Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.506
Filter
1.
Curr Oncol ; 31(6): 3189-3198, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38920725

ABSTRACT

Women with left-sided breast cancer receiving adjuvant radiotherapy have increased incidence of cardiac mortality due to ischemic heart disease; to date, no threshold dose for late cardiac/pulmonary morbidity or mortality has been established. We investigated the likelihood of cardiac death and radiation pneumonitis in women with left-sided breast cancer who received comprehensive lymph node irradiation. The differences in dosimetric parameters between free-breathing (FB) and deep inspiration breath hold (DIBH) techniques were also addressed. Based on NTCP calculations, the probability of cardiac death was significantly reduced with the DIBH compared to the FB technique (p < 0.001). The risk of radiation pneumonitis was not clinically significant. There was no difference in coverage between FB and DIBH plans. Doses to healthy structures were significantly lower in DIBH plan than in FB plan for V20, V30, and ipsilateral total lung volume. Inspiratory gating reduces the dose absorbed by the heart without compromising the target range, thus reducing the likelihood of cardiac death.


Subject(s)
Unilateral Breast Neoplasms , Humans , Female , Unilateral Breast Neoplasms/radiotherapy , Middle Aged , Aged , Lymphatic Irradiation/methods , Radiotherapy Dosage , Radiotherapy, Adjuvant/methods , Adult , Breath Holding , Radiotherapy Planning, Computer-Assisted/methods , Lymph Nodes/pathology , Lymph Nodes/radiation effects
2.
Biomed Phys Eng Express ; 10(4)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38861951

ABSTRACT

Objective.We aim to: (1) quantify the benefits of lung sparing using non-adaptive magnetic resonance guided stereotactic body radiotherapy (MRgSBRT) with advanced motion management for peripheral lung cancers compared to conventional x-ray guided SBRT (ConvSBRT); (2) establish a practical decision-making guidance metric to assist a clinician in selecting the appropriate treatment modality.Approach.Eleven patients with peripheral lung cancer who underwent breath-hold, gated MRgSBRT on an MR-guided linear accelerator (MR linac) were studied. Four-dimensional computed tomography (4DCT)-based retrospective planning using an internal target volume (ITV) was performed to simulate ConvSBRT, which were evaluated against the original MRgSBRT plans. Metrics analyzed included planning target volume (PTV) coverage, various lung metrics and the generalized equivalent unform dose (gEUD). A dosimetric predictor for achievable lung metrics was derived to assist future patient triage across modalities.Main results.PTV coverage was high (median V100% > 98%) and comparable for both modalities. MRgSBRT had significantly lower lung doses as measured by V20 (median 3.2% versus 4.2%), mean lung dose (median 3.3 Gy versus 3.8 Gy) and gEUD. Breath-hold, gated MRgSBRT resulted in an average reduction of 47% in PTV volume and an average increase of 19% in lung volume. Strong correlation existed between lung metrics and the ratio of PTV to lung volumes (RPTV/Lungs) for both modalities, indicating that RPTV/Lungsmay serve as a good predictor for achievable lung metrics without the need for pre-planning. A threshold value of RPTV/Lungs< 0.035 is suggested to achieve V20 < 10% using ConvSBRT. MRgSBRT should otherwise be considered if the threshold cannot be met.Significance.The benefits of lung sparing using MRgSBRT were quantified for peripheral lung tumors; RPTV/Lungswas found to be an effective predictor for achievable lung metrics across modalities. RPTV/Lungscan assist a clinician in selecting the appropriate modality without the need for labor-intensive pre-planning, which has significant practical benefit for a busy clinic.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms , Lung , Magnetic Resonance Imaging , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiosurgery/methods , Lung Neoplasms/radiotherapy , Lung Neoplasms/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Lung/diagnostic imaging , Retrospective Studies , Four-Dimensional Computed Tomography/methods , Male , Female , Radiotherapy, Image-Guided/methods , Breath Holding , Aged , Middle Aged , Organ Sparing Treatments/methods , Organs at Risk
3.
Lakartidningen ; 1212024 Jun 05.
Article in Swedish | MEDLINE | ID: mdl-38836364

ABSTRACT

Witnessing breath-holding spells (BHS) can be distressing and patients with BHS disproportionately consume a substantial amount of health care resources. Common among preschool children, BHS follow a distinct sequence of events. A comprehensive patient history is the primary diagnostic tool. BHS lacked standardized diagnostic criteria and guidelines until our recent Acta Paediatrica publication. Studying 519 BHS cases in Skåne (years 2004-2018), we found overuse of electrocardiograms (ECGs) and electroencephalograms (EEGs), and underuse of blood tests for treatable iron deficiency and anemia, both known BHS contributors. Building upon our cohort analysis, we refined the definition of BHS and introduced a clinical management algorithm. Simulations showed reduced EEG and ECG use and an increase in blood tests. Our guideline not only streamlines diagnostic processes, but also optimizes the allocation of healthcare resources for more effective and targeted interventions.


