Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.884
Filter
1.
Nat Med ; 30(7): 2010-2019, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38951635

ABSTRACT

For centuries scientists and technologists have sought artificial leg replacements that fully capture the versatility of their intact biological counterparts. However, biological gait requires coordinated volitional and reflexive motor control by complex afferent and efferent neural interplay, making its neuroprosthetic emulation challenging after limb amputation. Here we hypothesize that continuous neural control of a bionic limb can restore biomimetic gait after below-knee amputation when residual muscle afferents are augmented. To test this hypothesis, we present a neuroprosthetic interface consisting of surgically connected, agonist-antagonist muscles including muscle-sensing electrodes. In a cohort of seven leg amputees, the interface is shown to augment residual muscle afferents by 18% of biologically intact values. Compared with a matched amputee cohort without the afferent augmentation, the maximum neuroprosthetic walking speed is increased by 41%, enabling equivalent peak speeds to persons without leg amputation. Further, this level of afferent augmentation enables biomimetic adaptation to various walking speeds and real-world environments, including slopes, stairs and obstructed pathways. Our results suggest that even a small augmentation of residual muscle afferents restores biomimetic gait under continuous neuromodulation in individuals with leg amputation.


Subject(s)
Amputation, Surgical , Amputees , Artificial Limbs , Biomimetics , Bionics , Gait , Humans , Gait/physiology , Biomimetics/methods , Male , Middle Aged , Adult , Female , Muscle, Skeletal/innervation , Walking , Leg/surgery
2.
Sci Data ; 11(1): 806, 2024 Jul 20.
Article in English | MEDLINE | ID: mdl-39033239

ABSTRACT

Lower limb amputation is a medical intervention which causes motor disability and may compromise quality of life. Several factors determine patients' health outcomes, including an appropriate prosthetic provision and an effective rehabilitation program, necessitating a thorough quantitative observation through different data sources. In this context, the role of interoperability becomes essential, facilitating the reuse of real-world data through the provision of structured and easily accessible databases. This study introduces a comprehensive 10-year dataset encompassing clinical features, mobility measurements, and prosthetic knees of 1006 trans-femoral amputees during 1962 hospital stays for rehabilitation. The dataset is made available in both comma-separated values (CSV) format and HL7 Fast Healthcare Interoperability Resources (FHIR)-based representation, ensuring broad utility and compatibility for researchers and healthcare practitioners. This initiative contributes to advancing community understanding of post-amputation rehabilitation and underscores the significance of interoperability in promoting seamless data sharing for meaningful insights into healthcare outcomes.


Subject(s)
Amputation, Surgical , Humans , Amputation, Surgical/rehabilitation , Artificial Limbs , Amputees/rehabilitation , Femur/surgery , Data Collection
3.
Article in English | MEDLINE | ID: mdl-38980789

ABSTRACT

Transfemoral amputation is a debilitating condition that leads to long-term mobility restriction and secondary disorders that negatively affect the quality of life of millions of individuals worldwide. Currently available prostheses are not able to restore energetically efficient and functional gait, thus, recently, the alternative strategy to inject energy at the residual hip has been proposed to compensate for the lack of energy of the missing leg. Here, we show that a portable and powered hip exoskeleton assisting both the residual and intact limb induced a reduction of walking energy expenditure in four individuals with above-knee amputation. The reduction of the energy expenditure, quantified using the Physiological Cost Index, was in the range [-10, -17]% for all study participants compared to walking without assistance, and between [-2, -24]% in three out of four study participants compared to walking without the device. Additionally, all study participants were able to walk comfortably and confidently with the hip exoskeleton overground at both their self-selected comfortable and fast speed without any observable alterations in gait stability. The study findings confirm that injecting energy at the hip level is a promising approach for individuals with above-knee amputation. By reducing the energy expenditure of walking and facilitating gait, a hip exoskeleton may extend mobility and improve locomotor training of individuals with above-knee amputation, with several positive implications for their quality of life.


