Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.289
Filter
1.
Saudi Med J ; 45(10): 1094-1098, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39379114

ABSTRACT

OBJECTIVES: To report and describe the characteristics and outcomes of patients with advanced atrioventricular block (AVB) in Saudi Arabia. METHODS: We included consecutive patients who underwent pacemaker implantation at King Khaled University Hospital, Riyadh, Saudi Arabia, for advanced AVB, which was defined as second degree type 2 AVB, third degree AVB, and symptomatic atrial fibrillation with slow ventricular response. The variable "young patient" was defined as age of 60 or less, based on guidelines recommending cardiac sarcoidosis (CS) evaluation at this age or younger. RESULTS: Among 100 patients (median age: 71 males, 51%), 29 (29%) were young patients. Most patients had at least one comorbidity including hypertension, diabetes, or dyslipidemia (81%). Young patients constituted 26.6% (n=21/79) of idiopathic AVB cases and only 23.8% (n=8/21) underwent CS evaluation (8/21). CONCLUSION: A significant proportion of AVB occurs in young patients. Yet, CS is often not ruled out. Future studies should define the yield of CS evaluation in the Saudi population when international consensus documents are followed.


Subject(s)
Atrioventricular Block , Humans , Atrioventricular Block/epidemiology , Atrioventricular Block/therapy , Male , Saudi Arabia/epidemiology , Female , Retrospective Studies , Middle Aged , Adult , Aged , Cohort Studies , Sarcoidosis/epidemiology , Sarcoidosis/complications , Pacemaker, Artificial , Treatment Outcome , Age Factors , Cardiomyopathies/epidemiology , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Comorbidity
2.
BMC Cardiovasc Disord ; 24(1): 512, 2024 Sep 27.
Article in English | MEDLINE | ID: mdl-39327551

ABSTRACT

The halo-shape technique (HST) is an emerging approach for implanting a leadless pacemaker in scoliosis patients in recent years. Severe scoliosis and humpback made it challenging to push the tip of the delivery catheter towards the ventricular septum using the conventional gooseneck-shape technique. The feasibility and safety of the use of HST in an octogenarian with severe dextroscoliosis and humpback have not been well-assessed. Here, we report a case of high-degree atrioventricular block octogenarian with severe dextroscoliosis and humpback who successfully received a leadless pacemaker implantation using HST. Procedure-related complications were not observed, and the electrical parameters were stable at 6-month follow-up.


Subject(s)
Atrioventricular Block , Cardiac Pacing, Artificial , Pacemaker, Artificial , Humans , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Atrioventricular Block/diagnosis , Treatment Outcome , Aged, 80 and over , Scoliosis/therapy , Scoliosis/diagnosis , Scoliosis/diagnostic imaging , Female , Severity of Illness Index , Male
3.
Europace ; 26(9)2024 Aug 30.
Article in English | MEDLINE | ID: mdl-39271128

ABSTRACT

AIMS: In complete atrioventricular block (AVB) with underlying sinus rhythm, it is recommended to implant a dual-chamber pacemaker rather than a single-chamber pacemaker. However, no large-scale study has been able to demonstrate the superiority of this choice on hard clinical criteria such as morbimortality. METHODS AND RESULTS: This retrospective observational study included all patients who received a primary pacemaker implantation in the indication of complete AVB with underlying sinus rhythm in France, based on the national administrative database between January 2013 and December 2022. After propensity score matching, we obtained two groups containing 19 219 patients each. The incidence of all-cause mortality was 9.22%/year for the dual-chamber pacemaker group, compared with 11.48%/year for the single-chamber pacemaker group (hazard ratio (HR) 0.807, P < 0.0001]. Similarly, there was a lower incidence of cardiovascular mortality (HR 0.766, P < 0.0001), heart failure (HR 0.908, P < 0.0001), atrial fibrillation (HR 0.778, P < 0.0001), and ischaemic stroke (HR 0.873, P = 0.008) in the dual-chamber pacemaker group than in the single-chamber pacemaker group. Regarding re-interventions and complications, there were fewer upgrades (addition of atrial lead or left ventricular lead) in the dual-chamber group (HR 0.210, P < 0.0001), but more haematomas (HR 1.179, P = 0.006) and lead repositioning (HR 1.123, P = 0.04). CONCLUSION: In the indication of complete AVB with underlying sinus rhythm, our results are consistent with current recommendations to prefer implantation of a dual-chamber pacemaker rather than a single-chamber pacemaker for these patients. Implantation of a dual-chamber pacemaker is associated with a lower risk of mortality, heart failure, atrial fibrillation, and stroke during follow-up.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Atrioventricular Block/therapy , Atrioventricular Block/mortality , Atrioventricular Block/physiopathology , Female , Male , Aged , Retrospective Studies , France/epidemiology , Aged, 80 and over , Cardiac Pacing, Artificial/methods , Cardiac Pacing, Artificial/mortality , Middle Aged , Atrial Fibrillation/mortality , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Incidence , Heart Rate
6.
Europace ; 26(8)2024 Aug 03.
Article in English | MEDLINE | ID: mdl-39120658