Subject(s)
Algorithms , Breath Holding , Electrocardiography , Practice Guidelines as Topic , Humans , Child, Preschool , Electroencephalography , Infant , Anemia, Iron-Deficiency/diagnosis , Anemia, Iron-Deficiency/therapy , Child
4.
Magn Reson Med ; 92(3): 1138-1148, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38730565

ABSTRACT

PURPOSE: To develop a highly accelerated multi-echo spin-echo method, TEMPURA, for reducing the acquisition time and/or increasing spatial resolution for kidney T2 mapping. METHODS: TEMPURA merges several adjacent echoes into one k-space by either combining independent echoes or sharing one echo between k-spaces. The combined k-space is reconstructed based on compressed sensing theory. Reduced flip angles are used for the refocusing pulses, and the extended phase graph algorithm is used to correct the effects of indirect echoes. Two sequences were developed: a fast breath-hold sequence; and a high-resolution sequence. The performance was evaluated prospectively on a phantom, 16 healthy subjects, and two patients with different types of renal tumors. RESULTS: The fast TEMPURA method reduced the acquisition time from 3-5 min to one breath-hold (18 s). Phantom measurements showed that fast TEMPURA had a mean absolute percentage error (MAPE) of 8.2%, which was comparable to a standardized respiratory-triggered sequence (7.4%), but much lower than a sequence accelerated by purely k-t undersampling (21.8%). High-resolution TEMPURA reduced the in-plane voxel size from 3 × 3 to 1 × 1 mm2, resulting in improved visualization of the detailed anatomical structure. In vivo T2 measurements demonstrated good agreement (fast: MAPE = 1.3%-2.5%; high-resolution: MAPE = 2.8%-3.3%) and high correlation coefficients (fast: R = 0.85-0.98; high-resolution: 0.82-0.96) with the standardized method, outperforming k-t undersampling alone (MAPE = 3.3-4.5%, R = 0.57-0.59). CONCLUSION: TEMPURA provides fast and high-resolution renal T2 measurements. It has the potential to improve clinical throughput and delineate intratumoral heterogeneity and tissue habitats at unprecedented spatial resolution.


Subject(s)
Algorithms , Kidney Neoplasms , Kidney , Phantoms, Imaging , Humans , Kidney Neoplasms/diagnostic imaging , Kidney/diagnostic imaging , Magnetic Resonance Imaging/methods , Female , Adult , Male , Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Middle Aged , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Breath Holding
5.
Magn Reson Imaging ; 111: 138-147, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38729225

ABSTRACT

OBJECTIVES: To explore the potential and performance of quantitative and semi-quantitative parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on compressed sensing volumetric interpolated breath-hold (CS-VIBE) examination in the differential diagnosis of thyroid nodules. MATERIALS AND METHODS: A total of 208 patients with 259 thyroid nodules scheduled for surgery operation were prospectively recruited. All participants underwent routine and DCE-MRI. DCE-MRI quantitative parameters [Ktrans, Kep, Ve], semi-quantitative parameters [wash-in, wash-out, time to peak (TTP), arrival time (AT), peak enhancement intensity (PEI), and initial area under curve in 60 s (iAUC)] and time-intensity curve (TIC) types were analyzed. Differential diagnostic performances were assessed using area under the receiver operating characteristic curve (AUC) and compared with the Delong test. RESULTS: Ktrans, Kep, Ve, wash-in, wash-out, PEI and iAUC were statistically significantly different between malignant and benign nodules (P < 0.001). Among these parameters, ROC analysis revealed that Ktrans showed the highest diagnostic performance in the differentiation of benign and malignant nodules, followed by wash-in. ROC analysis also revealed that Ktrans achieved the best diagnostic performance for distinguishing papillary thyroid carcinoma (PTC) from non-PTC, follicular adenoma (FA) from non-FA, nodular goiter (NG) from non-NG, with AUC values of 0.854, 0.895 and 0.609, respectively. Type III curve is frequently observed in benign thyroid nodules, accounting for 77.4% (82/106). While malignant nodules are more common in type II, accounting for 57.5% (88/153). CONCLUSION: Thyroid examination using CS-VIBE based DCE-MRI is a feasible, non-invasive method to identify benign and malignant thyroid nodules and pathological types.


