Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 14.667
1.
Sci Rep ; 14(1): 10502, 2024 05 07.
Article En | MEDLINE | ID: mdl-38714849

We aimed to conduct a proof-of-concept study of INV-001 in visualizing lymphatic vessels and nodes without venous contamination and to determine the optimal dose condition of INV-001 for magnetic resonance lymphangiography (MRL) in healthy beagles. MRL was performed using a 3.0-Tesla (T) whole body clinical magnetic resonance imaging (MRI) scanner. A dose-finding study of INV-001 for MRL in beagles (N = 6) was carried out according to an adaptive optimal dose finding design. For the reproducibility study (N = 6), MRL was conducted at selected INV-001 doses (0.056 and 0.112 mg Fe/kg) with a 15 mM concentration. Additionally, an excretion study (N = 3) of INV-001 was conducted by analyzing T1, T2, and T2* maps of the liver and kidney 48 h post-administration. INV-001 administration at doses of 0.056 and 0.112 mg Fe/kg (concentration: 15 mM) consistently demonstrated the visualization of contrast-enhanced lymphatic vessels and nodes without venous contamination in the beagles. The contrast enhancement effect was highest at 30 min after INV-001 administration, then gradually decreasing. No toxicity-related issues were identified during the study. After 48 h, the T1, T2, and T2* values in the liver and both kidneys were found to be comparable to the pre-administration values, indicating thorough INV-001 excretion. The optimal dosing conditions of INV-001 for MRL for contrast-enhanced visualization of lymphatic vessels and nodes exclusively with no venous contamination in beagles was determined to be 0.056 mg Fe/kg with a 15 mM concentration.


Contrast Media , Lymphatic Vessels , Lymphography , Magnetic Resonance Imaging , Animals , Dogs , Magnetic Resonance Imaging/methods , Lymphography/methods , Contrast Media/administration & dosage , Lymphatic Vessels/diagnostic imaging , Male , Reproducibility of Results , Female , Lymph Nodes/diagnostic imaging , Proof of Concept Study
2.
World J Gastroenterol ; 30(17): 2311-2320, 2024 May 07.
Article En | MEDLINE | ID: mdl-38813054

Contrast-enhanced endoscopic ultrasound (CH-EUS) can overcome the limitations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of these tumours. Despite the initial enthusiasm that oriented needle sampling under CH-EUS guidance could provide better diagnostic yield in pancreatic solid lesions, further studies did not confirm the supplementary values in cases of tissue acquisition guided by CH-EUS. This review details the knowledge based on the available data on contrast-guided procedures. The indications for CH-EUS tissue acquisition include isoechoic EUS lesions with poor visible delineation where CH-EUS can differentiate the lesion vascularisation from the surrounding parenchyma and also the mural nodules within biliopancreatic cystic lesions, which occur in select cases. Additionally, the roles of CH-EUS-guided therapy in patients whose pancreatic fluid collections or bile ducts that have an echogenic content have indications for drainage, and patients who have nonvisualized vessels that need to be highlighted via Doppler EUS are presented. Another indication is represented if there is a need for an immediate assessment of the post-radiofrequency ablation of pancreatic neuroendocrine tumours, in which case CH-EUS can be used to reveal the incomplete tumour destruction.


Contrast Media , Endosonography , Pancreatic Neoplasms , Humans , Contrast Media/administration & dosage , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/surgery , Pancreatic Neoplasms/pathology , Endosonography/methods , Pancreas/diagnostic imaging , Pancreas/surgery , Pancreas/blood supply , Pancreas/pathology , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Ultrasonography, Interventional/methods , Drainage/methods , Pancreatic Diseases/diagnostic imaging , Pancreatic Diseases/surgery , Pancreatic Diseases/pathology
3.
World J Surg Oncol ; 22(1): 145, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38822338

BACKGROUND: The detection of renal cell carcinoma (RCC) has been rising due to the enhanced utilization of cross-sectional imaging and incidentally discovered lesions with adverse pathology demonstrate potential for metastasis. The purpose of our study was to determine the clinical and multiparametric dynamic contrast-enhanced magnetic resonance imaging (CEMRI) associated independent predictors of adverse pathology for cT1/2 RCC and develop the predictive model. METHODS: We recruited 105 cT1/2 RCC patients between 2018 and 2022, all of whom underwent preoperative CEMRI and had complete clinicopathological data. Adverse pathology was defined as RCC patients with nuclear grade III-IV; pT3a upstage; type II papillary RCC, collecting duct or renal medullary carcinoma, unclassified RCC; sarcomatoid/rhabdoid features. The qualitative and quantitative CEMRI parameters were independently reviewed by two radiologists. Univariate and multivariate binary logistic regression analyses were utilized to determine the independent predictors of adverse pathology for cT1/2 RCC and construct the predictive model. The receiver operating characteristic (ROC) curve, confusion matrix, calibration plot, and decision curve analysis (DCA) were conducted to compare the diagnostic performance of different predictive models. The individual risk scores and linear predicted probabilities were calculated for risk stratification, and the Kaplan-Meier curve and log-rank tests were used for survival analysis. RESULTS: Overall, 45 patients were pathologically confirmed as RCC with adverse pathology. Clinical characteristics, including gender, and CEMRI parameters, including RENAL score, tumor margin irregularity, necrosis, and tumor apparent diffusion coefficient (ADC) value were identified as independent predictors of adverse pathology for cT1/2 RCC. The clinical-CEMRI predictive model yielded an area under the curve (AUC) of the ROC curve of 0.907, which outperformed the clinical model or CEMRI signature model alone. Good calibration, better clinical usefulness, excellent risk stratification ability of adverse pathology and prognosis were also achieved for the clinical-CEMRI predictive model. CONCLUSIONS: The proposed clinical-CEMRI predictive model offers the potential for preoperative prediction of adverse pathology for cT1/2 RCC. With the ability to forecast adverse pathology, the predictive model could significantly benefit patients and clinicians alike by providing enhanced guidance for treatment planning and decision-making.