Subject(s)
Amputation, Surgical , Amputees , Artificial Limbs , Energy Metabolism , Exoskeleton Device , Hip , Walking , Humans , Walking/physiology , Male , Adult , Amputation, Surgical/rehabilitation , Amputees/rehabilitation , Middle Aged , Gait/physiology , Female , Biomechanical Phenomena , Prosthesis Design , Knee
4.
PLoS One ; 19(7): e0301619, 2024.
Article in English | MEDLINE | ID: mdl-38991031

ABSTRACT

Changes in limb volume and shape among transtibial amputees affects socket fit and comfort. The ability to accurately measure residual limb volume and shape and relate it to comfort could contribute to advances in socket design and overall care. This work designed and validated a novel 3D laser scanner that measures the volume and shape of residual limbs. The system was designed to provide accurate and repeatable scans, minimize scan duration, and account for limb motion during scans. The scanner was first validated using a cylindrical body with a known shape. Mean volumetric errors of 0.17% were found under static conditions, corresponding to a radial spatial resolution of 0.1 mm. Limb scans were also performed on a transtibial amputee and yielded a standard deviation of 8.1 ml (0.7%) across five scans, and a 46 ml (4%) change in limb volume when the socket was doffed after 15 minutes of standing.


Subject(s)
Amputees , Artificial Limbs , Lasers , Tibia , Humans , Tibia/surgery , Tibia/diagnostic imaging , Amputation Stumps/diagnostic imaging , Imaging, Three-Dimensional/methods , Prosthesis Design/methods , Male , Prosthesis Fitting/methods
5.
Appl Ergon ; 120: 104344, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38991493

ABSTRACT

Limb amputation can lead to significant functional challenges in daily activities, prompting amputees to use prosthetic devices (PDs). However, the cognitive demands of PDs and usability issues have resulted in user rejections. This study aimed to create a Human Performance Model for Upper-Limb Prosthetic Devices (HPM-UP). The model used formulations of learnability, error rate, memory load, efficiency, and satisfaction to assess usability. The model was validated in an experiment with 30 healthy participants using a bypass prosthetic device. Findings indicated that the HPM-UP successfully predicted the usability of prosthetic devices, aligning with human subject data. This research proposes a quantitative approach to predict upper limb prosthetic device usability by quantifying each dimension and computationally connecting them. The model, available on Github and executable with Rstudio, could enable clinicians to assess and analyze the human performance of various commercial prostheses, aiding in recommending optimal devices for patients.


Subject(s)
Amputees , Artificial Limbs , Prosthesis Design , Upper Extremity , Humans , Upper Extremity/surgery , Male , Female , Adult , Amputees/psychology , Young Adult
6.
PLoS One ; 19(7): e0307523, 2024.
Article in English | MEDLINE | ID: mdl-39042623

ABSTRACT

BACKGROUND: Little is known about which outcome domains characterise meaningful recovery following prosthetic rehabilitation and should be measured. Our previous qualitative work developed a conceptual model of outcome domains which are meaningful to patients. This qualitative synthesis aims to develop that model by exploring views and experiences of recovery captured in the limb loss literature, and use these to produce a second iteration of the model describing outcome domains of importance following prosthetic rehabilitation from the patient's perspective. METHODS: Systematic searches were conducted using CINAHL, Psychinfo and Web of Science from 2011 to early 2023. Studies with a qualitative design focusing on views and experiences of lower limb prosthetic users were eligible for inclusion. Quality was assessed using the CASP tool. 'Best Fit' framework synthesis was used to synthesise the evidence and develop the conceptual model. RESULTS: 40 studies were included, describing the experiences of 539 participants. Data supported the pre-existing conceptual model and led to development of four of the five domains. The newly named ECLIPSE model describes meaningful outcome domains as 1) Being able to participate in important activities and roles, 2) Participating in the way I want to, 3) My prosthesis works for me, 4) If I am in pain, I can manage it, and 5) I am able to accept my new normal. Studies came from 15 countries showing good coverage of high-income settings. Few participants from low-and-middle-income countries were included, it is unclear if the ECLIPSE model describes outcome domains of importance in these settings. CONCLUSIONS: This synthesis provides a rigorous foundation for understanding outcome domains of importance following lower limb prosthetic rehabilitation from the patient's perspective. The ECLIPSE model is an accessible representation of recovery which could direct rehabilitation programmes, as well as inform the evaluation of prosthetic care through the selection of outcome measures.


