Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.118
1.
Clin Interv Aging ; 19: 695-703, 2024.
Article En | MEDLINE | ID: mdl-38711477

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Postoperative Complications , Propensity Score , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aged , Bicuspid Aortic Valve Disease/surgery , Aged, 80 and over , Postoperative Complications/epidemiology , Retrospective Studies , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/abnormalities , Middle Aged , Risk Factors , Heart Valve Diseases/surgery
2.
BMC Pediatr ; 24(1): 317, 2024 May 08.
Article En | MEDLINE | ID: mdl-38720245

BACKGROUND: Patients with Turner syndrome (TS) face an increased risk of developing aortic dilatation (AD), but diagnosing AD in children presents greater complexity compared to adults. This study aimed to investigate the application of various assessment indicators of AD in Chinese children and adolescents with TS. METHODS: This study included TS patients admitted to Shenzhen Children's Hospital from 2017 to 2022. Cardiovascular lesions were diagnosed by experienced radiologists. Patients without structural heart disease were divided into different body surface area groups, then the Chinese TS population Z-score (CHTSZ-score) of the ascending aorta was calculated and compared with other indicators such as aortic size index (ASI), ratio of the ascending to descending aortic diameter (A/D ratio), and TSZ-score (Quezada's method). RESULTS: A total of 115 TS patients were included, with an average age of 10.0 ± 3.7 years. The incidences of the three most serious cardiovascular complications were 9.6% (AD), 10.4% (coarctation of the aorta, CoA), and 7.0% (bicuspid aortic valve, BAV), respectively. The proportion of developing AD in TS patients aged ≥ 10 years was higher than that in those < 10 years old (16.6% vs. 1.8%, P = 0.009), and the proportion of patients with CoA or BAV who additionally exhibited AD was higher than those without these conditions (31.6% vs. 5.2%, P < 0.001). The ASI, A/D ratio, TSZ-score, and CHTSZ-score of the 11 patients with AD were 2.27 ± 0.40 cm/m2, 1.90 ± 0.37, 1.28 ± 1.08, and 3.07 ± 2.20, respectively. Among the AD patients, only 3 cases had a TSZ-score ≥ 2, and 2 cases had a TSZ-score ≥ 1. However, based on the assessment using the CHTSZ-score, 6 patients scored ≥ 2, and 5 patients scored ≥ 1. In contrast, the TSZ-score generally underestimated the aortic Z-scores in Chinese children with TS compared to the CHTSZ-score. CONCLUSIONS: The applicability of ASI and A/D ratio to children with TS is questionable, and racial differences can affect the assessment of TSZ-score in the Chinese population. Therefore, establishing the CHTSZ-score specifically tailored for Chinese children and adolescents is of paramount importance.


Turner Syndrome , Humans , Turner Syndrome/complications , Child , Adolescent , Female , China/epidemiology , Dilatation, Pathologic/etiology , Male , Retrospective Studies , Aorta/pathology , Aorta/diagnostic imaging , Aortic Coarctation , Bicuspid Aortic Valve Disease/complications , Child, Preschool , Incidence , East Asian People
3.
PLoS One ; 19(4): e0301350, 2024.
Article En | MEDLINE | ID: mdl-38626136

