Background: We aimed to evaluate the image quality, feasibility, and diagnostic performance of three-dimensional ultrashort echo time magnetic resonance imaging (3D UTE-MRI) to assess idiopathic pulmonary fibrosis (IPF) compared with high-resolution computed tomography (HRCT) and half-Fourier single-shot turbo spin-echo (HASTE) MRI. Methods: A total of 36 patients with IPF (34 men; mean age: 62±8 years, age range: 43 to 78 years) were prospectively included and underwent HRCT and chest MRI on the same day. Chest MRI was performed with a free-breathing 3D spiral UTE pulse sequence and HASTE sequence on a 1.5 T MRI. Two radiologists independently evaluated the image quality of the HRCT, HASTE, and 3D UTE-MRI. They assessed the representative imaging features of IPF, including honeycombing, reticulation, traction bronchiectasis, and ground-glass opacities. Image quality of the 3D UTE-MRI, HASTE, and HRCT were assessed using a 5-point visual scoring method. Kappa and weighted kappa analysis were used to measure intra- and inter-observer and inter-method agreements. Sensitivity (SE), specificity (SP), and accuracy (AC) were used to assess the performance of 3D UTE-MRI for detecting image features of IPF and monitoring the extent of pulmonary fibrosis. Linear regressions and Bland-Altman plots were generated to assess the correlation and agreement between the assessment of the extent of pulmonary fibrosis made by the 2 observers. Results: The image quality of HRCT was higher than that of HASTE and UTE-MRI (HRCT vs. UTE-MRI vs. HASTE: 4.9±0.3 vs. 4.1±0.7 vs. 3.0±0.3; P<0.001). Interobserver agreement of HRCT, HASTE, and 3D UTE-MRI when assessing pulmonary fibrosis was substantial and excellent (HRCT: 0.727≤ κ ≤1, P<0.001; HASTE: 0.654≤ κ ≤1, P<0.001; 3D UTE-MRI: 0.719≤ κ ≤0.824, P<0.001). In addition, reticulation (SE: 97.1%; SP: 100%; AC: 97.2%; κ =0.654), honeycombing (SE: 83.3%; SP: 100%; AC: 86.1%; κ =0.625) patterns, and traction bronchiectasis (SE: 94.1%; SP: 100%; AC: 94.4%, κ =0.640) were also well-visualized on 3D UTE-MRI, which was significantly superior to HASTE. Compared with HRCT, the sensitivity of 3D UTE-MRI to detect signs of pulmonary fibrosis (n=35) was 97.2%. The interobserver agreement in elevation of the extent of pulmonary fibrosis with HRCT and 3D UTE-MRI was R2=0.84 (P<0.001) and R2=0.84 (P<0.001), respectively. The extent of pulmonary fibrosis assessed with 3D UTE-MRI [median =9, interquartile range (IQR): 6.25 to 10.00] was lower than that from HRCT (median =12, IQR: 9.25 to 13.00; U=320.00, P<0.001); however, they had a positive correlation (R=0.72, P<0.001). Conclusions: As a radiation-free non-contrast enhanced imaging method, although the image quality of 3D UTE-MRI is inferior to that of HRCT, it has high reproducibility to identify the imaging features of IPF and evaluate the extent of pulmonary fibrosis.

5.
Ann Am Thorac Soc ; 17(10): 1247-1256, 2020 10.
Article in English | MEDLINE | ID: mdl-32579852

ABSTRACT

Rationale: Dynamic collapse of the tracheal lumen (tracheomalacia) occurs frequently in premature neonates, particularly in those with common comorbidities such as bronchopulmonary dysplasia. The tracheal collapse increases the effort necessary to breathe (work of breathing [WOB]). However, quantifying the increased WOB related to tracheomalacia has previously not been possible. Therefore, it is also not currently possible to separate the impact of tracheomalacia on patient symptoms from parenchymal abnormalities.Objectives: To measure the increase in WOB due to airway motion in individual subjects with and without tracheomalacia and with different types of respiratory support.Methods: Fourteen neonatal intensive care unit subjects not using invasive mechanical ventilation were recruited. In eight, tracheomalacia was diagnosed via clinical bronchoscopy, and six did not have tracheomalacia. Self-gated three-dimensional ultrashort-echo-time magnetic resonance imaging (MRI) was performed on each subject with clinically indicated respiratory support to obtain cine images of tracheal anatomy and motion during the respiratory cycle. The component of WOB due to resistance within the trachea was then calculated via computational fluid dynamics (CFD) simulations of airflow on the basis of the subject's anatomy, motion, and respiratory airflow rates. A second CFD simulation was performed for each subject with the airway held static at its largest (i.e., most open) position to determine the increase in WOB due to airway motion and collapse.Results: The tracheal-resistive component of WOB was increased because of airway motion by an average of 337% ± 295% in subjects with tracheomalacia and 24% ± 14% in subjects without tracheomalacia (P < 0.02). In the tracheomalacia group, subjects who were treated with continuous positive airway pressure (CPAP) using a RAM cannula expended less energy for breathing compared with the subjects who were breathing room air or on a high-flow nasal cannula.Conclusions: Neonatal subjects with tracheomalacia have increased energy expenditure compared with neonates with normal airways, and CPAP may be able to attenuate the increase in respiratory work. Subjects with tracheomalacia expend more energy on the tracheal-resistive component of WOB alone than nontracheomalacia patients expend on the resistive WOB for the entire respiratory system, according to previously reported values. CFD may be able to provide an objective measure of treatment response for children with tracheomalacia.


Subject(s)
Tracheomalacia , Humans , Magnetic Resonance Imaging , Respiration , Trachea , Work of Breathing
6.
Pharmaceutics ; 11(12)2019 Dec 17.
Article in English | MEDLINE | ID: mdl-31861138

ABSTRACT

The theranostic approach to local tuberculosis treatment allows drug delivery and imaging of the lungs for a better control and personalization of antibiotic therapy. Metal-organic framework (MOF) Fe-MIL-101-NH2 nanoparticles were loaded with isoniazid. To optimize their functionality a 23 factorial design of spray-drying with poly(lactide-co-glycolide) and leucine was employed. Powder aerodynamic properties were assessed using a twin stage impinger based on the dose emitted and the fine particle fraction. Magnetic resonance imaging (MRI) contrast capabilities were tested on porous lung tissue phantom and ex vivo rat lungs. Cell viability and uptake studies were conducted on murine macrophages RAW 246.9. The final product showed good aerodynamic properties, modified drug release, easier uptake by macrophages in relation to raw isoniazid-MOF, and MRI contrast capabilities. Starting from raw MOF, a fully functional inhalable theranostic system with a potential application in personalized tuberculosis pulmonary therapy was developed.

7.
J Appl Physiol (1985) ; 126(4): 1138-1149, 2019 04 01.
Article in English | MEDLINE | ID: mdl-30730810

ABSTRACT

To longitudinally monitor progressive fibrosis in the transforming growth factor-α (TGF-α) transgenic mouse model of lung fibrosis, we used retrospective self-gating ultrashort echo time (UTE) magnetic resonance imaging (MRI) to image mouse lung at baseline and after 4 and 8 wk of fibrosis initiation via doxycycline administration. Only bitransgenic mice were used in this study and divided into two cohorts: six mice were fed doxycycline food to induce lung fibrosis (referred to as Dox cohort), and five other mice were fed normal food (referred to as control cohort). Lung mechanics, histology, and hydroxyproline were assessed after the final MRI. A linear mixed-effects model was used to analyze MRI-derived longitudinal lung-function parameters. Tidal volume decreased at a rate of -0.016 ± 0.002 ml/week [χ2(1) = 16.48, P < 0.001] for Dox cohort and increased at a rate of 0.010 ± 0.003 ml/week [χ2(1) = 6.37, P = 0.01] for control cohort. Minute ventilation decreased at a rate of -1.71 ± 0.26 ml·min-1·wk-1 [χ2(1) = 14.04, P < 0.001] for Dox cohort but did not change significantly over time for control cohort. High-density lung volume percentage increased at a rate of 3.9 ± 0.7%/wk for Dox cohort [χ2(1) = 11.47, P < 0.001] but did not change significantly over time for control cohort. MRI-derived lung structure and function parameters were strongly correlated with pleural thickness, hydroxyproline content, lung compliance, airway resistance, and airway elastance. We conclude that self-gating UTE MRI could be used to longitudinally monitor lung fibrosis in the TGF-α transgenic mouse model. NEW & NOTEWORTHY Self-gating UTE MRI was used to monitor morphology and physiology in lung fibrosis in a transforming growth factor-α transgenic mouse model. Tidal volume was shown for the first time to correlate strongly with conventional metrics of fibrosis such as hydroxyproline and pleural thickness.


Subject(s)
Lung/physiopathology , Pulmonary Fibrosis/physiopathology , Animals , Disease Models, Animal , Disease Progression , Female , Hydroxyproline/metabolism , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Longitudinal Studies , Lung/metabolism , Magnetic Resonance Imaging/methods , Male , Mice , Mice, Transgenic , Pulmonary Fibrosis/metabolism , Respiration , Respiratory Function Tests/methods , Retrospective Studies , Transforming Growth Factor alpha/metabolism