Subject(s)
Amputation, Surgical , Artificial Limbs , Lower Extremity , Humans , Amputation, Surgical/rehabilitation , Lower Extremity/surgery , Amputees/rehabilitation , Models, Theoretical
7.
Sensors (Basel) ; 24(14)2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39066140

ABSTRACT

BACKGROUND: The company Ethnocare has developed the Overlay, a new pneumatic solution for managing volumetric variations (VVs) of the residual limb (RL) in transtibial amputees (TTAs), which improves socket fitting. However, the impact of the Overlay during functional tasks and on the comfort and pain felt in the RL is unknown. METHODS: 8 TTAs participated in two evaluations, separated by two weeks. We measured compensatory strategies (CS) using spatio-temporal parameters and three-dimensional lower limb kinematics and kinetics during gait and sit-to-stand (STS) tasks. During each visit, the participant carried out our protocol while wearing the Overlay and prosthetic folds (PFs), the most common solution to VV. Between each task, comfort and pain felt were assessed using visual analog scales. RESULTS: While walking, the cadence with the Overlay was 105 steps/min, while it was 101 steps/min with PFs (p = 0.021). During 35% and 55% of the STS cycle, less hip flexion was observed while wearing the Overlay compared to PFs (p = 0.004). We found asymmetry coefficients of 13.9% with the Overlay and 17% with PFs during the STS (p = 0.016) task. Pain (p = 0.031), comfort (p = 0.017), and satisfaction (p = 0.041) were better with the Overlay during the second visit. CONCLUSION: The Overlay's impact is similar to PFs' but provides less pain and better comfort.


Subject(s)
Amputees , Artificial Limbs , Gait , Tibia , Humans , Male , Biomechanical Phenomena/physiology , Female , Middle Aged , Gait/physiology , Tibia/surgery , Tibia/physiology , Adult , Walking/physiology , Amputation, Surgical , Amputation Stumps/physiopathology , Aged , Prosthesis Design , Prosthesis Fitting/methods
8.
Article in English | MEDLINE | ID: mdl-39018213

ABSTRACT

Prosthetic hands have significant potential to restore the manipulative capabilities and self-confidence of amputees and enhance their quality of life. However, incompatibility between prosthetic devices and residual limbs can lead to secondary injuries such as skin pressure ulcers and restricted joint motion, contributing to a high prosthesis abandonment rate. To address these challenges, this study introduces a data-driven design framework (D3Frame) utilizing a multi-index optimization method. By incorporating motion/ pressure data, as well as clinical criteria such as pain threshold/ tolerance, from various anatomical sites on the residual limbs of amputees, this framework aims to optimize the structural design of the prosthetic socket, including the Antecubital Channel (AC), Lateral Epicondylar Region Contour (LC), Medial Epicondylar Region Contour (MC), Olecranon Region Contour (OC), Lateral Flexor/ Extensor Region (LR), and Medial Flexor/ Extensor Region (MR). Experiments on five forearm amputees verified the improved adaptability of the optimized socket compared to traditional sockets under three load conditions. The experimental results revealed a modest score enhancement on standard clinical scales and reduced muscle fatigue levels. Specifically, the percent effort of muscles and slope value of mean/ median frequency decreased by 19%, 70%, and 99% on average, respectively, and the average values of mean/ median frequency in the motion cycle both increased by approximately 5%. The proposed D3Frame in this study was applied to optimize the structural aspects of designated regions of the prosthetic socket, offering the potential to aid prosthetists in prosthesis design and, consequently, augmenting the adaptability of prosthetic devices.


Subject(s)
Amputees , Artificial Limbs , Hand , Prosthesis Design , Humans , Amputees/rehabilitation , Male , Adult , Algorithms , Middle Aged , Amputation Stumps/physiopathology , Female
9.
JBJS Rev ; 12(7)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38968369

ABSTRACT

¼ The purpose of this article was to review the multidisciplinary, team-based approach necessary for the optimal management of patients with limb loss undergoing osseointegration surgery.¼ In this study, we describe the interdisciplinary process of screening, counseling, and surgical and rehabilitation considerations with an emphasis on principles rather than specific implants or techniques.¼ Integrated perioperative management and long-term surveillance are crucial to ensure the best possible outcomes.¼ We hope this model will service as an implant-agnostic guide to others seeking to development an osseointegration center of excellence.