Bicuspid aortic valve (BAV) is the most common cardiac congenital abnormality with a high rate of concomitant aortic valve and ascending aorta (AAo) pathologic changes throughout the patient's lifetime. The etiology of BAV-related aortopathy was historically believed to be genetic. However, recent studies theorize that adverse hemodynamics secondary to BAVs also contribute to aortopathy, but their precise role, specifically, that of wall shear stress (WSS) magnitude and directionality remains controversial. Moreover, the primary therapeutic option for BAV patients is aortic valve replacement (AVR), but the role of improved post-AVR hemodynamics on aortopathy progression is also not well-understood. To address these issues, this study employs a computational fluid dynamics model to simulate personalized AAo hemodynamics before and after TAVR for a small cohort of 6 Left-Right fused BAV patients. Regional distributions of five hemodynamic metrics, namely, time-averaged wall shear stress (TAWSS) and oscillating shear index (OSI), divergence of wall shear (DWSS), helicity flux integral & endothelial cell activation potential (ECAP), which are hypothesized to be associated with potential aortic injury are computed in the root, proximal and distal ascending aorta. BAVs are characterized by strong, eccentric jets, with peak velocities exceeding 4 m/s and axially circulating flow away from the jets. Such conditions result in focused WSS loading along jet attachment regions on the lumen boundary and weaker, oscillating WSS on other regions. The jet attachment regions also show alternating streaks of positive and negative DWSS, which may increase risk for local tissue stretching. Large WSS magnitudes, strong helical flows and circumferential WSS have been previously implicated in the progression of BAV aortopathy. Post-intervention hemodynamics exhibit weaker, less eccentric jets. Significant reductions are observed in flow helicity, TAWSS and DWSS in localized regions of the proximal AAo. On the other hand, OSI increases post-intervention and ECAP is observed to be low in both pre- and post-intervention scenarios, although significant increases are also observed in this ECAP. These results indicate a significant alleviation of pathological hemodynamics post AVR.


Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Heart Valve Diseases/complications , Aorta/pathology , Aortic Valve/physiology , Hemodynamics/physiology , Stress, Mechanical
5.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article En | MEDLINE | ID: mdl-38608189

OBJECTIVES: Repair of the bicuspid aortic valve (BAV) has evolved in the past 25 years. The aim of this study was to review and analyse the long-term durability of isolated BAV repair with particular focus on commissural orientation (CO). METHODS: All patients who underwent BAV repair for severe aortic regurgitation between October 1998 and December 2022 were included. The study group consists of all patients operated after 2009, i.e. since CO modification. The control group includes patients who were operated before 2009. CO was classified as symmetric, asymmetric and very asymmetric. RESULTS: Overall, 594 adult patients (93% male; mean age 42 years) were included. At 15 years, survival was 94.8% [standard deviation (SD): 2.2]; freedom from reoperation was 86.8% (SD: 2.3). Freedom from aortic insufficiency ≥II was 70.8% (SD: 4.7) at 15 years. Modification of CO by sinus plication was performed in 200 (33.7%) instances. Using competing risks analysis, the absence of effective height measurement (P = 0.018), very asymmetric CO (P = 0.028), the presence of calcification (P < 0.001), the use of pericardial patch (P < 0.001), the use of subcommissural sutures (P < 0.001) and preoperative endocarditis (P = 0.005) were identified as independent predictors for reoperation. Follow-up was 97% complete (4228 patient-years); mean follow-up was 7 years (SD: 5). CONCLUSIONS: Isolated BAV repair leads to good survival and durability in all morphologic types if cusp repair is guided by effective height, suture annuloplasty is performed, and CO is modified using sinus plication in asymmetrical valves. Very asymmetrical valves may should be treated with a lower threshold for replacement.


Aortic Valve Insufficiency , Aortic Valve , Bicuspid Aortic Valve Disease , Humans , Male , Bicuspid Aortic Valve Disease/surgery , Aortic Valve/surgery , Aortic Valve/abnormalities , Adult , Female , Aortic Valve Insufficiency/surgery , Middle Aged , Retrospective Studies , Treatment Outcome , Reoperation/statistics & numerical data , Heart Valve Diseases/surgery , Young Adult , Follow-Up Studies
6.
Int J Cardiol ; 407: 132000, 2024 Jul 15.
Article En | MEDLINE | ID: mdl-38561108