Carcinoma, Renal Cell , Contrast Media , Kidney Neoplasms , Humans , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/pathology , Carcinoma, Renal Cell/surgery , Female , Male , Kidney Neoplasms/pathology , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/surgery , Middle Aged , Contrast Media/administration & dosage , Aged , Retrospective Studies , Prognosis , Multiparametric Magnetic Resonance Imaging/methods , Follow-Up Studies , Neoplasm Staging , ROC Curve , Adult , Magnetic Resonance Imaging/methods
4.
West J Emerg Med ; 25(3): 342-344, 2024 May.
Article En | MEDLINE | ID: mdl-38801039

Introduction: During the coronavirus 2019 pandemic, hospitals in the United States experienced a shortage of contrast agent, much of which is manufactured in China. As a result, there was a significantly decreased amount of intravenous (IV) contrast available. We sought to determine the effect of restricting the use of IV contrast on emergency department (ED) length of stay (LOS). Methods: We conducted a single-institution, retrospective cohort study on adult patients presenting with abdominal pain to the ED from March 7-July 5, 2022. Of 26,122 patient encounters reviewed, 3,028 (11.6%) included abdominopelvic CT with a complaint including "abdominal pain." We excluded patients with outside imaging and non-ED scans. Routine IV contrast agent was administered to approximately 74.6% of patients between March 7-May 6, 2022, when we altered usage guidelines due to a nationwide shortage. Between May 6-July 5, 2022, 32.8% of patients received IV contrast after institutional recommendations were made to limit contrast use. We compared patient demographics and clinical characteristics between groups with chi-square test for frequency data. We analyzed ED LOS with nonparametric Wilcoxon rank-sum test for continuous measures with focus before and after new ED protocols. We also used statistical process control charts and plotted the 1, 2 and 3 sigma control limits to visualize the variation in ED LOS over time. The charts include the average (mean) of the data and upper and lower control limits, corresponding to the number of standard deviations away from the mean. Results: After use of routine IV contrast was discontinued, ED LOS (229.0 vs 212.5 minutes, P = <0.001) declined by 16.5 minutes (95% confidence interval -10, -22). Conclusion: Intravenous contrast adds significantly to ED LOS. Decreased use of routine IV contrast in the ED accelerates time to CT completion. A policy change to limit IV contrast during a national shortage significantly decreased ED LOS.


COVID-19 , Contrast Media , Emergency Service, Hospital , Length of Stay , Tomography, X-Ray Computed , Humans , Emergency Service, Hospital/statistics & numerical data , Contrast Media/administration & dosage , Retrospective Studies , COVID-19/epidemiology , Tomography, X-Ray Computed/statistics & numerical data , Female , Male , Middle Aged , Length of Stay/statistics & numerical data , United States , Administration, Intravenous , Adult , Abdominal Pain/diagnostic imaging , SARS-CoV-2 , Pandemics , Aged
5.
Clin Cardiol ; 47(5): e24282, 2024 May.
Article En | MEDLINE | ID: mdl-38801137

BACKGROUND: Ultra-low contrast administration during coronary angiography has been previously shown to be feasible and safe among patients with stable chronic kidney disease. In the present study, we investigate the safety of ultra-low contrast coronary angiography in patients with pre-existing acute kidney injury (AKI). METHODS: The study was a retrospective single-center evaluation of hospitalized patients who had AKI and required coronary angiography. Ultra-low contrast use was defined as ≤18 mL of contrast media. RESULTS: The cohort consisted of a case series of eight inpatients with AKI who required coronary angiography. The mean age was 57 (±16) years and half were females. All patients had chronic kidney disease with a mean baseline estimated glomerular filtration rate of 34 (±17) mL/min/1.73 m2. The mean creatinine before angiography was 3 (±1) mg/dL and volume of contrast administered was 14 (±4) mL. One patient had a 0.1 mg/dL increase in creatinine during admission, and no patients had further AKI up to 1-week postprocedure. CONCLUSIONS: The current data suggest that ultra-low contrast coronary angiography can be safely performed in patients with pre-existing AKI The study should be viewed as hypothesis-generating due to its small sample size. A larger cohort is required to validate the results.


