Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.233
Filter
1.
BMC Ophthalmol ; 24(1): 325, 2024 Aug 05.
Article in English | MEDLINE | ID: mdl-39103855

ABSTRACT

BACKGROUND: To analyze the clinical outcomes after topography-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) with Phorcides Analytic Engine (PAE) algorithm or Custom-Q FS-LASIK for myopia with nonastigmatic eyes. METHODS: In this retrospective study, a total of 90 eyes with myopia without manifest astigmatism (82 patients) were included. All surgeries were performed by topography-guided FS-LASIK planned with a PAE algorithm (42 eyes) or Custom-Q system (48 eyes). Refractive, visual outcomes and corneal aberrations were compared between the two groups. RESULTS: At 6 months postoperatively, the postoperative uncorrected distance visual acuity (UDVA) was 20/20 or better in 42 eyes (100%) in the PAE compared with 44 eyes (92%) in Custom-Q (P = .120). The postoperative UDVA of 20/16 or better was measured in 92% of eyes in the PAE group and 81% of eyes in the Custom Q group (P = .320). Postoperative corrected distance visual acuity, manifest refractive spherical equivalent and refractive astigmatism were similar between the two groups (P > .05). The postoperative optical path difference (OPD) and Strehl ratio (SR) were significantly better in the PAE group compared with the Custom Q group. CONCLUSIONS: Topography-guided FS-LASIK with PAE algorithm or Custom Q demonstrated similar refractive efficacy and predictability. PAE for the patients with zero manifest astigmatism demonstrated better results in correcting corneal aberrations.


Subject(s)
Corneal Topography , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Refraction, Ocular , Visual Acuity , Humans , Keratomileusis, Laser In Situ/methods , Retrospective Studies , Visual Acuity/physiology , Male , Female , Myopia/surgery , Myopia/physiopathology , Adult , Refraction, Ocular/physiology , Lasers, Excimer/therapeutic use , Young Adult , Treatment Outcome , Surgery, Computer-Assisted/methods
2.
BMC Ophthalmol ; 24(1): 328, 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39107739

ABSTRACT

BACKGROUND: Visual impairment can cause balance problems. Therefore, visual impairment caused by an increase in corneal deviations can lead to sudden and unstable loads in the lower extremities. We aimed to investigate the possible relationship between low-energy meniscal injuries and corneal structural measures. METHODS: This prospective, observational study included individuals aged between 18-40 years with a normal body-mass index. The study group consisted of 54 patients with grade 2 or 3 meniscus injuries after low-energy activity. The control group consisted of 54 healthy individuals without any complaints in the knee joint. The corneal parameters of all participants were evaluated with a Scheimpflug corneal topography and specular microscopy device. Simulated keratometry (SimK), minimum central corneal thickness (MCCT), cylindrical diopter (ClyD), corneal volume (CVol) spheric aberrations (SphAbb), high-order aberration (HOA), coma values, and endothelial parameters were recorded. RESULTS: The research and control groups were similar in terms of age, body mass index, and gender distribution. There was no significant difference between the groups in the corneal SimK and CylD, parameters. However, HOA, Coma, SphAbb, and cell variability (Cv) values were significantly higher in the study group, and contrarily MCCT, CVol, and endothelial count (Cd) values were significantly lower. CONCLUSIONS: Our findings suggest that individuals with relatively lower MCCT values tend to develop meniscal damage after low-energy activity. Hence, the loss of corneal strength in these patients may be a sign of possible weakness in the meniscus. The HOA value above 0.26, the coma value above 0.16, and the SphAbb value above 0.1 may significantly increase the possible meniscus injury.


Subject(s)
Corneal Topography , Humans , Male , Female , Prospective Studies , Adult , Young Adult , Adolescent , Tibial Meniscus Injuries/physiopathology , Cornea/pathology , Cornea/physiopathology , Corneal Wavefront Aberration/physiopathology , Visual Acuity/physiology
3.
J Refract Surg ; 40(8): e554-e561, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39120015

ABSTRACT

PURPOSE: To explore the use of autologous astigmatic lenticule reshaping and rotation surgery to correct high astigmatism in conjunction with excimer laser technology to correct residual refractive error. METHODS: Six patients with high astigmatism (8 eyes, all with astigmatism from -5.50 to -11.00 diopters [D]) seeking refractive error correction were enrolled. The following methods were used to correct refractive errors that could not be corrected by a single conventional surgery: (1) cutting of a customized lens using FLEx technology, (2) lifting of the corneal flap and reshaping the autologous astigmatic lenticule in situ using an excimer laser, and (3) rotation of the autologous astigmatic lenticule by 90°. Uncorrected distance visual acuity, subjective refraction, corneal topography, and anterior segment optical coherence tomography were performed preoperatively and postoperatively. RESULTS: The efficacy and safety indices at 6 months postoperatively were 0.93 ± 0.18 and 1.06 ± 0.11, respectively, the spherical equivalent remained stable and close to emmetropia (-0.13 ± 0.70 D) from 1 to 6 months postoperatively, postoperative astigmatism was generally mildly undercorrected (-1.22 ± 0.43 D), and the difference in corneal curvatures at 2 mm from the apex of the cornea was significantly reduced compared to preoperatively (P < .05); however, the corresponding values at 1 and 3 mm showed no difference. CONCLUSIONS: Correction of high astigmatism with autologous astigmatic lenticule reshaping and rotation surgery is tissue-sparing, predictable, and significantly improves postoperative visual acuity and quality. This method is feasible and safe, with predictability requiring further study. This novel surgical approach has potential for patients with high astigmatism that cannot be corrected by conventional refractive surgery. [J Refract Surg. 2024;40(8):e554-e561.].