AIM: To evaluate the association between raphe in bicuspid aortic valve (BAV) patients and valve dysfunction, aortopathy and aortic valve surgery in the REBECCA registry [REgistro della valvola aortica Bicuspide della Società Italiana di ECocardiografia e CArdiovascular Imaging (SIECVI)]. METHODS: Prevalence of aortic valve dysfunction and aortopathy was investigated in BAV patients with and without raphe. Aortic valve dysfunction (regurgitation or stenosis) was categorized as mild, moderate and severe. Aortopathy was defined as annulus ≥14 mm/m2; root ≥20 mm/m2; sinotubular junction ≥16 mm/m2; ascending aorta ≥17 mm/m2, and classified in Type A, isolated ascending aorta dilatation; Type B, aortic root and ascending aorta dilatation; and Type C, isolated aortic root dilatation. RESULTS: Overall, 695 patients with BAV were enrolled; 520 (74.8%) with raphe and 175 (25.2%) without raphe. BAV patients with raphe presented more frequently with moderate or severe aortic stenosis than BAV patients without raphe (183 [35.2%] vs 34 [19.4%], p < 0.001). A higher prevalence of aortopathy, particularly Type B, was observed in patients with vs without raphe. At multivariable analysis, raphe was a predictor of aortic valve surgery at three-year follow-up (odds ratio 2.19, 95% confidence interval 1.08-4.44, p < 0.001). CONCLUSIONS: Patients with BAV and raphe have a higher prevalence of significant aortic stenosis, aortopathy, especially Type B, and a higher risk of undergoing aortic valve surgery at three-year follow-up.


Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Registries , Humans , Male , Female , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/complications , Middle Aged , Aortic Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Heart Valve Diseases/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/complications , Aortic Diseases/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/epidemiology , Adult , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Follow-Up Studies , Italy/epidemiology
7.
Comput Methods Programs Biomed ; 250: 108173, 2024 Jun.
Article En | MEDLINE | ID: mdl-38615386

BACKGROUND AND OBJECTIVE: The conventional valve stents that are cylindrical in shape will become elliptical when implanted in bicuspid aortic valve, thereby reducing the durability of the artificial valve. In this study, a new design of valve stent is presented where valve stents have elliptical cross-section at the annulus and it is expected to have better expandability and circle shape during the interaction between the stent and bicuspid aortic valve, thereby extending the durability of artificial valve. METHODS: Finite element method (FEM) is used to study the mechanical behavior of the novel valve stent in the bicuspid aortic valve. The effects of three matching relationship between the ellipticity of the stents and the ellipticity of the annulus (i.e., the ellipticity of the stent is greater than, equal to and less than the annulus ellipticity, respectively) on the mechanical behavior of stent expansion are studied. In addition, the expansion mechanical behavior of the novel valve stent at different implantation depths is also compared. RESULTS: Results indicate that novel valve stent implantation with elliptical features is superior to conventional circular valve stent. When the novel valve stent ellipticity is less than the annulus ellipticity, the ellipticity of the novel valve stent after implantation is smaller than that of the conventional circular valve stent. This indicated that the novel valve stent has better expandability and post-expansion shape, making artificial valve to have better durability. The risk of paravalvular leak after implantation is lowest when the novel valve stent ellipticity is less than annulus ellipticity. When the novel valve stent ellipticity coincides with annulus ellipticity, the aortic wall is subjected to greatest stress. With the increase of implantation depth, the stress on the novel valve stent decrease. CONCLUSIONS: This study might provide insights for improving stent design for bicuspid aortic valve.


Aortic Valve , Bicuspid Aortic Valve Disease , Finite Element Analysis , Heart Valve Prosthesis , Prosthesis Design , Stents , Aortic Valve/abnormalities , Aortic Valve/surgery , Humans , Bicuspid Aortic Valve Disease/surgery , Stress, Mechanical , Heart Valve Diseases/surgery , Aortic Valve Disease/surgery
8.
Methodist Debakey Cardiovasc J ; 20(1): 18-22, 2024.
Article En | MEDLINE | ID: mdl-38618611

Gerbode defect, an anomalous connection between the left ventricle and right atrium, is often congenital but can be acquired or iatrogenically formed. We present an exceedingly rare case of this defect associated with multiple valve perforation in an otherwise healthy patient with bicuspid aortic valve and endocarditis.