Subject(s)
Breath Holding , Contrast Media , Feasibility Studies , Magnetic Resonance Imaging , Thyroid Nodule , Humans , Male , Female , Thyroid Nodule/diagnostic imaging , Middle Aged , Adult , Magnetic Resonance Imaging/methods , Diagnosis, Differential , Aged , Prospective Studies , ROC Curve , Thyroid Gland/diagnostic imaging , Thyroid Gland/pathology , Image Interpretation, Computer-Assisted/methods , Young Adult , Reproducibility of Results , Image Enhancement/methods , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Sensitivity and Specificity
6.
Pediatr Neurol ; 156: 53-58, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38733854

ABSTRACT

BACKGROUND: Breath-holding spells are a benign condition primarily seen in 3% to 5% of healthy children aged between six months and five years. Although no specific treatment is recommended due to its benign nature, iron and piracetam are used in severe or recurrent cases. We planned to compare the heart rate variability (HRV) before and after treatment with 24-hour Holter monitoring in patients receiving iron and piracetam treatment and investigate the treatment's effectiveness. METHODS: Twenty-five patients who applied to the outpatient clinic between 2013 and 2015 due to breath-holding spells were included in the study. The patients who received piracetam and iron therapy and underwent 24-hour rhythm Holter monitoring were evaluated retrospectively. RESULTS: Fourteen (56%) of these patients were evaluated as having cyanotic-type and 11 (44%) patients were assessed as having pale-type breath-holding spells. A significant difference was found only between hourly peak heart rate and total power in the group receiving iron treatment. Significant differences were also found among the minimum heart rate, mean heart rate, the standard deviation of RR intervals, the mean square root of the sum of the squares of their difference between adjacent RR intervals, spectpow, and low frequency before and after the treatment in the patients who started piracetam treatment (P < 0.05). CONCLUSIONS: Our study is critical as it is the first to investigate the effects of treatment options on various HRV in patients with breath-holding spells. There were statistically significant changes in HRV parameters in patients receiving piracetam, and the number of attacks decreased significantly. Piracetam treatment contributes positively to the breath-holding spell with regard to efficacy and HRV, therefore it can be used to treat breath-holding spells.


Subject(s)
Breath Holding , Heart Rate , Piracetam , Humans , Heart Rate/drug effects , Heart Rate/physiology , Breath Holding/drug effects , Male , Female , Child, Preschool , Retrospective Studies , Infant , Piracetam/pharmacology , Piracetam/administration & dosage , Piracetam/therapeutic use , Electrocardiography, Ambulatory/drug effects , Treatment Outcome , Iron/administration & dosage , Iron/pharmacology
7.
PLoS One ; 19(5): e0296696, 2024.
Article in English | MEDLINE | ID: mdl-38722966

ABSTRACT

BACKGROUND: With recent advances in magnetic resonance imaging (MRI) technology, the practical role of lung MRI is expanding despite the inherent challenges of the thorax. The purpose of our study was to evaluate the current status of the concurrent dephasing and excitation (CODE) ultrashort echo-time sequence and the T1-weighted volumetric interpolated breath-hold examination (VIBE) sequence in the evaluation of thoracic disease by comparing it with the gold standard computed tomography (CT). METHODS: Twenty-four patients with lung cancer and mediastinal masses underwent both CT and MRI including T1-weighted VIBE and CODE. For CODE images, data were acquired in free breathing and end-expiratory images were reconstructed using retrospective respiratory gating. All images were evaluated through qualitative and quantitative approaches regarding various anatomical structures and lesions (nodule, mediastinal mass, emphysema, reticulation, honeycombing, bronchiectasis, pleural plaque and lymphadenopathy) inside the thorax in terms of diagnostic performance in making specific decisions. RESULTS: Depiction of the lung parenchyma, mediastinal and pleural lesion was not significant different among the three modalities (p > 0.05). Intra-tumoral and peritumoral features of lung nodules were not significant different in the CT, VIBE or CODE images (p > 0.05). However, VIBE and CODE had significantly lower image quality and poorer depiction of airway, great vessels, and emphysema compared to CT (p < 0.05). Image quality of central airways and depiction of bronchi were significantly better in CODE than in VIBE (p < 0.001 and p = 0.005). In contrast, the depiction of the vasculature was better for VIBE than CODE images (p = 0.003). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significant greater in VIBE than CODE except for SNRlung and SNRnodule (p < 0.05). CONCLUSIONS: Our study showed the potential of CODE and VIBE sequences in the evaluation of localized thoracic abnormalities including solid pulmonary nodules.


Subject(s)
Lung Neoplasms , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Female , Male , Middle Aged , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Aged , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods , Adult , Lung/diagnostic imaging , Lung/pathology , Retrospective Studies , Breath Holding
8.
Curr Sports Med Rep ; 23(5): 199-206, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38709946

ABSTRACT

ABSTRACT: Breath-hold divers, also known as freedivers, are at risk of specific injuries that are unique from those of surface swimmers and compressed air divers. Using peer-reviewed scientific research and expert opinion, we created a guide for medical providers managing breath-hold diving injuries in the field. Hypoxia induced by prolonged apnea and increased oxygen uptake can result in an impaired mental state that can manifest as involuntary movements or full loss of consciousness. Negative pressure barotrauma secondary to airspace collapse can lead to edema and/or hemorrhage. Positive pressure barotrauma secondary to overexpansion of airspaces can result in gas embolism or air entry into tissues and organs. Inert gas loading into tissues from prolonged deep dives or repetitive shallow dives with short surface intervals can lead to decompression sickness. Inert gas narcosis at depth is commonly described as an altered state similar to that experienced by compressed air divers. Asymptomatic cardiac arrhythmias are common during apnea, normally reversing shortly after normal ventilation resumes. The methods of glossopharyngeal breathing (insufflation and exsufflation) can add to the risk of pulmonary overinflation barotrauma or loss of consciousness from decreased cardiac preload. This guide also includes information for medical providers who are tasked with providing medical support at an organized breath-hold diving event with a list of suggested equipment to facilitate diagnosis and treatment outside of the hospital setting.