Subject(s)
Astigmatism , Corneal Stroma , Corneal Topography , Lasers, Excimer , Refraction, Ocular , Surgical Flaps , Tomography, Optical Coherence , Visual Acuity , Humans , Astigmatism/physiopathology , Astigmatism/surgery , Visual Acuity/physiology , Refraction, Ocular/physiology , Lasers, Excimer/therapeutic use , Male , Corneal Stroma/surgery , Adult , Female , Young Adult , Rotation , Middle Aged , Keratomileusis, Laser In Situ/methods
4.
J Refract Surg ; 40(8): e569-e578, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39120013

ABSTRACT

PURPOSE: To assess the corneal biomechanical properties in normal individuals and patients with keratoconus using the Brillouin optical scanning system (Intelon Optics) (BOSS) and compare them with ultra-high-speed Scheimpflug imaging (Corvis ST; Oculus Optikgeräte GmbH). METHODS: Sixty eyes from 60 patients (30 normal and 30 keratoconus) were included in this prospective, single-center, comparative, non-interventional study. Corneal biomechanics were evaluated using the Corvis ST and the BOSS. With the BOSS, each corneal image was acquired three times, measuring 10 locations within an 8-mm diameter. Parameters extracted included mean, maximum, and minimum Brillouin shift. These 10 points were also grouped into superior, central, and inferior regions. BOSS repeatability was assessed using the coefficient of repeatability and coefficient of variation. Furthermore, normal individuals and patients with keratoconus were compared using the Corvis ST and BOSS. RESULTS: The BOSS exhibited good repeatability, with coefficient of repeatability ranging from 0.098 to 0.138 GHz for single points in normal individuals and 0.096 to 0.149 GHz for patients with keratoconus. Statistical analysis revealed significant differences between normal individuals and patients with keratoconus, indicating softer corneas in keratoconus, observed with both the Corvis ST and BOSS. Specifically, the BOSS showed significant differences in mean, inferior, and superior mean, maximum, and minimum Brillouin frequency shift (all P < .05), whereas the Corvis ST displayed highly significant differences in stiffness parameter at first applanation, stress strain index, deformation amplitude ratio, and inverse integrated radius (all P < .001). CONCLUSIONS: Corneal biomechanical measurements proved highly repeatable and effectively demonstrated significant differences between normal individuals and patients with keratoconus using both the BOSS and the Corvis ST. [J Refract Surg. 2024;40(8):e569-e578.].


Subject(s)
Cornea , Corneal Topography , Elasticity , Keratoconus , Humans , Prospective Studies , Keratoconus/physiopathology , Keratoconus/diagnosis , Cornea/physiopathology , Cornea/diagnostic imaging , Male , Biomechanical Phenomena , Adult , Female , Young Adult , Elasticity/physiology , Reproducibility of Results , Microscopy , Middle Aged , Adolescent
5.
Invest Ophthalmol Vis Sci ; 65(10): 9, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39102261

ABSTRACT

Purpose: The purpose of this study was to explore the optimal shape of customized lenticules for stromal lenticule addition keratoplasty (SLAK) for off-centered ectasia. Methods: Two different methods to create ex vivo models of eccentric-keratoconus were investigated. Twelve human corneas were used to create model 1 by a hyperopic photorefractive keratectomy (PRK), and model 2 by masked phototherapeutic keratectomy (PTK) on the anterior corneal surface, whereas both types received myopic ablation of the posterior surface. Keratoconus models underwent a modified femtosecond laser (FSL) flap-cut to create stromal pockets. Sixteen human corneas underwent FSL dissection to obtain four lenticule types: type I (planar) and type II (negative) lenticules were used without modifications, whereas type III (customized-planar), and type IV (customized-negative) lenticules underwent further masked-PRK to obtain an asymmetric bow-tie shape. Topographic, aberrometric analysis, and anterior segment optical coherence tomography (AS-OCT) were performed in all recipient corneas before and after lenticule implantation. Results: Keratoconus model was successfully reproduced. Tomographic analysis showed a significant inferiorly decentered corneal steepening with coherent stromal thinning. Model 2 reproduced better the curvature of real keratoconus. Lenticules type I implantation induced a homogeneous corneal thickening, type III produced higher thickening in the inferior half of the cornea. Type II determined a maximal peripheral pachymetric increase, with a gradual reduction toward the center, and type IV presented an asymmetric peripheral thickening. Topographic assessment showed a cone apex flattening in all cases, but it was significantly higher in types II and IV. Customized lenticules improved significantly corneal surface regularity regarding types I and II. Conclusions: The approach of customizing lenticules by increasing their asymmetry and tailoring the re-shaping effects, may improve SLAK outcomes in eccentric keratoconus.