Bicuspid Aortic Valve Disease , Endocarditis , Heart Septal Defects, Ventricular , Humans , Endocarditis/diagnostic imaging , Endocarditis/surgery , Health Status , Heart Atria
9.
Med Eng Phys ; 126: 104157, 2024 04.
Article En | MEDLINE | ID: mdl-38621853

Both ageing and hypertension are clinical factors that may lead to a higher propensity for dissection or rupture of ascending thoracic aortic aneurysms (ATAAs). This study sought to investigate effect of valve morphology on regional delamination strength of ATAAs in the elderly hypertensive patients. Whole fresh ATAA samples were harvested from 23 hypertensive patients (age, 71 ± 8 years) who underwent elective aortic surgery. Peeling tests were performed to measure region-specific delamination strengths of the ATAAs, which were compared between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). The regional delamination strengths of the ATAAs were further correlated with patient ages and aortic diameters for BAV and TAV groups. In the anterior and right lateral regions, the longitudinal delamination strengths of the ATAAs were statistically significantly higher for BAV patients than TAV patients (33 ± 7 vs. 23 ± 8 mN/mm, p = 0.01; 30 ± 7 vs. 19 ± 9 mN/mm, p = 0.02). For both BAV and TAV patients, the left lateral region exhibited significantly higher delamination strengths in both directions than the right lateral region. Histology revealed that disruption of elastic fibers in the right lateral region of the ATAAs was more severe for the TAV patients than the BAV patients. A strong inverse correlation between longitudinal delamination strength and age was identified in the right lateral region of the ATAAs of the TAV patients. Results suggest that TAV-ATAAs are more vulnerable to aortic dissection than BAV-ATAAs for the elderly hypertensive patients. Regardless of valve morphotypes, the right lateral region may be a special quadrant which is more likely to initiate dissection when compared with other regions.


Aortic Aneurysm, Thoracic , Aortic Aneurysm , Bicuspid Aortic Valve Disease , Hypertension , Humans , Aged , Middle Aged , Aortic Valve , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/pathology , Aorta/pathology , Aortic Aneurysm/pathology , Bicuspid Aortic Valve Disease/pathology , Hypertension/complications , Hypertension/pathology
10.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Article En | MEDLINE | ID: mdl-38577939

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Aortic Valve Stenosis , Balloon Valvuloplasty , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Retrospective Studies , Treatment Outcome , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Time Factors , Aged , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/mortality , Aged, 80 and over , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Recovery of Function , Hemodynamics , Risk Assessment
11.
Int J Mol Sci ; 25(5)2024 Feb 24.
Article En | MEDLINE | ID: mdl-38473887

Aortic aneurysms are a serious health concern as their rupture leads to high morbidity and mortality. Abdominal aortic aneurysms (AAAs) and thoracic aortic aneurysms (TAAs) exhibit differences and similarities in their pathophysiological and pathogenetic features. AAA is a multifactorial disease, mainly associated with atherosclerosis, characterized by a relevant inflammatory response and calcification. TAA is rarely associated with atherosclerosis and in some cases is associated with genetic mutations such as Marfan syndrome (MFS) and bicuspid aortic valve (BAV). MFS-related and non-genetic or sporadic TAA share aortic degeneration with endothelial-to-mesenchymal transition (End-Mt) and fibrosis, whereas in BAV TAA, aortic degeneration with calcification prevails. microRNA (miRNAs) contribute to the regulation of aneurysmatic aortic remodeling. miRNAs are a class of non-coding RNAs, which post-transcriptionally regulate gene expression. In this review, we report the involvement of deregulated miRNAs in the different aortic remodeling characterizing AAAs and TAAs. In AAA, miRNA deregulation appears to be involved in parietal inflammatory response, smooth muscle cell (SMC) apoptosis and aortic wall calcification. In sporadic and MFS-related TAA, miRNA deregulation promotes End-Mt, SMC myofibroblastic phenotypic switching and fibrosis with glycosaminoglycan accumulation. In BAV TAA, miRNA deregulation sustains aortic calcification. Those differences may support the development of more personalized therapeutic approaches.