ABSTRACT

AIMS: Physiological activation of the heart using algorithms to minimize right ventricular pacing (RVPm) may be an effective strategy to reduce adverse events in patients requiring anti-bradycardia therapies. This systematic review and meta-analysis aimed to evaluate current evidence on clinical outcomes for patients treated with RVPm algorithms compared to dual-chamber pacing (DDD). METHODS AND RESULTS: We conducted a systematic search of the PubMed database. The predefined endpoints were the occurrence of persistent/permanent atrial fibrillation (PerAF), cardiovascular (CV) hospitalization, all-cause death, and adverse symptoms. We also aimed to explore the differential effects of algorithms in studies enrolling a high percentage of atrioventricular block (AVB) patients. Eight studies (7229 patients) were included in the analysis. Compared to DDD pacing, patients using RVPm algorithms showed a lower risk of PerAF [odds ratio (OR) 0.74, 95% confidence interval (CI) 0.57-0.97] and CV hospitalization (OR 0.77, 95% CI 0.61-0.97). No significant difference was found for all-cause death (OR 1.01, 95% CI 0.78-1.30) or adverse symptoms (OR 1.03, 95% CI 0.81-1.29). No significant interaction was found between the use of the RVPm strategy and studies enrolling a high percentage of AVB patients. The pooled mean RVP percentage for RVPm algorithms was 7.96% (95% CI 3.13-20.25), as compared with 45.11% (95% CI 26.64-76.38) of DDD pacing. CONCLUSION: Algorithms for RVPm may be effective in reducing the risk of PerAF and CV hospitalization in patients requiring anti-bradycardia therapies, without an increased risk of adverse symptoms. These results are also consistent for studies enrolling a high percentage of AVB patients.


Subject(s)
Algorithms , Atrial Fibrillation , Cardiac Pacing, Artificial , Aged , Female , Humans , Male , Atrial Fibrillation/therapy , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/mortality , Atrioventricular Block/diagnosis , Atrioventricular Block/mortality , Atrioventricular Block/physiopathology , Atrioventricular Block/therapy , Bradycardia/therapy , Bradycardia/prevention & control , Bradycardia/mortality , Bradycardia/diagnosis , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Heart Rate , Heart Ventricles/physiopathology , Hospitalization/statistics & numerical data , Pacemaker, Artificial/adverse effects , Risk Factors , Treatment Outcome , Ventricular Function, Right
7.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38954426

ABSTRACT

AIMS: Prior case series showed promising results for cardioneuroablation in patients with vagally induced atrioventricular blocks (VAVBs). We aimed to examine the acute procedural characteristics and intermediate-term outcomes of electroanatomical-guided cardioneuroablation (EACNA) in patients with VAVB. METHODS AND RESULTS: This international multicentre retrospective registry included data collected from 20 centres. Patients presenting with symptomatic paroxysmal or persistent VAVB were included in the study. All patients underwent EACNA. Procedural success was defined by the acute reversal of atrioventricular blocks (AVBs) and complete abolition of atropine response. The primary outcome was occurrence of syncope and daytime second- or advanced-degree AVB on serial prolonged electrocardiogram monitoring during follow-up. A total of 130 patients underwent EACNA. Acute procedural success was achieved in 96.2% of the cases. During a median follow-up of 300 days (150, 496), the primary outcome occurred in 17/125 (14%) cases with acute procedural success (recurrence of AVB in 9 and new syncope in 8 cases). Operator experience and use of extracardiac vagal stimulation were similar for patients with and without primary outcomes. A history of atrial fibrillation, hypertension, and coronary artery disease was associated with a higher primary outcome occurrence. Only four patients with primary outcome required pacemaker placement during follow-up. CONCLUSION: This is the largest multicentre study demonstrating the feasibility of EACNA with encouraging intermediate-term outcomes in selected patients with VAVB. Studies investigating the effect on burden of daytime symptoms caused by the AVB are required to confirm these findings.