Subject(s)
Amputation, Surgical , Osseointegration , Humans , Amputation, Surgical/rehabilitation , Patient Care Team , Artificial Limbs
10.
Sci Rep ; 14(1): 16521, 2024 07 17.
Article in English | MEDLINE | ID: mdl-39019986

ABSTRACT

Ankle push-off power plays an important role in healthy walking, contributing to center-of-mass acceleration, swing leg dynamics, and accounting for 45% of total leg power. The majority of existing passive energy storage and return prostheses for people with below-knee (transtibial) amputation are stiffer than the biological ankle, particularly at slower walking speeds. Additionally, passive devices provide insufficient levels of energy return and push-off power, negatively impacting biomechanics of gait. Here, we present a clinical study evaluating the kinematics and kinetics of walking with a microprocessor-controlled, variable-stiffness ankle-foot prosthesis (945 g) compared to a standard low-mass passive prosthesis (Ottobock Taleo, 463 g) with 7 study participants having unilateral transtibial amputation. By modulating prosthesis stiffness under computer control across walking speeds, we demonstrate that there exists a stiffness that increases prosthetic-side energy return, peak power, and center-of-mass push-off work, and decreases contralateral limb peak ground reaction force compared to the standard passive prosthesis across all evaluated walking speeds. We demonstrate a significant increase in center-of-mass push-off work of 26.1%, 26.2%, 29.6% and 29.9% at 0.75 m/s, 1.0 m/s, 1.25 m/s, and 1.5 m/s, respectively, and a significant decrease in contralateral limb ground reaction force of 3.1%, 3.9%, and 3.2% at 1.0 m/s, 1.25 m/s, and 1.5 m/s, respectively. This study demonstrates the potential for a quasi-passive microprocessor-controlled variable-stiffness prosthesis to increase push-off power and energy return during gait at a range of walking speeds compared to a passive device of a fixed stiffness.


Subject(s)
Artificial Limbs , Prosthesis Design , Walking , Humans , Biomechanical Phenomena , Male , Female , Walking/physiology , Adult , Middle Aged , Walking Speed/physiology , Gait/physiology , Amputees/rehabilitation
11.
J Neuroeng Rehabil ; 21(1): 119, 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39003459

ABSTRACT

The ankle-foot prosthesis aims to compensate for the missing motor functions by fitting the motion characteristics of the human ankle, which contributes to enabling the lower-limb amputees to take care of themselves and improve mobility in daily life. To address the problems of poor bionic motion of the ankle-foot prosthesis and the lack of natural interaction among the patient, prosthesis, and the environment, we developed a complex reverse-rolling conjugate joint based on the human ankle-foot structure and motion characteristics, the rolling joint was used to simulate the rolling-sliding characteristics of the knee joint. Meanwhile, we established a segmental dynamics model of the prosthesis in the stance phase, and the prosthetic structure parameters were obtained with the optimal prosthetic structure dimensions and driving force. In addition, a carbon fiber energy-storage foot was designed based on the human foot profile, and the dynamic response of its elastic strain energy at different thicknesses was simulated and analyzed. Finally, we integrated a bionic ankle-foot prosthesis and experiments were conducted to verify the bionic nature of the prosthetic joint motion and the energy-storage characteristics of the carbon fiber prosthetic foot. The proposed ankle-foot prosthesis provides ambulation support to assist amputees in returning to social life normally and has the potential to help improve clinical viability to reduce medical rehabilitation costs.


Subject(s)
Ankle , Artificial Limbs , Bionics , Foot , Prosthesis Design , Humans , Ankle/physiology , Foot/physiology , Amputees/rehabilitation , Ankle Joint/physiology , Biomechanical Phenomena
12.
J Neuroeng Rehabil ; 21(1): 117, 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39003469