Aortic Aneurysm, Thoracic , Aortic Aneurysm , Atherosclerosis , Bicuspid Aortic Valve Disease , Calcinosis , Marfan Syndrome , MicroRNAs , Humans , Aortic Valve/pathology , MicroRNAs/metabolism , Aortic Aneurysm/complications , Aortic Aneurysm, Thoracic/genetics , Marfan Syndrome/genetics , Calcinosis/pathology , Phenotype , Atherosclerosis/metabolism , Fibrosis
12.
Zhonghua Wai Ke Za Zhi ; 62(5): 393-399, 2024 May 01.
Article Zh | MEDLINE | ID: mdl-38548607

Objective: To examine the early to mid-term clinical outcomes of aortic valve repair in patients with bicuspid aortic insufficiency. Methods: This is a retrospective cohort study. The clinical data of 124 patients with BAV insufficiency who underwent aortic valve repair from January 2017 to June 2023 in the Department of Cardiovascular Surgery at Fuwai Hospital were analyzed retrospectively. There were 117 males and 7 females with an age of (38.1±12.7) years (range: 14 to 65 years). Depending on whether the aortic sinus was replaced or not, surgical approaches were divided into valve sparing root replacement (reimplantation, remodeling, modified remodeling) and isolated aortic valve repair (annuloplasty, isolated aortic valve leaflet repair). Perioperative and follow-up data were collected. Kaplan-Meier method was used to plot the curves of survival rate, free recurrence rate of massive aortic valve insufficiency and free re-operation rate, and Log-rank test was used for comparison between groups. Results: Among the surgeries, there were 47 cases of reimplantation, 8 cases of remodeling, 8 cases of modified remodeling, 48 cases of aortic annuloplasty (external annuloplasty in 22 cases, CV-0 annuloplasty in 26 cases), and 13 cases of isolated leaflet repair. Leaflet plication was the most used leaflet repair technique, used in 103 patients. The cardiopulmonary bypass time was (133.7±56.9) minutes (range: 48 to 461 minutes), and aortic cross-clamp time was (103.8±47.8) minutes (range: 25 to 306 minutes), with no surgical mortality. All patients underwent outpatient or telephone follow-up. The cumulative follow-up time was 340.3 person-years and the mean follow-up time was (M (IQR)) 34.0 (25.5) months (range: 3 to 76 months). The 5-year survival rate was 98.4%, the 5-year freedom from significant insufficiency rate was 93.4% and the 5-year freedom from aortic valve reoperation rate was 95.6%. The subgroup analysis revealed a significantly better freedom from the significant insufficiency rate in the aortic valve annular reduction group compared to the non-reduction group (P<0.01). Conclusions: Aortic valve repair in patients with bicuspid aortic insufficiency could obtain steady early to mid-term outcomes. Aortic annuloplasty can reduce the risk of recurrent aortic valve insufficiency in patients undergoing aortic repair.