Acute Kidney Injury , Contrast Media , Coronary Angiography , Glomerular Filtration Rate , Humans , Acute Kidney Injury/diagnosis , Coronary Angiography/methods , Female , Contrast Media/administration & dosage , Contrast Media/adverse effects , Male , Middle Aged , Retrospective Studies , Aged , Creatinine/blood , Coronary Artery Disease/diagnosis , Coronary Artery Disease/complications , Risk Factors , Adult
6.
Eur J Obstet Gynecol Reprod Biol ; 297: 233-240, 2024 06.
Article En | MEDLINE | ID: mdl-38696910

Transvaginal ultrasound is effective in diagnosing endometriosis involving the rectosigmoid bowel. Some authors suggest enhanced detection of rectosigmoid involvement with bowel preparation. Conversely, conflicting views argue that bowel preparation may not improve diagnostic precision, yielding similar results to rectal water contrast. No existing meta-analysis compares these approaches. Our study aims to conduct a meta-analysis to evaluate the diagnostic performance of transvaginal ultrasound with bowel preparation, with and without rectal water contrast. Studies published between 2000 and 2023 were searched in PubMed, Scopus, Cochrane and Web of Science. From 561 citations, we selected nine studies to include in this meta-analysis. The study quality was assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2). The mean prevalence of endometriosis rectosigmoid was 43.6% (range 17,56-76,66%) in the group with bowel preparation and 64,80% (50,0-83,60%) for the group with bowel preparation and rectal water contrast. Pooled sensitivity and specificity were 93% and 94% for bowel preparation and 92% and 95% and for bowel preparation with water contrast. We conclude that, there was no significant difference between performing transvaginal ultrasound with intestinal preparation with and without water contrast. In clinical practice, the absence of a significant difference between these methods should be taken into account when making recommendations.


Endometriosis , Ultrasonography , Humans , Endometriosis/diagnostic imaging , Female , Ultrasonography/methods , Contrast Media/administration & dosage , Sigmoid Diseases/diagnostic imaging , Rectal Diseases/diagnostic imaging , Cathartics/administration & dosage , Water/administration & dosage , Vagina/diagnostic imaging , Sensitivity and Specificity
7.
BMC Cardiovasc Disord ; 24(1): 254, 2024 May 16.
Article En | MEDLINE | ID: mdl-38750460

INTRODUCTION: The aim of this study is to analyze the diagnostic value of global longitudinal strain (GLS) in detecting inducible myocardial ischemia in patients with chest pain undergoing treadmill contrast-enhanced stress echocardiography (SE). METHODS: We retrospectively enrolled all patients who underwent invasive coronary angiography after treadmill contrast-enhanced SE. Rest and peak-stress myocardial GLS, segmental LS, and LS of 4-chamber (CH), 2-CH, and 3-CH views were reported. Luminal stenosis of more than 70% or fractional flow reserve (FFR) of < 0.8 was considered significant. RESULTS: In total 33 patients were included in the final analysis, among whom sixteen patients (48.4%) had significant coronary artery stenosis. Averaged GLS, 3-CH, and 4-CH LS were significantly lower in patients with critical coronary artery stenosis compared to those without significant stenosis (-17.1 ± 7.1 vs. -24.2 ± 7.2, p = 0.041), (-18.2 ± 8.9 vs. -24.6 ± 8.2, p = 0.045) and (-14.8 ± 6.2 vs. -22.8 ± 7.8, p = 0.009), respectively. Receiver operating characteristic (ROC) analysis of ischemic and non-ischemic segments demonstrated that a cut-off value of -20% of stress LS had 71% sensitivity and 60% specificity for ruling out inducible myocardial ischemia (Area under the curve was AUC = 0.72, P < 0.0001). CONCLUSION: Myocardial LS measured with treadmill contrast-enhanced stress echocardiography demonstrates potential value in identifying patients with inducible myocardial ischemia.