Subject(s)
Atrioventricular Block , Registries , Humans , Male , Female , Retrospective Studies , Aged , Middle Aged , Treatment Outcome , Atrioventricular Block/physiopathology , Atrioventricular Block/therapy , Atrioventricular Block/surgery , Catheter Ablation/methods , Time Factors , Vagus Nerve Stimulation/methods , Electrophysiologic Techniques, Cardiac , Syncope/etiology , Recurrence , Atrioventricular Node/surgery , Atrioventricular Node/physiopathology
8.
J Cardiothorac Surg ; 19(1): 462, 2024 Jul 20.
Article in English | MEDLINE | ID: mdl-39033097

ABSTRACT

BACKGROUND: High-grade atrioventricular block is the primary reason for epicardial permanent pacemaker implantation during the perioperative period in patients with congenital heart disease. Due to the smaller diameter of venous vessels in children, epicardial permanent pacemaker implantation is usually a preferred choice, we report one pediatric patient who received epicardial permanent pacemaker implantation using a new approach. CASE PRESENTATION: We present the case of a 2-year-old girl who underwent the modified Konno procedure and Pulmonary valvuloplasty surgery and presented after surgery with a High-grade atrioventricular block. At over 20 days after the patient underwent a redo-sternotomy which epicardial permanent pacemaker implantation. Medtronic Model 4965 Capsure Epi ® steroid-eluting unipolar epicardial pacing lead was immobilized on the surface of the right ear. The Medtronic 3830 pacing lead was screwed obliquely and clockwise under direct view from the surface of the right ventricle to the endocardium near the interventricular septum. The patient's recovery was uneventful. CONCLUSION: In this case report, we demonstrate the feasibility and potential benefits of using the Medtronic 3830 lead for epicardial pacing in a pediatric patient with severe cardiac complications following surgery for congenital heart disease. This approach offers a viable alternative to traditional epicardial pacing methods, particularly in complex cases where conventional leads fail to provide stable pacing thresholds.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Female , Child, Preschool , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Feasibility Studies , Pericardium/surgery , Heart Defects, Congenital/surgery , Cardiac Pacing, Artificial/methods
9.
Arch Cardiovasc Dis ; 117(8-9): 505-513, 2024.
Article in English | MEDLINE | ID: mdl-38981841

ABSTRACT

BACKGROUND: Pacemaker implantation combined with atrioventricular node ablation (AVNA) is a well-established strategy for uncontrolled atrial arrhythmias. Limited data are available regarding His bundle pacing (HBP) and left bundle branch area pacing (LBBAP) in this setting. AIM: To compare the outcomes of HBP and LBBAP in patients undergoing pacemaker implantation combined with AVN in routine clinical practice. METHODS: We prospectively included all patients who underwent AVNA after successful conduction system pacing (CSP) in two hospitals between September 2017 and May 2023. The primary outcome was the 1-year composite of first episode of heart failure hospitalization, symptomatic atrioventricular node reconduction requiring a second AVNA procedure, lead revision or death from any cause. RESULTS: A total of 164 patients underwent AVNA following successful CSP (68 HBP and 96 LBBAP). Mean pacemaker implantation and AVNA procedure times were shorter in the LBBAP group than the HBP group (46±18 vs 59±23min; P<0.001 and 31±12 vs 43±22min, respectively; P<0.001). Complete atrioventricular block was more frequently obtained in the LBBAP group (88/96 patients [92%] vs 54/68 patients [79%]; P=0.04). One-year freedom from the composite outcome was more frequent in the LBBAP group (89.7% vs 72.9%; hazard ratio 0.32, 95% confidence interval 0.14-0.72; P=0.01). The strategy was similarly effective in both groups with a significant improvement in NYHA class and left ventricular ejection fraction. A secondary pacing threshold elevation >1V occurred only in the HBP group (11%). CONCLUSION: In this prospective, comparative study, LBBAP provided better 1-year outcomes than HBP.