Aortic Valve Insufficiency , Aortic Valve , Bicuspid Aortic Valve Disease , Humans , Male , Female , Adult , Retrospective Studies , Middle Aged , Bicuspid Aortic Valve Disease/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve/surgery , Aortic Valve/abnormalities , Adolescent , Young Adult , Treatment Outcome , Aged , Heart Valve Diseases/surgery , Cardiac Valve Annuloplasty/methods , Survival Rate
13.
J Am Heart Assoc ; 13(6): e032770, 2024 Mar 19.
Article En | MEDLINE | ID: mdl-38497457

BACKGROUND: Left atrial reservoir strain (LARS) is a novel imaging biomarker of left ventricular diastolic dysfunction. This study aimed to examine the prognostic implications of LARS in patients with bicuspid aortic valve and significant (moderate-severe to severe) aortic regurgitation. METHODS AND RESULTS: A total of 220 patients with bicuspid aortic valve and significant aortic regurgitation were prospectively enrolled in our study. LARS and left ventricular global longitudinal strain were derived from speckle-tracking echocardiography. The end point was a composite of all-cause mortality, heart failure hospitalization, and aortic valve repair or replacement. The threshold value of LARS <24% was used to identify impaired left atrial mechanics based on prior results. During a median follow-up of 364 (interquartile range, 294-752) days, 46 patients (20.9%) reached the composite end points. On multivariable Cox analysis, impaired LARS (adjusted hazard ratio, 2.08 [95% CI, 1.05-4.11]; P=0.036) was a statistically significant predictor of composite end points after adjustment for other statistically significant predictors. Finally, adding impaired LARS to other statistically significant predictors (New York Heart Association functional class and left ventricular global longitudinal strain) significantly improved the global χ2 (from 32.19 to 36.56; P=0.037) and reclassification (continuous net reclassification index=0.55; P<0.001) of the prediction model. CONCLUSIONS: In patients with bicuspid aortic valve and significant aortic regurgitation, the impairment of LARS is a strong independent prognostic predictor and confers incremental prognostic utility over clinical and other echocardiographic parameters. These findings suggest that LARS could be considered in risk stratification for such populations.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Ventricular Dysfunction, Left , Humans , Prognosis , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Heart Atria , Aortic Valve/diagnostic imaging , Ventricular Function, Left
14.
J Am Coll Cardiol ; 83(12): 1136-1146, 2024 Mar 26.
Article En | MEDLINE | ID: mdl-38508846

BACKGROUND: Aortic aneurysm is common in patients with coarctation of aorta (COA), but it is unclear whether the risk of aortic aneurysms is due to COA or related to the presence of other risk factors such as bicuspid aortic valve (BAV) and hypertension. OBJECTIVES: The purpose of this study was to assess the relationship among COA, BAV, and thoracic aortic aneurysms. METHODS: A total of 867 patients with COA (COA group) were matched 1:1:1 to 867 patients with isolated BAV (BAV group) and 867 patients without structural heart disease (SHD) (no-SHD group). The COA group was further subdivided into a COA+BAV subgroup (n = 304 [35%]), and COA with tricuspid aortic valve (TAV) (COA+TAV subgroup [n = 563 (65%)]). Aortic dimensions were assessed at baseline and at 3, 5, and 7 years. RESULTS: Compared with the no-SHD group, the COA+BAV subgroup had larger aortic root diameter (37 mm [Q1-Q3: 30-43 mm] vs 32 mm [Q1-Q3: 27-35 mm]; P < 0.001) and mid ascending aorta dimeter (34 mm [Q1-Q3: 29-40 mm] vs 28 mm [Q1-Q3: 24-31 mm]; P = 0.008). Similarly, the BAV group had larger aortic root diameter (37 mm [Q1-Q3: 30-42 mm] vs 32 mm [Q1-Q3: 27-35 mm]; P < 0.001), and mid ascending aorta dimeter (35 mm [Q1-Q3: 30-40 mm] vs 28 mm [Q1-Q3: 24-31 mm]; P < 0.001). Compared with the COA+TAV subgroup, the COA+BAV subgroup and BAV group were associated with larger aortic root and mid ascending aorta diameter at baseline and follow-up. The risk of acute aortic complications was low in all groups. CONCLUSIONS: These findings suggest that BAV (and not COA) was associated with ascending thoracic aorta dimensions, and that patients with COA+TAV were not at a greater risk of developing ascending aortic aneurysms as compared with patients without SHD.