Subject(s)
Barotrauma , Breath Holding , Decompression Sickness , Diving , Humans , Diving/injuries , Diving/adverse effects , Barotrauma/etiology , Barotrauma/diagnosis , Decompression Sickness/therapy , Decompression Sickness/etiology , Decompression Sickness/diagnosis , Hypoxia/etiology , Inert Gas Narcosis/etiology , Inert Gas Narcosis/diagnosis
9.
Undersea Hyperb Med ; 51(1): 93-95, 2024.
Article in English | MEDLINE | ID: mdl-38615358

ABSTRACT

An arterial gas embolism (AGE) is a potentially fatal complication of scuba diving that is related to insufficient exhalation during ascent. During breath-hold diving, an arterial gas embolism is unlikely because the volume of gas in the lungs generally cannot exceed the volume at the beginning of the dive. However, if a diver breathes from a gas source at any time during the dive, they are at risk for an AGE or other pulmonary overinflation syndromes (POIS). In this case report, a breath-hold diver suffered a suspected AGE due to rapidly ascending without exhalation following breathing from an air pocket at approximately 40 feet.


Subject(s)
Diving , Embolism, Air , Humans , Embolism, Air/etiology , Breath Holding , Respiration , Diving/adverse effects , Exhalation
10.
Curr Sports Med Rep ; 23(4): 137-142, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38578491

ABSTRACT

ABSTRACT: Present-day diving comes in various forms, from utilizing sophisticated diving equipment to relying solely on one's ability to hold their breath. The diver and physician must be aware of the many common medical conditions and environmental considerations of this unique activity. While barotrauma remains the most common dive-related injury, injuries and accidents also are related to diving equipment-related accidents and exposure to marine flora and fauna. In addition, breath-hold diving, which includes free diving, snorkeling, and tasks, is an activity humans have done for thousands of years for recreation or survival. This article will update the dangers of diving and methods to prevent or treat injuries.


Subject(s)
Barotrauma , Diving , Humans , Diving/adverse effects , Diving/injuries , Barotrauma/etiology , Breath Holding
11.
Magn Reson Imaging ; 111: 15-20, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38579974

ABSTRACT

BACKGROUND: In patients who have difficulty holding their breath, a free breathing (FB) respiratory-triggered (RT) bSSFP cine technique may be used. However, this technique may have inferior image quality and a longer scan time than breath-hold (BH) bSSFP cine acquisitions. This study examined the effect of an audiovisual breathing guidance (BG) system on RT bSSFP cine image quality, scan time, and ventricular measurements. METHODS: This study evaluated a BG system that provides audiovisual instructions and feedback on the timing of inspiration and expiration to the patient during image acquisition using input from the respiratory bellows to guide them toward a regular breathing pattern with extended end-expiration. In this single-center prospective study in patients undergoing a clinical cardiac magnetic resonance examination, a ventricular short-axis stack of bSSFP cine images was acquired using 3 techniques in each patient: 1) FB and RT (FBRT), 2) BG system and RT (BGRT), and 3) BH. The 3 acquisitions were compared for image quality metrics (endocardial edge definition, motion artifact, and blood-to-myocardial contrast) scored on a Likert scale, scan time, and ventricular volumes and mass. RESULTS: Thirty-two patients (19 females; median age 21 years, IQR 18-32) completed the study protocol. For scan time, BGRT was faster than FBRT (163 s vs. 345 s, p < 0.001). Endocardial edge definition, motion artifact, and blood-to-myocardial contrast were all better for BGRT than FBRT (p < 0.001). Left ventricular (LV) end-systolic volume (ESV) was smaller (3%, p = 0.02) and LV ejection fraction (EF) was larger (0.5%, p = 0.003) with BGRT than with FBRT. There was no significant difference in LV end-diastolic volume (EDV), LV mass, right ventricular (RV) EDV, RV ESV, and RV EF. Scan times were shorter for BGRT compared to BH. Endocardial edge definition and blood-to-myocardial contrast were better for BH than BGRT. Compared to BH, the LV EDV, LV ESV, RV EDV, and RV ESV were mildly smaller (all differences <7%) for BGRT. CONCLUSIONS: The addition of a BG system to RT bSSFP cine acquisitions decreased the scan time and improved image quality. Further exploration of this BG approach is warranted in more diverse populations and with other free breathing sequences.