Contrast Media , Coronary Angiography , Coronary Stenosis , Echocardiography, Stress , Predictive Value of Tests , Humans , Male , Female , Echocardiography, Stress/methods , Retrospective Studies , Middle Aged , Aged , Contrast Media/administration & dosage , Coronary Stenosis/physiopathology , Coronary Stenosis/diagnostic imaging , Reproducibility of Results , Myocardial Contraction , Ventricular Function, Left , Myocardial Ischemia/physiopathology , Myocardial Ischemia/diagnostic imaging , Fractional Flow Reserve, Myocardial
8.
Int J Pharm ; 658: 124203, 2024 Jun 10.
Article En | MEDLINE | ID: mdl-38705249

Most nanomedicines with suitable sizes (normally 100-200 nm) exhibit favorable accumulation in the periphery of tumors but hardly penetrate into deep tumors. Effective penetration of nanomedicines requires smaller sizes (less than 30 nm) to overcome the elevated tumor interstitial fluid pressure. Moreover, integrating an efficient diagnostic agent in the nanomedicines is in high demand for precision theranostics of tumors. To this end, a near-infrared light (NIR) -triggered size-shrinkable micelle system (Fe3O4@AuNFs/DOX-M) coloaded antitumor drug doxorubicin (DOX) and biomodal imaging agent magnetic gold nanoflower (Fe3O4@AuNFs) was developed to achieve efficient theranostic of tumors. Upon the accumulation of Fe3O4@AuNFs/DOX-M in the tumor periphery, a NIR laser was irradiated near the tumor sites, and the loaded Fe3O4@Au NFs could convert the light energy to heat, which triggered the cleavage of DOX-M to the ultra-small micelles (∼5 nm), thus realizing the deep penetration of micelles and on-demand drug release. Moreover, Fe3O4@AuNFs in the micelles could also be used as CT/MRI dual-modal contrast agent to "visualize" the tumor. Up to 92.6 % of tumor inhibition was achieved for the developed Fe3O4@AuNFs/DOX-M under NIR irradiation. This versatile micelle system provided a promising drug carrier platform realizing efficient tumor dual-modal diagnosis and photothermal-chemotherapy integration.


Doxorubicin , Gold , Infrared Rays , Micelles , Theranostic Nanomedicine , Doxorubicin/administration & dosage , Doxorubicin/chemistry , Animals , Gold/chemistry , Gold/administration & dosage , Theranostic Nanomedicine/methods , Humans , Cell Line, Tumor , Neoplasms/drug therapy , Neoplasms/diagnostic imaging , Drug Liberation , Mice , Antibiotics, Antineoplastic/administration & dosage , Magnetic Resonance Imaging/methods , Mice, Inbred BALB C , Drug Delivery Systems/methods , Contrast Media/chemistry , Contrast Media/administration & dosage , Drug Carriers/chemistry , Particle Size , Female , Mice, Nude
9.
Sci Rep ; 14(1): 9665, 2024 04 26.
Article En | MEDLINE | ID: mdl-38671061

This study clinically implemented a ready-to-use quantitative perfusion (QP) cardiovascular magnetic resonance (QP CMR) workflow, encompassing a simplified dual-bolus gadolinium-based contrast agent (GBCA) administration scheme and fully automated QP image post-processing. Twenty-five patients with suspected obstructive coronary artery disease (CAD) underwent both adenosine stress perfusion CMR and an invasive coronary angiography or coronary computed tomography angiography. The dual-bolus protocol consisted of a pre-bolus (0.0075 mmol/kg GBCA at 0.5 mmol/ml concentration + 20 ml saline) and a main bolus (0.075 mmol/kg GBCA at 0.5 mmol/ml concentration + 20 ml saline) at an infusion rate of 3 ml/s. The arterial input function curves showed excellent quality. Stress MBF ≤ 1.84 ml/g/min accurately detected obstructive CAD (area under the curve 0.79; 95% Confidence Interval: 0.66 to 0.89). Combined visual assessment of color pixel QP maps and conventional perfusion images yielded a diagnostic accuracy of 84%, sensitivity of 70% and specificity of 93%. The proposed easy-to-use dual-bolus QP CMR workflow provides good image quality and holds promise for high accuracy in diagnosis of obstructive CAD. Implementation of this approach has the potential to serve as an alternative to current methods thus increasing the accessibility to offer high-quality QP CMR imaging by a wide range of CMR laboratories.


Contrast Media , Coronary Artery Disease , Workflow , Humans , Contrast Media/administration & dosage , Female , Male , Middle Aged , Aged , Coronary Artery Disease/diagnostic imaging , Magnetic Resonance Imaging/methods , Coronary Angiography/methods , Myocardial Perfusion Imaging/methods , Gadolinium/administration & dosage
10.
BMC Cardiovasc Disord ; 24(1): 230, 2024 Apr 27.
Article En | MEDLINE | ID: mdl-38678215