Subject(s)
Atrioventricular Node , Bundle of His , Cardiac Pacing, Artificial , Humans , Prospective Studies , Male , Female , Bundle of His/physiopathology , Aged , Atrioventricular Node/physiopathology , Atrioventricular Node/surgery , Treatment Outcome , Time Factors , Middle Aged , Catheter Ablation/adverse effects , Heart Rate , Risk Factors , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Atrioventricular Block/diagnosis , Aged, 80 and over , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/diagnosis , Heart Failure/mortality , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/surgery , Action Potentials
10.
J Cardiothorac Surg ; 19(1): 443, 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39003494

ABSTRACT

BACKGROUND: Lead dislodgements, tricuspid valve failure, and wound infections are prominent issues addressed by leadless pacemakers (LPM). These devises have emerged as viable alternatives to conventional transvenous pacemakers. LPMs offer minimized complications and effective pacing, particularly beneficial for elderly patients with a low body mass index (BMI) who are at heightened infection of risk. The Micra AV leadless pacemaker was released in the US in 2020, featuring a VDD pacing mode akin to conventional pacemakers. It senses atrial activity to pace ventricular beats while maintaining the natural atrioventricular activation sequence. Micra AV achieves atrioventricular synchronization through mechanical sensing principles. Ongoing research aims to assess its efficacy, implantation feasibility, and clinical safety. CASE PRESENTATION: An 83-year-old man with a history of syncope was the focus of this case study. An implantable cardiac monitor (ICM) recorded occasional high-degree atrioventricular block in the patient. Subsequently, the Micra AV was implanted via the left femoral vein, and its settings were adjusted in accordance with data obtained from the ICM. No significant issues regarding pacing threshold or impedance were found during the follow-up examinations post-surgery. Importantly, the patient experienced a noticeable reduction in symptoms compared to before the implantation. DISCUSSION: This case underscores the significance of ICM monitoring in elucidating cardiac events leading to syncope and guiding appropriate treatment. It also highlights the successful outcomes and reliable implantation of the Micra AV for managing high-degree atrioventricular block. This study contributes to the growing body of evidence supporting the adoption of leadless pacemakers as a viable option for patients requiring cardiac pacing, particularly those vulnerable to complications associated with traditional pacemakers. It provides real-world evidence of Micra AV's efficacy and safety, further validating its role in clinical practice.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Syncope , Humans , Male , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Syncope/therapy , Syncope/etiology , Aged, 80 and over , Equipment Design
11.
BMC Cardiovasc Disord ; 24(1): 370, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39020323

ABSTRACT

BACKGROUND: Anomalous aortic origin of a coronary artery from the inappropriate sinus of Valsalva (AAOCA) is a rare congenital heart lesion. It is uncommon for patients with AAOCA to present with severe symptoms at a very young age. CASE PRESENTATION: We describe a very rare but critical presentation in a young infant with AAOCA that requires surgical repair and pacemaker placement. A three-month-old infant was referred because of syncope. Cardiac arrest occurred shortly after admission. The electrocardiogram indicated a complete atrioventricular block and a transvenous temporary pacemaker was implanted. A further coronary computed tomographic angiography (CTA) showed the anomalous origin of the right coronary artery from the left sinus of Valsalva. Coronary artery unroofing was performed due to an interarterial course with the intramural component, and a permanent epicardial pacemaker was implanted. The postoperative recovery was uneventful, and this patient was thriving and asymptomatic at the nine-month follow-up. However, the electrocardiogram still indicated a complete pacing rhythm. CONCLUSIONS: By timely diagnosis and treatment, this patient is successfully rescued. Although rare, AAOCA may be fatal even in infants.


Subject(s)
Cardiac Pacing, Artificial , Coronary Vessel Anomalies , Pacemaker, Artificial , Humans , Infant , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/therapy , Coronary Vessel Anomalies/surgery , Treatment Outcome , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/abnormalities , Sinus of Valsalva/surgery , Sinus of Valsalva/physiopathology , Heart Arrest/etiology , Heart Arrest/therapy , Heart Arrest/diagnosis , Coronary Angiography , Male , Electrocardiography , Computed Tomography Angiography
13.
Future Cardiol ; 20(5-6): 281-286, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38975696

ABSTRACT

One of the most common complications of tricuspid valve replacement is atrioventricular block (AVB), often requiring permanent pacing. The endocardial pacemaker lead, placed in the right ventricle, may sometimes interfere with the implanted prosthesis, causing its early dysfunction and the need for alternative sites of pacing. To the best of our knowledge, we present the first case of a successful combined percutaneous procedure consisting of the implantation of two leads in the coronary sinus for univentricular bifocal pacing and a transcatheter tricuspid valve-in-valve implantation in a young patient with severe dysfunction of the tricuspid bioprosthesis, requiring permanent pacing for a postsurgical complete atrioventricular block.