Subject(s)
Magnetic Resonance Imaging, Cine , Humans , Magnetic Resonance Imaging, Cine/methods , Female , Male , Adult , Prospective Studies , Respiration , Middle Aged , Respiratory-Gated Imaging Techniques/methods , Heart/diagnostic imaging , Heart Ventricles/diagnostic imaging , Breath Holding , Artifacts , Reproducibility of Results , Audiovisual Aids , Young Adult
12.
Br J Radiol ; 97(1158): 1162-1168, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38648776

ABSTRACT

OBJECTIVES: A portable respiratory training system with a gyroscope sensor (gyroscope respiratory training system [GRTS]) was developed and the feasibility of respiratory training was evaluated. METHODS: Simulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing expiratory breath-hold radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively. RESULTS: The absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.0%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 96.1% for free breathing and 88.2% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm and 91.0% (6.9) and 89.1% (11.6), respectively. CONCLUSIONS: Respiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold radiation therapy. ADVANCES IN KNOWLEDGE: A respiratory training system with a gyroscope sensor is inexpensive and portable, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.


Subject(s)
Feasibility Studies , Humans , Reproducibility of Results , Male , Adult , Phantoms, Imaging , Female , Breath Holding , Breathing Exercises/instrumentation , Breathing Exercises/methods , Middle Aged , Respiration , Equipment Design
13.
J Egypt Natl Canc Inst ; 36(1): 11, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38584227

ABSTRACT

BACKGROUND: The moderate deep inspiratory breath hold (mDIBH) is a modality famed for cardiac sparing. Prospective studies based on this are few from the eastern part of the world and India. We intend to compare the dosimetry between mDIBH and free-breathing (FB) plans. METHODS: Thirty-two locally advanced left breast cancer patients were taken up for the study. All patients received a dose of 50 Gy in 25 fractions to the chest wall/intact breast, followed by a 10-Gy boost to the lumpectomy cavity in the case of breast conservation surgery. All the patients were treated in mDIBH using active breath coordinator (ABC). The data from the two dose volume histograms were compared regarding plan quality and the doses received by the organs at risk. Paired t-test was used for data analysis. RESULTS: The dose received by the heart in terms of V5, V10, and V30 (4.55% vs 8.39%) and mean dose (4.73 Gy vs 6.74 Gy) were statistically significant in the ABC group than that in the FB group (all p-values < 0.001). Also, the dose received by the LADA in terms of V30 (19.32% vs 24.87%) and mean dose (32.99 Gy vs 46.65 Gy) were significantly less in the ABC group. The mean treatment time for the ABC group was 20 min, while that for the free-breathing group was 10 min. CONCLUSIONS: Incorporating ABC-mDIBH for left-sided breast cancer radiotherapy significantly reduces the doses received by the heart, LADA, and left and right lung, with no compromise in plan quality but with an increase in treatment time.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Female , Breath Holding , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/radiotherapy , Prospective Studies , Heart , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Organs at Risk
14.
Eur J Appl Physiol ; 124(7): 2183-2192, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38441687

ABSTRACT

Cardiovascular responses to diving are characterized by two opposing responses: tachycardia resulting from exercise and bradycardia resulting from the apnea. The convergence of bradycardia and tachycardia may determine the cardiovascular responses to diving. The purpose of this study was to investigate the interaction of breath holding and muscle mechanoreflex on cardiovascular responses in breath-hold divers (BHDs) and non-BHDs. We compared the cardiovascular responses to combined apnea and the mechanoreflex in BHDs and non-BHDs. All participants undertook three trials-apnea, passive leg cycling (PLC), and combined trials-for 30 s after rest. Cardiovascular variables were measured continuously. Nine BHD (male:female, 4:5; [means ± SD] age, 35 ± 6 years; height, 168.6 ± 4.6 cm; body mass, 58.4 ± 5.9 kg) and eight non-BHD (male:female, 4:4; [means ± SD] age, 35 ± 7 years; height, 163.9 ± 9.1 cm; body mass, 55.6 ± 7.2 kg) participants were included. Compared to the resting baseline, heart rate (HR) and cardiac output (CO) significantly decreased during the combined trial in the BHD group, while they significantly increased during the combined trials in the non-BHD group (P < 0.05). Changes in the HR and CO were significantly lower in the BHD group than in the non-BHD group in the combined trial (P < 0.05). These results suggest that bradycardia with apnea in BHDs is prioritized over tachycardia with the mechanoreflex, whereas that in non-BHDs is not. This finding implies that diving training changes the interaction between apnea and the mechanoreflex in cardiovascular control.