BACKGROUND: Unidentified heart failure occurs in patients with multiple myeloma when their heart was involved. CMR with late gadolinium enhancement (LGE) and T1 mapping can identify myocardial amyloid infiltrations. PURPOSE: To explore the role of CMR with late gadolinium enhancement (LGE) and T1 mapping for detection of multiple myeloma patients'heart. MATERIAL AND METHODS: A total of 16 MM patients with above underwent CMR (3.0-T) with T1 mapping (pre-contrast and post-contrast) and LGE imaging. In addition, 26 patients with non-obstructive hypertrophic cardiomyopathy and 26 healthy volunteers were compared to age- and sex-matched healthy controls without a history of cardiac disease, diabetes mellitus, or normal in CMR. All statistical analyses were performed using the statistical software GraphPad Prism. The measurement data were represented by median (X) and single sample T test was adopted. Enumeration data were represented by examples and Chi-tested was adopted. All tests were two-sided, and P values < 0.05 were considered statistically significant. RESULTS: In MM group, LVEF was lower than healthy controls and higher than that of non-obstructive hypertrophic cardiomyopathy group, but without statistically significant difference (%: 49.1 ± 17.5 vs. 55.6 ± 10.3, 40.4 ± 15.6, all P > 0.05). Pre-contrast T1 values of MM group were obviously higher than those of healthy controls and non-obstructive hypertrophic cardiomyopathy group (ms:1462.0 ± 71.3vs. 1269.3 ± 42.3, 1324.0 ± 45.1, all P < 0.05). 16 cases (100%) in MM group all had LGE. CONCLUSION: LGE joint T1 mapping wider clinical use techniques and follow-up the patients'disease severity.


Cardiomyopathy, Hypertrophic , Contrast Media , Magnetic Resonance Imaging, Cine , Multiple Myeloma , Predictive Value of Tests , Stroke Volume , Ventricular Function, Left , Humans , Multiple Myeloma/diagnostic imaging , Multiple Myeloma/diagnosis , Male , Female , Middle Aged , Contrast Media/administration & dosage , Aged , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/physiopathology , Case-Control Studies , Myocardium/pathology , Adult , Heart Failure/diagnostic imaging , Heart Failure/physiopathology , Heart Failure/diagnosis , Heart Failure/etiology
11.
Eur Radiol Exp ; 8(1): 53, 2024 May 01.
Article En | MEDLINE | ID: mdl-38689178

BACKGROUND: To compare denoising diffusion probabilistic models (DDPM) and generative adversarial networks (GAN) for recovering contrast-enhanced breast magnetic resonance imaging (MRI) subtraction images from virtual low-dose subtraction images. METHODS: Retrospective, ethically approved study. DDPM- and GAN-reconstructed single-slice subtraction images of 50 breasts with enhancing lesions were compared to original ones at three dose levels (25%, 10%, 5%) using quantitative measures and radiologic evaluations. Two radiologists stated their preference based on the reconstruction quality and scored the lesion conspicuity as compared to the original, blinded to the model. Fifty lesion-free maximum intensity projections were evaluated for the presence of false-positives. Results were compared between models and dose levels, using generalized linear mixed models. RESULTS: At 5% dose, both radiologists preferred the GAN-generated images, whereas at 25% dose, both radiologists preferred the DDPM-generated images. Median lesion conspicuity scores did not differ between GAN and DDPM at 25% dose (5 versus 5, p = 1.000) and 10% dose (4 versus 4, p = 1.000). At 5% dose, both readers assigned higher conspicuity to the GAN than to the DDPM (3 versus 2, p = 0.007). In the lesion-free examinations, DDPM and GAN showed no differences in the false-positive rate at 5% (15% versus 22%), 10% (10% versus 6%), and 25% (6% versus 4%) (p = 1.000). CONCLUSIONS: Both GAN and DDPM yielded promising results in low-dose image reconstruction. However, neither of them showed superior results over the other model for all dose levels and evaluation metrics. Further development is needed to counteract false-positives. RELEVANCE STATEMENT: For MRI-based breast cancer screening, reducing the contrast agent dose is desirable. Diffusion probabilistic models and generative adversarial networks were capable of retrospectively enhancing the signal of low-dose images. Hence, they may supplement imaging with reduced doses in the future. KEY POINTS: • Deep learning may help recover signal in low-dose contrast-enhanced breast MRI. • Two models (DDPM and GAN) were trained at different dose levels. • Radiologists preferred DDPM at 25%, and GAN images at 5% dose. • Lesion conspicuity between DDPM and GAN was similar, except at 5% dose. • GAN and DDPM yield promising results in low-dose image reconstruction.


Breast Neoplasms , Contrast Media , Magnetic Resonance Imaging , Humans , Female , Retrospective Studies , Contrast Media/administration & dosage , Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Middle Aged , Models, Statistical , Adult , Aged
12.
Anticancer Res ; 44(5): 2021-2030, 2024 May.
Article En | MEDLINE | ID: mdl-38677765