Tricuspid valve replacement with surgery can often lead to cardiac rhythm disorders requiring a permanent pacemaker. This device may occasionally damage the tricuspid prosthesis. We present the first case of a combined procedure of tricuspid valve replacement and device implantation distant from the prosthesis without the need for a surgical approach in a young patient with severe tricuspid prosthesis malfunctioning and permanent pacing.


Subject(s)
Cardiac Catheterization , Cardiac Pacing, Artificial , Coronary Sinus , Heart Valve Prosthesis Implantation , Tricuspid Valve , Humans , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Coronary Sinus/surgery , Cardiac Catheterization/methods , Cardiac Pacing, Artificial/methods , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Bioprosthesis , Heart Valve Prosthesis , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnosis , Pacemaker, Artificial , Female , Male , Adult
14.
G Ital Cardiol (Rome) ; 25(8): 567-575, 2024 Aug.
Article in Italian | MEDLINE | ID: mdl-39072595

ABSTRACT

Transcatheter aortic valve implantation may be complicated by the development of conduction disturbances, including left bundle branch block and high-grade atrioventricular blocks, especially in patients with predisposing risk factors, such as pre-existing right bundle branch block. Permanent pacemaker implantation is a procedure with potential short- and long-term complications, and it should be reserved to patients with appropriate indications. Electrophysiological testing and/or prolonged ambulatory ECG monitoring are valuable tools for stratifying the risk of pacemaker implantation. However, the management of new-onset conduction disorders is not always straightforward, and there are different approaches depending on the center's attitude. Therefore, the purpose of this review is to define clinical management based on current evidence, while awaiting data from randomized trials.


Subject(s)
Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Incidence , Risk Factors , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Pacemaker, Artificial/adverse effects , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , Bundle-Branch Block/epidemiology , Aortic Valve Stenosis/surgery , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Atrioventricular Block/epidemiology
15.
J Med Internet Res ; 26: e41843, 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39028996

ABSTRACT

BACKGROUND: There are limited data available on the development of arrhythmias in patients at risk of high-degree atrioventricular block (HAVB) or complete heart block (CHB) following transcatheter aortic valve replacement (TAVR). OBJECTIVE: This study aimed to explore the incidence and evolution of arrhythmias by monitoring patients at risk of HAVB or CHB after TAVR using smartwatches. METHODS: We analyzed 188 consecutive patients in the prospective SMART TAVR (smartwatch-facilitated early discharge in patients undergoing TAVR) trial. Patients were divided into 2 groups according to the risk of HAVB or CHB. Patients were required to trigger a single-lead electrocardiogram (ECG) recording and send it to the Heart Health App via their smartphone. Physicians in the central ECG core lab would then analyze the ECG. The incidence and timing of arrhythmias and pacemaker implantation within a 30-day follow-up were compared. All arrhythmic events were adjudicated in a central ECG core lab. RESULTS: The mean age of the patients was 73.1 (SD 7.3) years, of whom 105 (55.9%) were men. The mean discharge day after TAVR was 2.0 (SD 1.8) days. There were no statistically significant changes in the evolution of atrial fibrillation or atrial flutter, Mobitz I, Mobitz II, and third-degree atrial ventricular block over time in the first month after TAVR. The incidence of the left bundle branch block (LBBB) increased in the first week and decreased in the subsequent 3 weeks significantly (P<.001). Patients at higher risk of HAVB or CHB received more pacemaker implantation after discharge (n=8, 9.6% vs n=2, 1.9%; P=.04). The incidence of LBBB was higher in the group with higher HAVB or CHB risk (n=47, 56.6% vs n=34, 32.4%; P=.001). The independent predictors for pacemaker implantation were age, baseline atrial fibrillation, baseline right bundle branch block, Mobitz II, and third-degree atrioventricular block detected by the smartwatch. CONCLUSIONS: Except for LBBB, no change in arrhythmias was observed over time in the first month after TAVR. A higher incidence of pacemaker implantation after discharge was observed in patients at risk of HAVB or CHB. However, Mobitz II and third-degree atrioventricular block detected by the smartwatch during follow-ups were more valuable indicators to predict pacemaker implantation after discharge from the index TAVR. TRIAL REGISTRATION: ClinicalTrials.gov NCT04454177; https://clinicaltrials.gov/study/NCT04454177.