Subject(s)
Breath Holding , Diving , Heart Rate , Humans , Male , Female , Adult , Diving/physiology , Heart Rate/physiology , Muscle, Skeletal/physiology , Muscle, Skeletal/physiopathology , Apnea/physiopathology , Reflex/physiology , Cardiac Output/physiology , Diving Reflex/physiology , Blood Pressure/physiology
15.
Phys Med Biol ; 69(8)2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38479021

ABSTRACT

Objective. To provide three-dimensional (3D) whole-heart high-resolution isotropic cardiac T1 maps using a k-space-based through-plane super-resolution reconstruction (SRR) with rotated multi-slice stacks.Approach. Due to limited SNR and cardiac motion, often only 2D T1 maps with low through-plane resolution (4-8 mm) can be obtained. Previous approaches used SRR to calculate 3D high-resolution isotropic cardiac T1 maps. However, they were limited to the ventricles. The proposed approach acquires rotated stacks in long-axis orientation with high in-plane resolution but low through-plane resolution. This results in radially overlapping stacks from which high-resolution T1 maps of the whole heart are reconstructed using a k-space-based SRR framework considering the complete acquisition model. Cardiac and residual respiratory motion between different breath holds is estimated and incorporated into the reconstruction. The proposed approach was evaluated in simulations and phantom experiments and successfully applied to ten healthy subjects.Main results. 3D T1 maps of the whole heart were obtained in the same acquisition time as previous methods covering only the ventricles. T1 measurements were possible even for small structures, such as the atrial wall. The proposed approach provided accurate (P> 0.4;R2> 0.99) and precise T1 values (SD of 64.32 ± 22.77 ms in the proposed approach, 44.73 ± 31.9 ms in the reference). The edge sharpness of the T1 maps was increased by 6.20% and 4.73% in simulation and phantom experiments, respectively. Contrast-to-noise ratios between the septum and blood pool increased by 14.50% inin vivomeasurements with a k-space compared to an image-space-based SRR.Significance. The proposed approach provided whole-heart high-resolution 1.3 mm isotropic T1 maps in an overall acquisition time of approximately three minutes. Small structures, such as the atrial and right ventricular walls, could be visualized in the T1 maps.


Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods , Heart/diagnostic imaging , Heart Ventricles/diagnostic imaging , Breath Holding , Heart Atria , Phantoms, Imaging , Reproducibility of Results
16.
Med Phys ; 51(4): 2354-2366, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38477841

ABSTRACT

BACKGROUND: Cardiac radioablation is a noninvasive stereotactic body radiation therapy (SBRT) technique to treat patients with refractory ventricular tachycardia (VT) by delivering a single high-dose fraction to the VT isthmus. Cardiorespiratory motion induces position uncertainties resulting in decreased dose conformality. Electocardiograms (ECG) are typically used during cardiac MRI (CMR) to acquire images in a predefined cardiac phase, thus mitigating cardiac motion during image acquisition. PURPOSE: We demonstrate real-time cardiac physiology-based radiotherapy beam gating within a preset cardiac phase on an MR-linac. METHODS: MR images were acquired in healthy volunteers (n = 5, mean age = 29.6 years, mean heart-rate (HR) = 56.2 bpm) on the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) after obtaining written informed consent. The images were acquired using a single-slice balance steady-state free precession (bSSFP) sequence in the coronal or sagittal plane (TR/TE = 3/1.48 ms, flip angle = 48 ∘ $^{\circ }$ , SENSE = 1.5, field-of-view = 400 × 207 $\text{field-of-view} = {400}\times {207}$ mm 2 ${\text{mm}}^{2}$ , voxel size = 3 × 3 × 15 $3\times 3\times 15$ mm 3 ${\rm mm}^{3}$ , partial Fourier factor = 0.65, frame rate = 13.3 Hz). In parallel, a 4-lead ECG-signal was acquired using MR-compatible equipment. The feasibility of ECG-based beam gating was demonstrated with a prototype gating workflow using a Quasar MRI4D motion phantom (IBA Quasar, London, ON, Canada), which was deployed in the bore of the MR-linac. Two volunteer-derived combined ECG-motion traces (n = 2, mean age = 26 years, mean HR = 57.4 bpm, peak-to-peak amplitude = 14.7 mm) were programmed into the phantom to mimic dose delivery on a cardiac target in breath-hold. Clinical ECG-equipment was connected to the phantom for ECG-voltage-streaming in real-time using research software. Treatment beam gating was performed in the quiescent phase (end-diastole). System latencies were compensated by delay time correction. A previously developed MRI-based gating workflow was used as a benchmark in this study. A 15-beam intensity-modulated radiotherapy (IMRT) plan ( 1 × 6.25 ${1}\times {6.25}$ Gy) was delivered for different motion scenarios onto radiochromic films. Next, cardiac motion was then estimated at the basal anterolateral myocardial wall via normalized cross-correlation-based template matching. The estimated motion signal was temporally aligned with the ECG-signal, which were then used for position- and ECG-based gating simulations in the cranial-caudal (CC), anterior-posterior (AP), and right-left (RL) directions. The effect of gating was investigated by analyzing the differences in residual motion at 30, 50, and 70% treatment beam duty cycles. RESULTS: ECG-based (MRI-based) beam gating was performed with effective duty cycles of 60.5% (68.8%) and 47.7% (50.4%) with residual motion reductions of 62.5% (44.7%) and 43.9% (59.3%). Local gamma analyses (1%/1 mm) returned pass rates of 97.6% (94.1%) and 90.5% (98.3%) for gated scenarios, which exceed the pass rates of 70.3% and 82.0% for nongated scenarios, respectively. In average, the gating simulations returned maximum residual motion reductions of 88%, 74%, and 81% at 30%, 50%, and 70% duty cycles, respectively, in favor of MRI-based gating. CONCLUSIONS: Real-time ECG-based beam gating is a feasible alternative to MRI-based gating, resulting in improved dose delivery in terms of high γ -pass $\gamma {\text{-pass}}$ rates, decreased dose deposition outside the PTV and residual motion reduction, while by-passing cardiac MRI challenges.


Subject(s)
Radiosurgery , Radiotherapy, Intensity-Modulated , Humans , Adult , Magnetic Resonance Imaging , Breath Holding , Motion , Software , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage
17.
Magn Reson Imaging ; 109: 42-48, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38447629

ABSTRACT

PURPOSE: To evaluate the performance of high-resolution free-breathing (FB) hepatobiliary phase imaging of the liver using the eXtra-Dimension Golden-angle RAdial Sparse Parallel (XD-GRASP) MRI technique. METHODS: Fifty-eight clinical patients (41 males, mean age = 52.9 ± 12.9) with liver lesions who underwent dynamic contrast-enhanced MRI with a liver-specific contrast agent were prospectively recruited for this study. Both breath-hold volumetric interpolated examination (BH-VIBE) imaging and FB imaging were performed during the hepatobiliary phase. FB images were acquired using a stack-of-stars golden-angle radial sequence and were reconstructed using the XD-GRASP method. Two experienced radiologists blinded to acquisition schemes independently scored the overall image quality, liver edge sharpness, hepatic vessel clarity, conspicuity of lesion, and overall artifact level of each image. The non-parametric paired two-tailed Wilcoxon signed-rank test was used for statistical analysis. RESULTS: Compared to BH-VIBE images, XD-GRASP images received significantly higher scores (P < 0.05) for the liver edge sharpness (4.83 ± 0.45 vs 4.29 ± 0.46), the hepatic vessel clarity (4.64 ± 0.67 vs 4.15 ± 0.56) and the conspicuity of lesion (4.75 ± 0.53 vs 4.31 ± 0.50). There were no significant differences (P > 0.05) between BH-VIBE and XD-GRASP images for the overall image quality (4.61 ± 0.50 vs 4.74 ± 0.47) and the overall artifact level (4.13 ± 0.44 vs 4.05 ± 0.61). CONCLUSION: Compared to conventional BH-VIBE MRI, FB radial acquisition combined with XD-GRASP reconstruction facilitates higher spatial resolution imaging of the liver during the hepatobiliary phase. This enhancement can significantly improve the visualization and evaluation of the liver.


Subject(s)
Image Interpretation, Computer-Assisted , Respiration , Male , Humans , Adult , Middle Aged , Aged , Image Interpretation, Computer-Assisted/methods , Liver/diagnostic imaging , Magnetic Resonance Imaging/methods , Breath Holding , Contrast Media , Artifacts , Image Enhancement/methods , Imaging, Three-Dimensional/methods
18.
Eur J Radiol ; 175: 111445, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38537605

ABSTRACT

PURPOSE: To evaluate the feasibility of a free-breathing sequence (4D FreeBreathing) combined with Compressed SENSE in dynamic contrast-enhanced pancreatic MRI and compare it with a breath-holding sequence (eTHRIVE). METHOD: Patients who underwent pancreatic MRI, either eTHRIVE or 4D FreeBreathing, from April 2022 to November 2023 were included in this retrospective study. Two radiologists, who were unaware of the scan sequence, independently and randomly reviewed the images at the precontrast, pancreatic, portal venous, and equilibrium phases and assigned confidence scores for motion and streaking artifacts, pancreatic sharpness, and overall image quality using a 5-point scale. Furthermore, the radiologists assessed the appropriateness of the scan timing of the pancreatic phase. Mann-Whitney U and Fisher's exact tests were conducted to compare the confidence scores and adequacy of the pancreatic phase scan timing between eTHRIVE and 4D FreeBreathing. RESULTS: Overall, 48 patients (median age, 71 years; interquartile range, 64-77 years; 24 women) were included. Among them, 20 patients (42%) were scanned using 4D FreeBreathing. The 4D FreeBreathing showed moderate streaking artifact but improved motion artifact (P <.001-.17) at all phases. Pancreatic sharpness and overall image quality were almost comparable between two sequences (P = .17-.96). All 20 examinations in 4D FreeBreathing showed appropriate pancreatic phase images, but only 16 (57%; P <.001 for reviewer 1) and 18 (64%; P = .003 for reviewer 2) examinations showed it in eTHRIVE. CONCLUSION: The use of 4D FreeBreathing combined with Compressed SENSE was feasible in pancreatic MRI and provided appropriate pancreatic phase images in all examinations.


Subject(s)
Contrast Media , Feasibility Studies , Magnetic Resonance Imaging , Humans , Female , Male , Middle Aged , Aged , Retrospective Studies , Magnetic Resonance Imaging/methods , Artifacts , Respiration , Image Enhancement/methods , Breath Holding , Data Compression/methods , Pancreatic Neoplasms/diagnostic imaging , Pancreas/diagnostic imaging , Pancreatic Diseases/diagnostic imaging
19.
Radiat Oncol ; 19(1): 32, 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38459580

ABSTRACT

BACKGROUND: Centrally located lung tumours present a challenge because of their tendency to exhibit symptoms such as airway obstruction, atelectasis, and bleeding. Surgical resection of these tumours often requires sacrificing the lungs, making definitive radiotherapy the preferred alternative to avoid pneumonectomy. However, the proximity of these tumours to mediastinal organs at risk increases the potential for severe adverse events. To mitigate this risk, we propose a dual-method approach: deep inspiration breath-hold (DIBH) radiotherapy combined with adaptive radiotherapy. The aim of this single-centre, single-arm phase II study is to investigate the efficacy and safety of DIBH daily online adaptive radiotherapy. METHODS: Patients diagnosed with centrally located lung tumours according to the International Association for the Study of Lung Cancer recommendations, are enrolled and subjected to DIBH daily online adaptive radiotherapy. The primary endpoint is the one-year cumulative incidence of grade 3 or more severe adverse events, as classified by the Common Terminology Criteria for Adverse Events (CTCAE v5.0). DISCUSSION: Delivering definitive radiotherapy for centrally located lung tumours presents a dilemma between ensuring optimal dose coverage for the planning target volume and the associated increased risk of adverse events. DIBH provides measurable dosimetric benefits by increasing the normal lung volume and distancing the tumour from critical mediastinal organs at risk, leading to reduced toxicity. DIBH adaptive radiotherapy has been proposed as an adjunct treatment option for abdominal and pelvic cancers. If the application of DIBH adaptive radiotherapy to centrally located lung tumours proves successful, this approach could shape future phase III trials and offer novel perspectives in lung tumour radiotherapy. TRIAL REGISTRATION: Registered at the Japan Registry of Clinical Trials (jRCT; https://jrct.niph.go.jp/ ); registration number: jRCT1052230085 ( https://jrct.niph.go.jp/en-latest-detail/jRCT1052230085 ).


Subject(s)
Heart , Lung Neoplasms , Humans , Breath Holding , Organs at Risk , Lung Neoplasms/radiotherapy , Lung , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Clinical Trials, Phase II as Topic
20.
Acta Oncol ; 63: 56-61, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38404218

ABSTRACT

BACKGROUND AND PURPOSE: Proton therapy for breast cancer is usually given in free breathing (FB). With the use of deep inspiration breath-hold (DIBH) technique, the location of the heart is displaced inferiorly, away from the internal mammary nodes and, thus, the dose to the heart can potentially be reduced. The aim of this study was to explore the potential benefit of proton therapy in DIBH compared to FB for highly selected patients to reduce exposure of the heart and other organs at risk. We aimed at creating proton plans with delivery times feasible with treatment in DIBH. MATERIAL AND METHODS: Sixteen patients with left-sided breast cancer receiving loco-regional proton therapy were included. The FB and DIBH plans were created for each patient using spot-scanning proton therapy with 2-3 fields, robust and single field optimization. For the DIBH plans, minimum monitor unit per spot and spot spacing were increased to reduce treatment delivery time. RESULTS: All plans complied with target coverage constraints. The median mean heart dose was statistically significant reduced from 1.1 to 0.6 Gy relative biological effectiveness (RBE) by applying DIBH. No statistical significant difference was seen for mean dose and V17Gy RBE to the ipsilateral lung. The median treatment delivery time for the DIBH plans was reduced by 27% compared to the FB plans without compromising the plan quality. INTERPRETATION: The median absolute reduction in dose to the heart was limited. Proton treatment in DIBH may only be relevant for a subset of these patients with the largest reduction in heart exposure.


Subject(s)
Breast Neoplasms , Proton Therapy , Radiation Injuries , Unilateral Breast Neoplasms , Humans , Female , Breast Neoplasms/radiotherapy , Protons , Radiotherapy Dosage , Breath Holding , Radiotherapy Planning, Computer-Assisted/methods , Heart , Unilateral Breast Neoplasms/radiotherapy , Organs at Risk
SELECTION OF CITATIONS
SEARCH DETAIL
...