BACKGROUND/AIM: In the context of surgical de-escalation in early breast cancer (EBC), this study aimed to evaluate the contrast enhancement ultrasound (CEUS) sentinel lymph node (SLN) procedure as a non-invasive axillary staging procedure in EBC in comparison with standard SLN biopsy (SLNB). PATIENTS AND METHODS: A subanalysis of the AX-CES study, a prospective single-arm, monocentric phase 3 study was performed (EudraCT: 2020-000393-20). The study included patients with EBC undergoing upfront surgery and SLN resection, with no prior history of locoregional treatment, and weighing between 40-85 kg. All patients underwent the CEUS SLN procedure as a non-invasive axillary staging procedure, with CEUS SLN accumulation marked using blue dye. After the CEUS SLN procedure, all patients underwent the standard mapping procedure. Data on success rate, systemic reactions, mean procedure time, mean surgical procedure, mean procedure without axillary staging, CEUS SLN appearance (normal/pathological), SLN number, and concordance with standard mapping procedure were collected. RESULTS: After the CEUS SLN procedure, 29 LNs among 16 patients were identified and marked. In all cases, CEUS SLN revealed at least one LN enhancement. Six (37.50%) LNs were defined as pathological after the CEUS SLN procedure. Definitive staining of CEUS SLN pathology revealed metastatic involvement in four (66.67%) of the cases. Two SLNs were identified during the CEUS SLN procedure; however, owing to the low disease burden, no change in the surgical plan was reported. CONCLUSION: The CEUS SLN procedure shows promise as a technique for non-invasive assessment of the axilla, potentially enabling safe axillary de-escalation in EBC by estimating the axillary disease burden.


Axilla , Breast Neoplasms , Contrast Media , Neoplasm Staging , Sentinel Lymph Node Biopsy , Sulfur Hexafluoride , Humans , Breast Neoplasms/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Female , Contrast Media/administration & dosage , Middle Aged , Aged , Prospective Studies , Sentinel Lymph Node Biopsy/methods , Sulfur Hexafluoride/administration & dosage , Ultrasonography/methods , Microbubbles , Lymphatic Metastasis/diagnostic imaging , Sentinel Lymph Node/pathology , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/surgery , Adult
14.
Vasa ; 53(3): 193-203, 2024 May.
Article En | MEDLINE | ID: mdl-38651340

Endovascular interventions and diagnostic examinations using iodinated contrast media (ICM) are standard of care in current vascular medicine. Although ICM use is generally considered safe, it may be associated with adverse reactions, vary from minor disturbances to rare, but severe life-threatening complications. This position paper of European Society of Vascular Medicine integrates current knowledge and summarizes the key information related to the use of intravascular ICM, serving as recommendation on prevention and management of acute, late, and very late adverse reactions. It should help the health professionals in all fields of vascular medicine to make decisions in daily practice for safe use of contrast media.


Contrast Media , Endovascular Procedures , Humans , Consensus , Contrast Media/adverse effects , Contrast Media/administration & dosage , Endovascular Procedures/adverse effects , Iodine Compounds/adverse effects , Radiography, Interventional/adverse effects , Risk Assessment , Risk Factors , Treatment Outcome
15.
Rinsho Shinkeigaku ; 64(5): 339-343, 2024 May 24.
Article Ja | MEDLINE | ID: mdl-38658329

A 70-year-old female presented with bilateral numbness in her upper limbs. She was diagnosed with cervical spondylotic myelopathy and underwent cervical laminoplasty. However, there was no significant improvement in sensory disturbance, and at 6 months after surgery, she developed subacute motor and gait disturbance in four extremities. Spinal MRI revealed a long lesion of the spinal cord with edema, and a part of the lesion showed gadolinium contrast enhancement. Bronchoscopy revealed an elevated CD4/8 ratio, and gallium scintigraphy demonstrated an accumulation in the hilar lymph nodes, leading to a diagnosis of neurosarcoidosis. In case of rapid deterioration during the course of cervical spondylotic myelopathy, neurosarcoidosis should be considered as a differential diagnosis, which can be assessed by contrast-enhanced MRI.


Central Nervous System Diseases , Cervical Vertebrae , Contrast Media , Gadolinium , Magnetic Resonance Imaging , Sarcoidosis , Humans , Female , Sarcoidosis/diagnostic imaging , Aged , Contrast Media/administration & dosage , Diagnosis, Differential , Central Nervous System Diseases/diagnostic imaging , Central Nervous System Diseases/diagnosis , Gadolinium/administration & dosage , Cervical Vertebrae/diagnostic imaging , Spondylosis/diagnostic imaging , Spondylosis/surgery , Spinal Cord Diseases/diagnostic imaging , Spinal Cord Diseases/etiology
16.
Minerva Med ; 115(2): 151-161, 2024 Apr.
Article En | MEDLINE | ID: mdl-38563606