Subject(s)
Corneal Stroma , Corneal Topography , Keratoconus , Photorefractive Keratectomy , Tomography, Optical Coherence , Humans , Corneal Stroma/surgery , Corneal Stroma/transplantation , Keratoconus/surgery , Keratoconus/physiopathology , Photorefractive Keratectomy/methods , Lasers, Excimer/therapeutic use , Female , Male , Adult , Surgical Flaps , Aberrometry , Refraction, Ocular/physiology , Corneal Transplantation/methods , Middle Aged
6.
PLoS One ; 19(8): e0308204, 2024.
Article in English | MEDLINE | ID: mdl-39116076

ABSTRACT

PURPOSE: Mitigating unwanted refractive errors is crucial for surgeons to ensure quality vision after penetrating keratoplasty (PK). The primary objective of the present study is to highlight the importance of microstructural matching of the host and the donor cornea during PK on the distribution of the corneal tissue while suturing. METHODS: For this purpose, the present study undertakes an in-vitro PK model to analyse the effect of suturing and host-donor misalignment on corneal birefringence. Five groups of experiments were performed using five corneoscleral buttons. In each group, N = 16 data points (corresponding to 16 simple interrupted sutures) were assessed before and after PK with five degrees of misalignments, 0°, 30°, 45°, 60° and 90° to detect the variations in corneal birefringence post-PK. The technique of digital photoelasticity is utilized to capture the corneal birefringence experimentally. RESULTS: The local and global features of corneal birefringence provided interesting insights into the nuances of corneal birefringence in PK. Statistical analysis was performed to study the effects of suturing on the birefringence around the suture bites. It was observed that the interaction of the suture tension and structural misalignment between the host and the donor cornea influences the corneal birefringence in PK. Conclusions The zero-degree structural misalignment of the host and the donor tissue is preferable to minimize the topographical irregularities and related astigmatism post-PK. The findings of the present study envisage an additional step of structurally aligning the donor tissue with the host before suturing to minimize topographical irregularities in PK.


Subject(s)
Collagen , Cornea , Keratoplasty, Penetrating , Tissue Donors , Keratoplasty, Penetrating/methods , Cornea/surgery , Collagen/chemistry , Sutures/adverse effects , Birefringence , Humans , Suture Techniques , Corneal Topography/methods
7.
Arq Bras Oftalmol ; 87(5): e20230009, 2024.
Article in English | MEDLINE | ID: mdl-39109702

ABSTRACT

This document on myopia control is derived from a compilation of medical literature and the collective clinical expertise of an expert committee comprising members from the Brazilian Society of Pediatric Ophthalmology and the Brazilian Society of Contact Lenses and Cornea. To manage myopia in children, the committee recommends corneal topography and biannual visits with cycloplegic refraction, along with annual optical biometry. For fast-progressing myopia, biannual biometry should be considered. Myopic progression is defined as an annual increase in spherical equivalent greater than 0.50 D/year or in axial length greater than 0.3 mm (until 10 years old) or 0.2 mm (above 11 years). The proposed treatments for myopia progression include environmental control, low concentration atropine, defocus glasses, contact lenses, or Ortho-K lenses, and combinations of these methods may be necessary for uncontrolled cases. Treatment should be sustained for at least 2 years. This document serves as a comprehensive guideline for diagnosing, treating, and monitoring pre-myopic and myopic children in Brazil.


Subject(s)
Disease Progression , Myopia , Humans , Child , Myopia/prevention & control , Myopia/therapy , Brazil , Refraction, Ocular/physiology , Corneal Topography/methods , Biometry/methods
8.
Arq Bras Oftalmol ; 88(1): e20230056, 2024.
Article in English | MEDLINE | ID: mdl-39109737

ABSTRACT

PURPOSE: This study aimed to analyze variations in intraoperative corneal thickness during corneal cross-linking in patients with keratoconus and to investigate its possible correlation with presurgical maximal keratometry (Kmax) and pachymetry. METHODS: This was a prospective case series. We used a method similar to the Dresden protocol, with the application of hydroxypropyl methylcellulose 0.1% hypo-osmolar riboflavin in corneas between 330 and 400 µm after epithelium removal. Corneal thickness was measured using portable calipers before and immediately after epithelium removal, and 30 and 60 min after the procedure. RESULTS: The 30 patients in this study were followed up for one year. A statistically significant difference was observed in pachymetry values during the intraoperative period (p<0.0001) and an increase of 3.05 µm (95%C1: 0.56-5.54) for each diopter was seen after epithelium removal (p0.019). We found an average Kmax difference of -2.12 D between men and women (p0.013). One year after treatment, there was a statistically significant reduction in pachymetry (p<0.0001) and Kmax (p0.0170) values. CONCLUSIONS: A significant increase in pachymetry measurements was seen during the procedure, and most patients showed a regression in Kmax and pachymetry values one year after surgery.