ABSTRACT

BACKGROUND: Falls due to stumbling are prevalent for transfemoral prosthesis users and may lead to increased injury risk. This preliminary case series analyzes the transfemoral prosthesis user stumble recovery response to highlight key deficits in current commercially-available prostheses and proposes potential interventions to improve recovery outcomes. METHODS: Six transfemoral prosthesis users were perturbed on their prosthetic limb at least three times while walking on a treadmill using obstacle perturbations in early, mid and late swing. Kinematic data were collected to characterize the response, while fall rate and key kinematic recovery metrics were used to assess the quality of recovery and highlight functional deficits in current commercially-available prostheses. RESULTS: Across all participants, 13 (54%) of the 24 trials resulted in a fall (defined as > 50% body-weight support) with all but one participant (83%) falling at least once and two participants (33%) falling every time. In contrast, in a previous study of seven young, unimpaired, non-prosthesis users using the same experimental apparatus, no falls occurred across 190 trials. For the transfemoral prosthesis users, early swing had the highest rate of falling at 64%, followed by mid-swing at 57%, and then late swing at 33%. The trend in falls was mirrored by the kinematic recovery metrics (peak trunk angle, peak trunk angular velocity, forward reach of the perturbed limb, and knee angle at ground contact). In early swing all four metrics were deficient compared to non-prosthesis user controls. In mid swing, all but trunk angular velocity were deficient. In late swing only forward reach was deficient. CONCLUSION: Based on the stumble recovery responses, four potential deficiencies were identified in the response of the knee prostheses: (1) insufficient resistance to stance knee flexion upon ground contact; (2) insufficient swing extension after a perturbation; (3) difficulty initiating swing flexion following a perturbation; and (4) excessive impedance against swing flexion in early swing preventing the potential utilization of the elevating strategy. Each of these issues can potentially be addressed by mechanical or mechatronic changes to prosthetic design to improve quality of recovery and reduce the likelihood a fall.


Subject(s)
Accidental Falls , Artificial Limbs , Humans , Accidental Falls/prevention & control , Artificial Limbs/adverse effects , Male , Female , Biomechanical Phenomena , Adult , Middle Aged , Walking/physiology , Femur/physiology , Amputees/rehabilitation , Gait/physiology
13.
Biomed Mater Eng ; 35(4): 401-414, 2024.
Article in English | MEDLINE | ID: mdl-38995767

ABSTRACT

BACKGROUND: The prosthetic foot is an essential component of the prosthetic limb used by people who suffer from amputation. The prosthetic foot or limb is expensive in developing countries and cannot be used by most people with special needs. OBJECTIVE: In this study, an uncomplicated prosthetic foot is designed that can be manufactured at low costs using 3D printer technology and can be provided to a wide range of amputees. The foot was designed using CAD software and analyzed using ANSES. METHODS: Carbon fiber material was chosen to be suitable for the manufacturing process using 3D printer technology. The selected material was tested in tensile and fatigue tests to determine its mechanical properties. The numerical analysis was carried out assuming the use of an artificial foot by a patient weighing 85 kg. RESULTS: The results showed that the material proposed for manufacturing has good mechanical properties for this application. The results of the engineering analysis also showed that the model has successfully passed the design process and is reliable for use by amputees. CONCLUSION: The success model designed in this study in the numerical analysis process gives reliability to the use of this design to manufacture the prosthetic foot.


Subject(s)
Artificial Limbs , Computer Simulation , Foot , Printing, Three-Dimensional , Prosthesis Design , Humans , Tensile Strength , Computer-Aided Design , Amputees/rehabilitation , Carbon Fiber/chemistry , Materials Testing , Finite Element Analysis , Stress, Mechanical
14.
Ann Med ; 56(1): 2380798, 2024 Dec.
Article in English | MEDLINE | ID: mdl-39061117