Aneurysm, Ascending Aorta , Aortic Aneurysm , Aortic Coarctation , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Aortic Valve/diagnostic imaging , Aortic Coarctation/complications , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/epidemiology , Heart Valve Diseases/complications , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/epidemiology , Aortic Aneurysm/etiology
15.
J Cardiothorac Surg ; 19(1): 144, 2024 Mar 19.
Article En | MEDLINE | ID: mdl-38504348

BACKGROUND: We investigated long-term outcomes, particularly later aorta operations and overall death in patients who underwent aortic valve replacement for bicuspid aortic valve without aortic surgery. METHODS: Between January 2002 and December 2022, 274 patients underwent aortic valve replacement for bicuspid aortic valve at our institution. Of them, 181 patients who did not undergo aortic surgery, in accordance with current guidelines, were analyzed retrospectively. RESULTS: The median follow-up duration was 6.1 (2.0-10.6) years, and follow-up was completed in 97.8% of pateints. There were 3 patients (1.7%) who underwent later aorta operation during follow-up period. The cumulative later aorta operation rate at 10 years adjusting overall death as competing risk was 16.3%, and the estimated rates of freedom from overall death at 10 years was 83.7%. Fine-Gray competing risk regression model showed that aortic valve stenosis was only the predictor of later aorta operation (hazard ratio 8.477; p = 0.012). In multivariable Cox models, predictors of overall death were aortic valve stenosis (hazard ratio: 8.270, 95% confidence interval: 1.082-63.235; p = 0.042) and operation time (hazard ratio: 1.011, 95% confidence interval: 1.004-1.017; p = 0.002). CONCLUSIONS: Patients with bicuspid aortic valve with ascending aortic diameter less than 45 mm are at low risk of later aorta operation after isolated aortic valve replacement.


Aortic Aneurysm , Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Aortic Valve/surgery , Heart Valve Diseases/surgery , Retrospective Studies , Aortic Aneurysm/surgery , Treatment Outcome , Aortic Valve Stenosis/surgery , Aorta/surgery
16.
Comput Biol Med ; 172: 108191, 2024 Apr.
Article En | MEDLINE | ID: mdl-38457932

Bicuspid aortic valve (BAV), the most common congenital heart disease, is prone to develop significant valvular dysfunction and aortic wall abnormalities such as ascending aortic aneurysm. Growing evidence has suggested that abnormal BAV hemodynamics could contribute to disease progression. In order to investigate BAV hemodynamics, we performed 3D patient-specific fluid-structure interaction (FSI) simulations with fully coupled blood flow dynamics and valve motion throughout the cardiac cycle. Results showed that the hemodynamics during systole can be characterized by a systolic jet and two counter-rotating recirculation vortices. At peak systole, the jet was usually eccentric, with asymmetric recirculation vortices and helical flow motion in the ascending aorta. The flow structure at peak systole was quantified using the vorticity, flow rate reversal ratio and local normalized helicity (LNH) at four locations from the aortic root to the ascending aorta. The systolic jet was evaluated with the peak velocity, normalized flow displacement, and jet angle. It was found that peak velocity and normalized flow displacement (rather than jet angle) gave a strong correlation with the vorticity and LNH in the ascending aorta, which suggests that these two metrics could be used for clinical noninvasive evaluation of abnormal blood flow patterns in BAV patients.


Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Aortic Valve/abnormalities , Heart Valve Diseases/diagnostic imaging , Aorta , Hemodynamics/physiology
17.
BMJ Open ; 14(3): e067977, 2024 Mar 20.
Article En | MEDLINE | ID: mdl-38508639

OBJECTIVES: The objective of this study was to develop clinical classifiers aiming to identify prevalent ascending aortic dilatation in patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). DESIGN AND SETTING: A prospective, single-centre and observational cohort. PARTICIPANTS: The study involved 543 BAV and 491 TAV patients with aortic valve disease and/or ascending aortic dilatation, excluding those with coronary artery disease, undergoing cardiothoracic surgery at the Karolinska University Hospital (Sweden). MAIN OUTCOME MEASURES: Predictors of high risk of ascending aortic dilatation (defined as ascending aorta with a diameter above 40 mm) were identified through the application of machine learning algorithms and classic logistic regression models. EXPOSURES: Comprehensive multidimensional data, including valve morphology, clinical information, family history of cardiovascular diseases, prevalent diseases, demographic details, lifestyle factors, and medication. RESULTS: BAV patients, with an average age of 60.4±12.4 years, showed a higher frequency of aortic dilatation (45.3%) compared with TAV patients, who had an average age of 70.4±9.1 years (28.9% dilatation, p <0.001). Aneurysm prediction models for TAV patients exhibited mean area under the receiver-operating-characteristic curve (AUC) values above 0.8, with the absence of aortic stenosis being the primary predictor, followed by diabetes and high-sensitivity C reactive protein. Conversely, prediction models for BAV patients resulted in AUC values between 0.5 and 0.55, indicating low usefulness for predicting aortic dilatation. Classification results remained consistent across all machine learning algorithms and classic logistic regression models. CONCLUSION AND RECOMMENDATION: Cardiovascular risk profiles appear to be more predictive of aortopathy in TAV patients than in patients with BAV. This adds evidence to the fact that BAV-associated and TAV-associated aortopathy involves different pathways to aneurysm formation and highlights the need for specific aneurysm preventions in these patients. Further, our results highlight that machine learning approaches do not outperform classical prediction methods in addressing complex interactions and non-linear relations between variables.


Aneurysm , Aortic Diseases , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Middle Aged , Aged , Aortic Valve/surgery , Heart Valve Diseases/complications , Heart Valve Diseases/surgery , Prospective Studies , Dilatation , Aortic Diseases/complications
19.
Cardiovasc Revasc Med ; 63: 16-20, 2024 Jun.
Article En | MEDLINE | ID: mdl-38233251

BACKGROUND: There continues to be debate regarding the superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) in patients with bicuspid aortic valves (BAV). We aimed to compare outcomes during readmissions in elderly patients with BAV who underwent SAVR or TAVR. METHODS: Patients 65 years or older with BAV who underwent TAVR or isolated SAVR were identified using the National Readmission Database from 2012 through 2018. We compared outcomes during readmissions within 90 days after discharge from the index surgery. Propensity score matching was performed to adjust the baseline differences. RESULTS: During the study period, 8555 and 1081 elderly patients with BAV underwent SAVR and TAVR, respectively. The number of patients who underwent TAVR went up by 179 % from 2012 to 2018. Propensity score matching yielded 573 patients in each group. A total of 111 (19.4 %) in the SAVR group and 125 (21.8 %) in the TAVR group were readmitted within 90 days after the index surgery (p = .31). The mortality during the readmissions within 90 days was equivalent between the two groups (0.9 % in the SAVR group vs. 3.2 % in the TAVR group, p = .22). However, the median hospital cost was approximately doubled in the TAVR group during the readmission (18,250 dollars vs. 9310 dollars in the SAVR group, p < .001). CONCLUSIONS: Readmission within 90 days was common in both groups. While the mortality during the readmissions after the surgery was equivalent between the two groups, hospital cost was significantly more expensive in the TAVR group.


Aortic Valve , Bicuspid Aortic Valve Disease , Databases, Factual , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Patient Readmission , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/economics , Male , Female , Aged , Treatment Outcome , Time Factors , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/physiopathology , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Risk Factors , United States , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/economics , Retrospective Studies , Age Factors , Risk Assessment , Heart Valve Diseases/surgery , Heart Valve Diseases/mortality , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/physiopathology , Postoperative Complications/etiology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology
...