Subject(s)
Cornea , Corneal Pachymetry , Cross-Linking Reagents , Hypromellose Derivatives , Keratoconus , Photosensitizing Agents , Riboflavin , Humans , Riboflavin/therapeutic use , Female , Keratoconus/drug therapy , Male , Corneal Pachymetry/methods , Prospective Studies , Adult , Cross-Linking Reagents/therapeutic use , Young Adult , Cornea/diagnostic imaging , Cornea/pathology , Cornea/surgery , Cornea/drug effects , Hypromellose Derivatives/therapeutic use , Photosensitizing Agents/therapeutic use , Adolescent , Treatment Outcome , Time Factors , Intraoperative Period , Reference Values , Corneal Topography/methods , Reproducibility of Results
9.
Int Ophthalmol ; 44(1): 347, 2024 Aug 13.
Article in English | MEDLINE | ID: mdl-39138825

ABSTRACT

PURPOSE: Altered corneal biomechanics in patients with diabetes may affect intraocular pressure (IOP) measurements. Although a relationship between IOP and glucose levels has been reported in diabetic and nondiabetic patients, the mechanism by which hyperglycemia influences IOP is unclear. The aim of this study was to determine the effects of hyperglycemia on IOP, corneal biomechanics, and anterior segment parameters during the oral glucose tolerance test (OGTT) in nondiabetic patients. METHODS: Twenty-one patients without DM who underwent OGTT were included in this study. A complete ophthalmologic examination was performed before the test. Blood glucose, insulin level, IOP (iCare rebound tonometer), Ocular Response Analyzer, and corneal topography (Pentacam) measurements were obtained at 0, 1, and 2 h during the OGTT. Data from the patients' right eyes were included in the analysis. RESULTS: The mean age of the patients was 46.9 ± 11.0 years. There was a statistically significant difference in IOP between 1 and 2 h (p = 0.03) and a clinically significant difference between 0 and 1 h (p = 0.06). Corneal resistance factor was lower at 2 h than 1 h (p = 0.03), while central cornea thickness was increased at 1 h (p = 0.01) and 2 h (p = 0.05) compared to 0 h. There was positive partial correlation between hyperglycemia and IOP at 1 h (p = 0.049, r = 0.67). CONCLUSION: The positive partial correlation between IOP and glucose level suggests that acute hyperglycemia may lead to increased IOP. However, further research is needed to explain the mechanism of IOP elevation in the hyperglycemic phase during OGTT.


Subject(s)
Blood Glucose , Cornea , Corneal Topography , Glucose Tolerance Test , Hyperglycemia , Intraocular Pressure , Tonometry, Ocular , Humans , Intraocular Pressure/physiology , Female , Glucose Tolerance Test/methods , Male , Cornea/physiopathology , Cornea/diagnostic imaging , Cornea/pathology , Middle Aged , Hyperglycemia/physiopathology , Hyperglycemia/diagnosis , Blood Glucose/metabolism , Blood Glucose/analysis , Biomechanical Phenomena , Corneal Topography/methods , Adult
10.
Med J Malaysia ; 79(4): 375-379, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39086332

ABSTRACT

INTRODUCTION: Vernal keratoconjunctivitis (VKC) is a chronic allergic disease characterised by intense ocular surface symptoms and corneal involvement. There is limited data about the corneal changes in children with VKC based on severity of the disease. We aimed to compare the central corneal thickness (CCT) and corneal topographic indices in Malaysian children with VKC, as well as among the varying grades of VKC severity. MATERIALS AND METHODS: This study is a comparative, crosssectional and hospital-based study. We recruited 83 children with VKC and 83 healthy children as controls. All children underwent complete ocular examinations, CCT measurement using an ultrasound pachymeter and corneal topography using a Placido disc corneal analyser. RESULTS: There was a statistically significant difference of means CCT and topographic indices in children with VKC compared to controls (p<0.05). The probability keratoconus reached 18% in children with VKC. The mean CCT was observed to be thinnest in the severe-to-very severe groups of VKC compared to the mild-to-moderate (p<0.05). The means simulated-K1 and -K2, apical keratometry, apical gradient curvature, superior-inferior index and keratoconus prediction index were significantly different in severe-tovery severe VKC compared to mild-to-moderate VKC and controls (p<0.05). However, there was no significant difference in mean cylinder value and percent probability keratoconus when comparing different groups of severity of VKC (p=0.912 and 0.070 respectively). CONCLUSION: Children with VKC have thinner CCT and topographic indices changes compared to healthy children. Similar pattern was observed between groups with VKC. Degree of astigmatism and probability of keratoconus were similar in mild-to-moderate and severe-to-very severe groups.