BACKGROUND: Contrast media used in mechanical therapies for stroke and myocardial infarction represent a significant cause of acute kidney injury (AKI) in acute medical scenarios. Although the continuous saline infusion line (CSIL) is a standard procedure to prevent thrombus formation within the catheter during neurovascular interventions of mechanical thrombectomy (MT), it is not utilized in percutaneous coronary interventions (PCI). METHODS: A systematic review of the incidence of AKI after MT for stroke treatment was performed. These data were compared with those reported in the literature regarding the incidence of AKI after PCI for acute myocardial infarction. A random-effect model meta-regression was performed to explore the effects of CSIL on AKI incidence, using clinical details as covariates. RESULTS: A total of 18 and 33 studies on MT and PCI were included, respectively, with 69,464 patients (30,138 [43.4%] for MT and 39,326 [56.6%] for PCI). The mean age was 63.6 years±5.8 with male 66.6%±12.8. Chronic kidney disease ranged 2.0-50.3%. Diabetes prevalence spanned 11.1% to 53.0%. Smoking status had a prevalence of 7.5-72.0%. Incidence of AKI proved highly variable (I2=98%, Cochrane's Q 2985), and appeared significantly lower in the MT subgroup than in the PCI subgroups (respectively 8.3% [95% confidence interval: 4.7-11.9%] vs. 14.7 [12.6-16.8%], P<0.05). Meta-regression showed that CSIL was significantly associated with a decreased incidence of AKI (OR=0.93 [1.001-1.16]; P=0.03). CONCLUSIONS: Implementation of CSIL during endovascular procedures in acute settings was associated with a significant decrease in the risk of AKI, and its safety should be routinely considered in such interventions.


Acute Kidney Injury , Endovascular Procedures , Myocardial Infarction , Percutaneous Coronary Intervention , Stroke , Humans , Male , Acute Kidney Injury/prevention & control , Acute Kidney Injury/etiology , Acute Kidney Injury/epidemiology , Contrast Media/adverse effects , Contrast Media/administration & dosage , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Incidence , Myocardial Infarction/prevention & control , Myocardial Infarction/epidemiology , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Saline Solution/administration & dosage , Stroke/prevention & control , Stroke/epidemiology , Stroke/etiology , Thrombectomy/adverse effects , Thrombectomy/methods , Female , Middle Aged , Aged
17.
JNCI Cancer Spectr ; 8(3)2024 Apr 30.
Article En | MEDLINE | ID: mdl-38565262

Women with high mammographic density have an increased risk of breast cancer. They may be offered contrast-enhanced mammography to improve breast cancer screening performance. Using a cohort of women receiving contrast-enhanced mammography, we evaluated whether conventional and modified mammographic density measures were associated with breast cancer. Sixty-six patients with newly diagnosed unilateral breast cancer were frequency matched on the basis of age to 133 cancer-free control individuals. On low-energy craniocaudal contrast-enhanced mammograms (equivalent to standard mammograms), we measured quantitative mammographic density using CUMULUS software at the conventional intensity threshold ("Cumulus") and higher-than-conventional thresholds ("Altocumulus," "Cirrocumulus"). The measures were standardized to enable estimation of odds ratio per adjusted standard deviation (OPERA). In multivariable logistic regression of case-control status, only the highest-intensity measure (Cirrocumulus) was statistically significantly associated with breast cancer (OPERA = 1.40, 95% confidence interval = 1.04 to 1.89). Conventional Cumulus did not contribute to model fit. For women receiving contrast-enhanced mammography, Cirrocumulus mammographic density may better predict breast cancer than conventional quantitative mammographic density.


Breast Neoplasms , Contrast Media , Mammography , Humans , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Middle Aged , Contrast Media/administration & dosage , Case-Control Studies , Aged , Breast Density , Logistic Models , Adult , Odds Ratio , Breast/diagnostic imaging , Breast/pathology
18.
J Stroke Cerebrovasc Dis ; 33(6): 107673, 2024 Jun.
Article En | MEDLINE | ID: mdl-38458504

BACKGROUND: Blood brain barrier disruption (BBBD) can be visualized by contrast extravasation (CE) after endovascular treatment (EVT) in patients with acute ischemic stroke. Elevated blood pressure is a risk factor for BBBD. However, the association between procedural blood pressure and CE post-EVT is unknown. METHODS: In this single-center retrospective study, we analyzed 501 eligible patients who received a dual energy CT (DECT) immediately post-EVT for acute ischemic stroke. Procedural blood pressure values (SBPmean, SBPmax, SBPmax-min, and MAPmean) were collected. CE was quantified by measuring the maximum parenchymal iodine concentration on DECT iodine overlay map reconstructions. As a measure for the extent of BBBD, we created CE-ASPECTS by deducting one point per hyperdense ASPECTS region on iodine overlay maps. The association between blood pressure and CE was assessed using multivariable linear regression. RESULTS: The procedural SBPmean, SBPmax, and MAPmean were 150 ± 26 mmHg, 173 ± 29 mmHg, and 101 ± 17 mmHg, respectively. The median maximum iodine concentration on post-EVT DECT was 1.2 mg/ml (IQR 0.7-2.0), and median CE-ASPECTS was 8 (IQR 5-11). The maximum iodine concentration was not associated with blood pressure. SBPmean, SBPmax, and MAPmean were significantly associated with CE-ASPECTS (per 10 mmHg, ß = -0.2, 95 % CI -0.31 to -0.09, ß = -0.15, 95 % CI -0.25 to -0.06, ß = -0.33, 95 % CI -0.49 to -0.17, respectively). CONCLUSION: In acute ischemic stroke patients undergoing EVT, particularly in patients achieving successful recanalization, SBPmean, SBPmax, and MAPmean are associated with the extent of BBBD on immediate post-EVT DECT, but not with maximum iodine concentration.