Subject(s)
Arrhythmias, Cardiac , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Prospective Studies , Aged, 80 and over , Electrocardiography , Atrioventricular Block/etiology , Atrioventricular Block/therapy
16.
Curr Vasc Pharmacol ; 22(4): 251-265, 2024.
Article in English | MEDLINE | ID: mdl-38920075

ABSTRACT

INTRODUCTION: Permanent pacemakers are an established treatment for sick sinus syndrome and high-grade atrioventricular block. Permanent cardiac pacemaker implantations may damage the myocardium. OBJECTIVE: This study evaluated markers of myocardial injury, oxidative stress and inflammation in elderly patients with permanent pacemaker implantations. METHODS: Various markers were measured at 1, 2, 3 and 4 months after permanent pacemaker implantations in elderly patients. RESULTS: The levels of high-sensitivity troponin T (hsTnT), lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1), malondialdehyde-modified low-density lipoprotein (MDA-LDL), oxidized low-density lipoprotein (OX-LDL), tumour necrosis factor-α (TNF-α), toll-like receptor 4 (TLR4) and nuclear factor-kappa B (NF-κB) were increased in 2-month group compared with control and 1- month groups (P<0.001), and were further increased at 4-month group compared with 2- and 3- month groups after pacemaker implantations (P<0.001). Patients with dual-chamber pacemakers had higher levels of hsTnT, LOX-1, MDA-LDL, OX-LDL, TNF-α, TLR4 and NF-κB than patients with single chamber pacemakers (P<0.001). Patients who underwent the pacemakers with the active fixation leads had raised levels of hsTnT, LOX-1, MDA-LDL, OX-LDL, TNF-α, TLR4 and NF-κB compared patients with pacemakers using the passive fixation leads (P<0.001). Myocardial blood flows in 3-month and 4-month groups were lower than 1-month and 2-month groups (P<0.001). CONCLUSION: Levels of hsTnT, LOX-1, MDA-LDL, OX-LDL, TNF-α, TLR4 and NF-κB were elevated in elderly patients with permanent pacemaker implantations and the activations of oxidative stress and pro-inflammatory signalling pathways may be associated with myocardial damages and ischemia after pacemaker implantations in elderly patients.


Subject(s)
Biomarkers , Lipoproteins, LDL , NF-kappa B , Oxidative Stress , Pacemaker, Artificial , Scavenger Receptors, Class E , Signal Transduction , Toll-Like Receptor 4 , Tumor Necrosis Factor-alpha , Humans , Toll-Like Receptor 4/blood , Toll-Like Receptor 4/metabolism , Male , NF-kappa B/metabolism , NF-kappa B/blood , Aged , Female , Scavenger Receptors, Class E/blood , Tumor Necrosis Factor-alpha/blood , Lipoproteins, LDL/blood , Pacemaker, Artificial/adverse effects , Biomarkers/blood , Aged, 80 and over , Time Factors , Age Factors , Cardiac Pacing, Artificial/adverse effects , Malondialdehyde/blood , Inflammation Mediators/blood , Cardiotoxicity , Sick Sinus Syndrome/therapy , Sick Sinus Syndrome/blood , Sick Sinus Syndrome/diagnosis , Sick Sinus Syndrome/physiopathology , Myocardium/metabolism , Myocardium/pathology , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Atrioventricular Block/blood , Atrioventricular Block/diagnosis
17.
BMJ Case Rep ; 17(6)2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38926126

ABSTRACT

Implantation of cardiac devices is usually considered to be a safe procedure. Rare complications, such as pneumothorax, may occur after the procedure. The association with pneumopericardium or pneumomediastinum is even more uncommon. We present the case of a patient in his 70s, on haemodialysis, admitted for complete atrioventricular block. He underwent implantation of a dual-chamber pacemaker. He presented with chest pain the day after implantation. Chest CT scan revealed a pneumothorax associated with a pneumopericardium and pneumomediastinum 'pan pneumo', due to an atrial perforation. We opted for a conservative management strategy. Repeat CT scan of the chest 8 days after the procedure showed a complete resorption of the 'pan pneumo'. The objective of this case report is to describe this rare complication and provide further insight into its management, particularly in the absence of specific guidelines.