Subject(s)
Conjunctivitis, Allergic , Cornea , Corneal Topography , Humans , Conjunctivitis, Allergic/diagnostic imaging , Conjunctivitis, Allergic/pathology , Child , Male , Female , Malaysia , Cornea/pathology , Cornea/diagnostic imaging , Cross-Sectional Studies , Adolescent , Case-Control Studies , Severity of Illness Index , Keratoconus/diagnostic imaging , Keratoconus/pathology
11.
J Refract Surg ; 40(7): e490-e498, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39007811

ABSTRACT

PURPOSE: To compare the objective visual quality of moderate-to-high myopia corrected by small incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK) at a 1,050-Hz ablation frequency, assisted by Smart-Pulse technology (SCHWIND eye-tech-solutions). METHODS: This study involved 123 patients (123 eyes) with moderate-to-high myopia between July 2020 and January 2021. They were categorized into the SMILE group (67 patients, 67 eyes) and the TransPRK group (56 patients, 56 eyes). Follow-ups were conducted at 6 months postoperatively to record the logarithm of the minimum angle of resolution visual acuity, and the Strehl ratio and higher order aberrations were measured using the Sirius anterior segment analysis device (SCHWIND eye-tech-solutions) under a 6-mm pupil diameter at various postoperative intervals. RESULTS: At 1 week and 1 month postoperatively, the uncorrected distance visual acuity (UDVA) in the SMILE group was superior to that in the TransPRK group (P < .05 for both). At 1 week and 1 month postoperatively, the Strehl ratio value in the SMILE group was higher than that in the TransPRK group (P < .05 for both). At 1, 3, and 6 months postoperatively, coma was greater in the SMILE group than in the TransPRK group (P < .05 for all). Spherical aberrations were lower in the SMILE group than in the TransPRK group at 3 and 6 months postoperatively (P < .05). At 6 months postoperatively, UDVA was -0.09 ± 0.08 and -0.11 ± 0.05 logMAR in the SMILE and TransPRK groups, respectively, which exceeded their preoperative corrected distance visual acuity of -0.05 ± 0.04 and -0.09 ± 0.08 logMAR (all P < .001). Compared with preoperative values, the Strehl ratio, total higher order, coma, and spherical aberration differences were significantly increased postoperatively in both groups (all P < .001). CONCLUSIONS: Both surgical methods improved UDVA and each had its advantages. The visual quality of SMILE was superior at 1 week and 1 month postoperatively (Strehl ratio values were higher than those of the TransPRK group), and its spherical aberration was lower than that of the TransPRK group at 3 and 6 months; TransPRK with SmartPulse technology with a 1,050-Hz ablation frequency showed that coma was significantly lower than that of the SMILE group at 1, 3, and 6 months postoperatively. [J Refract Surg. 2024;40(7):e490-e498.].


Subject(s)
Corneal Stroma , Lasers, Excimer , Photorefractive Keratectomy , Refraction, Ocular , Visual Acuity , Humans , Visual Acuity/physiology , Lasers, Excimer/therapeutic use , Female , Male , Photorefractive Keratectomy/methods , Adult , Refraction, Ocular/physiology , Young Adult , Corneal Stroma/surgery , Corneal Surgery, Laser/methods , Myopia, Degenerative/surgery , Myopia, Degenerative/physiopathology , Corneal Wavefront Aberration/physiopathology , Corneal Topography , Follow-Up Studies , Prospective Studies , Myopia/surgery , Myopia/physiopathology , Retrospective Studies
12.
J Refract Surg ; 40(7): e453-e459, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39007816

ABSTRACT

PURPOSE: To compare the prediction accuracy of the Barrett toric calculator using standard or integrated keratometry (IK) mode in combination with predicted or measured posterior corneal astigmatism (PCA) in a group of patients with cataract implanted with non-toric IOLs. METHODS: In this retrospective clinical cohort study, the medical records of patients with age-related cataract who underwent phacoemulsification with the implantation of an aspheric monofocal IOL were reviewed. Four methods, including standard keratometry with predicted PCA (PPCA), IK combined with predicted PCA (IK-PPCA), and IK combined with measured PCA derived from IOLMaster 700 (Carl Zeiss Meditec AG) or CASIA2 (Tomey) (IK-MMPCA or IK-CMPCA), were applied to the Barrett toric calculator to calculate the predicted residual astigmatism. The mean absolute prediction error (MAPE), centroid of the prediction error, and proportion of eyes within the prediction error of ±0.50, ±0.75, and ±1.00 diopters (D) were all ciphered out from the four methods, respectively. RESULTS: Data from 129 eyes of 129 patients were included in this study. The MAPE of the IK-PPCA method (0.57 ± 0.36 D) was significantly smaller than that of the PPCA (0.62 ± 0.38 D) and IK-CMPCA (0.63 ± 0.46 D) methods (P = .048 and .014, respectively). There were no significant differences in the centroid vectors of prediction errors and predictability rates among the four methods (all P > .05). CONCLUSIONS: In the current version of the Barrett toric calculator, the predictive accuracy of the IK mode incorporating PPCA was slightly superior to using the standard keratometry mode or incorporating MPCA. [J Refract Surg. 2024;40(7):e453-e459.].


Subject(s)
Astigmatism , Cornea , Phacoemulsification , Humans , Astigmatism/physiopathology , Astigmatism/diagnosis , Retrospective Studies , Male , Female , Aged , Cornea/physiopathology , Cornea/pathology , Reproducibility of Results , Middle Aged , Aged, 80 and over , Lens Implantation, Intraocular , Visual Acuity/physiology , Corneal Topography/methods , Refraction, Ocular/physiology , Lenses, Intraocular , Pseudophakia/physiopathology
13.
J Refract Surg ; 40(7): e445-e452, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39007818

ABSTRACT

PURPOSE: To evaluate the repeatability of automatic measurements of a new anterior segment optical coherence tomographer (ANTERION; Heidelberg Engineering) and their agreement with an anterior segment optical coherence tomography device combined with Placido disc corneal topography (MS-39; CSO) in patients affected by keratoconus. METHODS: Fifty-four consecutive patients were included. Three measurements were performed with the ANTERION and one with the MS-39. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Agreement was investigated with the 95% limits of agreement. The paired t-test and Wilcoxon matched-pairs test were performed to compare the measurements of the different devices. RESULTS: Repeatability of ANTERION measurements was high, with an ICC greater than 0.98 for all parameters. Many parameters revealed a CoV of less than 1% and a CoV within 5% was obtained for astigmatism measurements. The ANTERION measured a significantly higher corneal power and the MS-39 more negative posterior keratometric values. These differences were mirrored by a moderate agreement for mean simulated keratometry and poor agreement for total corneal power and posterior keratometry. CONCLUSIONS: The ANTERION revealed high repeatability of automatic measurements and good agreement with the MS-39 for many parameters in patients affected by keratoconus, but for most parameters the two instruments cannot be considered interchangeable. [J Refract Surg. 2024;40(7):e445-e452.].


Subject(s)
Anterior Eye Segment , Corneal Topography , Keratoconus , Tomography, Optical Coherence , Humans , Keratoconus/diagnosis , Keratoconus/physiopathology , Tomography, Optical Coherence/methods , Reproducibility of Results , Adult , Corneal Topography/methods , Male , Female , Anterior Eye Segment/diagnostic imaging , Young Adult , Biometry/instrumentation , Biometry/methods , Prospective Studies , Cornea/pathology , Cornea/diagnostic imaging , Middle Aged , Adolescent
14.
J Refract Surg ; 40(7): e480-e489, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39007817

ABSTRACT

PURPOSE: To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period. METHODS: A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes. RESULTS: Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery. CONCLUSIONS: This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. [ J Refract Surg. 2024;40(7):e480-e489.].


Subject(s)
Astigmatism , Hyperopia , Keratomileusis, Laser In Situ , Lasers, Excimer , Presbyopia , Refraction, Ocular , Software , Visual Acuity , Humans , Presbyopia/surgery , Presbyopia/physiopathology , Keratomileusis, Laser In Situ/methods , Visual Acuity/physiology , Refraction, Ocular/physiology , Lasers, Excimer/therapeutic use , Male , Hyperopia/physiopathology , Hyperopia/surgery , Middle Aged , Female , Adult , Astigmatism/physiopathology , Astigmatism/surgery , Treatment Outcome , Anisometropia/physiopathology , Anisometropia/surgery , Corneal Topography , Follow-Up Studies , Prospective Studies , Cornea/physiopathology , Cornea/surgery
15.
BMC Ophthalmol ; 24(1): 285, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39009964

ABSTRACT

AIM: This study aimed to differentiate moderate to high myopic astigmatism from forme fruste keratoconus using Pentacam parameters and develop a predictive model for early keratoconus detection. METHODS: We retrospectively analysed 196 eyes from 105 patients and compared Pentacam variables between myopic astigmatism (156 eyes) and forme fruste keratoconus (40 eyes) groups. Receiver operating characteristic curve analysis was used to determine the optimal cut-off values, and a logistic regression model was used to refine the diagnostic accuracy. RESULTS: Statistically significant differences were observed in most Pentacam variables between the groups (p < 0.05). Parameters such as the Index of Surface Variance (ISV), Keratoconus Index (KI), Belin/Ambrosio Deviation Display (BAD_D) and Back Elevation of the Thinnest Corneal Locale (B.Ele.Th) demonstrated promising discriminatory abilities, with BAD_D exhibiting the highest Area under the Curve. The logistic regression model achieved high sensitivity (92.5%), specificity (96.8%), accuracy (95.9%), and positive predictive value (88.1%). CONCLUSION: The simultaneous evaluation of BAD_D, ISV, B.Ele.Th, and KI aids in identifying forme fruste keratoconus cases. Optimal cut-off points demonstrate acceptable sensitivity and specificity, emphasizing their clinical utility pending further refinement and validation across diverse demographics.