ABSTRACT

PURPOSE: This study aimed to evaluate the pressure distribution and comfort of transtibial prosthesis wearers using an affordable ethyl-vinyl acetate (EVA) roll-on (AERO) liner. METHOD: Fifteen unilateral transtibial prosthesis users wore patella tendon bearing (PTB) sockets with a polyethylene foam (PE-lite) liner were enrolled this study. AERO liners were provided to all participants. Six force sensors were applied to the residual limb to evaluate pressure distribution during treadmill walking, and the socket comfort score (SCS) was used to evaluate comfortability. Fourier transform infrared (FT-IR) spectroscopy was performed on the EVA and PE-lite liners. RESULTS: Eleven participants used prefabricated AERO liners and four participants used custom-made AERO liners. The pressure distribution was analysed by the coefficient of variation (CV): PE-lite was 75.7 ± 6.0 and AERO liner 83.3 ± 4.1. Residual limb pressure was significantly decreased when using the AERO liner (p = .0007), with a large effect size (r = 0.87). Mean SCS was 7.5 ± 1.3 and 8.9 ± 1.1 for PE-lite and AERO liner respectively. CONCLUSION: Better pressure distribution and comfort were observed when the participants used the AERO liner. AERO had a greater proportion of calcium carbonate (CaCO3). These findings suggest that the AERO liner is a better off-the-shelf option for persons using traditional prosthetic sockets and liners.


Subject(s)
Artificial Limbs , Pressure , Prosthesis Design , Humans , Male , Middle Aged , Female , Aged , Vinyl Compounds/chemistry , Adult , Polyethylene , Spectroscopy, Fourier Transform Infrared/methods , Patient Comfort , Walking/physiology , Tibia/surgery
15.
J Neuroeng Rehabil ; 21(1): 128, 2024 Jul 31.
Article in English | MEDLINE | ID: mdl-39085954

ABSTRACT

BACKGROUND: Systems that capture motion under laboratory conditions limit validity in real-world environments. Mobile motion capture solutions such as Inertial Measurement Units (IMUs) can progress our understanding of "real" human movement. IMU data must be validated in each application to interpret with clinical applicability; this is particularly true for diverse populations. Our IMU analysis method builds on the OpenSim IMU Inverse Kinematics toolkit integrating the Versatile Quaternion-based Filter and incorporates realistic constraints to the underlying biomechanical model. We validate our processing method against the reference standard optical motion capture in a case report with participants with transfemoral amputation fitted with a Percutaneous Osseointegrated Implant (POI) and without amputation walking over level ground. We hypothesis that by using this novel pipeline, we can validate IMU motion capture data, to a clinically acceptable degree. RESULTS: Average RMSE (across all joints) between the two systems from the participant with a unilateral transfemoral amputation (TFA) on the amputated and the intact sides were 2.35° (IQR = 1.45°) and 3.59° (IQR = 2.00°) respectively. Equivalent results in the non-amputated participant were 2.26° (IQR = 1.08°). Joint level average RMSE between the two systems from the TFA ranged from 1.66° to 3.82° and from 1.21° to 5.46° in the non-amputated participant. In plane average RMSE between the two systems from the TFA ranged from 2.17° (coronal) to 3.91° (sagittal) and from 1.96° (transverse) to 2.32° (sagittal) in the non-amputated participant. Coefficients of Multiple Correlation (CMC) results between the two systems in the TFA ranged from 0.74 to > 0.99 and from 0.72 to > 0.99 in the non-amputated participant and resulted in 'excellent' similarity in each data set average, in every plane and at all joint levels. Normalized RMSE between the two systems from the TFA ranged from 3.40% (knee level) to 54.54% (pelvis level) and from 2.18% to 36.01% in the non-amputated participant. CONCLUSIONS: We offer a modular processing pipeline that enables the addition of extra layers, facilitates changes to the underlying biomechanical model, and can accept raw IMU data from any vendor. We successfully validate the pipeline using data, for the first time, from a TFA participant using a POI and have proved our hypothesis.


Subject(s)
Amputation, Surgical , Artificial Limbs , Humans , Biomechanical Phenomena , Amputation, Surgical/rehabilitation , Femur/surgery , Osseointegration/physiology , Male , Proof of Concept Study , Amputees/rehabilitation , Walking/physiology , Adult , Bone-Anchored Prosthesis
16.
Prosthet Orthot Int ; 48(3): 337-343, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38857166

ABSTRACT

BACKGROUND: Hip- and pelvic-level amputations are devastating injuries that drastically alter patient function and quality of life. This study examined the experience of military beneficiaries with a hip- or pelvic-level amputation to better characterize their challenges and specific needs and to optimize treatment in the future. METHODS: We conducted a retrospective review of the Military Health System and identified 118 patients with a history of one or more amputation(s) at the hip or pelvic level between October 2001 and September 2017. Surviving participants (n = 97) were mailed a letter which explained the details of the study and requested participation in a telephonic interview. A total of six individuals (one female, five males) participated in structured interviews. RESULTS: The study group included four participants with hip disarticulations and two participants with hemipelvectomies (one internal, one external). All six participants reported significant challenges with activities related to prosthetic use, mobility, residual limb health, pain, gastrointestinal and genitourinary function, psychiatric health, and sexual function. CONCLUSIONS: These interviews highlight the unique needs of individuals with hip- and pelvic-level amputations and may improve access to higher echelons of care that would enhance the function and quality of life for these participants.