Subject(s)
Mediastinal Emphysema , Pacemaker, Artificial , Pneumopericardium , Pneumothorax , Humans , Pacemaker, Artificial/adverse effects , Male , Aged , Pneumothorax/etiology , Pneumothorax/diagnostic imaging , Pneumopericardium/etiology , Pneumopericardium/diagnostic imaging , Mediastinal Emphysema/etiology , Mediastinal Emphysema/diagnostic imaging , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Tomography, X-Ray Computed , Heart Atria/diagnostic imaging , Heart Atria/injuries , Chest Pain/etiology
18.
Ann Med ; 56(1): 2365405, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38902995

ABSTRACT

BACKGROUND: Atrioventricular block (AVB) is rare in hyperthyroidism (HTH). Little is known about the true prevalence, clinical course, optimal management, and outcomes of different types of AVBs in patients with HTH. To address these uncertainties, we aimed to conduct a systematic review by combining the available literature to provide more meaningful data regarding AVBs in HTH. METHODS: We systematically searched PubMed, Scopus, Embase, and Google Scholar for articles reporting patients who developed AVB in the context of HTH. Data were analysed in STATA 16. The main outcomes included types of AVB, frequency of pacemaker insertion, and resolution of AVB. The systematic review is registered with the International Prospective Register of Systematic Reviews (PROSPERO) with the identification number CRD42022335598. RESULTS: A total of 56 studies (39 case reports, 12 case series, 3 conference abstracts, 1 retrospective study, and 1 prospective observational study) with 87 patients were included in the analysis, with a mean age of 39.1 ± 17.6 years. Females constituted 65.7% (n = 48) of the cohort. Complete heart block (CHB) was the most commonly reported AVB (N = 45, 51.7%), followed by first-degree AVB (16.1%) and second-degree AVB (14.9%). Overall, 21 patients underwent pacing. A permanent pacemaker was inserted in one patient with second-degree AVB and six patients with CHB. Mortality was reported in one patient with CHB. The clinical course and management of HTH and AVBs did not differ in patients with CHB or lower-degree blocks. Apart from lower rates of goitre and more use of carbimazole in those who underwent pacing, no differences were found when compared to the patients managed without pacing. CONCLUSION: Current data suggest that CHB is the most common type of AVB in patients with HTH. Most patients can be managed with anti-thyroid management alone. Additionally, whether pacemaker insertion alters the clinical outcomes needs further exploration.


Subject(s)
Atrioventricular Block , Hyperthyroidism , Pacemaker, Artificial , Humans , Hyperthyroidism/complications , Hyperthyroidism/therapy , Atrioventricular Block/therapy , Atrioventricular Block/epidemiology , Atrioventricular Block/etiology , Female , Male , Adult , Middle Aged
19.
Heart Rhythm ; 21(10): 1929-1938, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38697271

ABSTRACT

BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.


Subject(s)
Cardiac Pacing, Artificial , Equipment Design , Pacemaker, Artificial , Humans , Male , Female , Aged , Cardiac Pacing, Artificial/methods , Follow-Up Studies , Treatment Outcome , Heart Ventricles/physiopathology , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Time Factors , Sick Sinus Syndrome/therapy , Sick Sinus Syndrome/physiopathology
20.
Herzschrittmacherther Elektrophysiol ; 35(2): 144-147, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38775842

ABSTRACT

A 2:1 atrioventricular (AV) block can occur anywhere within the conduction system, and noninvasive measurements may not always predict the exact site of the block. Although localization of the block is critical for deciding any treatment, patients should also be carefully questioned about symptoms both at rest and during exertion. A case of 2:1 AV block that was symptomatic only during exertion, appeared infranodal by noninvasive diagnostic methods, but was found to be intranodal on electrophysiological study is reported.


Subject(s)
Atrioventricular Block , Electrocardiography , Humans , Middle Aged , Atrioventricular Block/diagnosis , Atrioventricular Block/physiopathology , Atrioventricular Block/therapy , Atrioventricular Block/complications , Diagnosis, Differential
SELECTION OF CITATIONS
SEARCH DETAIL