Blood Pressure , Contrast Media , Endovascular Procedures , Extravasation of Diagnostic and Therapeutic Materials , Ischemic Stroke , Predictive Value of Tests , Humans , Female , Male , Retrospective Studies , Aged , Endovascular Procedures/adverse effects , Extravasation of Diagnostic and Therapeutic Materials/diagnostic imaging , Contrast Media/administration & dosage , Contrast Media/adverse effects , Risk Factors , Ischemic Stroke/physiopathology , Ischemic Stroke/therapy , Ischemic Stroke/diagnostic imaging , Treatment Outcome , Middle Aged , Aged, 80 and over , Computed Tomography Angiography , Tomography, X-Ray Computed
19.
Am J Vet Res ; 85(5)2024 May 01.
Article En | MEDLINE | ID: mdl-38457913

OBJECTIVE: This study evaluated the effects of scanning position and contrast medium injection rate on pulmonary CT perfusion (CTP) images in healthy dogs. ANIMALS: 7 healthy Beagles. METHODS: Experiments involved 4 conditions: dorsal and sternal recumbency at 2.5 mL/s (first) and sternal recumbency with additional rates of 1.5 and 3.5 mL/s (second). Various parameters, including the initial time of venous enhancement (Tv), peak time of arterial enhancement (PTa), and peak enhancement values of the artery, were measured. The PTa to Tv interval was calculated. Perfusion mapping parameters (pulmonary blood flow, pulmonary blood volume, mean transit time, time to maximum, and time to peak) were determined in different lung regions (left and right dorsal, middle, and ventral). RESULTS: There are significant variations in most perfusion mapping parameters based on the pulmonary parenchymal location. Dorsal recumbency had a lower peak value of arterial enhancement than sternal recumbency. Pulmonary blood flow in the dorsal region and mean transit time and time to maximum in all regions showed no significant differences based on position. Pulmonary blood volume and time to peak varied with scanning position. The PTa to Tv interval did not differ based on the injection rate, but the injection time at 1.5 mL/s was longer than at other rates. All perfusion mapping parameters of the ventral region increased with higher injection rates. CLINICAL RELEVANCE: The recommended CTP imaging approach in dogs is a low injection rate of 1.5 mL/s in the sternal recumbency. This study provides reference ranges for perfusion parameters based on the pulmonary parenchymal location, contributing to the acquisition and application of pulmonary CTP images for differential diagnosis in small-breed dogs.


Contrast Media , Lung , Tomography, X-Ray Computed , Animals , Dogs , Tomography, X-Ray Computed/veterinary , Lung/diagnostic imaging , Lung/blood supply , Contrast Media/administration & dosage , Male , Female , Pulmonary Circulation/physiology
20.
Pediatr Radiol ; 54(5): 820-830, 2024 May.
Article En | MEDLINE | ID: mdl-38506945

BACKGROUND: The off-label use of contrast-enhanced ultrasound has been increasingly used for pediatric patients. OBJECTIVE: The purpose of this retrospective study is to report any observed clinical changes associated with the intravenous (IV) administration of ultrasound contrast to critically ill neonates, infants, children, and adolescents. MATERIALS AND METHODS: All critically ill patients who had 1 or more contrast-enhanced ultrasound scans while being closely monitored in the neonatal, pediatric, or pediatric cardiac intensive care units were identified. Subjective and objective data concerning cardiopulmonary, neurological, and hemodynamic monitoring were extracted from the patient's electronic medical records. Vital signs and laboratory values before, during, and after administration of ultrasound contrast were obtained. Statistical analyses were performed using JMP Pro, version 15. Results were accepted as statistically significant for P-value<0.05. RESULTS: Forty-seven contrast-enhanced ultrasound scans were performed on 38 critically ill patients, 2 days to 17 years old, 19 of which were female (50%), and 19 had history of prematurity (50%). At the time of the contrast-enhanced ultrasound scans, 15 patients had cardiac shunts or a patent ductus arteriosus, 25 had respiratory failure requiring invasive mechanical oxygenation and ventilation, 19 were hemodynamically unstable requiring continual vasoactive infusions, and 8 were receiving inhaled nitric oxide. In all cases, no significant respiratory, neurologic, cardiac, perfusion, or vital sign changes associated with IV ultrasound contrast were identified. CONCLUSION: This study did not retrospectively identify any adverse clinical effects associated with the IV administration of ultrasound contrast to critically ill neonates, infants, children, and adolescents.


Contrast Media , Critical Illness , Humans , Infant , Female , Child , Male , Adolescent , Child, Preschool , Infant, Newborn , Retrospective Studies , Contrast Media/administration & dosage , Administration, Intravenous , Ultrasonography/methods
...