Subject(s)
Artificial Limbs , Military Personnel , Quality of Life , Humans , Male , Female , Retrospective Studies , Adult , Middle Aged , Military Personnel/psychology , Amputation, Surgical/rehabilitation , Amputation, Surgical/psychology , Hemipelvectomy , Amputees/psychology , Amputees/rehabilitation , United States , Pelvis
17.
PLoS One ; 19(6): e0303397, 2024.
Article in English | MEDLINE | ID: mdl-38848334

ABSTRACT

A novel powered ankle-foot prosthesis is designed. The effect of wearing the novel prosthesis and an energy-storage-and-return (ESAR) foot on lower-limb biomechanics is investigated to preliminarily evaluate the design. With necessary auxiliary materials, a non-amputated subject (a rookie at using prostheses) is recruited to walk on level ground with an ESAR and the novel powered prostheses separately. The results of the stride characteristics, the ground reaction force (GRF) components, kinematics, and kinetics in the sagittal plane are compared. Wearing the powered prosthesis has less prolongation of the gait cycle on the unaffected side than wearing the ESAR foot. Wearing ESAR or proposed powered prostheses influences the GRF, kinematics, and kinetics on the affected and unaffected sides to some extent. Thereinto, the knee moment on the affected side is influenced most. Regarding normal walking as the reference, among the total of 15 indexes, the influences of wearing the proposed powered prosthesis on six indexes on the affected side (ankle's/knee's/hip's angles, hip's moment, and Z- and X-axis GRF components) and five indexes on the unaffected side (ankle's/knee's/hip's angles and ankle's/hip's moments) are slighter than those of wearing the ESAR foot. The influences of wearing the powered prosthesis on two indexes on the unaffected side (knee's moment and X-axis GRF component) are similar to those of wearing the ESAR foot. The greatest improvement of wearing the powered prosthesis is to provide further plantarflexion after reaching the origin of the ankle joint before toe-off, which means that the designed powered device can provide further propulsive power for the lifting of the human body's centre of gravity during walking on level ground. The results demonstrate that wearing the novel powered ankle-foot prosthesis benefits the rookie in recovering the normal gait more than wearing the ESAR foot.


Subject(s)
Artificial Limbs , Foot , Prosthesis Design , Humans , Biomechanical Phenomena , Foot/physiology , Gait/physiology , Walking/physiology , Male , Ankle/physiology , Ankle Joint/physiology , Adult , Lower Extremity/physiology
18.
J Biomech ; 170: 112177, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38838496

ABSTRACT

This study investigates the differences in peak plantar pressure between the amputated and intact limbs of transfemoral amputees when walking outdoors. Ten non-amputees (aged 24.4 ± 2.0 years, 176.9 ± 2.5 cm, 72.3 ± 7.9 kg) and six transfemoral amputees (48.5 ± 6.3 years, 173.8 ± 4.2 cm, 82.0 ± 11.9 kg) participated in the study. Over approximately 1.6 km, the participants encountered various obstacles, including stairs, uneven surfaces, hills, and level ground, both indoors and outdoors. Throughout the walking session, the peak plantar pressure in both feet was monitored using wearable insole sensors. For all terrains, the percentage asymmetry was determined. Significant changes in peak plantar pressure asymmetry were found between the intact and amputated limbs, particularly when walking on level ground indoors, uneven terrains, descending stairs, and on steep slopes outdoors (all p < 0.05). These findings highlight the greater peak plantar pressure asymmetry in transfemoral amputees when walking outside. In addition, this study revealed that not all terrains contribute uniformly to this asymmetry.


Subject(s)
Amputees , Foot , Pressure , Walking , Humans , Walking/physiology , Amputees/rehabilitation , Male , Adult , Middle Aged , Foot/physiology , Female , Biomechanical Phenomena , Femur/surgery , Femur/physiology , Artificial Limbs , Young Adult
19.
J Appl Physiol (1985) ; 137(1): 85-98, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38841756

ABSTRACT

Similar to nonamputees, female athletes with unilateral transtibial amputation (TTA) using running-specific leg prostheses (RSPs) may have worse running economy and higher rates of running-related injury than male athletes. Optimizing RSP configuration for female athletes could improve running economy and minimize biomechanical asymmetry, which has been associated with running-related injury. Nine females with a TTA ran at 2.5 m/s while we measured metabolic rates and ground reaction forces. Subjects used an RSP with a manufacturer-recommended stiffness category, one category less stiff and two categories less stiff than recommended. Use of an RSP two categories less stiff resulted in 3.0% lower net metabolic power (P = 0.04), 7.8% lower affected leg stiffness (P = 6.01 × 10-4), increased contact time asymmetry (P = 0.04), and decreased stance average vertical ground reaction force asymmetry (P = 0.04) compared with a recommended stiffness category RSP. Lower RSP stiffness (kN/m) values were associated with lower net metabolic power (P = 0.02), lower affected leg stiffness (P = 1.36 × 10-4), longer affected leg contact time (P = 1.46 × 10-4), and similar affected leg peak and stance-average vertical ground reaction force compared with higher RSP stiffness values. Subjects then used the RSP stiffness category that elicited the lowest net metabolic power with 100 g, 200 g, and 300 g added distally. We found no significant effects of added mass on net metabolic power, biomechanics, or asymmetry. These results suggest that female runners with a TTA could decrease metabolic power during running while minimizing biomechanical asymmetries, which have been associated with running-related injury, by using an RSP two categories less stiff than manufacturer recommended.NEW & NOTEWORTHY Females with unilateral transtibial amputation can improve running performance through reductions in net metabolic power by using a running-specific prosthesis (RSP) that is less stiff than manufacturer-recommended. Lower RSP stiffness values are associated with greater leg stiffness and contact time asymmetry, and lower stance-average vertical ground reaction force asymmetry. However, we found that adding mass to the RSP did not affect net metabolic power and stance-phase biomechanical asymmetries during running.


Subject(s)
Amputation, Surgical , Artificial Limbs , Leg , Running , Humans , Female , Running/physiology , Adult , Biomechanical Phenomena/physiology , Leg/physiology , Amputees , Young Adult , Prosthesis Design , Athletes , Middle Aged , Energy Metabolism/physiology
20.
J Biomech ; 171: 112201, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38936310

ABSTRACT

One of the most significant developments in prosthetic knee technology has been the introduction of the Microprocessor-Controlled Prosthetic Knee (MPK). However, there is a lack of consensus over how different types of MPKs affect performance in different ambulation modes. In this study, we investigated the biomechanical differences in ramp and stair maneuvers when an individual with transfemoral amputation wears three commercial MPKs: the Össur Power Knee, the Össur Rheo Knee and the Ottobock C-Leg 4. The primary outcome variable for this study was the lower limb biological joint work, inclusive of the intact leg and prosthetic side hip. We hypothesized that (1) the Power Knee would result in lower biological work during ascent activities than the C-Leg and Rheo, both passive MPKs, and (2) the C-Leg and Rheo would result in lower biological work during descent activities than the Power Knee. During ramp ascent, the C-Leg was associated with lower biological joint work (p < 0.05) than the Power Knee. However, this relationship did not hold during stair ascent, where the Power Knee showed advantages for stair ascent with net reductions in biological joint work of 14.1% and 23.3% compared to the Rheo and C-leg, respectively. There were no significant differences in biological joint work between the knees during ramp and stair descent, indicating that choice of MPK may not be as important for descent activities. Our results demonstrate that differences are present between different types of MPKs during ascent activities which could prove useful in the prescription of these devices.


Subject(s)
Knee Joint , Humans , Knee Joint/physiology , Male , Biomechanical Phenomena , Artificial Limbs , Walking/physiology , Adult , Knee Prosthesis , Prosthesis Design , Lower Extremity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL