Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.542
Filter
1.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38874449

ABSTRACT

Ventricular backup leads may be considered in selected patients with His bundle pacing (HBP), but it remains unknown to what extent this is useful. A total of 184 HBP patients were studied. At last follow-up, 147 (79.9%) patients retained His bundle capture at programmed output. His bundle pacing lead revision was performed in 5/36 (13.9%) patients without a backup lead and in 3/148 (2.0%) patients with a backup lead (P = 0.008). One patient without a backup lead had syncope due to atrial oversensing. Thus, implantation of ventricular backup leads may avoid lead revision and adverse events in selected HBP patients.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Pacemaker, Artificial , Humans , Bundle of His/physiopathology , Male , Female , Cardiac Pacing, Artificial/methods , Aged , Treatment Outcome , Middle Aged , Aged, 80 and over , Retrospective Studies , Time Factors , Electrodes, Implanted
2.
Comput Methods Programs Biomed ; 253: 108239, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38823116

ABSTRACT

BACKGROUND: The excitable gap (EG), defined as the excitable tissue between two subsequent wavefronts of depolarization, is critical for maintaining reentry that underlies deadly ventricular arrhythmias. EG in the His-Purkinje Network (HPN) plays an important role in the maintenance of electrical wave reentry that underlies these arrhythmias. OBJECTIVE: To determine if rapid His bundle pacing (HBP) during reentry reduces the amount of EG in the HPN and ventricular myocardium to suppress reentry maintenance and/or improve defibrillation efficacy. METHODS: In a virtual human biventricular model, reentry was initiated with rapid line pacing followed by HBP delivered for 3, 6, or 9 s at pacing cycle lengths (PCLs) ranging from 10 to 300 ms (n=30). EG was calculated independently for the HPN and myocardium over each PCL. Defibrillation efficacy was assessed for each PCL by stimulating myocardial surface EG with delays ranging from 0.25 to 9 s (increments of 0.25 s, n=36) after the start of HBP. Defibrillation was successful if reentry terminated within 1 s after EG stimulation. This defibrillation protocol was repeated without HBP. To test the approach under different pathological conditions, all protocols were repeated in the model with right (RBBB) or left (LBBB) bundle branch block. RESULTS: Compared to without pacing, HBP for >3 seconds reduced average EG in the HPN and myocardium across a broad range of PCLs for the default, RBBB, and LBBB models. HBP >6 seconds terminated reentrant arrhythmia by converting HPN activation to a sinus rhythm behavior in the default (6/30 PCLs) and RBBB (7/30 PCLs) models. Myocardial EG stimulation during HBP increased the number of successful defibrillation attempts by 3%-19% for 30/30 PCLs in the default model, 3%-6% for 14/30 PCLs in the RBBB model, and 3%-11% for 27/30 PCLs in the LBBB model. CONCLUSION: HBP can reduce the amount of excitable gap and suppress reentry maintenance in the HPN and myocardium. HBP can also improve the efficacy of low-energy defibrillation approaches targeting excitable myocardium. HBP during reentrant arrhythmias is a promising anti-arrhythmic and defibrillation strategy.


Subject(s)
Bundle of His , Humans , Bundle of His/physiopathology , Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial/methods , Electric Countershock/methods , Heart Ventricles/physiopathology , Models, Cardiovascular
3.
J Electrocardiol ; 84: 161-164, 2024.
Article in English | MEDLINE | ID: mdl-38733733

ABSTRACT

Since the introduction of left bundle branch pacing (LBBP), a search for precise parameters confirming successful capture of conduction system was conducted. Most of the proposed electrocardiographic criteria refer to patients with narrow QRS complexes. We present a patient with heart failure in whom cardiac resynchronization was achieved using conduction system pacing. While measuring left ventricular activation time, an isoelectric interval of 74 ms between stimulus and R-wave appeared resulting in prolongation of V6 RWPT to 124 ms. Considering the immediate narrowing of QRS complexes following LBBP, the observed latency most probably reflects prolonged conduction time through the His-Purkinje system.


Subject(s)
Bundle-Branch Block , Electrocardiography , Heart Failure , Humans , Heart Failure/physiopathology , Heart Failure/therapy , Bundle-Branch Block/physiopathology , Bundle-Branch Block/therapy , Male , Cardiac Resynchronization Therapy/methods , Bundle of His/physiopathology , Heart Conduction System/physiopathology , Treatment Outcome , Aged , Middle Aged
4.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38703372

ABSTRACT

AIMS: To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). METHODS AND RESULTS: All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and at completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (left anterior oblique/right anterior oblique) and familiar landmarks is described. Using this, we resolved zonal distribution (I-VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with and without septal venous channel perforation were compared. Sixty-one patients {male 57.3%, median age [interquartile range (IQR)] 69.5 [62.5-74.5] years} were enrolled. Septal venous channel perforation was observed in eight (13.1%) patients [male 28.5%, median age (IQR) 64 (50-75) years]. They had higher frequency of (i) right-sided implant (25% vs. 1.9%, P = 0.04), (ii) fixation in zone III at the mid-superior septum (75% vs. 28.3%, P = 0.04), (iii) steeper angle of fixation-median θ (IQR) [19 (10-30)° vs. 5 (4-19)°, P = 0.01], and (iv) longer median penetrated-lead length (IQR) [13 (10-14.8) vs. 10 (8.5-12.5) mm, P = 0.03]. Coronary sinus drainage of contrast was noted in five (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, P = NS) were not significantly different. CONCLUSION: When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and is not associated with adverse consequence acutely or in early follow-up.


Subject(s)
Cardiac Pacing, Artificial , Humans , Male , Female , Prospective Studies , Middle Aged , Aged , Cardiac Pacing, Artificial/methods , Ventricular Septum/diagnostic imaging , Heart Injuries/etiology , Heart Injuries/diagnostic imaging , Treatment Outcome , Risk Factors , Bundle of His/physiopathology , Heart Septum/diagnostic imaging , Contrast Media , Fluoroscopy , Bundle-Branch Block/physiopathology , Bundle-Branch Block/etiology
5.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38753644

ABSTRACT

AIMS: Monitoring current of injury (COI) during left bundle branch area pacing (LBBAP) implantation is useful to evaluate lead depth. Technical aspects for recording COI amplitude have not been well studied. Our aims were to evaluate the impact of high-pass filter settings on electrogram recordings during LBBAP implantation. METHODS AND RESULTS: Consecutive patients with successful LBBAP implantation had unipolar recordings of COI at final lead position at different high-pass filter settings (0.01-1 Hz) from the tip electrode during sensing and pacing, and from the ring electrode during sensing. Duration of saturation-induced signal loss was also measured at each filter setting. COI amplitudes were compared between lumenless and stylet-driven leads. A total of 156 patients (96 males, aged 81.4 ± 9.6 years) were included. Higher filter settings led to significantly lower COI amplitudes. In 50 patients with COI amplitude < 10 mV, the magnitude of the drop was on average 1-1.5 mV (and up to 4 mV) between 0.05 and 0.5 Hz, meaning that cut-offs may not be used interchangeably. Saturation-induced signal loss was on average 10 s at 0.05 Hz and only 2 s with 0.5 Hz. When pacing was interrupted, the sensed COI amplitude varied (either higher or lower) by up to 4 mV, implying that it is advisable to periodically interrupt pacing to evaluate the sensed COI when reaching levels of ∼10 mV. Lead type did not impact COI amplitude. CONCLUSION: High-pass filters have a significant impact on electrogram characteristics at LBBAP implantation, with the 0.5 Hz settings having the most favourable profile.


Subject(s)
Cardiac Pacing, Artificial , Humans , Male , Female , Aged, 80 and over , Aged , Cardiac Pacing, Artificial/methods , Electrodes, Implanted , Electrophysiologic Techniques, Cardiac , Bundle of His/physiopathology , Pacemaker, Artificial , Equipment Design , Treatment Outcome , Action Potentials
6.
Eur Heart J Cardiovasc Imaging ; 25(7): 879-887, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38565632

ABSTRACT

Traditional right ventricular pacing (RVP) has been linked to the deterioration of both left ventricular diastolic and systolic function. This worsening often culminates in elevated rates of hospitalization due to heart failure, an increased risk of atrial fibrillation, and increased morbidity. While biventricular pacing (BVP) has demonstrated clinical and echocardiographic improvements in patients afflicted with heart failure and left bundle branch block, it has also encountered significant challenges such as a notable portion of non-responders and procedural failures attributed to anatomical complexities. In recent times, the interest has shifted towards conduction system pacing, initially, His bundle pacing, and more recently, left bundle branch area pacing, which are seen as promising alternatives to established methods. In contrast to other approaches, conduction system pacing offers the advantage of fostering more physiological and harmonized ventricular activation by directly stimulating the His-Purkinje network. This direct pacing results in a more synchronized systolic and diastolic function of the left ventricle compared with RVP and BVP. Of particular note is the capacity of conduction system pacing to yield a shorter QRS, conserve left ventricular ejection fraction, and reduce rates of mitral and tricuspid regurgitation when compared with RVP. The efficacy of conduction system pacing has also been found to have better clinical and echocardiographic improvement than BVP in patients requiring cardiac resynchronization. This review will delve into myocardial function in conduction system pacing compared with that in RVP and BVP.


Subject(s)
Cardiac Pacing, Artificial , Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Heart Failure/therapy , Heart Failure/physiopathology , Cardiac Pacing, Artificial/methods , Female , Male , Heart Conduction System/physiopathology , Bundle-Branch Block/therapy , Bundle-Branch Block/physiopathology , Echocardiography , Treatment Outcome , Bundle of His/physiopathology , Aged , Stroke Volume/physiology , Risk Assessment
7.
J Cardiovasc Med (Hagerstown) ; 25(6): 450-456, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38625833

ABSTRACT

BACKGROUND: Atrioventricular block (AVB) is a frequent complication in patients undergoing transcatheter aortic valve implantation (TAVI). Right apex ventricular pacing (RVP) represents the standard treatment but may induce cardiomyopathy over the long term. Left bundle branch area pacing (LBBAP) is a promising alternative, minimizing the risk of desynchrony. However, available evidence with LBBAP after TAVI is still low. OBJECTIVE: To assess the feasibility and safety of LBBAP for AVB post-TAVI compared with RVP. METHODS: Consecutive patients developing AVB early after TAVI were enrolled between 1 January 2022 and 31 December 2022 at three high-volume hospitals and received LBBAP or RVP. Data on procedure and at short-term follow-up (at least 3 months) were collected. RESULTS: A total of 38 patients (61% men, mean age 83 ±â€Š6 years) were included; 20 patients (53%) received LBBAP. Procedural success was obtained in all patients according to chosen pacing strategy. Electrical pacing performance at implant and after a mean follow-up of 4.2 ±â€Š2.8 months was clinically equivalent for both pacing modalities. In the LBBAP group, procedural time was longer (70 ±â€Š17 versus 58 ±â€Š15 min in the RVP group, P  = 0.02) and paced QRS was shorter (120 ±â€Š19 versus 155 ±â€Š12 ms at implant, P  < 0.001; 119 ±â€Š18 versus 157 ±â€Š9 ms at follow-up, P  < 0.001). Complication rates did not differ between the two groups. CONCLUSION: In patients with AVB after TAVI, LBBAP is feasible and safe, resulting in a narrow QRS duration, either acutely and during the follow-up, compared with RVP. Further studies are needed to evaluate if LBBAP reduces pacing-induced cardiomyopathy in this clinical setting.


Subject(s)
Aortic Valve Stenosis , Atrioventricular Block , Bundle of His , Cardiac Pacing, Artificial , Feasibility Studies , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Transcatheter Aortic Valve Replacement/adverse effects , Female , Aged, 80 and over , Aged , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Atrioventricular Block/diagnosis , Treatment Outcome , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Bundle of His/physiopathology , Time Factors , Latvia , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Heart Rate
8.
Pacing Clin Electrophysiol ; 47(7): 946-952, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38641952

ABSTRACT

INTRODUCTION: Concomitant left bundle branch area pacing (LBBAP) with atrioventricular (AV) nodal ablation is emerging as a viable management option in atrial fibrillation refractory to medical management. Its viability in patients with pulmonary disease and atrial fibrillation is unknown. METHODS AND RESULTS: This is a retrospective, observational cohort study in consecutive patients who underwent concomitant LBBAP with AV nodal ablation with advanced pulmonary disease at the Cleveland Clinic Fairview Hospital between January 2019 and January 2023. Patient characteristics, comorbidities, and medication use were extracted via chart review. Rates of hospitalizations, medication use, and structural disease seen on echocardiography were compared before and after the procedure. There were 27 patients with group 3 pulmonary hypertension who underwent the procedure. In the 24 months preprocedure, there were 114 admissions for heart failure or atrial fibrillation compared to 9 admissions postprocedure (p < .001). Mean follow up was 17.3 ± 12.1 months. There were no significant complications or lead dislodgements. Echocardiographic characteristics were similar prior to and after pacemaker implantation. Use of medications for rate and rhythm control was common preprocedure, and was reduced dramatically postprocedure. CONCLUSION: This small, retrospective cohort study suggests concomitant LBBAP with AV nodal ablation may be safe and efficacious for management of atrial fibrillation in patients with advanced pulmonary disease.


Subject(s)
Atrial Fibrillation , Atrioventricular Node , Humans , Atrial Fibrillation/surgery , Male , Female , Retrospective Studies , Aged , Atrioventricular Node/surgery , Atrioventricular Node/physiopathology , Middle Aged , Cardiac Pacing, Artificial , Catheter Ablation/methods , Lung Diseases/surgery , Bundle of His/physiopathology
11.
Ann Noninvasive Electrocardiol ; 29(3): e13113, 2024 May.
Article in English | MEDLINE | ID: mdl-38563226

ABSTRACT

The anatomy of the His-Purkinje system has been studied, yet there remains a knowledge gap regarding the impact of His bundle pacing and its electrocardiographic implications. This case report highlights the presence of His-Purkinje system pathology without apparent clues on the surface electrocardiogram (EKG). By observing identical QRS morphology with varying HV intervals resulting from different pacing outputs, we demonstrate the presence of an electrical propagation block within the His bundle.


Subject(s)
Bundle of His , Purkinje Fibers , Humans , Electrocardiography/methods , Cardiac Pacing, Artificial/methods
12.
J Cardiovasc Electrophysiol ; 35(6): 1235-1241, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38587994

ABSTRACT

INTRODUCTION: Catheter ablation of ectopy originating from the vicinity of the His bundle can be challenging. METHODS AND RESULTS: We report a case of a 33-year-old man with narrow QRS ectopy with preferential conduction from a para-Hisian origin to the proximal left fascicles, which was successfully eliminated by radiofrequency ablation in the right coronary cusp, guided by ultrahigh-resolution mapping of the His bundle, bundle branch, and fascicular electrograms. CONCLUSION: Some narrow QRS ectopy may originate from the vicinity of the conduction system, instead of the "true" conduction system, and have concealed connections from its origin to the conduction system.


Subject(s)
Action Potentials , Bundle of His , Catheter Ablation , Electrocardiography , Electrophysiologic Techniques, Cardiac , Heart Rate , Humans , Male , Adult , Bundle of His/physiopathology , Bundle of His/surgery , Treatment Outcome , Predictive Value of Tests
14.
Pacing Clin Electrophysiol ; 47(6): 771-775, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38576198

ABSTRACT

BACKGROUND: His bundle pacing (HBP) engaged electrical activation of both ventricles by stimulating the His-Purkinje network, which could avoid marked ventricles dyssynchrony. The lead was given three to five clockwise rotations at the site with the His potential to anchor the interventricular septum. In 2018, the Multicenter His Bundle Pacing Collaborative Working Group recommended that the His bundle capture threshold should be lower than 2.5 V/1 ms in non-pacing-dependent patients, and pacing-dependent patients should have a lower adjacent ventricular capture threshold as self-backup. Therefore, to avoid safety issues such as loss of capture caused by increased threshold, we believe that more stringent criteria should be adopted in patients with atrioventricular block (AVB). In previous studies, the connection cable needed to be disconnected during the screwing. When the procedure was finished, the performer found that the patients with His bundle injury could obtain a lower threshold than those without His bundle injury. Although no studies of new bundle branch block (BBB) or AVB by the acute His bundle injury was reported. However, It is worrying that the damage of His bundle seems random during the procedure. How to balance avoiding severe injury with a lower capture threshold? At present, we report a case of light His injury and lower His capture threshold under continuous intracardiac electrocardiogram monitoring.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Electrocardiography , Bundle of His/physiopathology , Humans , Cardiac Pacing, Artificial/methods , Male , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Aged , Bundle-Branch Block/therapy , Bundle-Branch Block/physiopathology
17.
JACC Clin Electrophysiol ; 10(6): 1120-1131, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38551549

ABSTRACT

BACKGROUND: Catheter ablation is the curative treatment for paroxysmal supraventricular tachycardia (SVT). However, atrial tachycardia (AT) diagnosis is often challenging, especially when SVT is terminated by pacing. OBJECTIVES: This study sought to develop a novel method for AT diagnosis. METHODS: A total of 147 SVTs including 28 ATs, 87 atrioventricular nodal re-entrant tachycardias, and 32 orthodromic reciprocating tachycardias were prospectively studied. Single atrial extrastimulation was performed at the proximal coronary sinus from a coupling interval 20 milliseconds shorter than the tachycardia cycle length and gradually decreased until the His bundle (HB) was first reset and further until the SVT was terminated. The response of the SVT during the first HB resetting and the termination pattern were examined. RESULTS: In 27 of 28 ATs, tachycardia was unaffected when HB resetting whereas, in atrioventricular nodal re-entrant tachycardias or orthodromic reciprocating tachycardias (non-AT), tachycardia was simultaneously reset when HB resetting or was terminated with an atrio-Hisian block. When the coupling interval was further shortened for cases in which tachycardia persisted, all 33 SVTs with tachycardia termination with atrio-Hisian block were non-ATs, whereas 5 ATs and 7 non-ATs were terminated with Hisian-atrial block. The sensitivity, specificity, and positive and negative predictive values of the pattern of tachycardia that was unaffected when HB resetting for AT diagnosis were 96%, 100%, 100%, and 99%, respectively. Those of the pattern of tachycardia termination with atrio-Hisian block for non-AT diagnosis were 92%, 100%, 100%, and 42%, respectively. CONCLUSIONS: Single atrial extrastimulation from the proximal coronary sinus during tachycardia was useful and effective for AT diagnosis.


Subject(s)
Bundle of His , Tachycardia, Supraventricular , Humans , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/therapy , Bundle of His/physiopathology , Male , Female , Middle Aged , Aged , Prospective Studies , Adult , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Catheter Ablation/methods , Electrocardiography , Heart Atria/physiopathology
19.
Pacing Clin Electrophysiol ; 47(4): 525-532, 2024 04.
Article in English | MEDLINE | ID: mdl-38430478

ABSTRACT

INTRODUCTION: The optimal slow pathway (SP) ablation site in cases with an inferiorly located His bundle (HIS) remains unclear. METHODS AND RESULTS: In 45 patients with atrioventricular nodal reentrant tachycardia, the relationship between the HIS location and successful SP ablation site was assessed in electroanatomical maps. We assessed the location of the SP ablation site relative to the bottom of the coronary sinus ostium in the superior-to-inferior (SPSI), anterior-to-posterior (SPAP), and right-to-left (SPRL) directions. The HIS location was assessed in the same manner. The HIS location in the superior-to-inferior direction (HISSI), SPSI, SPAP, and SPRL were 17.7 ± 6.4, 1.7 ± 6.4, 13.6 ± 12.3, and -1.0 ± 13.0 mm, respectively. The HISSI was positively correlated with SPSI (R2 = 0.62; P < .01) and SPAP (R2 = 0.22; P < .01), whereas it was not correlated with SPRL (R2 = 0.01; P = .65). The distance between the HIS and SP ablation site was 17.7 ± 6.4 mm and was not affected by the location of HIS. The ratio of the amplitudes of atrial and ventricular potential recorded at the SP ablation site did not differ between the high HIS group (HISSI ≥ 13 mm) and low HIS group (HISSI < 13 mm) (0.10 ± 0.06 vs. 0.10 ± 0.06; P = .38). CONCLUSION: In cases with an inferiorly located HIS, SP ablation should be performed at a lower and more posterior site than in typical cases.


Subject(s)
Tachycardia, Atrioventricular Nodal Reentry , Ventricular Septum , Humans , Bundle of His/surgery , Tachycardia, Atrioventricular Nodal Reentry/surgery , Heart Ventricles , Heart Atria
20.
Cardiovasc Pathol ; 70: 107626, 2024.
Article in English | MEDLINE | ID: mdl-38458505

ABSTRACT

Iatrogenic damage to the cardiac conduction system (CCS) remains a significant risk during congenital heart surgery. Current surgical best practice involves using superficial anatomical landmarks to locate and avoid damaging the CCS. Prior work indicates inherent variability in the anatomy of the CCS and supporting tissues. This study introduces high-resolution, 3D models of the CCS in normal pediatric human hearts to evaluate variability in the nodes and surrounding structures. Human pediatric hearts were obtained with an average donor age of 2.7 days. A pipeline was developed to excise, section, stain, and image atrioventricular (AVN) and sinus nodal (SN) tissue regions. A convolutional neural network was trained to enable precise multi-class segmentation of whole-slide images, which were subsequently used to generate high- resolution 3D tissue models. Nodal tissue region models were created. All models (10 AVN, 8 SN) contain tissue composition of neural tissue, vasculature, and nodal tissues at micrometer resolution. We describe novel nodal anatomical variations. We found that the depth of the His bundle in females was on average 304 µm shallower than those of male patients. These models provide surgeons with insight into the heterogeneity of the nodal regions and the intricate relationships between the CCS and surrounding structures.


Subject(s)
Atrioventricular Node , Imaging, Three-Dimensional , Humans , Female , Male , Infant, Newborn , Atrioventricular Node/anatomy & histology , Models, Cardiovascular , Sinoatrial Node/anatomy & histology , Bundle of His/physiopathology , Neural Networks, Computer , Sex Factors , Age Factors , Heart Conduction System/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...