Subject(s)
Corneal Topography , Keratoconus , Photography , ROC Curve , Humans , Keratoconus/diagnosis , Female , Male , Retrospective Studies , Adult , Ghana , Corneal Topography/methods , Photography/methods , Young Adult , Adolescent , Cornea/pathology , Cornea/diagnostic imaging , Middle Aged , Myopia/diagnosis , Astigmatism/diagnosis , Visual Acuity
16.
BMC Ophthalmol ; 24(1): 288, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39014345

ABSTRACT

BACKGROUND: Recently a new surgical technique for intracorneal ring-segments (ICRS) assisted by femtosecond laser (FSL) called ByLimB was developed, involving the creation of the incision from a paralimbic region. This study aims to evaluate the safety and efficacy of the ByLimb technique following one year of follow-up. METHODS: A prospective, single-center study was conducted at the Zaldivar Institute in Buenos Aires, Argentina. Keratoconus patients with indication for ICRS-FSL assisted procedure, operated with the ByLimb technique were included. By using the ByLimb technique, the ICRS are placed without affecting the tunnel's roof, and the end of the ICRS is always away from the incision area. Visual acuity, topographic astigmatism, and the occurrence of complications were evaluated. Safety index was the main outcome and efficacy indes was a complimentary outcome. RESULTS: A total of 17 eyes completed the 12-month follow-up period. The safety index was 1.10 (mean postoperative corrected distance visual acuity (CDVA) in decimal: 0.76/preoperative CDVA: 0.69), while the efficacy index was 0.89 (mean postoperative uncorrected distance visual acuity UDVA in decimal: 0.62/preoperative CDVA: 0.69). Mean preoperative astigmatism was 5.3 ± 2.3, decreasing twelve months after surgery at 2.1 ± 1.2 (p < 0.001). No eye loss lines of vision and no intraoperative complications were observed. During the first month after surgery, an improper positioning of the ICRS based on topographic assessment was detected in five cases. A second procedure was performed, which consisted of opening the incision and introducing a Sinsky hook, through which the ICRS was mobilized and placed in its correct position. No incisional alterations, signs of infection, anterior segment anomalies, or fundus alterations were observed. CONCLUSION: FSL-assisted ICRS implantation through the perilimbal region has demonstrated an adequate safety index one year post-surgery. Additionally, this technique has facilitated accurate realignment of ICRS during secondary surgical interventions within one-month post-surgery. While the current findings are promising, continued follow-up of these cases is warranted.


Subject(s)
Corneal Topography , Keratoconus , Prostheses and Implants , Prosthesis Implantation , Visual Acuity , Humans , Prospective Studies , Keratoconus/surgery , Keratoconus/physiopathology , Female , Male , Adult , Pilot Projects , Visual Acuity/physiology , Prosthesis Implantation/methods , Young Adult , Corneal Stroma/surgery , Follow-Up Studies , Refraction, Ocular/physiology , Middle Aged , Laser Therapy/methods , Treatment Outcome
17.
Int Ophthalmol ; 44(1): 331, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39037500

ABSTRACT

PURPOSE: To compare the clinical outcomes of myopiacorrected with corneal-wavefront-guided (CWG) laser in situ keratomileusis (LASIK) with AMARIS 1050S (SCHWIND eye-tech-solutions GmbH & Co. KG) and corneal-topography-guided (CTG) LASIK with WaveLight EX500 (Alcon Laboratories, Fort Worth, TX). METHODS: In this prospective, pseudo-randomized expanded cohort study, a total of 266 patients were subjected to binocular LASIK surgery, either with WaveLight EX500 (WaveLight group) or Amaris 1050S (AMARIS group) platforms. Data related to right eyes were selected for analysis. Corneal higher-order aberration (HOA) was selected as the primary endpoint; while visual acuity and refraction were the secondary endpoints. All the endpoints were assessed at 3 months postoperatively. RESULTS: There were 134 eyes in the AMARIS group and 132 eyes in the WaveLight group. After 3 months of postoperative follow-up, spherical and coma aberrations were significantly lower (P < 0.05) in the WaveLight group (spherical aberration: - 0.104 ± 0.199 µm; coma aberration: - 0.117 ± 0.202 µm) in comparison with the AMARIS group (spherical aberrations: 0.254 ± 0.146 µm; coma aberrations: 0.316 ± 0.297 µm). In the AMARIS group, 96.3% of the eyes achieved an uncorrected distance visual acuity (UDVA) of 20/20 while in the WaveLight group, 96.2% of the eyes achieved an UDVA of 20/20. Furthermore, the mean postoperative manifest refraction spherical equivalent (MRSE) was - 0.02 ± 0.28 in the AMARIS group and - 0.05 ± 0.21 in the WaveLight group (P = 0.34). CONCLUSIONS: Both WaveLight EX500 and Amaris 1050S LASIK showed excellent refractive and visual outcomes. In addition, the WaveLight group showed minimal spherical and coma aberrations when compared to the AMARIS group.


Subject(s)
Cornea , Corneal Topography , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Refraction, Ocular , Visual Acuity , Humans , Keratomileusis, Laser In Situ/methods , Female , Prospective Studies , Male , Adult , Refraction, Ocular/physiology , Myopia/surgery , Myopia/physiopathology , Lasers, Excimer/therapeutic use , Cornea/surgery , Young Adult , Treatment Outcome , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/diagnosis , Follow-Up Studies
18.
Int Ophthalmol ; 44(1): 302, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38954134

ABSTRACT

PURPOSE: To compare early changes in the corneal biomechanical parameters after photorefractive keratectomy (PRK) and small incision lenticule extraction (SMILE) and their correlations with corneal shape parameters. METHODS: One hundred twenty four eyes received myopic PRK and SMILE for similar amounts of myopia. Corneal tomography with Pentacam HR, biomechanical parameters using Corvis ST, and Ocular Response Analyzer (ORA) were evaluated before and 2 weeks after surgery. The change in each parameter was compared between groups, while the difference in central corneal thickness and cornea-compensated intraocular pressure measured before and after surgery were considered as covariates. RESULTS: A significant reduction was seen in the corneal stiffness parameter at first applanation, and an increase in deformation amplitude ratio (DAR), and integrated inverse radius (IIR) in both groups after surgery (p < 0.001) Changes in DAR, and IIR were significantly greater in the SMILE than in the PRK group (p < 0.001) Corneal hysteresis (CH) and corneal resistance factor (CRF) decreased in both SMILE and PRK groups after surgery, (p < 0.001) with no statistically significant difference between groups (p > 0.05) Among new Corvis ST parameters, DAR showed a significant correlation with changes in Ambrosio relational thickness in both groups (p < 0.05). CONCLUSIONS: Both techniques caused significant changes in corneal biomechanics in the early postoperative period, with greater elastic changes in the SMILE group compared to the PRK group, likely due to lower tension in the SMILE cap and thinner residual stromal bed in SMILE. There were no differences in viscoelastic changes between them, so the lower CH may reflect the volume of tissue removed.


Subject(s)
Cornea , Elasticity , Myopia , Photorefractive Keratectomy , Humans , Photorefractive Keratectomy/methods , Myopia/surgery , Myopia/physiopathology , Cornea/surgery , Cornea/physiopathology , Cornea/diagnostic imaging , Female , Male , Adult , Elasticity/physiology , Biomechanical Phenomena , Young Adult , Lasers, Excimer/therapeutic use , Intraocular Pressure/physiology , Corneal Surgery, Laser/methods , Refraction, Ocular/physiology , Corneal Topography , Corneal Stroma/surgery , Postoperative Period , Visual Acuity/physiology , Prospective Studies , Follow-Up Studies
19.
Ophthalmic Physiol Opt ; 44(6): 1224-1236, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38980216

ABSTRACT

PURPOSE: To optimise the precision and efficacy of orthokeratology, this investigation evaluated a deep neural network (DNN) model for lens fitting. The objective was to refine the standardisation of fitting procedures and curtail subjective evaluations, thereby augmenting patient safety in the context of increasing global myopia. METHODS: A retrospective study of successful orthokeratology treatment was conducted on 266 patients, with 449 eyes being analysed. A DNN model with an 80%-20% training-validation split predicted lens parameters (curvature, power and diameter) using corneal topography and refractive indices. The model featured two hidden layers for precision. RESULTS: The DNN model achieved mean absolute errors of 0.21 D for alignment curvature (AC), 0.19 D for target power (TP) and 0.02 mm for lens diameter (LD), with R2 values of 0.97, 0.95 and 0.91, respectively. Accuracy decreased for myopia of less than 1.00 D, astigmatism exceeding 2.00 D and corneal curvatures >45.00 D. Approximately, 2% of cases with unique physiological characteristics showed notable prediction variances. CONCLUSION: While exhibiting high accuracy, the DNN model's limitations in specifying myopia, cylinder power and corneal curvature cases highlight the need for algorithmic refinement and clinical validation in orthokeratology practice.


Subject(s)
Corneal Topography , Myopia , Neural Networks, Computer , Orthokeratologic Procedures , Refraction, Ocular , Humans , Orthokeratologic Procedures/methods , Retrospective Studies , Myopia/therapy , Myopia/physiopathology , Female , Male , Refraction, Ocular/physiology , Adolescent , Cornea/pathology , Cornea/diagnostic imaging , Contact Lenses , Young Adult , Child , Adult , Visual Acuity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL